Evaluation of a computerized system for mechanical ventilation of infants.

Abstract:

OBJECTIVE:To evaluate a computerized system for mechanical ventilation of infants. METHODS:FLEX is a computerized system that includes the features of a patented mode known as adaptive-support ventilation (ASV). In addition, it has many other features including adjustment of positive end-expiratory pressure (PEEP), fraction of inspired oxygen (F(IO2)), minute ventilation, and control of weaning. It is used as an open-loop decision support system or as a closed-loop technique. Blood gas and ventilation data were collected from 12 infants in the neonatal intensive care at baseline and at the next round of evaluation. This data were input to open-loop version of FLEX. The system recommendations were compared to clinical determinations. RESULTS:FLEX recommended values for ventilation were on the average within 25% and 16.5% of the measured values at baseline and at the next round of evaluation, respectively. For F(IO2) and PEEP, FLEX recommended values were in general agreement with the clinical settings. FLEX recommendations for weaning were the same as the clinical determinations 50% of the time at baseline and 55% of the time at the next round of evaluation. FLEX did not recommend weaning for infants with weak spontaneous breathing effort or those who showed signs of dyspnea. CONCLUSIONS:A computerized system for mechanical ventilation is evaluated for treatment of infants. The results of the study show that the system has good potential for use in neonatal ventilatory care. Further refinements can be made in the system for very low-birth-weight infants.

journal_name

J Clin Monit Comput

authors

Tehrani FT,Abbasi S

doi

10.1007/s10877-009-9170-3

subject

Has Abstract

pub_date

2009-04-01 00:00:00

pages

93-104

issue

2

eissn

1387-1307

issn

1573-2614

journal_volume

23

pub_type

杂志文章
  • Predictive data mining on monitoring data from the intensive care unit.

    abstract::The widespread implementation of computerized medical files in intensive care units (ICUs) over recent years has made available large databases of clinical data for the purpose of developing clinical prediction models. The typical intensive care unit has several information sources from which data is electronically co...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-012-9416-3

    authors: Güiza F,Van Eyck J,Meyfroidt G

    更新日期:2013-08-01 00:00:00

  • Comparison between pulse wave velocities measured using Complior and measured using Biopac.

    abstract::Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0165-9

    authors: van Velzen MHN,Stolker RJ,Loeve AJ,Niehof SP,Mik EG

    更新日期:2019-04-01 00:00:00

  • Continuous hemoglobin and plethysmography variability index monitoring can modify blood transfusion practice and is associated with lower mortality.

    abstract::To determine the effect of implementing an algorithm of fluid and blood administration based on continuous monitoring of hemoglobin (SpHb) and PVI (plethysmography variability index) on mortality and transfusion on a whole hospital scale. This single-center quality program compared transfusion at 48 h and mortality at...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00367-z

    authors: Cros J,Dalmay F,Yonnet S,Charpentier M,Tran-Van-Ho J,Renaudeau F,Drouet A,Guilbaut P,Marin B,Nathan N

    更新日期:2020-08-01 00:00:00

  • Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique.

    abstract:OBJECTIVES:Bioreactance, the analysis of intrabeat variations in phase of a transthoracic voltage in response to an applied high frequency transthoracic current, was recently introduced for noninvasive cardiac output measurement (NICOM). We evaluated NICOM compared to thermo- dilution (TD) in several clinical settings....

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s10877-008-9112-5

    authors: Raval NY,Squara P,Cleman M,Yalamanchili K,Winklmaier M,Burkhoff D

    更新日期:2008-04-01 00:00:00

  • Observational study of newborn infant parasympathetic evaluation as a comfort system in awake patients admitted to a pediatric intensive care unit.

    abstract::To compare the newborn infant parasympathetic evaluation system (NIPE) scores with a validated clinical scale using two different nebulizers in children with bronchiolitis admitted to a PICU. Comfort was evaluated using the COMFORT-behavior scale (CBS) before (T1), during (T2) and after (T3) each nebulization. In orde...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-019-00268-1

    authors: Valencia-Ramos J,Arnaez J,Calvo S,Gomez F,Del Blanco I

    更新日期:2019-10-01 00:00:00

  • Heart rate variability analysis during central hypovolemia using wavelet transformation.

    abstract::Detection of hypovolemia prior to overt hemodynamic decompensation remains an elusive goal in the treatment of critically injured patients in both civilian and combat settings. Monitoring of heart rate variability has been advocated as a potential means to monitor the rapid changes in the physiological state of hemorr...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9434-9

    authors: Ji SY,Belle A,Ward KR,Ryan KL,Rickards CA,Convertino VA,Najarian K

    更新日期:2013-06-01 00:00:00

  • Are automated blood pressure monitors accurate enough to calculate the ankle brachial pressure index?

