Performance of a capnodynamic method estimating effective pulmonary blood flow during transient and sustained hypercapnia.

Abstract:

:The capnodynamic method is a minimally invasive method continuously calculating effective pulmonary blood flow (COEPBF), equivalent to cardiac output when intra pulmonary shunt flow is low. The capnodynamic equation joined with a ventilator pattern containing cyclic reoccurring expiratory holds, provides breath to breath hemodynamic monitoring in the anesthetized patient. Its performance however, might be affected by changes in the mixed venous content of carbon dioxide (CvCO2). The aim of the current study was to evaluate COEPBF during rapid measurable changes in mixed venous carbon dioxide partial pressure (PvCO2) following ischemia-reperfusion and during sustained hypercapnia in a porcine model. Sixteen pigs were submitted to either ischemia-reperfusion (n = 8) after the release of an aortic balloon inflated during 30 min or to prolonged hypercapnia (n = 8) induced by adding an instrumental dead space. Reference cardiac output (CO) was measured by an ultrasonic flow probe placed around the pulmonary artery trunk (COTS). Hemodynamic measurements were obtained at baseline, end of ischemia and during the first 5 min of reperfusion as well as during prolonged hypercapnia at high and low CO states. Ischemia-reperfusion resulted in large changes in PvCO2, hemodynamics and lactate. Bias (limits of agreement) was 0.7 (-0.4 to 1.8) L/min with a mean error of 28% at baseline. COEPBF was impaired during reperfusion but agreement was restored within 5 min. During prolonged hypercapnia, agreement remained good during changes in CO. The mean polar angle was -4.19° (-8.8° to 0.42°). Capnodynamic COEPBF is affected but recovers rapidly after transient large changes in PvCO2 and preserves good agreement and trending ability during states of prolonged hypercapnia at different levels of CO.

journal_name

J Clin Monit Comput

authors

Sigmundsson TS,Öhman T,Hallbäck M,Redondo E,Sipmann FS,Wallin M,Oldner A,Hällsjö Sander C,Björne H

doi

10.1007/s10877-017-0021-3

subject

Has Abstract

pub_date

2018-04-01 00:00:00

pages

311-319

issue

2

eissn

1387-1307

issn

1573-2614

pii

10.1007/s10877-017-0021-3

journal_volume

32

pub_type

杂志文章
  • Technologies and solutions for data display in the operating room.

    abstract::Recent advances in technology have led to the introduction of a variety of innovative devices, each with their own platform for data display, into the operating room (OR). While these innovative applications are expanding the traditional boundaries of the surgical space and enhancing treatment capabilities, the introd...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-006-9017-0

    authors: Bitterman N

    更新日期:2006-06-01 00:00:00

  • The sounds of saturation.

    abstract::Audible pulse tones, based on a variable-pitch frequency scale, allow the anesthesiologist to determine the patient's oxygen saturation without constant visual examination of the monitor display. The ability to reliably detect oxygen saturation levels based on audible pulse tones may be compromised when multiple pulse...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000032698.47717.06

    authors: Santamore DC,Cleaver TG

    更新日期:2004-04-01 00:00:00

  • A comparison of graphical and textual presentations of time series data to support medical decision making in the neonatal intensive care unit.

    abstract:OBJECTIVE:To compare expert-generated textual summaries of physiological data with trend graphs, in terms of their ability to support neonatal Intensive Care Unit (ICU) staff in making decisions when presented with medical scenarios. METHODS:Forty neonatal ICU staff were recruited for the experiment, eight from each o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-0879-3

    authors: Law AS,Freer Y,Hunter J,Logie RH,McIntosh N,Quinn J

    更新日期:2005-06-01 00:00:00

  • Effects of prolonged ischemia on human skeletal muscle microcirculation as assessed by near-infrared spectroscopy.

    abstract::Near-infrared spectroscopy (NIRS) has been used to detect in vivo microvascular alterations by means of a vascular occlusion test. We sought to analyse by NIRS the microcirculatory profile of patients undergoing prolonged tourniquet-induced bloodless condition for extremity surgery, and compare the results with time o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9877-x

    authors: Tujjar O,De Gaudio AR,Tofani L,Di Filippo A

    更新日期:2017-06-01 00:00:00

  • Automated titration of propofol and remifentanil decreases the anesthesiologist's workload during vascular or thoracic surgery: a randomized prospective study.

    abstract::Closed loop target-control infusion systems using a Bispectral (BIS) signal as an input (TCI Loop) can automatically maintain intravenous anesthesia in a BIS range of 40-60 %. Our purpose was to assess to what extent such a system could decrease anesthesia workload in comparison to the use of a stand alone TCI system ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-013-9453-6

    authors: Dussaussoy C,Peres M,Jaoul V,Liu N,Chazot T,Picquet J,Fischler M,Beydon L

