Performance evaluation of the Sysmex(®) XP-300 in an oncology setting: evaluation and comparison of hematological parameters with the Sysmex(®) XN-3000.

Abstract:

INTRODUCTION:The Sysmex XP-300(®) (XP-300) is a new, fully automated hematology analyzer, designed to generate complete blood counts (CBC) with 3-part differential. In our study, the XP-300 was evaluated as a point-of-care (POC) analyzer in an oncology setting. In which blood samples from patients with different pathologies and treatments, affecting hematopoiesis, were analyzed. METHODS:Performance was evaluated according to the International Council for Standardization in Haematology (ICSH) guidelines and CLSI protocol H20-A2 . Beside precision, linearity and carry-over, a comparison study with the Sysmex(®) XN-3000 (XN-3000) and a manual reference leukocyte differential was performed. Flagging performance was also evaluated. RESULTS:XP-300 showed excellent precision and linearity results. For within- and between-run precision, the criteria, according to Ricos et al. , were met for all parameters tested, except for platelets in the low level. Less than or equal to 0.5% carry-over was seen for all parameters tested. Comparison studies showed an acceptable correlation with both XN-3000 and the manual reference leukocyte count. A suboptimal flagging performance was demonstrated. CONCLUSION:In the context of diagnosing cytopenia due to myelosuppressing agents or leukocytosis due to infection, the XP-300 showed good analytical performance. However, in the thrombocytopenic range, precision was suboptimal. In follow-up of hematological malignancies with the occurrence of abnormal cells, we advise verification with a more advanced analyzer or with microscopic review, although further studies with a higher prevalence of abnormal cells are needed.

journal_name

Int J Lab Hematol

authors

van Dievoet MA,Louagie H,Ghys T

doi

10.1111/ijlh.12522

subject

Has Abstract

pub_date

2016-10-01 00:00:00

pages

490-6

issue

5

eissn

1751-5521

issn

1751-553X

journal_volume

38

pub_type

杂志文章,随机对照试验
  • Expression of CD4 is correlated with an unfavorable prognosis in wild-type NPM1, FLT3-ITD-negative cytogenetically normal adult acute myeloid leukemia.

    abstract:INTRODUCTION:In the cytogenetically normal population of AML (CN-AML), FLT3-ITD-positive and wild-type NPM1 is correlated with a worse outcome, and FLT3-ITD-negative with NPM1-mut is correlated with a better outcome. This leaves a large subpopulation of CN-AML patients without NPM1 or FLT3-ITD mutations with heterogene...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12649

    authors: Guo RJ,Atenafu EG,Schimmer AD,Minden MD,Chang H

    更新日期:2017-08-01 00:00:00

  • Peripheral blood vs. bone marrow for molecular monitoring of BCR-ABL1 levels in chronic myelogenous leukemia, a retrospective analysis in allogeneic bone marrow recipients.

    abstract::Molecular monitoring of the BCR-ABL1 transcript in chronic myelogenous leukemia (CML) using quantitative real-time PCR (RQ-PCR) can be performed using either bone marrow (BM) or peripheral blood (PB). However, a recent report by Stock et al. [International Journal of Oncology 28 (2006) 1099] questioned the reliability...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2009.01198.x

    authors: Ballestrero A,Cirmena G,Dominietto A,Garuti A,Rocco I,Cea M,Moran E,Nencioni A,Miglino M,Raiola AM,Bacigalupo A,Patrone F

    更新日期:2010-08-01 00:00:00

  • Upregulation of long noncoding RNA Lnc-IRF2-3 and Lnc-ZNF667-AS1 is associated with poor survival in B-chronic lymphocytic leukemia.

