Abstract:
PURPOSE:Introducing advanced hemodynamic monitoring might be beneficial during Helicopter Emergency Medical Service (HEMS) care. However, it should not increase the on-scene-time, it should be easy to use and should be non-invasive. The goal of this study was to investigate the feasibility of non-invasive cardiac output measurements by electrical cardiometry (EC) and the quality of the EC signal during pre-hospital care provided by our HEMS. METHODS:A convenience sample of fifty patients who required HEMS assistance were included in this study. Problems with respect to connecting the patient, entering patient characteristics and measuring were inventoried. Quality of EC signal of the measurements was assessed during prehospital helicopter care. We recorded the number of measurements with a signal quality indicator (SQI) ≥ 80 and the number of patients having at least 1 measurement with a SQI ≥ 80. Furthermore, the SQI value distribution of the measurements within each patient was analysed. RESULTS:In the experience of the attending HEMS caregivers application of the device was easy and did not result in increased duration of on-scene time. Patch adhesion was reported as a concern due to clammy skin in 22% of all cases. 684 measurements were recorded during HEMS care. In 47 (94%) patients at least 1 measurement with an SQI ≥ 80 was registered. Of all recorded measurements 5.8% had an SQI < 40, 11.4% had an SQI 40-59, 14.9% had a SQI between 60 and 79 and 67.8% had SQI ≥ 80. CONCLUSION:Cardiac output measurements are feasible during prehospital HEMS care with good quality of the EC signal. Monitoring was easy to use and quick to install. In our view it is an promising candidate for the prehospital setting. Further research is needed to determine its clinical value during clinical decision making.
journal_name
J Clin Monit Computjournal_title
Journal of clinical monitoring and computingauthors
Slagt C,Servaas S,Ketelaars R,van Geffen GJ,Tacken MCT,Verrips CA,Baggen LAM,Scheffer GJ,van Eijk LTdoi
10.1007/s10877-021-00657-5subject
Has Abstractpub_date
2021-01-23 00:00:00eissn
1387-1307issn
1573-2614pii
10.1007/s10877-021-00657-5pub_type
杂志文章abstract:OBJECTIVE:It was hypothesized that somato- sensory evoked potentials can be achieved faster by selective averaging during periods of low spontaneous electroen- cephalographic (EEG) activity. We analyzed the components of EEG that decrease the signal-to-noise ratio of somatosensory evoked potential (SEP) recordings duri...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-009-9188-6
更新日期:2009-08-01 00:00:00
abstract:OBJECTIVE:Artefact detection is an essential feature of automatic EEG monitoring systems used in anaesthesia. Clinical experience indicates that Narcotrend monitoring (MonitorTechnik, Bad Bramstedt, Germany, version 4.0) excludes more EEG epochs because of artefacts than bispectral index monitoring (BIS, Aspect Medical...
journal_title:Journal of clinical monitoring and computing
pub_type: 临床试验,杂志文章
doi:10.1007/s10877-005-2700-8
更新日期:2004-08-01 00:00:00
abstract::Recent progress in genomics and experimental biology has brought exponential growth of the biological information available for computational analysis in public genomics databases. However, applying the potentially enormous scientific value of this information to the understanding of biological systems requires comput...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-3463-y
更新日期:2005-10-01 00:00:00
abstract::Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9790-8
更新日期:2016-12-01 00:00:00
abstract:INTRODUCTION:Patients undergoing lung resection are vulnerable to fluid overhydration. Recently, goal-directed fluid therapy using transoesophageal Doppler monitoring (TDM) has been shown to improve postoperative clinical outcome. The aim of this study was to assess the feasibility of TDM during open-chest procedures f...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-008-9144-x
更新日期:2008-10-01 00:00:00
abstract:OBJECTIVES:Bioreactance, the analysis of intrabeat variations in phase of a transthoracic voltage in response to an applied high frequency transthoracic current, was recently introduced for noninvasive cardiac output measurement (NICOM). We evaluated NICOM compared to thermo- dilution (TD) in several clinical settings....
