Image based evaluation of mediastinal constraints for the development of a pulsatile total artificial heart.

Abstract:

BACKGROUND:Good anatomical compatibility is an important aspect in the development of cardiovascular implants. This work analyzes the interaction of the pump unit of an electrically driven pulsatile Total Artificial Heart (TAH) and the mediastinum. For an adequate compliance, both overall dimensions and alignment of inlets and outlets must be matched. METHODS:Cross-sectional medical image data of 27 individuals, including male and female patients suffering from end stage heart failure, was segmented and reconstructed to three dimensional (3D) surface models. Dimensions and orientations of relevant structures were identified and analyzed. The TAH surface model was virtually placed in orthotopic position and aligned with atrioventricular valves and big vessels. Additionally seven conventional cadaver studies were performed to validate different pump chamber designs based on virtual findings. Thereby 3D-coordinates were captured and introduced to the virtual environment to allow quantitative comparison between different individuals. RESULTS:Spatial parameters varied more in male patients with higher values if heart failure persists. Good correlation of the virtual analysis both to literature data and conventional cadaver studies could be shown. The full data of the 27 individuals as well as the summarized values found in literature are enclosed in the appendix. By superimposing the TAH-volume model to the anatomy, various misalignments were found and the TAH-design was adjusted. CONCLUSIONS:Virtual fitting allows implant design adjustments in realistic anatomy which has not been influenced by thoracotomy. Higher numbers of relevant individuals can be reasonably investigated in the virtual environment and quantitatively correlated. Using this approach, conventional cadaver studies can be significantly reduced but not obviated, due to the unavailable haptic feedback and immobility of potentially compressed structures.

journal_name

Biomed Eng Online

authors

Fritschi AJ,Laumen M,Spiliopoulos S,Finocchiaro T,Egger C,Schmitz-Rode T,Tenderich G,Koerfer R,Steinseifer U

doi

10.1186/1475-925X-12-81

subject

Has Abstract

pub_date

2013-08-14 00:00:00

pages

81

issn

1475-925X

pii

1475-925X-12-81

journal_volume

12

pub_type

杂志文章
  • Study on the biomechanical responses of the loaded bone in macroscale and mesoscale by multiscale poroelastic FE analysis.

    abstract:BACKGROUND:Bone is a hierarchically structured composite material, and different hierarchical levels exhibit diverse material properties and functions. The stress and strain distribution and fluid flow in bone play an important role in the realization of mechanotransduction and bone remodeling. METHODS:To investigate ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0741-3

    authors: Yu W,Wu X,Cen H,Guo Y,Li C,Wang Y,Qin Y,Chen W

    更新日期:2019-12-23 00:00:00

  • Identification of heart rate dynamics during moderate-to-vigorous treadmill exercise.

    abstract:BACKGROUND:Heart rate can be used to prescribe exercise intensity for development and maintenance of cardiorespiratory fitness. The aim of this study was to identify the dynamics of heart rate response during moderate-to-vigorous treadmill exercise and to explore parameter dependencies with respect to time, intensity l...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0112-7

    authors: Hunt KJ,Fankhauser SE,Saengsuwan J

    更新日期:2015-12-21 00:00:00

  • Review of cognitive behavioural therapy mobile apps using a reference architecture embedded in the patient-provider relationship.

    abstract:BACKGROUND:Mobile health apps (mHealth apps) are increasing in popularity and utility for the management of many chronic diseases. Although the current reimbursement structure for mHealth apps is lagging behind the rapidly improving functionality, more clinicians will begin to recommend these apps as they prove their c...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0611-4

    authors: Lan A,Lee A,Munroe K,McRae C,Kaleis L,Keshavjee K,Guergachi A

    更新日期:2018-12-17 00:00:00

  • Evaluation of flow changes after telescopic stenting of a giant fusiform aneurysm of the vertebrobasilar junction.

    abstract:BACKGROUND:The use of flow-diverters for non-saccular cerebral posterior circulation aneurysms requires complex deployment techniques and is associated with high mortality and morbidity. Therefore, further studies are required to clarify the effect of stenting on post-treatment hemodynamics in such aneurysms. In this s...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0699-1

    authors: Sindeev S,Kirschke JS,Prothmann S,Frolov S,Liepsch D,Berg P,Zimmer C,Friedrich B

