Comparison of haemodynamic- and electroencephalographic-monitored effects evoked by four combinations of effect-site concentrations of propofol and remifentanil, yielding a predicted tolerance to laryngoscopy of 90.

Abstract:

:This prospective study evaluates haemodynamic and electroencephalographic effects observed when administering four combinations of effect-site concentrations of propofol (CePROP) and remifentanil (CeREMI), all yielding a single predicted probability of tolerance of laryngoscopy of 90% (PTOL = 90%) according to the Bouillon interaction model. We aimed to identify combinations of CePROP and CeREMI along a single isobole of PTOL that result in favourable hypnotic and haemodynamic conditions. This knowledge could be of advantage in the development of drug advisory monitoring technology. 80 patients (18-90 years of age, ASA I-III) were randomized into four groups and titrated towards CePROP (Schnider model, ug⋅ml-1) and CeREMI (Minto model, ng⋅ml-1) of respectively 8.6 and 1, 5.9 and 2, 3.6 and 4 and 2.0 and 8. After eleven minutes of equilibration, baseline measurements of haemodynamic endpoints and bispectral index were compared with three minutes of responsiveness measurements after laryngoscopy. Before laryngoscopy, bispectral index differed significantly (p < 0.0001) between groups in concordance with CePROP. Heart rate decreased with increasing CeREMI (p = 0.001). The haemodynamic and arousal responses evoked by laryngoscopy were not significantly different between groups, but CePROP = 3.6 μg⋅ml-1 and CeREMI = 4 ng⋅ml-1 evoked the lowest median value for ∆HR and ∆SAP after laryngoscopy. This study provides clinical insight on the haemodynamic and hypnotic consequences, when a model based predicted PTOL is used as a target for combined effect-site controlled target- controlled infusion of propofol and remifentanil. Heart rate and bispectral index were significantly different between groups despite a theoretical equipotency for PTOL, suggesting that each component of the anaesthetic state (immobility, analgesia, and hypnotic drug effect) should be considered as independent neurophysiological and pharmacological phenomena. However, claims of (in)accuracy of the predicted PTOL must be considered preliminary because larger numbers of observations are required for that goal.

journal_name

J Clin Monit Comput

authors

van den Berg JP,Absalom AR,Venema AM,Kalmar AF,Van Amsterdam K,Hannivoort LN,Proost JH,Meier S,Scheeren TWL,Struys MMRF,Vereecke HEM

doi

10.1007/s10877-020-00540-9

subject

Has Abstract

pub_date

2020-06-03 00:00:00

eissn

1387-1307

issn

1573-2614

pii

10.1007/s10877-020-00540-9

pub_type

杂志文章
  • Monitoring the microcirculation.

    abstract::One of the main goals of hemodynamic support is to preserve tissue perfusion. However issue perfusion is related more to microvascular perfusion than aortic blood flow. Monitoring the microcirculation has long been difficult. Recent technologic advances have made feasible monitoring of the microcirculation at bedside ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-012-9383-8

    authors: De Backer D,Donadello K,Cortes DO

    更新日期:2012-10-01 00:00:00

  • Comparison of Univent tube and EZ blocker in one lung ventilation; airway pressures and gas exchange.

    abstract::Univent tube (UT) and EZ-blocker were used for one-lung ventilation (OLV). UT is a single lumen tube with a small separate lumen containing a bronchial blocker. EZ-blocker differs with its unique y-shaped double-cuffed distal end. We aimed to compare these two airway devices effects on airway pressures, oxygenation, v...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-017-0028-9

    authors: Hoşten T,Aksu C,Kuş A,Cesur S,Türkyılmaz N,Solak M

    更新日期:2018-04-01 00:00:00

  • Utility of near infrared light to determine tissue oxygenation during hepato-biliary surgery.

    abstract::Near-infrared spectrophotometry assesses cerebral oxygen saturation (ScO2) based on the absorption spectra of oxygenated and deoxygenated hemoglobin, and the translucency of biological tissue, in the near-infrared band. There is increasing evidence that optimising cerebral oxygenation, guided by ScO2, is associated wi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9642-y

    authors: Murphy N,Fröhlich S,Kong T,Boylan JF,Conlon N

    更新日期:2015-10-01 00:00:00

  • Selection of cuffed endotracheal tube for children with congenital heart disease based on an ultrasound-based linear regression formula.

    abstract::It remains to be discovered whether a formula predicting the subglottic transverse diameter measured by ultrasound (SGDformula) for the selection of an appropriate endotracheal tube (ETT) for children without congenital heart disease (CHD) is useful for children with CHD. A formula for predicting SGD was established a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0203-7

    authors: Zhang K,Ma RJ,Zheng JJ,Chen YQ,Zhang MZ

    更新日期:2019-08-01 00:00:00

  • EEG sources of noise in intraoperative somatosensory evoked potential monitoring during propofol anesthesia.