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,多中心研究
doi:10.1007/s10877-008-9112-5
更新日期:2008-04-01 00:00:00
abstract::Uncalibrated arterial waveform analysis enables dynamic preload assessment in a minimally invasive fashion. Evidence about the validity of the technique in patients with impaired left ventricular function is scarce, while adequate cardiac preload assessment would be of great value in these patients. The aim of this st...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9743-2
更新日期:2016-08-01 00:00:00
abstract::An intraoperative automated closed-loop system for goal-directed fluid therapy has been successfully tested in silico, in vivo and in a clinical case-control matching. This trial compared intraoperative cardiac output (CO) in patients managed with this closed-loop system versus usual practice in an academic medical ce...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-018-0106-7
更新日期:2018-12-01 00:00:00
abstract::Compared with supine positioning, head-up positioning improves preoxygenation and prolongs the time to oxygen desaturation. We reevaluated benefits of head-up positioning using near-infrared spectroscopy (NIRS) with pulse oximetry in a pig model. Six pigs (mean ± SD weight: 25.3 ± 0.6 kg) were anesthetized with isoflu...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00456-z
更新日期:2020-01-02 00:00:00
abstract::The purpose of this concept study was to investigate the possibility of automatic mean arterial pressure (MAP) regulation in a porcine heart-beating brain death (BD) model. Hemodynamic stability of BD donors is necessary for maintaining acceptable quality of donated organs for transplantation. Manual stabilization is ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-017-0033-z
更新日期:2018-06-01 00:00:00
abstract::Recent advances in technology have brought many kinds of monitoring devices into the operating room (OR). The information gathered by monitors can be channeled to the operating ward information system via a local area network (LAN). Connecting patients to monitors and monitors to the LAN, however, requires a large num...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1009911208828
更新日期:2000-01-01 00:00:00
abstract::The composite auditory evoked potentials index (cAAI) uses both cortical electroencephalogram (EEG) and response to auditory stimuli, while the bispectral index (BIS) uses only the cortical EEG and auditory evoked potentials index (AAI) uses only response to auditory stimuli. We expected that the cAAI was more useful ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-013-9441-x
更新日期:2013-06-01 00:00:00
abstract::Pulse pressure variation (PPV) and cardiac output (CO) can guide perioperative fluid management. Capstesia (Galenic App, Vitoria-Gasteiz, Spain) is a mobile application for snapshot pulse wave analysis (PWAsnap) and estimates PPV and CO using pulse wave analysis of a snapshot of the arterial blood pressure waveform di...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00572-1
更新日期:2020-08-04 00:00:00
abstract::Mechanically ventilated patients with ARDS due to the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) seem particularly susceptible to AKI. Our hypothesis was that the renal blood flow could be more compromised in SARS-CoV-2 patients than in patients with "classical" ARDS. We compared the renal resistivit...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00633-5
更新日期:2021-01-01 00:00:00
abstract::Cerebrovascular autoregulation (CA) is often impaired following traumatic brain injury. Established technologies and metrics used to assess CA are invasive and conducive for measurement, but not for continuous monitoring. We developed a trans-ocular brain impedance (TOBI) method that may provide non-invasive and conti...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00556-1
更新日期:2020-07-14 00:00:00
abstract::Electrical impedance tomography (EIT) is used in lung physiology monitoring. There is evidence that EIT is linearly associated with global tidal volume (VT) in clinically healthy patients where no positive end-expiratory pressure (PEEP) is applied. This linearity has not been challenged by altering lung conditions. Th...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-021-00651-x
更新日期:2021-01-25 00:00:00
abstract::We evaluated the effects of three different inspired oxygen concentrations (40%, 80%, and 100%) at anaesthesia emergence on postoperative lung volumes as measured by global impedance of electrical impedance tomography (EIT). This is a randomised, controlled, and assessor-blinded study in single-centre from May 2017 to...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00390-0
更新日期:2020-10-01 00:00:00
abstract:OBJECTIVE:Transcranial Motor Evoked Potentials (TcMEPs) are sometimes used during lumbar spine surgery in order to detect and prevent an intraoperative nerve root injury. Typically, a fixed stimulus is applied, and one monitors for changes in response amplitude from several myotomes. Increased stimulating voltage may o...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-010-9269-6
