Monte Carlo tools to supplement experimental microdosimetric spectra.

Abstract:

:Tissue-equivalent proportional counters (TEPCs) are widely used in experimental microdosimetry for characterising the radiation quality in radiation protection and radiation therapy environments. Generally, TEPCs are filled with tissue-equivalent gas mixtures, at low gas pressure, to simulate tissue site sizes similar to the cell nucleus (1 or 2 µm). The TEPC response using Monte Carlo (MC) codes can be applied to supplement experimental measurements. Most of general-purpose MC codes currently available recourse to the condensed-history approach to model the electron transport and do not transport low-energy electrons (<1 keV), which can lead to systematic errors, especially in thin layers and in gas-condensed medium interfaces. In this work, a comparison between experimental microdosimetric spectra of (60)Co and (137)Cs radiation at different simulated sizes (from 1.0 to 3.0 μm) in pure propane versus simulated spectra obtained with two general-purpose codes FLUKA and PENELOPE, which include a detailed simulation of electron-photon transport in arbitrary materials, including gases, is presented.

journal_name

Radiat Prot Dosimetry

authors

Chiriotti S,Moro D,Conte V,Colautti P,D'Agostino E,Sterpin E,Vynckier S

doi

10.1093/rpd/nct248

subject

Has Abstract

pub_date

2014-10-01 00:00:00

pages

454-8

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

nct248

journal_volume

161

pub_type

杂志文章
  • PRUDENCE AND CONSERVATISM IN RADIATION PROTECTION: A CASE STUDY.

    abstract::Prudence is a cornerstone of radiation protection philosophy. However, whilst the concept is clearly valid at the level of principle, it is nonetheless necessary to ask 'How should prudence be applied in the context of various practical situations.' This is perhaps particularly important where exposures are low-within...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw310

    authors: Coates R

    更新日期:2017-04-01 00:00:00

  • Radiation safety assessment of a system of small reactors for distributed energy.

    abstract::A passively safe small reactor for a distributed energy system, PSRD, is an integral type of light-water reactor with a thermal output of 100 or 300 MW aimed to be used for supplying district heat, electricity to small grids, and so on. Candidate locations for the PSRD as a distributed energy source are on-ground, dee...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci208

    authors: Odano N,Ishida T

    更新日期:2005-01-01 00:00:00

  • THE MAYAK WORKER DOSIMETRY SYSTEM (MWDS-2013): AN INTRODUCTION TO THE DOCUMENTATION.

    abstract::The reconstruction of radiation doses to Mayak Production Association workers in central Russia supports radiation epidemiological studies for the U.S.-Russian Joint Coordinating Committee on Radiation Effects Research. The most recent version of the dosimetry was performed with the Mayak Worker Dosimetry System-2013....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx020

    authors: Napier BA

    更新日期:2017-11-01 00:00:00

  • Quality control and reliability of reported doses.

    abstract::Results of performance tests verifying the dosimetric properties of dosimetric systems are published in various reports (e.g. IAEA and EURADOS). However, there is hardly any information in the open literature relating to the uncertainty in a dose measurement or in the annual dose, which is increased by failure of the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch287

    authors: Stadtmann H,Figel M,Kamenopoulou V,Kluszczynski D,Roed H,Van Dijk J

    更新日期:2004-01-01 00:00:00

  • Influence of the uniformity of the slab phantom illumination on the calibration of personal dosemeters.

    abstract::For the calibration of personal dosemeters in terms of H(p)(10), the ISO water slab phantom shall be used. The irradiation geometry must be chosen such that the field diameter at the phantom front surface is large enough to irradiate the phantom completely and, in addition, homogeneously. However, in practice it is no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq036

    authors: Ankerhold U,Ambrosi P

    更新日期:2010-06-01 00:00:00

  • The study of activity median aerodynamic diameter using imaging plate technique for assessment of effective dose from radon and its decay products.

