Abstract:
:Tissue-equivalent proportional counters (TEPCs) are widely used in experimental microdosimetry for characterising the radiation quality in radiation protection and radiation therapy environments. Generally, TEPCs are filled with tissue-equivalent gas mixtures, at low gas pressure, to simulate tissue site sizes similar to the cell nucleus (1 or 2 µm). The TEPC response using Monte Carlo (MC) codes can be applied to supplement experimental measurements. Most of general-purpose MC codes currently available recourse to the condensed-history approach to model the electron transport and do not transport low-energy electrons (<1 keV), which can lead to systematic errors, especially in thin layers and in gas-condensed medium interfaces. In this work, a comparison between experimental microdosimetric spectra of (60)Co and (137)Cs radiation at different simulated sizes (from 1.0 to 3.0 μm) in pure propane versus simulated spectra obtained with two general-purpose codes FLUKA and PENELOPE, which include a detailed simulation of electron-photon transport in arbitrary materials, including gases, is presented.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Chiriotti S,Moro D,Conte V,Colautti P,D'Agostino E,Sterpin E,Vynckier Sdoi
10.1093/rpd/nct248subject
Has Abstractpub_date
2014-10-01 00:00:00pages
454-8issue
1-4eissn
0144-8420issn
1742-3406pii
nct248journal_volume
161pub_type
杂志文章abstract::Prudence is a cornerstone of radiation protection philosophy. However, whilst the concept is clearly valid at the level of principle, it is nonetheless necessary to ask 'How should prudence be applied in the context of various practical situations.' This is perhaps particularly important where exposures are low-within...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw310
更新日期:2017-04-01 00:00:00
abstract::A passively safe small reactor for a distributed energy system, PSRD, is an integral type of light-water reactor with a thermal output of 100 or 300 MW aimed to be used for supplying district heat, electricity to small grids, and so on. Candidate locations for the PSRD as a distributed energy source are on-ground, dee...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci208
更新日期:2005-01-01 00:00:00
abstract::The reconstruction of radiation doses to Mayak Production Association workers in central Russia supports radiation epidemiological studies for the U.S.-Russian Joint Coordinating Committee on Radiation Effects Research. The most recent version of the dosimetry was performed with the Mayak Worker Dosimetry System-2013....
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx020
更新日期:2017-11-01 00:00:00
abstract::Results of performance tests verifying the dosimetric properties of dosimetric systems are published in various reports (e.g. IAEA and EURADOS). However, there is hardly any information in the open literature relating to the uncertainty in a dose measurement or in the annual dose, which is increased by failure of the ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch287
更新日期:2004-01-01 00:00:00
abstract::For the calibration of personal dosemeters in terms of H(p)(10), the ISO water slab phantom shall be used. The irradiation geometry must be chosen such that the field diameter at the phantom front surface is large enough to irradiate the phantom completely and, in addition, homogeneously. However, in practice it is no...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq036
更新日期:2010-06-01 00:00:00
abstract::The indoor workplace environment was evaluated for exposure to radon and its decay products at two Universities in two metropolises of Japan. The mean radon concentrations in Nagoya University (NU) and Hokkaido University (HU) were 16.7 Bq m(-3) and 18.0 Bq m(-3), respectively. Activity median aerodynamic diameter (AM...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,多中心研究
doi:10.1093/rpd/ncm221
更新日期:2007-01-01 00:00:00
abstract::One of the topics which forms part of CONRAD project addresses the problems related to the dosimetry of complex-mixed radiation fields at workplaces. This topic was included in work package (WP) 6. WP 6 was established to co-ordinate research activities in two areas:the development of new techniques and the improvemen...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn220
更新日期:2008-01-01 00:00:00
abstract::This study identified occupational factors associated with radiation exposure in Korea. Survey data of 16 037 workers from 2016 to 2017, including lifestyle factors and occupational characteristics, were combined with the National Dose Registry. Higher average annual doses were observed in groups exhibiting health ris...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa019
更新日期:2020-07-07 00:00:00
abstract::This study aimed to estimate the radiation organ doses from occupational exposure in 94 396 Korean medical radiation workers. Data on badge doses (i.e. personal dose equivalent at 10 mm) between 1996 and 2011 obtained from a national dosimetry registry, survey data from 2012 to 2013, and organ dose conversion coeffici...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx239
更新日期:2018-04-01 00:00:00
abstract::Image viewing and processing software in computed radiography manipulates image contrast in such a way that all relevant image features are rendered to an appropriate degree of visibility, and improves image quality using enhancement algorithms. The purpose of this study was to investigate procedures for the quality a...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci742
更新日期:2005-01-01 00:00:00
abstract::The World Health Organization (WHO), the International Commission on Non-Ionizing Radiation Protection (ICNIRP), WHO's scientific collaborating centres (including the UK's National Radiological Protection Board (NRPB)) and over 50 participating Member States are participants of WHO's International EMF Project. As part...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006363
更新日期:2003-01-01 00:00:00
abstract::Between 1952 and 1957, the UK exploded a total of 12 nuclear devices in Australia, and also conducted about 600 'minor trials' that did not involve a nuclear explosion. Over 16 000 Australian servicemen and civilians were involved in the UK tests in Australia. This paper reports the estimation of doses that the Austra...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp164
更新日期:2009-09-01 00:00:00
abstract::The novel DIS-1 dosemeter developed by RADOS is based on ionisation chambers with so-called Direct Ion Storage (DIS). The dosemeter can measure Hp(10) and Hp(0.07) of photon and Hp(0.07) of beta irradiation. The characteristics of the commercially available DIS-1 dosemeter were studied at the Paul Scherrer Institute, ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005984
更新日期:2002-01-01 00:00:00
