Abrogation of red blood cell G6PD enzyme activity through Heat treatment: development of survey material for the UK NEQAS G6PD scheme.

Abstract:

INTRODUCTION:Participation in external quality assessment (EQA) is central to the maintenance of high-quality laboratory results in patient diagnosis and clinical trials. Laboratories in the TAF112582 DETECTIVE study (ClinicalTrials.gov identifier: NCT01376167) are enrolled in the United Kingdom National Quality Assessment Scheme (UK NEQAS) for glucose-6-phosphate dehydrogenase (G6PD) quantitative assay, which utilizes ovine (sheep) blood as a readily available source of apparently G6PD-deficient survey material. A substitute for sheep blood was sought because some non-UK sites in the study encountered participation difficulties due to the strict regulations on the import of sheep blood into their countries. METHODS:G6PD activity in normal human donor blood was abrogated by the action of heat under controlled conditions. Residual G6PD activity in the heated samples was measured by UK NEQAS using the Trinity Biotech 345 kit (Trinity Biotech) and a Jenway 6715 UV/Vis spectrophotometer with external temperature control to monitor enzyme kinetics and linearity over a set time. Heat-treated material was also assayed for G6PD activity and assessed for its acceptability as EQA survey material by selected UK laboratories. RESULTS:Blood heated at 45 °C for 15 h showed a reduction in G6PD activity of 76.3 ± 4.6% (n = 6) and was considered acceptable as EQA material in terms of appearance and behaviour by the majority of UK sites in the trial. CONCLUSIONS:We have developed a simple heat-treatment procedure to produce EQA survey material with low/intermediate G6PD activity, similar to that found in females heterozygous for G6PD deficiency.

journal_name

Int J Lab Hematol

authors

Roper DR,De la Salle B,Soni V,Fletcher K,Green JA

doi

10.1111/ijlh.12627

subject

Has Abstract

pub_date

2017-06-01 00:00:00

pages

308-316

issue

3

eissn

1751-5521

issn

1751-553X

journal_volume

39

pub_type

临床试验,杂志文章,多中心研究
  • A hierarchical approach in the diagnostic workflow of chronic myelomonocytic leukemia: Pivotal role of the "Mono-dysplasia-score" combined with flow cytometric quantification of monocyte subsets.

    abstract:INTRODUCTION:Monocytosis is a frequent trigger for blood smear review in a routine hematology laboratory whereas chronic myelomonocytic leukemia (CMML) is infrequent and arises mostly in elderly patients. In order to define the best workflow for monocytosis, we studied three diagnostic approaches: the classical morphol...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13115

    authors: Zhu J,Sourdeau E,Aubert H,Clauser S,Maillon A,Capron C,Jondeau K,Ronez E,Schillinger F,Garnache-Ottou F,Cornet E,Bardet V

    更新日期:2019-12-01 00:00:00

  • ADAMTS13 activity to von Willebrand factor antigen ratio predicts acute kidney injury in patients with COVID-19: Evidence of SARS-CoV-2 induced secondary thrombotic microangiopathy.

    abstract:INTRODUCTION:Severe COVID-19 is often compounded by a prothrombotic state that is associated with poor outcomes. In this investigation, we aimed to evaluate ADAMTS13 activity, von Willebrand factor level (VWF:Ag), and the corresponding ADAMTS13 activity/VWF:Ag ratio, in patients with COVID-19 and for associations with ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13415

    authors: Henry BM,Benoit SW,de Oliveira MHS,Lippi G,Favaloro EJ,Benoit JL

    更新日期:2020-12-03 00:00:00

  • Diagnostic and prognostic utility of WBC counts and cell population data in patients with COVID-19.

    abstract:INTRODUCTION:Early diagnosis and identification of potential critical cases for timely treatment are crucial for COVID-19 patients. The aim of this study was to analyze the diagnostic and prognostic implications of WBC and cell population data (CPD) abnormalities related to COVID-19 at disease onset. METHODS:Baseline ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13395

    authors: Naoum FA,Ruiz ALZ,Martin FHO,Brito THG,Hassem V,Oliveira MGL

    更新日期:2020-11-15 00:00:00

  • Sickle cell-haemoglobin E (HbSE) compound heterozygosity: a clinical and haematological study.

