Detection of l-Methamphetamine and l-Amphetamine as Selegiline Metabolites.

Abstract:

:Selegiline (SE) is a selective, irreversible monoamine oxidase-B inhibitor, used for reducing symptoms in early-stage Parkinson's disease. The metabolites of SE include l-methamphetamine, l-amphetamine and desmethylselegiline (DSE). The stereoisomers of SE metabolites, d-methamphetamine and d-amphetamine are highly addictive psychostimulants and some of the most abused drugs in South Korea. In order to differentiate medical SE users form illicit methamphetamine abusers, it is important to distinguish between the l-isomers and d-isomers in urine samples. A 52-year-old male, seemingly under the influence of intoxication and demonstrating abnormal behavior, was reported to the police. The initial urine test using a methamphetamine detection kit demonstrated a positive result. Given the initial results, the police officer requested a further analysis of the urine sample. The urine sample was screened using headspace-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS). Both methamphetamine and amphetamine were detected, in addition to SE and DSE. To quantitate methamphetamine and amphetamine by HS-SPME-GC-MS, we performed a standard addition method due to the matrix effect of the case sample. Consistent with previous studies, our results indicated that the ratio of amphetamine to methamphetamine was 0.27, which was in the range of SE ingestion. Furthermore, we confirmed l-methamphetamine and l-amphetamine by chiral derivatization using (R)-(-)-α-methoxy-α-(trifluoromethyl) phenylacetyl chloride.

journal_name

J Anal Toxicol

authors

Shin I,Choi H,Kang S,Kim J,Park Y,Yang W

doi

10.1093/jat/bkaa058

subject

Has Abstract

pub_date

2020-05-30 00:00:00

eissn

0146-4760

issn

1945-2403

pii

5849056

pub_type

杂志文章
  • Evaluation of commercial breath-alcohol simulators: further studies.

    abstract::Exemplars of current commercial breath-alcohol simulators were studied to ascertain their suitability for control tests and as calibrators in breath-alcohol analysis. Temperature, effluent volumes and pressures, effluent-alcohol concentration, and alcohol depletion were measured for simulators coupled with various cur...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/15.5.272

    authors: Dubowski KM,Essary NA

    更新日期:1991-09-01 00:00:00

  • A method for differentiation and analysis of quinine and quinidine by gas chromatography/mass spectrometry.

    abstract::A method is presented for the positive identification of quinine and quinidine. The method requires extraction of the compounds from an alkaline solution into an organic solvent and concentration of the sample by evaporation of the solvent. The sample is chromatographed without derivatization and may be detected by th...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/5.6.275

    authors: Furner RL,Brown GB,Scott JW

    更新日期:1981-11-01 00:00:00

  • Diagnostic analysis of veterinary dried blood spots for toxic heavy metals exposure.

    abstract::Dried blood spots (DBS) on filter paper have been used in human medicine since the 1960s, predominantly for screening in-borne metabolic disorders and more recently, for toxicology. Despite its 50-year existence, this technology has not been adopted by veterinarians for routine diagnoses and research. We have validate...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkt048

    authors: Lehner AF,Rumbeiha W,Shlosberg A,Stuart K,Johnson M,Domenech R,Langner H

    更新日期:2013-09-01 00:00:00

  • Concentrations of heroin, 06-monoacetylmorphine, and morphine in a lethal case following an oral heroin overdose.

    abstract::A case of lethal overdose by heroin ingestion is presented. The concentrations of drugs were measured several hours after death. Heroin, 06-monoacetylmorphine, and morphine were identified and quantitated in blood, urine, and gastrointestinal contents by gas chromatography-mass spectrometry and high-performance liquid...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/21.3.232

    authors: Rop PP,Fornaris M,Salmon T,Burle J,Bresson M

    更新日期:1997-05-01 00:00:00

  • Preliminary evaluation of the Abbott TDx for screening of D-methamphetamine in whole blood specimens.

    abstract::The Abbott TDx Urine Amphetamine/Methamphetamine II fluorescence polarization immunoassay technique was applied to the determination of D-methamphetamine in hemolyzed whole blood. The assay was found to have 100% cross-reactivity with D-methamphetamine and only an 8% cross-reactivity with L-methamphetamine. Whole bloo...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/16.2.115

    authors: Simonick TF,Watts VW

    更新日期:1992-03-01 00:00:00

  • Alcohol analysis of stored whole-breath samples by automated gas chromatography.