    abstract:BACKGROUND:Lnc-IRF2-3 and Lnc-ZNF667-AS1 were recently studied as a positive biomarker for many tumor cells. However, experimental studies found that they are associated with worse outcomes in B-CLL. METHODS:A prospective case study was conducted on 135 B-CLL patients that were compared to thirty healthy controls. The...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13167

    authors: El-Khazragy N,Esmaiel MA,Mohamed MM,Hassan NS

    更新日期:2020-06-01 00:00:00

  • The applicability of multiparameter flow cytometry for the detection of minimal residual disease using different-from-normal panels to predict relapse in patients with acute myeloid leukemia after allogeneic transplantation.

    abstract:BACKGROUND:The MRD status detected using multiparameter flow cytometry (MFC) before allogeneic hematopoietic stem cell transplantation (allo-HSCT) has crucial prognostic value for patients with acute myeloid leukemia (AML) in morphologic complete remission (CR). We designed a novel panel of antibodies to identify aberr...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13070

    authors: Wang Z,Guo M,Zhang Y,Xu S,Cheng H,Wu J,Zhang W,Hu X,Yang J,Wang J,Tang G

    更新日期:2019-10-01 00:00:00

  • Evaluation of the HemoCue WBC DIFF in leukopenic patient samples.

    abstract:BACKGROUND:White blood cell (WBC) counts are used to monitor bone marrow function and to screen for infections. The HemoCue WBC DIFF Point-Of-Care (POC) instrument classifies WBCs through cell image recognition. To evaluate its suitability for monitoring cancer patients, we examined its performance in samples from pati...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13158

    authors: Kur DK,Agersnap N,Holländer NH,Pedersen OBV,Friis-Hansen L

    更新日期:2020-06-01 00:00:00

  • A rare case of Lennert's type peripheral T-cell lymphoma with t(14;19)(q11.2;q13.3).

    abstract::Although most patients with peripheral T-cell lymphoma (PTCL) show clonal rearrangement of T-cell receptor genes, few PTCLs show recurrent chromosomal abnormalities. We describe here a rare chromosomal rearrangement, t(14;19)(q11.2;q13.3), in a Lennert's lymphoma, a variant of PTCL, not otherwise specified. Sequential...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01385.x

    authors: Shin SY,Jang S,Park CJ,Chi HS,Lee KH,Huh J,Seo EJ

    更新日期:2012-06-01 00:00:00

  • Molecular diagnosis of thrombocytopenia-absent radius syndrome using next-generation sequencing.

    abstract:INTRODUCTION:Thrombocytopenia-absent radius (TAR) syndrome is a rare autosomal recessive disease. Patients are compound heterozygotes for a loss-of-function allele, which in most cases is a large genomic deletion on chromosome 1q21.1 containing the RBM8A gene, and a noncoding variant located in the 5'UTR (rs139428292) ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12516

    authors: Nicchia E,Giordano P,Greco C,De Rocco D,Savoia A

    更新日期:2016-08-01 00:00:00

  • Chronic active Epstein-Barr virus infection: A heterogeneous entity requiring a high index of suspicion for diagnosis.

    abstract::Chronic active Epstein-Barr virus infection of T- and NK-cell type, systemic form, is a rare entity within the spectrum of EBV-driven T- and NK-cell lymphoproliferative disorders. Established diagnostic criteria and a characteristic clinical course help to differentiate it from other closely related EBV-positive neopl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13199

    authors: Ondrejka SL,Hsi ED

    更新日期:2020-06-01 00:00:00

  • DOAC plasma levels measured by chromogenic anti-Xa assays and HPLC-UV in apixaban- and rivaroxaban-treated patients from the START-Register.

    abstract:INTRODUCTION:To measure direct factor Xa inhibitor (apixaban, edoxaban, rivaroxaban) concentrations, dedicated chromogenic anti-Xa assays are recommended as suitable methods to provide rapid drug quantification. Moreover, the high-performance liquid chromatography with ultraviolet detection (HPLC-UV) is reported as a r...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13159

    authors: Cini M,Legnani C,Padrini R,Cosmi B,Dellanoce C,De Rosa G,Marcucci R,Pengo V,Poli D,Testa S,Palareti G