    abstract::The paucity of clinical reports in the world literature suggests that, as a disease entity, haemoglobin SE compound heterozygosity is of negligible importance. In view of the significant community prevalence of this haemoglobinopathy in the Sultanate of Oman where it is the second most prevalent sickling disorder, a h...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1365-2257.2006.00886.x

    authors: Knox-Macaulay HH,Ahmed MM,Gravell D,Al-Kindi S,Ganesh A

    更新日期:2007-08-01 00:00:00

  • Establishment of reference interval for immature platelet fraction.

    abstract:INTRODUCTION:Immature platelet fraction (IPF) is a parameter for reticulated platelets. A high percentage IPF (%-IPF) is indicative of consumptive or recovering thrombocytopenic disorders in contrast to a low %-IPF seen in aplastic states. Absolute IPF (A-IPF) specifically reflects the number of immature platelets in c...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12049

    authors: Ko YJ,Kim H,Hur M,Choi SG,Moon HW,Yun YM,Hong SN

    更新日期:2013-10-01 00:00:00

  • Auer rod-like intracytoplasmic inclusions in multiple myeloma. A case report and review of the literature.

    abstract::Several intracytoplasmic morphological changes in the plasma cells of multiple myeloma have been described previously. However, Auer rod-like inclusions are rarely found in these types of cells. Here, we report a case of multiple myeloma with Auer rod-like, needle-shaped intracytoplasmic inclusions in plasma cells. A ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1751-553X.2007.01023.x

    authors: Hütter G,Nowak D,Blau IW,Thiel E

    更新日期:2009-04-01 00:00:00

  • The adsorption of dabigatran is as efficient as addition of idarucizumab to neutralize the drug in routine coagulation assays.

    abstract:INTRODUCTION:The direct thrombin inhibitor dabigatran interferes with thrombophilia screening and with the diagnosis of hemostasis disorders that develop during treatment with the anticoagulant. In vitro addition of idarucizumab, a humanized antibody fragment that binds dabigatran, to plasma samples containing dabigatr...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12807

    authors: Jacquemin M,Toelen J,Feyen L,Schoeters J,Van Horenbeeck I,Vanlinthout I,Debasse M,Vanassche T,Peerlinck K,Verhamme P

    更新日期:2018-08-01 00:00:00

  • Morphologic and cytogenetic variables affect the flow cytometric recovery of plasma cell myeloma cells in bone marrow aspirates.

    abstract:INTRODUCTION:It is widely recognized that plasma cells (PCs) are under-represented in flow cytometry (FC) studies, but the causes of this phenomenon are poorly understood. We sought to study potential variables that affect PC recovery by flow cytometry (FC) in the analysis of plasma cell myeloma (PCM). METHODS:We retr...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12411

    authors: Cogbill CH,Spears MD,Vantuinen P,Harrington AM,Olteanu H,Kroft SH

    更新日期:2015-12-01 00:00:00

  • Evaluation of the leukocyte differential on a new automated flow cytometry hematology analyzer.

    abstract:INTRODUCTION:The Hematoflow (Beckman Coulter, USA) is a new automated hematology analyzer, which provides a 16-part white blood cell count (WBC) differential. METHODS:We evaluated the differential WBC count performance of the Hematoflow. 101 blood samples from patients were selected for comparison analysis. RESULTS:T...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01432.x

    authors: Kim JE,Kim BR,Woo KS,Han JY

    更新日期:2012-10-01 00:00:00

  • The automation of routine light transmission platelet aggregation.

    abstract:INTRODUCTION:The investigation of platelet function by aggregometry requires specialist equipment and is labour intensive. We have developed an automated platelet aggregation method on a routine coagulation analyser. METHODS:We used a CS-2000i (Sysmex) with prototype software to perform aggregation in platelet-rich pl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12161

    authors: Lawrie AS,Kobayashi K,Lane PJ,Mackie IJ,Machin SJ

    更新日期:2014-08-01 00:00:00

  • Different kinetic patterns of BCR-ABL transcript levels in imatinib-treated chronic myeloid leukemia patients after achieving complete cytogenetic response.