abstract::This article report the measurements on-board a small aircraft at the same altitude and around the same geographic coordinates. The measurements of Ambient Dose Equivalent Rate (H*(10)) were performed in several positions inside the aircraft, close and far from the pilot location and the discrimination between neutron...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw384
更新日期:2017-11-01 00:00:00
abstract::Detailed data relating to patient dose have been acquired for 18, randomly chosen, patients undergoing coronary angiographies. During the procedure, dose-area product (DAP), kV and beam collimation were recorded for each projection. Total DAP, fluoroscopy time and number of cine frames were also noted. Patient effecti...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006466
更新日期:2001-01-01 00:00:00
abstract::A Bayesian unfolding has been applied to ionisation distributions due to 5.4 MeV alpha particles in a 20-nm site obtained using Monte Carlo simulations, taking into account different detection efficiency conditions. The ideal case of a target volume with uniform efficiency has been investigated to study the dependence...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch143
更新日期:2004-01-01 00:00:00
abstract::Evaluation of LiF:Mg,Ti thermoluminescence dosemeters (TLDs) according to the high-temperature ratio (HTR) method enables the determination of the dose-average linear energy transfer (LET), the mean quality factor and the dose equivalent in mixed radiation fields of unknown composition. The neutron contribution is ass...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch209
更新日期:2004-01-01 00:00:00
abstract::The USA must be prepared to provide a prompt, coordinated and integrated response for radiation dose and injury assessment for suspected radiation exposure, whether it involves isolated cases or mass casualties. Dose estimation for radiation accidents typically necessitates a multiple parameter diagnostics approach th...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy294
更新日期:2019-12-31 00:00:00
abstract::Radionuclide concentrations of ²²⁶Ra, ²³²Th and ⁴⁰K in different types of building materials used in Egypt were measured using gamma-ray spectroscopy. The results showed relatively moderate radionuclide concentrations for all samples except granite, which showed extremely high concentrations of 78.75 ± 2.36, 2.82 ± 0....
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct129
更新日期:2013-12-01 00:00:00
abstract::The activity size distribution of the Equilibrium-Equivalent Concentration (EER) of 222Rn is one of the most important parameters for the estimation of radiation dose by inhalation of radon decay products. A series of measurements of the EER activity size distribution were performed by the screen diffusion battery in ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx157
更新日期:2017-11-01 00:00:00
abstract::Radioiodine therapy is often the method of choice for treatment of hyperthyroidism because it is considered safe, is relatively inexpensive, and is convenient for the patient and except for occasional hypothyroidism, almost without side effects. Even though radioiodine treatment has been performed for over 50 years, t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch013
更新日期:2004-01-01 00:00:00
abstract::In the framework of collaboration among the ENEA Radiation Protection Institute (Bologna), the ENEA Fusion Department (Frascati) and the INFN-LNF-Radiation Protection Group (Frascati), an experimental campaign was organised on the usage of thermoluminescence dosemeters (TLDs) for the dosimetric and spectrometric chara...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci577
更新日期:2006-01-01 00:00:00
abstract::In 2008, the German Childhood Cancer Registry published the results of the Kinderkrebs in der Umgebung von Kernkraftwerken (KiKK) study of childhood cancer and leukaemia around German nuclear power stations. The positive findings appeared to conflict with the results of a recent British analysis carried out by the Com...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncn254
更新日期:2008-01-01 00:00:00
abstract::In response to questions raised after the Gulf War about the health significance of exposure to depleted uranium (DU), the US Department of Defense initiated a study designed to provide an improved scientific basis for assessment of possible health effects on soldiers in vehicles struck by these munitions. As part of ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006215
更新日期:2003-01-01 00:00:00
abstract::Spinal deformities affect young individuals predominantly girls who are usually subjected to regular and intensive radiological investigation especially before and after corrective surgery. Optimisation of spine computed tomography (CT) and the implementation of the low-dose CT in the work-up of spinal deformities wer...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp306
更新日期:2010-04-01 00:00:00
abstract::The most used passive detectors for Radon measurement are the CR39s, both for the good stability of the material and for the practicality of use. But, commercial reading systems are expensive and not always fast. The aim of the present work was the development of a method for a rapid, efficient and economic evaluation...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa140
更新日期:2020-11-27 00:00:00
abstract::Entrance surface doses (ESDs) were measured for the most common types of X ray procedures, such as chest PA, lumber spine AP, lumber spine lateral, skull AP, skull lateral and pelvis AP in four major hospitals of Dhaka, the capital city of Bangladesh. Organ/tissue doses for 29 organs/tissues and effective doses for th...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006549
更新日期:2001-01-01 00:00:00
abstract::The National Institute of Standards and Technology developed a new set of test sources for testing of portal monitors against the ANSI standard N42.35-2004. The design and source specifications are provided in this work. ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch422
更新日期:2005-01-01 00:00:00
abstract::The existence of non-targeted effects (NTEs) of radiation (genomic instability and bystander effects) has been generally accepted for >20 y; however, there is research, which was largely ignored going back to 1915 reporting these effects. Despite today's general acceptance of the phenomenon of NTE, there is little agr...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncv155
更新日期:2015-09-01 00:00:00
abstract::Thoron progeny concentrations were determined using the time-integrated method around closed uranium mine sites in Japan. Because the time-integrated radon progeny monitor developed by the authors has the function to detect (212)Po, time-integrated monitoring of thoron progeny concentration is also available with the ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq242
更新日期:2010-10-01 00:00:00