Abstract:
:The use of processed electroencephalography (EEG) using a simple frontal lead system has been made available for assessing the impact of anesthetic medications during surgery. This review discusses the basic principles behind these devices. The foundations of anesthesia monitoring rest on the observations of Guedel with ether that the depth of anesthesia relates to the cortical, brainstem and spinal effects of the anesthetic agents. Anesthesiologists strive to have a patient who is immobile, is unconscious, is hemodynamically stable and who has no intraoperative awareness or recall. These anesthetic management principles apply today, despite the absence of ether from the available anesthetic medications. The use of the EEG as a supplement to the usual monitoring techniques rests on the observation that anesthetic medications all alter the synaptic function which produces the EEG. Frontal EEG can be viewed as a surrogate for the drug effects on the entire central nervous system (CNS). Using mathematical processing techniques, commercial EEG devices create an index usually between 0 and 100 to characterize this drug effect. Critical aspects of memory formation occur in the frontal lobes making EEG monitoring in this area a possible method to assess risk of recall. Integration of processed EEG monitoring into anesthetic management is evolving and its ability to characterize all of the anesthetic effects on the CNS (in particular awareness and recall) and improve decision making is under study.
journal_name
J Clin Monit Computjournal_title
Journal of clinical monitoring and computingauthors
Jameson LC,Sloan TBdoi
10.1007/s10877-006-9044-xsubject
Has Abstractpub_date
2006-12-01 00:00:00pages
445-72issue
6eissn
1387-1307issn
1573-2614journal_volume
20pub_type
杂志文章,评审abstract::Audible pulse tones, based on a variable-pitch frequency scale, allow the anesthesiologist to determine the patient's oxygen saturation without constant visual examination of the monitor display. The ability to reliably detect oxygen saturation levels based on audible pulse tones may be compromised when multiple pulse...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/b:jocm.0000032698.47717.06
更新日期:2004-04-01 00:00:00
abstract::Hypothermia is a common perioperative complication. To prevent perioperative hypothermia amongst other things electrical heating mattresses are used. We have made an observation with the use of an electrical heating mattress that may confuse users. In this case the ECG monitoring suddenly showed spikes that looked lik...
journal_title:Journal of clinical monitoring and computing
pub_type: 信件
doi:10.1007/s10877-020-00520-z
更新日期:2020-07-15 00:00:00
abstract::The respiration rate (RR) is a vital sign in physiological measurement and clinical diagnosis. RR can be measured using stretchable and wearable strain gauge sensors which detect the respiratory movements in the abdomen or thorax areas caused by volumetric changes. In different body locations, the accuracy of RR detec...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00481-3
更新日期:2020-02-22 00:00:00
abstract:OBJECTIVE:The present paper introduces a new perspective on the classical ensemble averaging which can be useful to analyse the Brainstem Auditory Evoked Potentials (BAEPs). The analysis of the dynamics, related to the BAEP, is performed directly after its acquisition from the electroencephalogram (EEG). METHODS:The m...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/b:jocm.0000042919.04719.a7
更新日期:2004-06-01 00:00:00
abstract::To compare the newborn infant parasympathetic evaluation system (NIPE) scores with a validated clinical scale using two different nebulizers in children with bronchiolitis admitted to a PICU. Comfort was evaluated using the COMFORT-behavior scale (CBS) before (T1), during (T2) and after (T3) each nebulization. In orde...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-019-00268-1
更新日期:2019-10-01 00:00:00
abstract::The Sensmart Model X-100 (Nonin Medical Inc, Plymouth, MN, USA) is a relatively new device that possesses two sets of emitters and detectors and uses near infrared spectroscopy (NIRS) to measure regional cerebral oxygen saturation (rSO2). The value of rSO2 obtained by other NIRS devices is affected by physiological an...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00567-y
更新日期:2020-07-31 00:00:00
abstract:OBJECTIVE:To evaluate a computerized system for mechanical ventilation of infants. METHODS:FLEX is a computerized system that includes the features of a patented mode known as adaptive-support ventilation (ASV). In addition, it has many other features including adjustment of positive end-expiratory pressure (PEEP), fr...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-009-9170-3
更新日期:2009-04-01 00:00:00