    abstract::Bone marrow BCR-ABL transcript levels were monitored serially by real-time quantitative PCR in 46 imatinib-treated chronic myeloid leukemia patients after achieving complete cytogenetic response (CCyR) for a median of 42 months (range: 9-53). Of 41 patients in continuous CCyR, 32 and nine could achieve a >/=3-log (MMo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00962.x

    authors: Qin YZ,Liu YR,Zhu HH,Li JL,Ruan GR,Zhang Y,Jiang Q,Jiang H,Li LD,Chang Y,Huang XJ,Chen SS

    更新日期:2008-08-01 00:00:00

  • Molecular diagnosis of thrombocytopenia-absent radius syndrome using next-generation sequencing.

    abstract:INTRODUCTION:Thrombocytopenia-absent radius (TAR) syndrome is a rare autosomal recessive disease. Patients are compound heterozygotes for a loss-of-function allele, which in most cases is a large genomic deletion on chromosome 1q21.1 containing the RBM8A gene, and a noncoding variant located in the 5'UTR (rs139428292) ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12516

    authors: Nicchia E,Giordano P,Greco C,De Rocco D,Savoia A

    更新日期:2016-08-01 00:00:00

  • Evaluation of the HemoCue WBC DIFF in leukopenic patient samples.

    abstract:BACKGROUND:White blood cell (WBC) counts are used to monitor bone marrow function and to screen for infections. The HemoCue WBC DIFF Point-Of-Care (POC) instrument classifies WBCs through cell image recognition. To evaluate its suitability for monitoring cancer patients, we examined its performance in samples from pati...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13158

    authors: Kur DK,Agersnap N,Holländer NH,Pedersen OBV,Friis-Hansen L

    更新日期:2020-06-01 00:00:00

  • Clinical and hematological characteristics of 88 patients with COVID-19.

    abstract:INTRODUCTION:To retrospectively analyze epidemiological, clinical and hematological characteristics of COVID-19 patients. METHODS:The demographic, symptoms, and physiological parameters of 88 patients were collected and analyzed. The performance of complete blood count (CBC) indexes for monitoring and predicting the s...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13291

    authors: Zhang H,Cao X,Kong M,Mao X,Huang L,He P,Pan S,Li J,Lu Z

    更新日期:2020-12-01 00:00:00

  • The biological characteristics of dendritic cells derived in vitro from myelogeneous leukemia cells and healthy donor cells.

    abstract::Successful adoptive immunotherapy for leukemia depends on the generation of T cells that can specifically react with malignant cells. Dendritic cells (DCs) are important antigen-presenting cells in the development of antileukemia T-cell responses. Mononuclear cells (MNC) were isolated from peripheral blood or bone mar...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00986.x

    authors: Tong XM,Yao HP,Qian WB,Zhu LF,Fu ZH,Huang ZL,Jin J

    更新日期:2008-10-01 00:00:00

  • Clotting and chromogenic factor VIII assay variability in post-infusion and spiked samples containing full-length recombinant FVIII or recombinant factor VIII Fc fusion protein (rFVIIIFc).

    abstract:INTRODUCTION:Variability in FVIII measurement is a recognized problem. There are limited data for samples containing recombinant Factor VIII Fc fusion protein (rFVIIIFc). Many studies use samples for which factor concentrate has been spiked into FVIII deficient plasma in vitro. This approach requires validation. AIM/M...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12940

    authors: Kitchen S,Jennings I,Makris M,Kitchen DP,Woods TAL,Walker ID

    更新日期:2019-04-01 00:00:00

  • Multicentric evaluation of the new HemosIL Acustar® chemiluminescence ADAMTS13 activity assay.

    abstract:INTRODUCTION:Thrombotic thrombocytopenic purpura (TTP) is a rare life-threatening thrombotic microangiopathy (TMA) characterized by the severe deficiency of ADAMTS13 activity (<10%). Rapid ADAMTS13 testing is crucial for early diagnosis and optimal management of TTP patients and other TMAs. The objective of this study ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13414

    authors: Pascual C,Nieto JM,Fidalgo T,Seguí IG,Díaz-Ricart M,Docampo MF,Del Rio J,Salinas R