    abstract::The indoor workplace environment was evaluated for exposure to radon and its decay products at two Universities in two metropolises of Japan. The mean radon concentrations in Nagoya University (NU) and Hokkaido University (HU) were 16.7 Bq m(-3) and 18.0 Bq m(-3), respectively. Activity median aerodynamic diameter (AM...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncm221

    authors: Rahman NM,Iida T,Yamazawa H,Yokoyama S,Moriizumi J,Saito F,Ito T

    更新日期:2007-01-01 00:00:00

  • Further progress in the characterisation of complex radiation fields.

    abstract::One of the topics which forms part of CONRAD project addresses the problems related to the dosimetry of complex-mixed radiation fields at workplaces. This topic was included in work package (WP) 6. WP 6 was established to co-ordinate research activities in two areas:the development of new techniques and the improvemen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn220

    authors: Spurny F,Silari M

    更新日期:2008-01-01 00:00:00

  • OCCUPATIONAL EXPOSURE CHARACTERISTICS AND FACTORS ASSOCIATED WITH RADIATION DOSES AMONG KOREAN RADIATION WORKERS.

    abstract::This study identified occupational factors associated with radiation exposure in Korea. Survey data of 16 037 workers from 2016 to 2017, including lifestyle factors and occupational characteristics, were combined with the National Dose Registry. Higher average annual doses were observed in groups exhibiting health ris...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa019

    authors: Kim J,Seo S,Lee DN,Park S,Im KJ,Park S,Jin YW

    更新日期:2020-07-07 00:00:00

  • ESTIMATION OF ORGAN DOSES AMONG DIAGNOSTIC MEDICAL RADIATION WORKERS IN SOUTH KOREA.

    abstract::This study aimed to estimate the radiation organ doses from occupational exposure in 94 396 Korean medical radiation workers. Data on badge doses (i.e. personal dose equivalent at 10 mm) between 1996 and 2011 obtained from a national dosimetry registry, survey data from 2012 to 2013, and organ dose conversion coeffici...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx239

    authors: Choi Y,Shil Cha E,Jin Bang Y,Ko S,Ha M,Lee C,Jin Lee W

    更新日期:2018-04-01 00:00:00

  • Quality assurance (QA) procedures for software: evaluation of an ADC quality system.

    abstract::Image viewing and processing software in computed radiography manipulates image contrast in such a way that all relevant image features are rendered to an appropriate degree of visibility, and improves image quality using enhancement algorithms. The purpose of this study was to investigate procedures for the quality a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci742

    authors: Efstathopoulos EP,Benekos O,Molfetas M,Charou E,Kottou S,Argentos S,Kelekis NL

    更新日期:2005-01-01 00:00:00

  • WHO's health risk assessment of ELF fields.

    abstract::The World Health Organization (WHO), the International Commission on Non-Ionizing Radiation Protection (ICNIRP), WHO's scientific collaborating centres (including the UK's National Radiological Protection Board (NRPB)) and over 50 participating Member States are participants of WHO's International EMF Project. As part...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006363

    authors: Repacholi MH

    更新日期:2003-01-01 00:00:00

  • Assessment of radiation doses to Australian participants in British nuclear tests.

    abstract::Between 1952 and 1957, the UK exploded a total of 12 nuclear devices in Australia, and also conducted about 600 'minor trials' that did not involve a nuclear explosion. Over 16 000 Australian servicemen and civilians were involved in the UK tests in Australia. This paper reports the estimation of doses that the Austra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp164

    authors: Crouch P,Robotham FR,Williams G,Wise K

    更新日期:2009-09-01 00:00:00

  • A legally approved personal dosemeter for photon and beta radiation based on direct ion storage.

    abstract::The novel DIS-1 dosemeter developed by RADOS is based on ionisation chambers with so-called Direct Ion Storage (DIS). The dosemeter can measure Hp(10) and Hp(0.07) of photon and Hp(0.07) of beta irradiation. The characteristics of the commercially available DIS-1 dosemeter were studied at the Paul Scherrer Institute, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005984

    authors: Boschung M,Fiechtner A,Wernli C

    更新日期:2002-01-01 00:00:00

  • INVESTIGATION OF THE INFLUENCE OF THE POSITION INSIDE A SMALL AIRCRAFT ON THE COSMIC-RADIATION-INDUCED DOSE.