    abstract::A new method was developed to apply the advantages of automated gas chromatographic headspace analysis to delayed measurement of alcohol in whole breath (W-B). End-expiratory breath and vapor-alcohol samples were collected in sealed, heated 22-mL glass vials, stored for 0-15 days, and thereafter analyzed for alcohol b...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/6.5.217

    authors: Dubowski KM,Essary NA

    更新日期:1982-09-01 00:00:00

  • Comparison of EMIT II, CEDIA, and DPC RIA assays for the detection of lysergic acid diethylamide in forensic urine samples.

    abstract::In an effort to determine a practical, efficient, and economical alternative for the use of a radioimmunoassay (RIA) for the detection of lysergic acid diethylamide (LSD) in human urine, the performance of two photometric immunoassays (Dade Behring EMIT II and Microgenics CEDIA) and the Diagnostics Products Corp. (DPC...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/26.7.519

    authors: Wiegand RF,Klette KL,Stout PR,Gehlhausen JM

    更新日期:2002-10-01 00:00:00

  • Therapeutic and toxic concentrations of mirtazapine.

    abstract::Six cases involving the antidepressant mirtazapine were analyzed in detail at the San Diego County Medical Examiner's Office from 2004 to 2005. Mirtazapine was initially detected and confirmed in each of these cases by a liquid-liquid gas chromatography (GC)-MS basic drug screen. Following another liquid-liquid basic ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/30.9.687

    authors: Kirkton C,McIntyre IM

    更新日期:2006-11-01 00:00:00

  • Postmortem morphine concentrations following use of a continuous infusion pump.

    abstract::We report a case involving unusually high postmortem morphine concentrations in a 44-year-old male with end-stage pancreatic cancer. He was receiving morphine for pain control via a single subclavian intravenous catheter. Allegations of foul play were made by family members at the time of death, so a full autopsy was ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/28.6.529

    authors: Kerrigan S,Honey D,Baker G

    更新日期:2004-09-01 00:00:00

  • Validation of a Fully Automated Immunoaffinity Workflow for the Detection and Quantification of Insulin Analogs by LC-MS-MS in Postmortem Vitreous Humor.

    abstract::The analysis of biological specimens collected at autopsy for the presence of exogenous insulin(s) is of special interest in select death investigations as they may be suspected in the cause of a death. Technical challenges include the limited stability of insulin, and the forensic requirement of differentiating endog...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkz014

    authors: Legg KM,Labay LM,Aiken SS,Logan BK

    更新日期:2019-08-23 00:00:00

  • Evaluation of internal standards for the analysis of amphetamine and methamphetamine.

    abstract::Deuterium-labeled analogues are available for a variety of drugs, but the amphetamines (amphetamine and methamphetamine) have more options available than any other drug. The analytical method and circumstances of its use can have a significant impact on the decision of what is the best internal standard to use. More t...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/19.6.375

    authors: Valtier S,Cody JT

    更新日期:1995-10-01 00:00:00

  • Bovine blood lead reference material.

    abstract::A protocol is described for the preparation and characterization of bovine blood lead (Pb) reference material (RM). Adult bovine animals are orally dosed with Pb as Pb(NO3)2, and blood is collected directly from the jugular vein into 5-mL evacuated, low-Pb glass tubes containing EDTA as anticoagulant. The blood is coo...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/13.4.204

    authors: Cox DH,Duncan CE,Wyatt GP,Meadow JS,Robinson JB

    更新日期:1989-07-01 00:00:00

  • A simple and sensitive quantitation of N,N-dimethyltryptamine by gas chromatography with surface ionization detection.

    abstract::A simple and sensitive method for determination of N,N-dimethyltryptamine (DMT) by gas chromatography (GC) with surface ionization detection (SID) is presented. Whole blood or urine, containing DMT and gramine (internal standard), was subjected to solid-phase extraction with a Sep-Pak C18 cartridge before analysis by ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/21.1.36

    authors: Ishii A,Seno H,Suzuki O,Hattori H,Kumazawa T

    更新日期:1997-01-01 00:00:00

  • GCD quantitation of opiates as propionyl derivatives in blood.

    abstract::We describe a method using a gas chromatograph with electron ionization detection (GCD) for the simultaneous determination of morphine, codeine, 6-monoacetylmorphine, ethylmorphine, and dihydrocodeine in blood. The method employs propionic anhydride in the presence of triethylamine to propionylate free hydroxyl groups...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/24.2.122

    authors: Mykkänen S,Seppälä J,Ariniemi K,Lillsunde P

    更新日期:2000-03-01 00:00:00

  • LC-QTOF-MS Identification of Major Urinary Cyclopropylfentanyl Metabolites Using Synthesized Standards.