    更新日期:2020-04-01 00:00:00

  • Entonox as a sedative for bone marrow aspiration and biopsy.

    abstract::Bone marrow aspiration and biopsy can be a painful procedure. Sedation techniques may make this investigation more acceptable to patients, but have the potential to cause life-threatening complications, as well as requiring additional staff and equipment for safe administration. We assessed the use of Entonox, a 50 : ...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1751-553X.2007.00905.x

    authors: Gudgin EJ,Besser MW,Craig JI

    更新日期:2008-02-01 00:00:00

  • Flow cytometry data analysis: Recent tools and algorithms.

    abstract::Flow cytometry (FCM) allows scientists to rapidly quantify up to 50 parameters for millions of cells per sample. The bottleneck in the application of the technology is data analysis, and the high number of parameters measured by the current generation of instruments requires the use of advanced computational algorithm...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13016

    authors: Montante S,Brinkman RR

    更新日期:2019-05-01 00:00:00

  • Guidance for storing blood samples in laboratories performing complete blood count with differential.

    abstract:INTRODUCTION:The complete blood count (CBC) with differential leukocyte count (DIFF) is an important part of clinical laboratory analyses and provides crucial data for clinicians. Delivery time after blood collection and conditions of storage is known to affect the reliability of results of some hematologic parameters....

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01452.x

    authors: Cornet E,Behier C,Troussard X

    更新日期:2012-12-01 00:00:00

  • Acquired haemophilia masked by warfarin therapy.

    abstract::Acquired haemophilia is a rare phenomenon and prompt diagnosis is essential for successful treatment. Early laboratory detection could minimize its potentially devastating consequences and reduce mortality but when a masking element such as anticoagulant therapy is present, delay in diagnosis is not uncommon. A prolon...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1365-2257.2006.00867.x

    authors: Vadikolia CM,Riddell A,Brooks S,Yee TT,Brown S,Lee C

    更新日期:2007-02-01 00:00:00

  • Standardization of haematology critical results management in adults: an International Council for Standardization in Haematology, ICSH, survey and recommendations.

    abstract:INTRODUCTION:These recommendations are intended to develop a consensus in the previously published papers as to which parameters and what values should be considered critical. A practical guide on the standardization of critical results management in haematology laboratories would be beneficial as part of good laborato...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12526

    authors: Keng TB,De La Salle B,Bourner G,Merino A,Han JY,Kawai Y,Peng MT,McCafferty R,International Council for Standardization in Haematology (ICSH).

    更新日期:2016-10-01 00:00:00

  • Clotting and chromogenic factor VIII assay variability in post-infusion and spiked samples containing full-length recombinant FVIII or recombinant factor VIII Fc fusion protein (rFVIIIFc).

    abstract:INTRODUCTION:Variability in FVIII measurement is a recognized problem. There are limited data for samples containing recombinant Factor VIII Fc fusion protein (rFVIIIFc). Many studies use samples for which factor concentrate has been spiked into FVIII deficient plasma in vitro. This approach requires validation. AIM/M...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12940

    authors: Kitchen S,Jennings I,Makris M,Kitchen DP,Woods TAL,Walker ID

    更新日期:2019-04-01 00:00:00

  • The mutual control of iron and erythropoiesis.

    abstract:BACKGROUND:Iron is essential for hemoglobin synthesis during terminal erythropoiesis. To supply adequate iron the carrier transferrin is required together with transferrin receptor endosomal cycle and normal mitochondrial iron utilization. Iron and iron protein deficiencies result in different types of anemia. Iron-def...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12505

    authors: Camaschella C,Pagani A,Nai A,Silvestri L

    更新日期:2016-05-01 00:00:00

  • Factor VII assay performance: an analysis of the North American Specialized Coagulation Laboratory Association proficiency testing results.