    abstract:OBJECTIVE:Conventional sphygmomanometers are being replaced by automated devices; can they be used to accurately calculate ABPI? METHOD:Thirty-six volunteers (72 legs) attending a vascular clinic had their ankle, brachial blood pressure and ABPIs calculated using each of these 3 methods. (1) Conventional aneuroid BP c...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9146-8

    authors: MacDonald E,Froggatt P,Lawrence G,Blair S

    更新日期:2008-10-01 00:00:00

  • Infrared transmission of electronic information via LAN in the operating room.

    abstract::Recent advances in technology have brought many kinds of monitoring devices into the operating room (OR). The information gathered by monitors can be channeled to the operating ward information system via a local area network (LAN). Connecting patients to monitors and monitors to the LAN, however, requires a large num...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009911208828

    authors: Hagihira S,Takashina M,Mori T,Taenaka N,Mashimo T,Yoshiya I

    更新日期:2000-01-01 00:00:00

  • Machine learning applied to multi-sensor information to reduce false alarm rate in the ICU.

    abstract::Studies reveal that the false alarm rate (FAR) demonstrated by intensive care unit (ICU) vital signs monitors ranges from 0.72 to 0.99. We applied machine learning (ML) to ICU multi-sensor information to imitate a medical specialist in diagnosing patient condition. We hypothesized that applying this data-driven approa...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00307-x

    authors: Hever G,Cohen L,O'Connor MF,Matot I,Lerner B,Bitan Y

    更新日期:2020-04-01 00:00:00

  • The impact of systemic vascular resistance on the accuracy of the FloTrac/Vigileo™ system in the perioperative period of cardiac surgery: a prospective observational comparison study.

    abstract::FloTrac/Vigileo™ system is based on arterial pressure waveform analysis arterial pressure-based CO (APCO). Therefore, systemic vascular resistance (SVR) can influence the accuracy of APCO. The purpose of this study is to evaluate the relationship between SVR and the accuracy of APCO. We managed 50 consecutive patients...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9481-2

    authors: Sotomi Y,Iwakura K,Higuchi Y,Abe K,Yoshida J,Masai T,Fujii K

    更新日期:2013-12-01 00:00:00

  • Head eye co-ordination using simultaneous measurement of eye in head and head in space movements: potential for use in subjects with a whiplash injury.

    abstract:OBJECTIVE:Describe reproducibility of a measurement method to investigate deficits in eye-head co-ordination. METHODS:Combined recordings of head and eye rotation using wireless motion sensors and electro-oculography (EOG) were used as an initial step towards a method to quantify eye-head co-ordination deficits. Head ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9160-5

    authors: Grip H,Jull G,Treleaven J

    更新日期:2009-02-01 00:00:00

  • Atypical "tails-up" capnograph due to breach in the sampling tube of side-stream capnometer.

    abstract:OBJECTIVE:An atypical "tails-up" capnograph pattern was noticed in a patient during the use of an accidentally crushed sampling tube with a slit-like hole. We investigated the mechanics involved in the observed capnograph pattern. METHODS:Forty consenting ASA I patients of both sexes presenting for tonsillectomy were ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009990210114

    authors: Tripathi M,Pandey M

    更新日期:2000-01-01 00:00:00

  • Determining the artifact sensitivity of recent pulse oximeters during laboratory benchmarking.

    abstract::This study aimed to investigate and compare the performance of the algorithms contained in the newest generation of pulse oximeters (Masimo SET in IVY2000, Nellcor Oxismart N-3000, Agilent M3 rev. B) against a traditional pulse oximeter (Agilent CMS rel. A.0). The benchmark was performed in an efficient and reproducib...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1011420228523

    authors: Kästle SW,Konecny E

    更新日期:2000-01-01 00:00:00

  • BAEPs averaging analysis using autoregressive modelling.

    abstract:OBJECTIVE:The present paper introduces a new perspective on the classical ensemble averaging which can be useful to analyse the Brainstem Auditory Evoked Potentials (BAEPs). The analysis of the dynamics, related to the BAEP, is performed directly after its acquisition from the electroencephalogram (EEG). METHODS:The m...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000042919.04719.a7

    authors: Vannier E,Naït-Ali A

    更新日期:2004-06-01 00:00:00

  • Composite-, plain-auditory evoked potentials index and bispectral index to measure the effects of sevoflurane.