    abstract::Cyclopropylfentanyl is a fentanyl analog implicated in 78 deaths in Europe and over 100 deaths in the United States, but toxicological information including metabolism data about this drug is scarce. The aim of this study was to provide the exact structure of abundant and unique metabolites of cyclopropylfentanyl alon...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkz057

    authors: Vikingsson S,Rautio T,Wallgren J,Åstrand A,Watanabe S,Dahlén J,Wohlfarth A,Konradsson P,Wu X,Kronstrand R,Gréen H

    更新日期:2019-09-10 00:00:00

  • Simultaneous determination of monoacetylmorphine, morphine, codeine, and other opiates by GC/MS.

    abstract::A GC/MS method for the simultaneous determination of morphine, codeine, and O-6-monoacetylmorphine as well as other semisynthetic opiates in urine is described. The method employs 2H6-acetic anhydride to acetylate free hydroxyl groups on all of the opiates. As a result, the same hydrolysis and extraction procedure is ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/13.6.326

    authors: Bowie LJ,Kirkpatrick PB

    更新日期:1989-11-01 00:00:00

  • ELISA Detection of Phenazepam, Etizolam, Pyrazolam, Flubromazepam, Diclazepam and Delorazepam in Blood Using Immunalysis® Benzodiazepine Kit.

    abstract::Phenazepam and etizolam were the first uncontrolled benzodiazepines available for sale in the UK. Pyrazolam, flubromazepam and diclazepam are not used medicinally anywhere in the world; they are produced exclusively for the uncontrolled, recreational market. It is important to know whether potentially abused drugs lik...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkv122

    authors: O'Connor LC,Torrance HJ,McKeown DA

    更新日期:2016-03-01 00:00:00

  • Duragesic transdermal patch: postmortem tissue distribution of fentanyl in 25 cases.

    abstract::Fentanyl is a potent, short-acting narcotic analgesic widely used as a surgical anesthetic and for the control of pain when administered in the form of a transdermal patch. The success of the patch can be attributed to fentanyl's low molecular weight and its highly lipophilic nature, which enables it to be readily abs...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/24.7.627

    authors: Anderson DT,Muto JJ

    更新日期:2000-10-01 00:00:00

  • Determination of buprenorphine and norbuprenorphine in urine and hair by gas chromatography-mass spectrometry.

    abstract::Buprenorphine, which is used in France as a substitution drug for opioid addiction, is widely abused, and several fatal cases have been reported. In order to confirm a recent intoxication or to establish retrospectively chronic abuse, a simple and reliable gas chromatographic-mass spectrometric method was developed an...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/23.4.270

    authors: Vincent F,Bessard J,Vacheron J,Mallaret M,Bessard G

    更新日期:1999-07-01 00:00:00

  • Screening, identification, and quantitation of benzodiazepines in postmortem samples by HPLC with photodiode array detection.

    abstract::A high-performance liquid chromatographic method has been developed for the simultaneous analysis of eight frequently used benzodiazepines and some of their metabolites in postmortem samples. The method includes a liquid-liquid extraction with n-hexane-ethyl acetate (70:30, v/v), gradient elution of a C8 reversed-phas...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/19.1.35

    authors: Lambert WE,Meyer E,Xue-Ping Y,De Leenheer AP

    更新日期:1995-01-01 00:00:00

  • Determination of tapentadol and its metabolite N-desmethyltapentadol in urine and oral fluid using liquid chromatography with tandem mass spectral detection.

    abstract::An analytical procedure for the determination of the new pain medication tapentadol and its main metabolite N-desmethyltapentadol (DMT), in urine and oral fluid has been developed and validated using liquid chromatography with tandem mass spectral detection (LC-MS-MS). Oral fluid was collected using Quantisal™ devices...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/34.8.458

    authors: Coulter C,Taruc M,Tuyay J,Moore C

    更新日期:2010-10-01 00:00:00

  • The identification of a chlorinated MDMA.

    abstract::The abuse of the designer amphetamines such as 3,4-methylenedioxymethamphetamine (MDMA) is increasing throughout the world. They have become popular drugs at all night techno dance parties, and their detection is an important issue. The objective of the presented study was to identify an unknown compound detected by t...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/29.5.353

    authors: Maresova V,Hampl J,Chundela Z,Zrcek F,Polasek M,Chadt J

    更新日期:2005-07-01 00:00:00

  • Ethanol analysis by headspace gas chromatography with simultaneous flame-ionization and mass spectrometry detection.