    abstract::The performance of factor VII (FVII) assays currently used by clinical laboratories was examined in North American Specialized Coagulation Laboratory Association (NASCOLA) proficiency tests. Data from 12 surveys conducted between 2008 and 2010, involving 20 unique specimens plus four repeat-tested specimens, were anal...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12083

    authors: Zantek ND,Hsu P,Refaai MA,Ledford-Kraemer M,Meijer P,Van Cott EM

    更新日期:2013-06-01 00:00:00

  • Signal transducer and activator of transcription 3 (STAT3) gene polymorphisms are associated with treatment outcomes in acute myeloid leukemia.

    abstract:INTRODUCTION:In the Janus kinase/signal transducer and activator of transcription (JAK/STAT) signaling pathway, STAT3 is one of the most prominent prognosis factors for cancer and leukemia. STAT3 activation might promote cellular transformation and therefore have an important role in human tumors. This study aimed to i...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01406.x

    authors: Zhong Y,Feng J,Chen B,Cheng L,Li Y,Qian J,Ding J,Gao F,Xia G

    更新日期:2012-08-01 00:00:00

  • Direct international normalized ratio determination using multicalibrators is more responsive than the conventional method for measuring prothrombin time.

    abstract::Direct international normalized ratio (INR) determination using certified INR plasmas was shown to improve precision and accuracy. We evaluated the utility of a multicalibrator in determining INR. INR values were measured in 493 blood samples from patients subjected to anticoagulation therapy (320) and control subject...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2009.01195.x

    authors: Cha CH,Park CJ,Kim DH,Kim MJ,Cho YU,Jang S,Chi HS

    更新日期:2010-08-01 00:00:00

  • ICSH recommendations for the measurement of haemoglobin F.

    abstract::Measurement of the Haemoglobin F in red cell haemolysates is important in the diagnosis of δβ thalassaemia, hereditary persistence of fetal haemoglobin (HPFH) and in the diagnosis and management of sickle cell disease. The distribution of Hb F in red cells is useful in the diagnosis of HPFH and in the assessment of fe...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,实务指引

    doi:10.1111/j.1751-553X.2011.01367.x

    authors: Stephens AD,Angastiniotis M,Baysal E,Chan V,Davis B,Fucharoen S,Giordano PC,Hoyer JD,Mosca A,Wild B,International Council for The Standardisation of Haematology (ICSH).

    更新日期:2012-02-01 00:00:00

  • Different kinetic patterns of BCR-ABL transcript levels in imatinib-treated chronic myeloid leukemia patients after achieving complete cytogenetic response.

    abstract::Bone marrow BCR-ABL transcript levels were monitored serially by real-time quantitative PCR in 46 imatinib-treated chronic myeloid leukemia patients after achieving complete cytogenetic response (CCyR) for a median of 42 months (range: 9-53). Of 41 patients in continuous CCyR, 32 and nine could achieve a >/=3-log (MMo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00962.x

    authors: Qin YZ,Liu YR,Zhu HH,Li JL,Ruan GR,Zhang Y,Jiang Q,Jiang H,Li LD,Chang Y,Huang XJ,Chen SS

    更新日期:2008-08-01 00:00:00

  • Red blood cell morphology.

    abstract::The foundation of laboratory hematologic diagnosis is the complete blood count and review of the peripheral smear. In patients with anemia, the peripheral smear permits interpretation of diagnostically significant red blood cell (RBC) findings. These include assessment of RBC shape, size, color, inclusions, and arrang...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12082

    authors: Ford J

    更新日期:2013-06-01 00:00:00

  • Limitation of the activated partial thromboplastin time as a monitoring method of the direct thrombin inhibitor argatroban.

    abstract:BACKGROUND:Argatroban is licensed for patients with heparin-induced thrombocytopenia and monitoring is conventionally by activated partial thromboplastin time (APTT) ratio with a target of 1.5-3.0 and not exceeding 100 s. The APTT may be influenced by coagulopathies, lupus anticoagulant and raised FVIII levels. Variabl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12414

    authors: Guy S,Kitchen S,Maclean R,Van Veen JJ

    更新日期:2015-12-01 00:00:00

  • Sickle cell-haemoglobin E (HbSE) compound heterozygosity: a clinical and haematological study.