abstract::While the effects of phenylephrine (PE) and ephedrine (E) on cerebral oxygen saturation (rScO2) already has been studied, the effect on paraspinal oxygen saturation (rSpsO2) is still unexplored. This study aims to assess the effect of PE and E on rScO2 and rSpsO2, measured with near-infrared spectroscopy. A randomized...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00328-6
更新日期:2020-04-01 00:00:00
abstract::Compared with supine positioning, head-up positioning improves preoxygenation and prolongs the time to oxygen desaturation. We reevaluated benefits of head-up positioning using near-infrared spectroscopy (NIRS) with pulse oximetry in a pig model. Six pigs (mean ± SD weight: 25.3 ± 0.6 kg) were anesthetized with isoflu...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00456-z
更新日期:2020-01-02 00:00:00
abstract::The Nexfin device allows for non-invasive beat-to-beat blood pressure monitoring (BP(NXF)). Perioperative hypotension and hypertension have been shown to be associated with poor clinical outcomes. The goal of the present study was to assess the ability of this device to decrease the duration of significant intraoperat...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-012-9344-2
更新日期:2012-04-01 00:00:00
abstract::Changes in expired nitric oxide (NO) occur in airway inflammation and have proved to be important in the monitoring of inflammatory disease processes such as asthma. We set out to develop a novel hand-held NO-analyzer with a performance comparable to the present more costly and complex chemiluminescence instruments. T...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-1158-z
更新日期:2004-12-01 00:00:00
abstract::The goal of this study was to evaluate the risk factors associated with positioning-related SSEP changes (PRSC). The study investigated the association between 18 plausible risk factors and the occurrence of intraoperative PRSC. Risk factors investigated included demographic variables, comorbidities, and procedure rel...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0148-x
更新日期:2019-04-01 00:00:00
abstract::Loss of endotracheal cuff pressure can lead to airway compromise and loss of volume delivery in mechanical ventilation requiring immediate intervention. A 40 years old male posted for bilateral interpositional arthroplasty was intubated nasally with 7.5 mm flexometallic endotracheal tube. In the intraoperative period ...
journal_title:Journal of clinical monitoring and computing
pub_type: 信件
doi:10.1007/s10877-020-00607-7
更新日期:2020-10-23 00:00:00
abstract:OBJECTIVE:Transcranial Motor Evoked Potentials (TcMEPs) are sometimes used during lumbar spine surgery in order to detect and prevent an intraoperative nerve root injury. Typically, a fixed stimulus is applied, and one monitors for changes in response amplitude from several myotomes. Increased stimulating voltage may o...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-010-9269-6
更新日期:2010-12-01 00:00:00
abstract:OBJECTIVE:Artefact detection is an essential feature of automatic EEG monitoring systems used in anaesthesia. Clinical experience indicates that Narcotrend monitoring (MonitorTechnik, Bad Bramstedt, Germany, version 4.0) excludes more EEG epochs because of artefacts than bispectral index monitoring (BIS, Aspect Medical...
journal_title:Journal of clinical monitoring and computing
pub_type: 临床试验,杂志文章
doi:10.1007/s10877-005-2700-8
更新日期:2004-08-01 00:00:00
abstract::Obstructive sleep apnea (OSA) is a risk factor for perioperative complications, but many OSA patients present undiagnosed. While polysomnography (PSG) is the "gold standard" for diagnosis, its application is technology-intense, time-consuming, expensive, and requires specialists, often delaying surgery. Thus, miniatur...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0151-2
更新日期:2019-04-01 00:00:00
abstract::We assessed the effect of re-calibration time on cardiac output estimation and trending performance in a retrospective analysis of an intensive care unit patient population using error grid analyses. Paired thermodilution and arterial blood pressure waveform measurements (N = 2141) from 222 patient records were extrac...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9749-9
更新日期:2016-10-01 00:00:00
abstract::The optimal size selection of laryngeal mask airway (LMA) based on body weight is not always applicable. This study was prospectively conducted to evaluate the efficacy of cricoid-mental distance-based method versus weight-based method in optimal size selection of LMA in adults. Seventy-four patients (aged from 18 to ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-019-00308-w
更新日期:2019-10-01 00:00:00
abstract::Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0165-9
更新日期:2019-04-01 00:00:00
abstract:OBJECTIVE:The mid-latency auditory evoked potential (MLAEP) has been used to indicate depth of anaesthesia, and is usually analysed in time-domain. This work compares three techniques: Wave Deformation Parameters (PDO), Auditory Evoked Potential Index (AEPidx) and an automatic Nb-wave latency estimator (Nb), in the ass...