    更新日期:2014-02-01 00:00:00

  • Computerized recording of neuromuscular monitoring and the risk of residual paralysis at the time of extubation.

    abstract:OBJECTIVE:We tested whether a newly installed neuromuscular monitoring device (NMT) with a computerized anesthesia recording system, incorporated in all anesthesia stations, could enhance the commitment to objective neuromuscular monitoring in a teaching hospital anesthesia department. METHODS:After 6 months of famili...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9135-y

    authors: Motamed C,Bourgain JL

    更新日期:2008-08-01 00:00:00

  • A new calibration method that compensates for the effects of O2 and N2 on infrared CO2 analysers.

    abstract:OBJECTIVE:This study evaluates a method for calibrating mainstream CO(2) analysers in which CO(2) partial pressure (P (CO2)) is calculated as a function of the outputs of CO(2) and O(2) analysers. METHODS:Three mass flow controllers were used to generate 25 different reference mixtures of O(2), N(2) and CO(2). Referen...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9005-9

    authors: Tang Y,Turner MJ,Baker AB

    更新日期:2006-04-01 00:00:00

  • Pulmonary air embolism.

    abstract::Pulmonary air embolism is a well-known consequence of surgery, trauma, diving, and aviation. This article reviews the physiological effects, means of detection and methods of prevention and treatment of pulmonary air embolism. The primary physiological effects are elevated pulmonary artery pressures, increased ventila...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1023/a:1011455701892

    authors: Souders JE

    更新日期:2000-01-01 00:00:00

  • Intraoperative electrode burns.

    abstract:OBJECTIVES:The purpose of this paper is to increase awareness of electrode burns that occur in the operating room (OR), to discuss their causes, warning signs, and methods that may reduce their occurrence. Two general sources of electrical burns are described: 1) Excessive radio-frequency current density usually origin...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000025254.73456.db

    authors: Russell MJ,Gaetz M

    更新日期:2004-02-01 00:00:00

  • Investigation of optical neuro-monitoring technique for detection of maintenance and emergence states during general anesthesia.

    abstract::The American Society of Anesthesiologist recommends peripheral physiological monitoring during general anesthesia, which offers no information regarding the effects of anesthetics on the brain. Since no "gold standard" method exists for this evaluation, such a technique is needed to ensure patient comfort, procedure q...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-9998-x

    authors: Hernandez-Meza G,Izzetoglu M,Osbakken M,Green M,Abubakar H,Izzetoglu K

    更新日期:2018-02-01 00:00:00

  • Cricoid-mental distance-based versus weight-based criteria for size selection of classic laryngeal mask airway in adults: a randomized controlled study.

    abstract::The optimal size selection of laryngeal mask airway (LMA) based on body weight is not always applicable. This study was prospectively conducted to evaluate the efficacy of cricoid-mental distance-based method versus weight-based method in optimal size selection of LMA in adults. Seventy-four patients (aged from 18 to ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-019-00308-w

    authors: Zhu Y,Shen W,Lin Y,Huang T,Xie L,Yang Y,Chen H,Gan X

    更新日期:2019-10-01 00:00:00

  • Validation of a photoplethysmography device for detection of obstructive sleep apnea in the perioperative setting.

    abstract::Obstructive sleep apnea (OSA) is a risk factor for perioperative complications, but many OSA patients present undiagnosed. While polysomnography (PSG) is the "gold standard" for diagnosis, its application is technology-intense, time-consuming, expensive, and requires specialists, often delaying surgery. Thus, miniatur...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0151-2

    authors: Faßbender P,Haddad A,Bürgener S,Peters J

    更新日期:2019-04-01 00:00:00

  • Transoesophageal Doppler monitoring for fluid and hemodynamic treatment during lung surgery.

    abstract:INTRODUCTION:Patients undergoing lung resection are vulnerable to fluid overhydration. Recently, goal-directed fluid therapy using transoesophageal Doppler monitoring (TDM) has been shown to improve postoperative clinical outcome. The aim of this study was to assess the feasibility of TDM during open-chest procedures f...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9144-x

    authors: Diaper J,Ellenberger C,Villiger Y,Robert J,Tschopp JM,Licker M

    更新日期:2008-10-01 00:00:00

  • Does the EEG during isoflurane/alfentanil anesthesia differ from linear random data?

    abstract:OBJECTIVE:Bispectral analysis of the electroencephalogram (EEG) has been used to monitor depth of anesthesia. In the majority of publications this has been done using the so called Bispectral (BIS) Index. The exact relation of this index to bispectral quantities like the bispectrum and its normalized version the bicohe...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1026284321451

    authors: Schwilden H,Jeleazcov C

    更新日期:2002-12-01 00:00:00

  • Monitoring of breathing phases using a bioacoustic method in healthy awake subjects.