    abstract::The composite auditory evoked potentials index (cAAI) uses both cortical electroencephalogram (EEG) and response to auditory stimuli, while the bispectral index (BIS) uses only the cortical EEG and auditory evoked potentials index (AAI) uses only response to auditory stimuli. We expected that the cAAI was more useful ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-013-9441-x

    authors: Nishiyama T

    更新日期:2013-06-01 00:00:00

  • Using physiological models and decision theory for selecting appropriate ventilator settings.

    abstract:OBJECTIVE:To present a decision support system for optimising mechanical ventilation in patients residing in the intensive care unit. METHODS:Mathematical models of oxygen transport, carbon dioxide transport and lung mechanics are combined with penalty functions describing clinical preference toward the goals and side...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-006-9049-5

    authors: Rees SE,Allerød C,Murley D,Zhao Y,Smith BW,Kjaergaard S,Thorgaard P,Andreassen S

    更新日期:2006-12-01 00:00:00

  • Computerized tests to evaluate recovery of cognitive function after deep sedation with propofol and remifentanil for colonoscopy.

    abstract::The use of sedation for diagnostic procedures including gastrointestinal endoscopy is rapidly growing. Recovery of cognitive function after sedation is important because it would be important for most patients to resume safe, normal life soon after the procedure. Computerized tests have shown being accurate descriptor...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0134-3

    authors: Borrat X,Ubre M,Risco R,Gambús PL,Pedroso A,Iglesias A,Fernandez-Esparrach G,Ginés À,Balust J,Martínez-Palli G

    更新日期:2019-02-01 00:00:00

  • The sound intensity and characteristics of variable-pitch pulse oximeters.

    abstract:OBJECTIVE:Various studies worldwide have found that sound levels in hospitals significantly exceed the World Health Organization (WHO) guidelines, and that this noise is associated with audible signals from various medical devices. The pulse oximeter is now widely used in health care; however the health effects associa...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9125-0

    authors: Yamanaka H,Haruna J,Mashimo T,Akita T,Kinouchi K

    更新日期:2008-06-01 00:00:00

  • Non-stationarity of EEG during wakefulness and anaesthesia: advantages of EEG permutation entropy monitoring.

    abstract::Monitors evaluating the electroencephalogram (EEG) to determine depth of anaesthesia use spectral analysis approaches for analysis windows up to 61.5 s as well as additional smoothing algorithms. Stationary EEG is required to reliably apply the index algorithms. Because of rapid physiological changes, artefacts, etc.,...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-014-9553-y

    authors: Kreuzer M,Kochs EF,Schneider G,Jordan D

    更新日期:2014-12-01 00:00:00

  • An algorithm for the detection of individual breaths from the pulse oximeter waveform.

    abstract:OBJECTIVES:To determine if wavelet analysis techniques can be used to reliably identify individual breaths from the photoplethysmogram (PPG). METHODS:Photoplethysmograms were obtained from 22 healthy adult volunteers timing their respiration rate in synchronisation with a metronome. A secondary timing signal was obtai...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-2697-z

    authors: Leonard P,Grubb NR,Addison PS,Clifton D,Watson JN

    更新日期:2004-12-01 00:00:00

  • The use of heart rate variability measures as indicators of autonomic nervous modulation must be careful in patients after orthotopic heart transplantation.

    abstract::The precise relation between heart rate variability (HRV) and autonomic re-innervation has not been established explicitly in patients after orthotopic heart transplantation (OHT), but can be inferred from the fact that the HRV is reduced immediately after OHT and may increase gradually with time. The aim of this stud...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9747-y

    authors: Lu WA,Chen GY,Shih CC,Kuo CD

    更新日期:2016-10-01 00:00:00

  • Non-invasive electrical cardiometry cardiac output monitoring during prehospital helicopter emergency medical care: a feasibility study.

    abstract:PURPOSE:Introducing advanced hemodynamic monitoring might be beneficial during Helicopter Emergency Medical Service (HEMS) care. However, it should not increase the on-scene-time, it should be easy to use and should be non-invasive. The goal of this study was to investigate the feasibility of non-invasive cardiac outpu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-021-00657-5

    authors: Slagt C,Servaas S,Ketelaars R,van Geffen GJ,Tacken MCT,Verrips CA,Baggen LAM,Scheffer GJ,van Eijk LT

    更新日期:2021-01-23 00:00:00

  • Detection of intratracheal accumulation of thick secretions by using continuous monitoring of respiratory acoustic spectrum: a preliminary analysis.