    abstract:OBJECTIVE:It was hypothesized that somato- sensory evoked potentials can be achieved faster by selective averaging during periods of low spontaneous electroen- cephalographic (EEG) activity. We analyzed the components of EEG that decrease the signal-to-noise ratio of somatosensory evoked potential (SEP) recordings duri...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9188-6

    authors: Joutsen A,Puumala P,Lyytikäinen LP,Pajulo O,Etelämäki A,Eskola H,Jäntti V

    更新日期:2009-08-01 00:00:00

  • Infrared transmission of electronic information via LAN in the operating room.

    abstract::Recent advances in technology have brought many kinds of monitoring devices into the operating room (OR). The information gathered by monitors can be channeled to the operating ward information system via a local area network (LAN). Connecting patients to monitors and monitors to the LAN, however, requires a large num...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009911208828

    authors: Hagihira S,Takashina M,Mori T,Taenaka N,Mashimo T,Yoshiya I

    更新日期:2000-01-01 00:00:00

  • Bilobed splitting of median nerve somatosensory evoked p14 potential under deep hypothermia.

    abstract:OBJECTIVE:To further elucidate temperature related changes in subcortical components of somatosensory evoked potentials (SEP) in intraoperative monitoring. METHODS:Intraoperative monitoring of subcortical median nerve SEP under deep hypothermia is described in a patient undergoing intracranial giant aneurysm surgery. ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1020792729242

    authors: Wagner W

    更新日期:2002-04-01 00:00:00

  • Investigation of optical neuro-monitoring technique for detection of maintenance and emergence states during general anesthesia.

    abstract::The American Society of Anesthesiologist recommends peripheral physiological monitoring during general anesthesia, which offers no information regarding the effects of anesthetics on the brain. Since no "gold standard" method exists for this evaluation, such a technique is needed to ensure patient comfort, procedure q...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-9998-x

    authors: Hernandez-Meza G,Izzetoglu M,Osbakken M,Green M,Abubakar H,Izzetoglu K

    更新日期:2018-02-01 00:00:00

  • Intraoperative electrode burns.

    abstract:OBJECTIVES:The purpose of this paper is to increase awareness of electrode burns that occur in the operating room (OR), to discuss their causes, warning signs, and methods that may reduce their occurrence. Two general sources of electrical burns are described: 1) Excessive radio-frequency current density usually origin...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000025254.73456.db

    authors: Russell MJ,Gaetz M

    更新日期:2004-02-01 00:00:00

  • A simplified 4-parameter model of volumetric capnograms improves calculations of airway dead space and slope of Phase III.

    abstract::To evaluate a compact and easily interpretable 4-parameter model describing the shape of the volumetric capnogram, and the resulting estimates of anatomical dead space (VDAW) and Phase III (alveolar plateau) slope (SIII). Data from of 8 mildly-endotoxemic pre-acute respiratory distress syndrome sheep were fitted to th...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00451-4

    authors: Motta-Ribeiro GC,Vidal Melo MF,Jandre FC

    更新日期:2020-12-01 00:00:00

  • Diagnosis of anesthetic-induced upper airway obstruction in children using respiratory inductance plethysmography.

    abstract:OBJECTIVE:Upper airway obstruction is the most rapid and clinically relevant cause of hypoxia during sedation and anesthesia. This study was designed to determine if respiratory inductance plethysmography (RIP) could quantify the degree of upper airway obstruction caused by induction of general anesthesia. METHODS:RIP...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1021246119194

    authors: Litman RS,Kottra JA,Gallagher PR,Ward DS

    更新日期:2002-07-01 00:00:00

  • Time-variant investigation of quadratic phase couplings caused by amplitude modulation in electroencephalic burst-suppression patterns.

    abstract:OBJECTIVE:Several studies suggest that parameters derived from bispectral analysis of the EEG can be used to characterize specific cortical activation states represented by non linear interaction between brain electrical oscillations. For example, it was shown that so-called bispectral indices can be used to assess the...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1016362209175

    authors: Arnold M,Witte H,Schelenz C

    更新日期:2002-02-01 00:00:00

  • Clinical evaluation of stretchable and wearable inkjet-printed strain gauge sensor for respiratory rate monitoring at different measurements locations.