    abstract:OBJECTIVE:To test the ability of a microphone recording system, located distal to the respiratory outflow tract, to track the timing of the inspiratory and expiratory phases of breathing in awake healthy subjects. METHODS:Fifteen subjects participated. Breath sounds were recorded using a microphone embedded in a face ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-011-9307-z

    authors: Alshaer H,Fernie GR,Bradley TD

    更新日期:2011-10-01 00:00:00

  • Oesophageal balloon calibration during pressure support ventilation: a proof of concept study.

    abstract::Oesophageal balloon calibration improves the oesophageal pressure (Pes) assessment during invasive controlled mechanical ventilation. The primary aim of the present investigation was to ascertain the feasibility of oesophageal balloon calibration during pressure support ventilation (PSV). Secondarily, the calibrated P...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00436-3

    authors: Cammarota G,Verdina F,Santangelo E,Lauro G,Boniolo E,Tarquini R,Spinelli E,Zanoni M,Garofalo E,Bruni A,Pesenti A,Della Corte F,Navalesi P,Vaschetto R,Mauri T

    更新日期:2020-12-01 00:00:00

  • COVID-19: Pulse oximeters in the spotlight.

    abstract::From home to intensive care units, innovations in pulse oximetry are susceptible to improve the monitoring and management of patients developing acute respiratory failure, and particularly those with the coronavirus disease 2019 (COVID-19). They include self-monitoring of oxygen saturation (SpO2) from home, continuous...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 社论

    doi:10.1007/s10877-020-00550-7

    authors: Michard F,Shelley K,L'Her E

    更新日期:2020-06-23 00:00:00

  • Estimation of pulse pressure variation and cardiac output in patients having major abdominal surgery: a comparison between a mobile application for snapshot pulse wave analysis and invasive pulse wave analysis.

    abstract::Pulse pressure variation (PPV) and cardiac output (CO) can guide perioperative fluid management. Capstesia (Galenic App, Vitoria-Gasteiz, Spain) is a mobile application for snapshot pulse wave analysis (PWAsnap) and estimates PPV and CO using pulse wave analysis of a snapshot of the arterial blood pressure waveform di...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00572-1

    authors: Hoppe P,Gleibs F,Briesenick L,Joosten A,Saugel B

    更新日期:2020-08-04 00:00:00

  • Detection of intratracheal accumulation of thick secretions by using continuous monitoring of respiratory acoustic spectrum: a preliminary analysis.

    abstract::The accumulation of tracheobronchial secretions may contribute to a deterioration in pulmonary function and its early detection is important. In this study, we analyzed the respiratory sound spectrum in patients with intratracheal secretion, and compared acoustic characteristics before and after therapeutic endotrache...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00359-z

    authors: Moon YJ,Bechtel AJ,Kim SH,Kim JW,Thiele RH,Blank RS

    更新日期:2020-08-01 00:00:00

  • Selection of cuffed endotracheal tube for children with congenital heart disease based on an ultrasound-based linear regression formula.

    abstract::It remains to be discovered whether a formula predicting the subglottic transverse diameter measured by ultrasound (SGDformula) for the selection of an appropriate endotracheal tube (ETT) for children without congenital heart disease (CHD) is useful for children with CHD. A formula for predicting SGD was established a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0203-7

    authors: Zhang K,Ma RJ,Zheng JJ,Chen YQ,Zhang MZ

    更新日期:2019-08-01 00:00:00

  • Electrical impedance tomography's correlation to lung volume is not influenced by anthropometric parameters.

    abstract:STUDY OBJECTIVES:Electrical impedance tomography (EIT) is able to reflect physiological parameters such as real-time changes in global and regional lung volume. EIT can aid in the assessment of lung recruitment, and its use has been validated in preliminary studies monitoring mechanical ventilation at the bedside. ICU ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-006-9021-4

    authors: Marquis F,Coulombe N,Costa R,Gagnon H,Guardo R,Skrobik Y

    更新日期:2006-06-01 00:00:00

  • Unconsciousness indication using time-domain parameters extracted from mid-latency auditory evoked potentials.

    abstract:OBJECTIVE:The mid-latency auditory evoked potential (MLAEP) has been used to indicate depth of anaesthesia, and is usually analysed in time-domain. This work compares three techniques: Wave Deformation Parameters (PDO), Auditory Evoked Potential Index (AEPidx) and an automatic Nb-wave latency estimator (Nb), in the ass...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1023/a:1024208827407

    authors: Cagy M,Infantosi AF

    更新日期:2002-08-01 00:00:00

  • Two-site regional oxygen saturation and capnography monitoring during resuscitation after cardiac arrest in a swine pediatric ventricular fibrillatory arrest model.