    abstract::This article report the measurements on-board a small aircraft at the same altitude and around the same geographic coordinates. The measurements of Ambient Dose Equivalent Rate (H*(10)) were performed in several positions inside the aircraft, close and far from the pilot location and the discrimination between neutron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw384

    authors: Prado ACM,Pazianotto MT,Gonçalez OL,Dos Santos LR,Caldeira AD,Pereira HHC,Hubert G,Federico CA

    更新日期:2017-11-01 00:00:00

  • Effective dose to a patient undergoing coronary angiography.

    abstract::Detailed data relating to patient dose have been acquired for 18, randomly chosen, patients undergoing coronary angiographies. During the procedure, dose-area product (DAP), kV and beam collimation were recorded for each projection. Total DAP, fluoroscopy time and number of cine frames were also noted. Patient effecti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006466

    authors: Lobotessi H,Karoussou A,Neofotistou V,Louisi A,Tsapaki V

    更新日期:2001-01-01 00:00:00

  • Reconstruction of cluster distributions at 100% detection efficiency for a track-nanodosimetric counter through a Bayesian analysis.

    abstract::A Bayesian unfolding has been applied to ionisation distributions due to 5.4 MeV alpha particles in a 20-nm site obtained using Monte Carlo simulations, taking into account different detection efficiency conditions. The ideal case of a target volume with uniform efficiency has been investigated to study the dependence...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch143

    authors: De Nardo L,Lesimple M,Canella S,Grosswendt B

    更新日期:2004-01-01 00:00:00

  • A TLD-based personal dosemeter system for aircrew monitoring.

    abstract::Evaluation of LiF:Mg,Ti thermoluminescence dosemeters (TLDs) according to the high-temperature ratio (HTR) method enables the determination of the dose-average linear energy transfer (LET), the mean quality factor and the dose equivalent in mixed radiation fields of unknown composition. The neutron contribution is ass...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch209

    authors: Hajek M,Berger T,Vana N

    更新日期:2004-01-01 00:00:00

  • CONCEPTS OF OPERATIONS FOR A US DOSIMETRY AND BIODOSIMETRY NETWORK.

    abstract::The USA must be prepared to provide a prompt, coordinated and integrated response for radiation dose and injury assessment for suspected radiation exposure, whether it involves isolated cases or mass casualties. Dose estimation for radiation accidents typically necessitates a multiple parameter diagnostics approach th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy294

    authors: Dainiak N,Albanese J,Kaushik M,Balajee AS,Romanyukha A,Sharp TJ,Blakely WF

    更新日期:2019-12-31 00:00:00

  • Evaluation of radionuclide concentrations and associated radiological hazard indexes in building materials used in Egypt.

    abstract::Radionuclide concentrations of ²²⁶Ra, ²³²Th and ⁴⁰K in different types of building materials used in Egypt were measured using gamma-ray spectroscopy. The results showed relatively moderate radionuclide concentrations for all samples except granite, which showed extremely high concentrations of 78.75 ± 2.36, 2.82 ± 0....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct129

    authors: Hassan NM,Mansour NA,Fayez-Hassan M

    更新日期:2013-12-01 00:00:00

  • Simultaneous Measurements of Nanoaerosols and Radioactive Aerosols Containing the Short-lived Radon Isotopes.

    abstract::The activity size distribution of the Equilibrium-Equivalent Concentration (EER) of 222Rn is one of the most important parameters for the estimation of radiation dose by inhalation of radon decay products. A series of measurements of the EER activity size distribution were performed by the screen diffusion battery in ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx157

    authors: Otahal PPS,Burian I,Ondracek J,Zdimal V,Holub RF

    更新日期:2017-11-01 00:00:00

  • Excess radiation absorbed doses from non-optimised radioiodine treatment of hyperthyroidism.

    abstract::Radioiodine therapy is often the method of choice for treatment of hyperthyroidism because it is considered safe, is relatively inexpensive, and is convenient for the patient and except for occasional hypothyroidism, almost without side effects. Even though radioiodine treatment has been performed for over 50 years, t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch013

    authors: Jönsson H,Mattsson S

    更新日期:2004-01-01 00:00:00

  • Inter-comparison among different TLD-based techniques in a standard multisphere assembly for the characterisation of neutron fields.