    abstract::The respiration rate (RR) is a vital sign in physiological measurement and clinical diagnosis. RR can be measured using stretchable and wearable strain gauge sensors which detect the respiratory movements in the abdomen or thorax areas caused by volumetric changes. In different body locations, the accuracy of RR detec...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00481-3

    authors: Al-Halhouli A,Al-Ghussain L,El Bouri S,Liu H,Zheng D

    更新日期:2020-02-22 00:00:00

  • Determining the artifact sensitivity of recent pulse oximeters during laboratory benchmarking.

    abstract::This study aimed to investigate and compare the performance of the algorithms contained in the newest generation of pulse oximeters (Masimo SET in IVY2000, Nellcor Oxismart N-3000, Agilent M3 rev. B) against a traditional pulse oximeter (Agilent CMS rel. A.0). The benchmark was performed in an efficient and reproducib...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1011420228523

    authors: Kästle SW,Konecny E

    更新日期:2000-01-01 00:00:00

  • Cardioplegia and ventricular late potentials in cardiac surgical patients.

    abstract:BACKGROUND AND OBJECTIVE:Ventricular late potentials (LP) recording with signal-averaged electrocar- diogram allow identifying patients at risk of sudden death and ventricular tachycardia. Cardiac surgery with cardiopulmonary bypass (CPB) could predispose to the development of myocardial ischemia related to imperfect c...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-011-9305-1

    authors: Schütz N,Romand JA,Yanez ND,Treggiari MM,Bendjelid K

    更新日期:2011-08-01 00:00:00

  • A fully automated algorithm for the determination of respiratory rate from the photoplethysmogram.

    abstract:OBJECTIVE:To determine if an automatic algorithm using wavelet analysis techniques can be used to reliably determine respiratory rate from the photoplethysmogram (PPG). METHODS:Photoplethysmograms were obtained from 12 spontaneously breathing healthy adult volunteers. Three related wavelet transforms were automaticall...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9007-7

    authors: Leonard PA,Douglas JG,Grubb NR,Clifton D,Addison PS,Watson JN

    更新日期:2006-02-01 00:00:00

  • Right ventricular function in late-onset Pompe disease.

    abstract::Pompe's disease is a glycogen storage disease (type II) characterized by inherited autosomal recessive transmission. The right ventricular (RV) function is a determinant parameter of clinical outcome in patients with heart failure. We sought to characterize the RV function using Doppler-echocardiography completed by D...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9551-0

    authors: Fayssoil A,Nardi O,Annane D,Orlikowski D

    更新日期:2014-08-01 00:00:00

  • SNAP II versus BIS VISTA monitor comparison during general anesthesia.

    abstract:INTRODUCTION:Effectively monitoring the level of consciousness during general anesthesia is clinically beneficial to both the patient and the physician. An electroencephalogram (EEG)-based level-of-consciousness monitor can help minimize intraoperative awareness as well as the effects of over-sedation. In this study, w...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-010-9246-0

    authors: Hrelec C,Puente E,Bergese S,Dzwonczyk R

    更新日期:2010-08-01 00:00:00

  • The influence of basic ventilation strategies on cerebral oxygenation in anesthetized patients without vascular disease.

    abstract:OBJECTIVES:Optimizing cerebral oxygenation is of paramount importance in certain intraoperative situations. There is, however, a paucity of published data pertaining to changes in cerebral oxygenation seen with increases in the inspired fraction of oxygen (FIO2) or end-tidal carbon dioxide (PETCO2) in anesthetized pati...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-010-9265-x

    authors: Picton P,Shanks A,Dorje P,Mashour GA

    更新日期:2010-12-01 00:00:00

  • The American Society of Neurophysiological Monitoring position statements project.

    abstract::The American Society of Neurophysiological Monitoring (ASNM) is developing position statements aimed at assisting practitioners and others in making decisions regarding neurophysiological monitoring practice. This paper describes the procedures used in drafting these documents. ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9000-1

    authors: Morledge DE,Stecker M

    更新日期:2006-02-01 00:00:00

  • USCOM-window to the circulation: utility of supra-sternal Doppler in an elderly anaesthetized patient for a robotic cystectomy.

    abstract::Supra-sternal Doppler (USCOM Ltd., Sydney, Australia) can be used during anaesthesia to measure cardiac output (CO) and related flow parameters. However, before the USCOM can be used routinely, its utility and limitations need to be fully understood and critical information about its use disseminated. In "Window to th...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9499-5

    authors: Critchley LA,Huang L

    更新日期:2014-02-01 00:00:00

  • Design and α-testing of an electronic rounding tool (CERTAINp) to improve process of care in pediatric intensive care unit.

    abstract::Increasing process complexity in the pediatric intensive care unit (PICU) can lead to information overload resulting in missing pertinent information and potential errors during morning rounds. An efficient model using a novel electronic rounding tool was designed as part of a broader critical care decision support sy...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9946-1

    authors: Hulyalkar M,Gleich SJ,Kashyap R,Barwise A,Kaur H,Dong Y,Fan L,Murthy S,Arteaga GM,Tripathi S