    abstract::Ethanol is the most frequently identified compound in forensic toxicology. Although confirmation involving mass spectrometry is desirable, relatively few methods have been published to date. A novel technique utilizing a Dean's Switch to simultaneously quantitate and confirm ethyl alcohol by flame-ionization (FID) and...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/anatox/35.7.501

    authors: Tiscione NB,Alford I,Yeatman DT,Shan X

    更新日期:2011-09-01 00:00:00

  • Two cases of fatal intoxication due to tranylcypromine overdose.

    abstract::Two cases of death following the ingestion of tranylcypromine are presented. High concentrations of tranylcypromine were determined in blood, urine, and liver by gas-liquid chromatography. Tranylcypromine was extracted from buffered blood with n-butyl chloride. The evaporated extract was derivatized with trifluoroacet...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/15.1.38

    authors: Boniface PJ

    更新日期:1991-01-01 00:00:00

  • Benzodiazepine analysis by negative chemical ionization gas chromatography/mass spectrometry.

    abstract::The application of gas chromatography/mass spectrometry (GC/MS) for the simultaneous quantitation of seven commonly encountered urinary benzodiazepine metabolites is described. After comparison of the signal-to-noise ratios of high mass ions of benzodiazepines using electron impact (EI), positive chemical ionization (...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/17.6.342

    authors: Fitzgerald RL,Rexin DA,Herold DA

    更新日期:1993-10-01 00:00:00

  • Acute Methiopropamine Intoxication After "Synthacaine" Consumption.

    abstract::Use of methiopropamine (MPA), a synthetic metamfetamine analog, has been detected since 2011 in Europe, but there is limited information on its acute toxicity. A 30-year-old man was admitted to the emergency department in a confused state, with paranoid delusion, auditory and visual hallucinatory experiences, and inco...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkw073

    authors: Daveluy A,Castaing N,Cherifi H,Richeval C,Humbert L,Faure I,Labadie M,Allorge D,Haramburu F,Molimard M,Titier K

    更新日期:2016-11-01 00:00:00

  • Field Detection of Drugs of Abuse in Oral Fluid Using the Alere™ DDS®2 Mobile Test System with Confirmation by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS).

    abstract::The collection and analysis of drugs in oral fluid (OF) at the roadside has become more feasible with the introduction of portable testing devices such as the Alere™ DDS®2 Mobile Test System (DDS®2). The objective of this study was to compare the on-site results for the DDS®2 to laboratory-based confirmatory assays wi...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkx105

    authors: Krotulski AJ,Mohr ALA,Friscia M,Logan BK

    更新日期:2018-04-01 00:00:00

  • Comparison of relative distribution of ketamine and norketamine in decomposed skeletal tissues following single and repeated exposures.

    abstract::Bone was analyzed for ketamine and norketamine to examine whether different patterns of drug exposure could be discriminated. Rats received (intraperitoneally) one 75 mg/kg dose (Acute-1 and Acute-2 groups), three 25-mg/kg doses 1 hour apart (Repeated group), or nine single daily ketamine doses of 75 mg/kg followed by...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bks045

    authors: Watterson JH,Donohue JP,Betit CC

    更新日期:2012-07-01 00:00:00

  • Analysis of psilocin, bufotenine and LSD in hair.

    abstract::A method for the simultaneous extraction of the hallucinogens psilocin, bufotenine, lysergic acid diethylamide (LSD) as well as iso-LSD, nor-LSD and O-H-LSD from hair with hydrochloride acid and methanol is presented. Clean-up of the hair extracts is performed with solid phase extraction using a mixed-mode cation exch...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bku141

    authors: Martin R,Schürenkamp J,Gasse A,Pfeiffer H,Köhler H

    更新日期:2015-03-01 00:00:00

  • Determination of opiates and cocaine and its metabolites in biological fluids by high-performance liquid chromatography with electrospray tandem mass spectrometry.

    abstract::A rapid, sensitive, and specific method for the determination of opiates and cocaine and metabolites in urine, plasma, and blood was established. A one-step extraction followed by liquid chromatography-electrospray ionization tandem mass spectrometry operating in multiple reaction monitoring mode was used. Two chromat...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/23.7.620

    authors: Cailleux A,Le Bouil A,Auger B,Bonsergent G,Turcant A,Allain P

    更新日期:1999-11-01 00:00:00