更新日期:2010-12-01 00:00:00
abstract::Transesophageal echocardiography of the spine has been difficult to perform, and high-quality images have been difficult to obtain with earlier available technology. New capabilities in hardware and software reconstruction may allow more reliable clinical data to be obtained. We describe an initial successful attempt ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-014-9576-4
更新日期:2015-02-01 00:00:00
abstract:OBJECTIVE:To compare expert-generated textual summaries of physiological data with trend graphs, in terms of their ability to support neonatal Intensive Care Unit (ICU) staff in making decisions when presented with medical scenarios. METHODS:Forty neonatal ICU staff were recruited for the experiment, eight from each o...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-0879-3
更新日期:2005-06-01 00:00:00
abstract::The mesenteric traction syndrome (MTS) is associated with prostacyclin (PGI2) facilitated systemic vasodilatation during surgery and is identified by facial flushing. We hypothesized that severe facial flushing would be related to the highest concentrations of plasma PGI2 and accordingly to the highest levels of skin ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0226-0
更新日期:2019-10-01 00:00:00
abstract:OBJECTIVE:Awareness with recall is a rare but serious complication of general anaesthesia with an incidence ranging from 0.1%-0.7%. In the absence of a reliable depth-of-anaesthesia monitor, attempts have been made to predict awareness from intraoperative haemodynamic monitoring data, with little success. Artificial ne...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1015426015547
更新日期:2002-01-01 00:00:00
abstract::Numerous factors could contribute to sleep disturbances in women with breast cancer. We hypothesized that stellate ganglion block (SGB) during surgery would preserve sleep after surgery and increase intraoperative regional cerebral oxygen saturation (rSO2) on the blocked side in patients undergoing breast cancer surge...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-017-0074-3
更新日期:2018-10-01 00:00:00
abstract::Hypotension subsequent to spinal anesthesia occurs in a significant number of parturients undergoing lower segment caesarian section. Currently available methods to predict the incidence of hypotension, its severity and the outcome are sub-optimal. Many workers have used basal heart rate as one of the predictors. But ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9906-9
更新日期:2017-08-01 00:00:00
abstract::The widespread implementation of computerized medical files in intensive care units (ICUs) over recent years has made available large databases of clinical data for the purpose of developing clinical prediction models. The typical intensive care unit has several information sources from which data is electronically co...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-012-9416-3
更新日期:2013-08-01 00:00:00
abstract::Hypothermia is a common perioperative complication. To prevent perioperative hypothermia amongst other things electrical heating mattresses are used. We have made an observation with the use of an electrical heating mattress that may confuse users. In this case the ECG monitoring suddenly showed spikes that looked lik...
journal_title:Journal of clinical monitoring and computing
pub_type: 信件
doi:10.1007/s10877-020-00520-z
更新日期:2020-07-15 00:00:00
abstract::The Nexfin device allows for non-invasive beat-to-beat blood pressure monitoring (BP(NXF)). Perioperative hypotension and hypertension have been shown to be associated with poor clinical outcomes. The goal of the present study was to assess the ability of this device to decrease the duration of significant intraoperat...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-012-9344-2
更新日期:2012-04-01 00:00:00
abstract::Aortic peak systolic velocity variation (ΔVpeakAo) is a reliable dynamic indicator of preload in mechanically ventilated children. However, easily measurable alternative parameters like carotid peak systolic velocity variation (ΔVpeakCa) and suprasternal peak systolic velocity variation (ΔVpeakSs) are not well evaluat...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00431-8
更新日期:2020-12-01 00:00:00
abstract::Patient-ventilator asynchrony is associated with intolerance to noninvasive ventilation (NIV) and worsened outcomes. Our goal was to develop a tool to determine a patient needs for intervention by a practitioner due to the presence of patient-ventilator asynchrony. We postulated that a clinician can determine when a ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00408-7
更新日期:2020-10-01 00:00:00
abstract::Central venous cannulation is a commonly preformed procedure in many branches of medicine, particularly in anaesthesia and intensive care medicine. The purpose of this study was to compare the landmark-guided technique to the ultrasound-guided technique for internal jugular vein cannulation in cardiovascular surgery p...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-014-9585-3
更新日期:2015-02-01 00:00:00