    abstract::The accumulation of tracheobronchial secretions may contribute to a deterioration in pulmonary function and its early detection is important. In this study, we analyzed the respiratory sound spectrum in patients with intratracheal secretion, and compared acoustic characteristics before and after therapeutic endotrache...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00359-z

    authors: Moon YJ,Bechtel AJ,Kim SH,Kim JW,Thiele RH,Blank RS

    更新日期:2020-08-01 00:00:00

  • COVID-19: Pulse oximeters in the spotlight.

    abstract::From home to intensive care units, innovations in pulse oximetry are susceptible to improve the monitoring and management of patients developing acute respiratory failure, and particularly those with the coronavirus disease 2019 (COVID-19). They include self-monitoring of oxygen saturation (SpO2) from home, continuous...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 社论

    doi:10.1007/s10877-020-00550-7

    authors: Michard F,Shelley K,L'Her E

    更新日期:2020-06-23 00:00:00

  • Ephedrine and phenylephrine induce opposite changes in cerebral and paraspinal tissue oxygen saturation, measured with near-infrared spectroscopy: a randomized controlled trial.

    abstract::While the effects of phenylephrine (PE) and ephedrine (E) on cerebral oxygen saturation (rScO2) already has been studied, the effect on paraspinal oxygen saturation (rSpsO2) is still unexplored. This study aims to assess the effect of PE and E on rScO2 and rSpsO2, measured with near-infrared spectroscopy. A randomized...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00328-6

    authors: Vanpeteghem CM,Bruneel BY,Lecoutere IM,De Hert SG,Moerman AT

    更新日期:2020-04-01 00:00:00

  • Effects of intraoperative positive end-expiratory pressure optimization on respiratory mechanics and the inflammatory response: a randomized controlled trial.

    abstract::Applying lung protective mechanical ventilation (LPV) during general anaesthesia even in patients with non-injured lungs is recommended. However, the effects of an individual PEEP-optimisation on respiratory mechanics, oxygenation and their potential correlation with the inflammatory response and postoperative complic...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00519-6

    authors: Ruszkai Z,Kiss E,László I,Bokrétás GP,Vizserálek D,Vámossy I,Surány E,Buzogány I,Bajory Z,Molnár Z

    更新日期:2020-05-09 00:00:00

  • Risk factors for positioning-related somatosensory evoked potential changes in 3946 spinal surgeries.

    abstract::The goal of this study was to evaluate the risk factors associated with positioning-related SSEP changes (PRSC). The study investigated the association between 18 plausible risk factors and the occurrence of intraoperative PRSC. Risk factors investigated included demographic variables, comorbidities, and procedure rel...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0148-x

    authors: Melachuri SR,Balzer JR,Melachuri MK,Ninaci D,Anetakis K,Kaur J,Crammond DJ,Thirumala PD

    更新日期:2019-04-01 00:00:00

  • Perioperative echocardiography-guided hemodynamic therapy in high-risk patients: a practical expert approach of hemodynamically focused echocardiography.

    abstract::The number of high-risk patients undergoing surgery is growing. To maintain adequate hemodynamic functioning as well as oxygen delivery to the vital organs (DO2) amongst this patient population, a rapid assessment of cardiac functioning is essential for the anesthesiologist. Pinpointing any underlying cardiovascular p...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-020-00534-7

    authors: Trauzeddel RF,Ertmer M,Nordine M,Groesdonk HV,Michels G,Pfister R,Reuter D,Scheeren TWL,Berger C,Treskatsch S

    更新日期:2020-05-26 00:00:00

  • Pulmonary air embolism.

    abstract::Pulmonary air embolism is a well-known consequence of surgery, trauma, diving, and aviation. This article reviews the physiological effects, means of detection and methods of prevention and treatment of pulmonary air embolism. The primary physiological effects are elevated pulmonary artery pressures, increased ventila...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1023/a:1011455701892

    authors: Souders JE

    更新日期:2000-01-01 00:00:00

  • Time-variant investigation of quadratic phase couplings caused by amplitude modulation in electroencephalic burst-suppression patterns.

    abstract:OBJECTIVE:Several studies suggest that parameters derived from bispectral analysis of the EEG can be used to characterize specific cortical activation states represented by non linear interaction between brain electrical oscillations. For example, it was shown that so-called bispectral indices can be used to assess the...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1016362209175

    authors: Arnold M,Witte H,Schelenz C

    更新日期:2002-02-01 00:00:00