journal_title:Journal of clinical monitoring and computing
pub_type: 临床试验,杂志文章
doi:10.1023/a:1024208827407
更新日期:2002-08-01 00:00:00
abstract::To develop and validate a mathematical model for predicting intracranial pressure (ICP) noninvasively using phase-contrast cine MRI (PC-MRI). We performed a retrospective analysis of PC-MRI from patients with communicating hydrocephalus (n = 138). The patients were recruited from Shenzhen Second People's Hospital betw...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00598-5
更新日期:2020-10-01 00:00:00
abstract::Pulse pressure variation (PPV) and cardiac output (CO) can guide perioperative fluid management. Capstesia (Galenic App, Vitoria-Gasteiz, Spain) is a mobile application for snapshot pulse wave analysis (PWAsnap) and estimates PPV and CO using pulse wave analysis of a snapshot of the arterial blood pressure waveform di...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00572-1
更新日期:2020-08-04 00:00:00
abstract::Electric energy have been in use for the treatment of various ailments, including pain, since the time of Pharaohs. The theoretical basis of electrotherapy of pain was provided by the Gate Control Theory of Melzak and Wall. In 1965, Shealey et al. first introduced electrical stimulation of spinal cord for treating pai...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,评审
doi:10.1007/s10877-009-9201-0
更新日期:2009-10-01 00:00:00
abstract::Jasiukaitis and Lyon (J Clin Monit Comput, https://doi.org/10.1007/s10877-018-0181-9, 2018) described an motor evoked potential (MEP)amplitude trending system to detect MEP amplitude loss against a background of MEP variability. They found that the end of case value of a running R2 triggered by a set MEP amplitude los...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00272-5
更新日期:2020-02-01 00:00:00
abstract::Auditory steady state responses (ASSR) may offer an alternative to brainstem auditory evoked potentials for monitoring of the auditory nerve during surgical procedures. In the current study, we evaluated the influence of noise on ASSR characteristics in total intravenous anesthesia (TIVA). Simulated ASSR in real noise...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9837-5
更新日期:2017-02-01 00:00:00
abstract:OBJECTIVE:Describe reproducibility of a measurement method to investigate deficits in eye-head co-ordination. METHODS:Combined recordings of head and eye rotation using wireless motion sensors and electro-oculography (EOG) were used as an initial step towards a method to quantify eye-head co-ordination deficits. Head ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-009-9160-5
更新日期:2009-02-01 00:00:00
abstract::The test of the inner tube integrity is an important checklist prior to the safe use of Bain's breathing system. This is because the major concern with the use of Bain's circuit is the potential malfunctioning of the circuit due to avulsion of the inner fresh gas delivery tube at the machine end which will turn the ou...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-009-9212-x
更新日期:2010-02-01 00:00:00
abstract::Jaundice of the newborn is a common problem as a consequence of the rapid increment of blood bilirubin in the first days of live. In most cases, it is considered a physiological transient situation, but unmanaged hyperbilirubinemia can lead to death or serious injuries for the survivors. For decades, phototherapy has ...
journal_title:Journal of clinical monitoring and computing
pub_type: 临床试验,杂志文章
doi:10.1007/s10877-006-9016-1
更新日期:2006-06-01 00:00:00
abstract:OBJECTIVE:To test the ability of a microphone recording system, located distal to the respiratory outflow tract, to track the timing of the inspiratory and expiratory phases of breathing in awake healthy subjects. METHODS:Fifteen subjects participated. Breath sounds were recorded using a microphone embedded in a face ...
journal_title:Journal of clinical monitoring and computing
pub_type: 临床试验,杂志文章
doi:10.1007/s10877-011-9307-z
更新日期:2011-10-01 00:00:00
abstract::Given the benefit of glucose control in the perioperative period, we evaluated the accuracy and performance of the continuous glucose monitoring system (CGMS) depending on different measurement sites in the operating room (OR) and in the intensive care unit (ICU). Patients over 18 years of age scheduled for elective s...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9804-6
更新日期:2017-02-01 00:00:00