    更新日期:2020-12-02 00:00:00

  • Optimal wavelength for the clot waveform analysis: Determination of the best resolution with minimal interference of the reagents.

    abstract:INTRODUCTION:Clot waveform analysis (CWA), a new methodology to assess coagulation process, can be usefully applied in various clinical settings. However, its clinical use is limited mainly because of the absence of standardization. No consensus exists regarding the wavelengths at which CWA has to be performed what is ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12975

    authors: Evrard J,Siriez R,Morimont L,Thémans P,Laloy J,Bouvy C,Gheldof D,Mullier F,Dogné JM,Douxfils J

    更新日期:2019-06-01 00:00:00

  • A ten-color tube with dried antibody reagents for the screening of hematological malignancies.

    abstract:INTRODUCTION:The workflow in clinical flow cytometry laboratories must constantly be reviewed to develop technical procedures that improve quality and productivity and reduce costs. Using the Beckman Coulter dry coating technology, we customized a ten-color tube with dried antibody reagents, designated the Duraclone sc...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12753

    authors: Correia RP,Rajab A,Bento LC,Alexandre AM,Vaz AC,Schimidell D,Pedro EC,Perin FS,Nozawa ST,Barroso RS,Bacal NS

    更新日期:2018-04-01 00:00:00

  • DOAC plasma levels measured by chromogenic anti-Xa assays and HPLC-UV in apixaban- and rivaroxaban-treated patients from the START-Register.

    abstract:INTRODUCTION:To measure direct factor Xa inhibitor (apixaban, edoxaban, rivaroxaban) concentrations, dedicated chromogenic anti-Xa assays are recommended as suitable methods to provide rapid drug quantification. Moreover, the high-performance liquid chromatography with ultraviolet detection (HPLC-UV) is reported as a r...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13159

    authors: Cini M,Legnani C,Padrini R,Cosmi B,Dellanoce C,De Rosa G,Marcucci R,Pengo V,Poli D,Testa S,Palareti G

    更新日期:2020-04-01 00:00:00

  • A study of disseminated intravascular coagulation in acute leukemia reveals markedly elevated D-dimer levels are a sensitive indicator of acute promyelocytic leukemia.

    abstract:INTRODUCTION:While the presence of disseminated intravascular coagulation (DIC) has been implicated in worse clinical outcome in acute leukemia, the relationship between different subtypes of acute leukemia and the clinicopathologic features of DIC has not been systematically well studied. METHODS:In this study, we re...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12636

    authors: Shahmarvand N,Oak JS,Cascio MJ,Alcasid M,Goodman E,Medeiros BC,Arber DA,Zehnder JL,Ohgami RS

    更新日期:2017-08-01 00:00:00

  • A rare case of Lennert's type peripheral T-cell lymphoma with t(14;19)(q11.2;q13.3).

    abstract::Although most patients with peripheral T-cell lymphoma (PTCL) show clonal rearrangement of T-cell receptor genes, few PTCLs show recurrent chromosomal abnormalities. We describe here a rare chromosomal rearrangement, t(14;19)(q11.2;q13.3), in a Lennert's lymphoma, a variant of PTCL, not otherwise specified. Sequential...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01385.x

    authors: Shin SY,Jang S,Park CJ,Chi HS,Lee KH,Huh J,Seo EJ

    更新日期:2012-06-01 00:00:00

  • Performance evaluation of the Sysmex(®) XP-300 in an oncology setting: evaluation and comparison of hematological parameters with the Sysmex(®) XN-3000.

    abstract:INTRODUCTION:The Sysmex XP-300(®) (XP-300) is a new, fully automated hematology analyzer, designed to generate complete blood counts (CBC) with 3-part differential. In our study, the XP-300 was evaluated as a point-of-care (POC) analyzer in an oncology setting. In which blood samples from patients with different pathol...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/ijlh.12522

    authors: van Dievoet MA,Louagie H,Ghys T

    更新日期:2016-10-01 00:00:00

  • JAK2V617F mutation in patients with thrombosis: to screen or not to screen?