    abstract:ABSTARCT:To investigate the use of two-site regional oxygen saturations (rSO2) and end tidal carbon dioxide (EtCO2) to assess the effectiveness of resuscitation and return of spontaneous circulation (ROSC). Eight mechanically ventilated juvenile swine underwent 28 ventricular fibrillatory arrests with open cardiac mass...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00291-2

    authors: Al-Subu AM,Hacker TA,Eickhoff JC,Ofori-Amanfo G,Eldridge MW

    更新日期:2020-02-01 00:00:00

  • Determining the artifact sensitivity of recent pulse oximeters during laboratory benchmarking.

    abstract::This study aimed to investigate and compare the performance of the algorithms contained in the newest generation of pulse oximeters (Masimo SET in IVY2000, Nellcor Oxismart N-3000, Agilent M3 rev. B) against a traditional pulse oximeter (Agilent CMS rel. A.0). The benchmark was performed in an efficient and reproducib...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1011420228523

    authors: Kästle SW,Konecny E

    更新日期:2000-01-01 00:00:00

  • Effective hypertensive treatment using data mining in Saudi Arabia.

    abstract::In the present investigation, the data sets of NCD (Non Communicable Diseases) risk factors, a standard report of Saudi Arabia 2005, in collaboration with WHO (World Health Organisation) were employed. The Oracle Data Miner (ODM) tool was used for the analysis and prediction of data. The data sets for different age gr...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-010-9260-2

    authors: Almazyad AS,Ahamad MG,Siddiqui MK,Almazyad AS

    更新日期:2010-12-01 00:00:00

  • Dynamic prediction of the need for renal replacement therapy in intensive care unit patients using a simple and robust model.

    abstract::We aimed at identifying a model that dynamically predicts future need for renal replacement therapy (RRT) in intensive care unit (ICU) patients and can easily be implemented for online monitoring at the bedside. 7290 interdisciplinary ICU admissions were investigated. Patients with <3 days of stay or RRT in the first ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9814-4

    authors: Erdfelder F,Grigutsch D,Hoeft A,Reider E,Matot I,Zenker S

    更新日期:2017-02-01 00:00:00

  • The influence of basic ventilation strategies on cerebral oxygenation in anesthetized patients without vascular disease.

    abstract:OBJECTIVES:Optimizing cerebral oxygenation is of paramount importance in certain intraoperative situations. There is, however, a paucity of published data pertaining to changes in cerebral oxygenation seen with increases in the inspired fraction of oxygen (FIO2) or end-tidal carbon dioxide (PETCO2) in anesthetized pati...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-010-9265-x

    authors: Picton P,Shanks A,Dorje P,Mashour GA

    更新日期:2010-12-01 00:00:00

  • Sympatho-vagal balance, as quantified by ANSindex, predicts post spinal hypotension and vasopressor requirement in parturients undergoing lower segmental cesarean section: a single blinded prospective observational study.

    abstract::Hypotension subsequent to spinal anesthesia occurs in a significant number of parturients undergoing lower segment caesarian section. Currently available methods to predict the incidence of hypotension, its severity and the outcome are sub-optimal. Many workers have used basal heart rate as one of the predictors. But ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9906-9

    authors: Prashanth A,Chakravarthy M,George A,Mayur R,Hosur R,Pargaonkar S

    更新日期:2017-08-01 00:00:00

  • The comparison of the technical parameters in endotracheal intubation devices: the Cmac, the Vividtrac, the McGrath Mac and the Kingvision.

    abstract::Currently, there are plenty of videolaryngoscopes that appear on the market. They have different specifications. Some of these features favor the fact that they are more suited for educational purposes of future operators and others can be characterized with an excellent clinical use. In this study we compared four ty...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9727-2

    authors: Cierniak M,Timler D,Wieczorek A,Sekalski P,Borkowska N,Gaszynski T

    更新日期:2016-08-01 00:00:00

  • Partitioning the resistances along the vascular tree: effects of dobutamine and hypovolemia in piglets with an intact circulation.

    abstract:OBJECTIVE:We present a new physiological model that discriminated between changes in the systemic arterial and venous circulation. To test our model, we studied the effects of dobutamine and hypovolemia in intact pentabarbital-anesthetized piglets. METHODS:Aorta pressure (Pao), central venous pressure (Pcv), mean syst...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-010-9258-9

    authors: Geerts BF,Maas JJ,Aarts LP,Pinsky MR,Jansen JR

    更新日期:2010-10-01 00:00:00