    更新日期:2017-12-01 00:00:00

  • Transcranial Doppler monitoring compared with invasive monitoring of intracranial pressure during acute intracranial hypertension.

    abstract:OBJECTIVE:To determine whether a simple transcanial Doppler waveform variable-pulsatility difference (systolic - diastolic blood flow velocity) can serve as a measure of critical changes in cerebral perfusion. METHODS:Thirteen pigs were anesthetized (anesthesia maintained with halothane) and ventilated to maintain nor...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009993232534

    authors: Sidi A,Messinger G,Mahla ME

    更新日期:1999-05-01 00:00:00

  • Dynamic prediction of the need for renal replacement therapy in intensive care unit patients using a simple and robust model.

    abstract::We aimed at identifying a model that dynamically predicts future need for renal replacement therapy (RRT) in intensive care unit (ICU) patients and can easily be implemented for online monitoring at the bedside. 7290 interdisciplinary ICU admissions were investigated. Patients with <3 days of stay or RRT in the first ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9814-4

    authors: Erdfelder F,Grigutsch D,Hoeft A,Reider E,Matot I,Zenker S

    更新日期:2017-02-01 00:00:00

  • Capnography to check the safety of Bain circuit.

    abstract::The test of the inner tube integrity is an important checklist prior to the safe use of Bain's breathing system. This is because the major concern with the use of Bain's circuit is the potential malfunctioning of the circuit due to avulsion of the inner fresh gas delivery tube at the machine end which will turn the ou...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9212-x

    authors: Kataria S,Subramanyam R

    更新日期:2010-02-01 00:00:00

  • Cardiac output measurement by pulse dye densitometry: comparison with pulmonary artery thermodilution in post-cardiac surgery patients.

    abstract:OBJECTIVE:Pulse-dye densitometry (PDD) could be a suitable, low-invasive alternative to thermodilution using a pulmonary artery catheter (PAC) for monitoring cardiac output. The aim of our study was to assess the reproducibility and validity of PDD compared to PAC-thermodilution. METHODS:In 43 post-cardiac surgery pat...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-6865-y

    authors: Kroon M,Groeneveld AB,Smulders YM

    更新日期:2005-12-01 00:00:00

  • Comparison between two mathematical methods to estimate arterial occlusion pressure and tourniquet effectiveness in lower limb surgery: a prospective, randomized, double blind, comparative study.

    abstract::The effectiveness of two different methods for calculating the arterial occlusion pressure (AOP) to set tourniquet inflation pressures were assessed in patients underwent knee arthroscopy. Eighty patients were included in this study. Tourniquet inflation pressure was set by adding 20 mmHg of safety margin above the AO...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00366-0

    authors: Kasem SA,Al Menesy T,Badawy AA,Abd Elmawgoud A,Adel G,Badawy YA

    更新日期:2020-08-01 00:00:00

  • Eye lens dosimetry in anesthesiology: a prospective study.

    abstract::The eye lens is one of the most sensitive organs for radiation injury and exposure might lead to radiation induced cataract. Eye lens dosimetry in anesthesiology has been published in few clinical trials and an active debate about the causality of radiation induced cataract is still ongoing. Recently, the Internationa...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9857-1

    authors: Vaes B,Van Keer K,Struelens L,Schoonjans W,Nijs I,Vandevenne J,Van Poucke S

    更新日期:2017-04-01 00:00:00

  • Electrical impedance tomography's correlation to lung volume is not influenced by anthropometric parameters.

    abstract:STUDY OBJECTIVES:Electrical impedance tomography (EIT) is able to reflect physiological parameters such as real-time changes in global and regional lung volume. EIT can aid in the assessment of lung recruitment, and its use has been validated in preliminary studies monitoring mechanical ventilation at the bedside. ICU ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-006-9021-4

    authors: Marquis F,Coulombe N,Costa R,Gagnon H,Guardo R,Skrobik Y

    更新日期:2006-06-01 00:00:00

  • Unconsciousness indication using time-domain parameters extracted from mid-latency auditory evoked potentials.

    abstract:OBJECTIVE:The mid-latency auditory evoked potential (MLAEP) has been used to indicate depth of anaesthesia, and is usually analysed in time-domain. This work compares three techniques: Wave Deformation Parameters (PDO), Auditory Evoked Potential Index (AEPidx) and an automatic Nb-wave latency estimator (Nb), in the ass...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1023/a:1024208827407

    authors: Cagy M,Infantosi AF

    更新日期:2002-08-01 00:00:00