    abstract::In the framework of collaboration among the ENEA Radiation Protection Institute (Bologna), the ENEA Fusion Department (Frascati) and the INFN-LNF-Radiation Protection Group (Frascati), an experimental campaign was organised on the usage of thermoluminescence dosemeters (TLDs) for the dosimetric and spectrometric chara...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci577

    authors: Bedogni R,Angelone M,Esposito A,Chiti M

    更新日期:2006-01-01 00:00:00

  • Childhood leukaemia near British nuclear installations: methodological issues and recent results.

    abstract::In 2008, the German Childhood Cancer Registry published the results of the Kinderkrebs in der Umgebung von Kernkraftwerken (KiKK) study of childhood cancer and leukaemia around German nuclear power stations. The positive findings appeared to conflict with the results of a recent British analysis carried out by the Com...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncn254

    authors: Bithell JF,Keegan TJ,Kroll ME,Murphy MF,Vincent TJ

    更新日期:2008-01-01 00:00:00

  • Measuring aerosols generated inside armoured vehicles perforated by depleted uranium ammunition.

    abstract::In response to questions raised after the Gulf War about the health significance of exposure to depleted uranium (DU), the US Department of Defense initiated a study designed to provide an improved scientific basis for assessment of possible health effects on soldiers in vehicles struck by these munitions. As part of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006215

    authors: Parkhurst MA

    更新日期:2003-01-01 00:00:00

  • Low-dose spine CT: optimisation and clinical implementation.

    abstract::Spinal deformities affect young individuals predominantly girls who are usually subjected to regular and intensive radiological investigation especially before and after corrective surgery. Optimisation of spine computed tomography (CT) and the implementation of the low-dose CT in the work-up of spinal deformities wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp306

    authors: Abul-Kasim K

    更新日期:2010-04-01 00:00:00

  • ANALYSIS BY SCANNER OF TRACKS PRODUCED BY RADON ALPHA PARTICLES IN CR-39 DETECTORS.

    abstract::The most used passive detectors for Radon measurement are the CR39s, both for the good stability of the material and for the practicality of use. But, commercial reading systems are expensive and not always fast. The aim of the present work was the development of a method for a rapid, efficient and economic evaluation...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa140

    authors: Sabbarese C,Ambrosino F,Roca V

    更新日期:2020-11-27 00:00:00

  • Entrance surface, organ and effective doses for some of the patients undergoing different types of X ray procedures in Bangladesh.

    abstract::Entrance surface doses (ESDs) were measured for the most common types of X ray procedures, such as chest PA, lumber spine AP, lumber spine lateral, skull AP, skull lateral and pelvis AP in four major hospitals of Dhaka, the capital city of Bangladesh. Organ/tissue doses for 29 organs/tissues and effective doses for th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006549

    authors: Begum Z

    更新日期:2001-01-01 00:00:00

  • Gamma-ray emitting test sources for Portal Monitors used for homeland security.

    abstract::The National Institute of Standards and Technology developed a new set of test sources for testing of portal monitors against the ANSI standard N42.35-2004. The design and source specifications are provided in this work. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch422

    authors: Lucas L,Pibida L,Unterweger M,Karam L

    更新日期:2005-01-01 00:00:00

  • Radiation-induced non-targeted effects: some open questions.

    abstract::The existence of non-targeted effects (NTEs) of radiation (genomic instability and bystander effects) has been generally accepted for >20 y; however, there is research, which was largely ignored going back to 1915 reporting these effects. Despite today's general acceptance of the phenomenon of NTE, there is little agr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncv155

    authors: Mothersill C,Seymour C

    更新日期:2015-09-01 00:00:00

  • Time-integrated monitoring of thoron progeny concentration around closed uranium mine sites in Japan.

    abstract::Thoron progeny concentrations were determined using the time-integrated method around closed uranium mine sites in Japan. Because the time-integrated radon progeny monitor developed by the authors has the function to detect (212)Po, time-integrated monitoring of thoron progeny concentration is also available with the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq242

    authors: Ishimori Y

    更新日期:2010-10-01 00:00:00