    abstract:INTRODUCTION:Thrombotic complications are a main concern in patients with myeloproliferative neoplasms. Recently, a gain-of-function mutation of the gene encoding the JAK2 tyrosine kinase that results in a valine-to-phenylalanine substitution at position 617 (V617F) has been described. Since the description of the JAK2...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1751-553X.2010.01275.x

    authors: Xavier SG,Gadelha T,Rezende SM,Zalcberg IR,Spector N

    更新日期:2011-04-01 00:00:00

  • International Council for Standardization in Haematology (ICSH) laboratory guidance for the evaluation of haemostasis analyser-reagent test systems. Part 1: Instrument-specific issues and commonly used coagulation screening tests.

    abstract::Before a new method is used for clinical testing, it is essential that it is evaluated for suitability for its intended purpose. This document gives guidance for the performance of verification, validation and implementation processes required by regulatory and accreditation bodies. It covers the planning and executio...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13411

    authors: Gardiner C,Coleman R,de Maat MPM,Dorgalaleh A,Echenagucia M,Gosselin RC,Ieko M,Kitchen S

    更新日期:2020-11-29 00:00:00

  • Transillumination: a new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing.

    abstract:INTRODUCTION:The collection of diagnostic blood specimens for routine haematological testing (RHT) is traditionally performed with tourniquet. However, the transillumination devices based on cold near-infrared LEDs have been formerly proposed as a valuable tool for identifying reliable venous accesses, especially in pa...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01305.x

    authors: Lima-Oliveira G,Lippi G,Salvagno GL,Montagnana M,Scartezini M,Guidi GC,Picheth G

    更新日期:2011-10-01 00:00:00

  • Hemostasis critical values among Iranian clinical laboratories "National Survey of 157 Clinical Laboratories".

    abstract:BACKGROUND:Immediate reporting of critical values or test results significantly outside the normal range has a growing role in the management of patients, especially in life-threatening conditions. Due to the lack of international consensus, diverse approaches are used for determination of thresholds, reporting, docume...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13109

    authors: Dorgalaleh A,Shiravand Y,Dabbagh A,Tabibian S,Hosseini MS,Mansouri Tourghabeh H,Rashidpanah J,Narouei F,Shams M,Gholami MS,Saneei Moghaddam E,Shahreki H

    更新日期:2019-12-01 00:00:00

  • Validation of reflex testing rules and establishment of a new workflow for body fluid cell analysis using a Sysmex XN-550 automatic hematology analyzer.

    abstract:INTRODUCTION:We developed and validated reflex testing rules for the microscopic examination (ME) of body fluids (BFs) on the Sysmex XN-550 (Sysmex Corporation) instrument. METHODS:We assessed the detection limits, precision, linearity, and carryover. To develop the reflex testing rules (derivation arm), we tested 515...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12774

    authors: Cho YU,You E,Jang S,Park CJ

    更新日期:2018-06-01 00:00:00

  • Clinical performance evaluation of the new hematology analyzer Mindray BC-6000.

    abstract:INTRODUCTION:With the progression of blood analysis technology, hematology analyzers become more complex and diverse. How to choose a superb instrument is a challenge for the laboratories. In the essay, we studied whether the newest BC-6000 hematology analyzer meets the needs of a clinical hematology laboratory. METHO...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13075

    authors: Shen Y,Cao J,Zhou Z,Wang Y,Shen Y,He J

    更新日期:2019-10-01 00:00:00

  • Guidance for storing blood samples in laboratories performing complete blood count with differential.

    abstract:INTRODUCTION:The complete blood count (CBC) with differential leukocyte count (DIFF) is an important part of clinical laboratory analyses and provides crucial data for clinicians. Delivery time after blood collection and conditions of storage is known to affect the reliability of results of some hematologic parameters....

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01452.x

    authors: Cornet E,Behier C,Troussard X

    更新日期:2012-12-01 00:00:00