    abstract::The paucity of clinical reports in the world literature suggests that, as a disease entity, haemoglobin SE compound heterozygosity is of negligible importance. In view of the significant community prevalence of this haemoglobinopathy in the Sultanate of Oman where it is the second most prevalent sickling disorder, a h...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1365-2257.2006.00886.x

    authors: Knox-Macaulay HH,Ahmed MM,Gravell D,Al-Kindi S,Ganesh A

    更新日期:2007-08-01 00:00:00

  • Toward routine detection of extracellular vesicles in clinical samples.

    abstract::The majority, if not all, of human cell types secrete extracellular vesicles (EVs) into their environment, at least partly as a means of intercellular communication. These secreted vesicles can be detected in most bodily fluids including blood, urine, and saliva. The number of secreted vesicles and their composition i...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12247

    authors: van der Meel R,Krawczyk-Durka M,van Solinge WW,Schiffelers RM

    更新日期:2014-06-01 00:00:00

  • Use of a capillary specimen in the laboratory to verify a point-of-care international normalized ratio: Avoidance of a venipuncture in a pediatric setting.

    abstract:INTRODUCTION:Point-of-care (POC) international normalized ratio (INR) values above an institutional cutoff are confirmed in the laboratory using a gold standard venous specimen. This can be problematic in a pediatric setting. METHOD:In this study, 449 consecutive POC INR results were compared to an INR performed in th...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12920

    authors: Williams VK

    更新日期:2019-02-01 00:00:00

  • Evaluation of the leukocyte differential on a new automated flow cytometry hematology analyzer.

    abstract:INTRODUCTION:The Hematoflow (Beckman Coulter, USA) is a new automated hematology analyzer, which provides a 16-part white blood cell count (WBC) differential. METHODS:We evaluated the differential WBC count performance of the Hematoflow. 101 blood samples from patients were selected for comparison analysis. RESULTS:T...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01432.x

    authors: Kim JE,Kim BR,Woo KS,Han JY

    更新日期:2012-10-01 00:00:00

  • Red cell membrane disorders.

    abstract::Significant advances have been made in our understanding of the structural basis for altered cell function in various inherited red cell membrane disorders with reduced red cell survival and resulting hemolytic anemia. The current review summarizes these advances as they relate to defining the molecular and structural...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12657

    authors: Narla J,Mohandas N

    更新日期:2017-05-01 00:00:00

  • Gene expression risk signatures maintain prognostic power in multiple myeloma despite microarray probe set translation.

    abstract:INTRODUCTION:Gene expression profiling (GEP) risk models in multiple myeloma are based on 3'-end microarrays. We hypothesized that GEP risk signatures could retain prognostic power despite being translated and applied to whole-transcript microarray data. METHODS:We studied CD138-positive bone marrow plasma cells in a ...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/ijlh.12486

    authors: Hermansen NE,Borup R,Andersen MK,Vangsted AJ,Clausen NT,Kristensen DL,Nielsen FC,Gimsing P

    更新日期:2016-06-01 00:00:00

  • A level-headed approach to measuring direct oral anticoagulants: A 2-year retrospective analysis of DOAC levels from a tertiary UK centre.

    abstract:INTRODUCTION:Direct oral anticoagulants (DOAC) are commonly prescribed and measuring drug levels may be useful in a number of contexts. However, data on DOAC level measurement and their clinical utility in real-world studies are limited. METHODS:We carried out a 2-year retrospective cohort study of DOAC levels measure...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12944

    authors: Denny NDR,Keighley L,Siganporia Z,Thachil J,Nash MJ

    更新日期:2019-04-01 00:00:00