    更新日期:2019-07-24 00:00:00

  • The effect of inlet and outlet boundary conditions in image-based CFD modeling of aortic flow.

    abstract:BACKGROUND:Computational modeling of cardiovascular flow is a growing and useful field, but such simulations usually require the researcher to guess the flow's inlet and outlet conditions since they are difficult and expensive to measure. It is critical to determine the amount of uncertainty introduced by these assumpt...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0497-1

    authors: Madhavan S,Kemmerling EMC

    更新日期:2018-05-30 00:00:00

  • In memorium: Herman p. Schwan [1915-2005].

    abstract::Herman P. Schwan [1915-2005] was a distinguished scientist and engineer, and a founding father of the field of biomedical engineering. A man of integrity, Schwan influenced the lives of many, including his wife and children, and his many students and colleagues. Active in science until nearly the end of his life, he w...

    journal_title:Biomedical engineering online

    pub_type: 传,历史文章,杂志文章

    doi:10.1186/1475-925X-4-21

    authors: Foster KR

    更新日期:2005-03-25 00:00:00

  • On the design of a DEA-based device to pot entially assist lower leg disorders: an analytical and FEM investigation accounting for nonlinearities of the leg and device deformations.

    abstract:BACKGROUND:One of the recommended treatments for disorders associated with the lower extremity venous insufficiency is the application of external mechanical compression. Compression stockings and elastic bandages are widely used for the purpose of compression therapy and are usually designed to exert a specified value...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0088-3

    authors: Pourazadi S,Ahmadi S,Menon C

    更新日期:2015-11-05 00:00:00

  • Objective assessment of spasticity by pendulum test: a systematic review on methods of implementation and outcome measures.

    abstract:BACKGROUND:Instrumented pendulum test is an objective and repeatable biomechanical method of assessment for spasticity. However, multitude of sensor technologies and plenty of suggested outcome measures, confuse those interested in implementing this method in practice. Lack of a standard agreement on the definition of ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-020-00826-8

    authors: Rahimi F,Eyvazpour R,Salahshour N,Azghani MR

    更新日期:2020-11-09 00:00:00

  • Hemodynamic effects of perfusion level of peripheral ECMO on cardiovascular system.

    abstract:BACKGROUND:Peripheral ECMO is an effective cardiopulmonary support in clinical. The perfusion level could directly influence the performances and complications. However, there are few studies on the effects of the perfusion level on hemodynamics of peripheral ECMO. METHODS:The geometric model of cardiovascular system ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0493-5

    authors: Gu K,Zhang Z,Gao B,Chang Y,Wan F

    更新日期:2018-05-09 00:00:00

  • In vivo and in vitro performance of a China-made hemodialysis machine: a multi-center prospective controlled study.

    abstract:OBJECTIVE:To evaluate the in vivo and in vitro performance of a China-made dialysis machine (SWS-4000). METHODS:This was a multi-center prospective controlled study consisting of both long-term in vitro evaluations and cross-over in vivo tests in 132 patients. The China-made SWS-4000 dialysis machine was compared with...

    journal_title:Biomedical engineering online

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1186/s12938-017-0387-y

    authors: Wang Y,Chen XM,Cai GY,Li WG,Zhang AH,Hao LR,Shi M,Wang R,Jiang HL,Luo HM,Zhang D,Sun XF

    更新日期:2017-08-02 00:00:00

  • Examination of ceramic restoration adhesive coverage in cusp-replacement premolar using acoustic emission under fatigue testing.

    abstract:BACKGROUND:This study investigates CAD/CAM ceramic cusp-replacing restoration resistance with and without buccal cusp replacement under static and dynamic cyclic loads, monitored using the acoustic emission (AE) technique. METHOD:The cavity was designed in a typical MODP (mesial-occlusal-distal-palatal) restoration fa...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-165

    authors: Chang YH,Yu JJ,Lin CL

    更新日期:2014-12-13 00:00:00

  • Telepointer technology in telemedicine: a review.

    abstract::Telepointer is a powerful tool in the telemedicine system that enhances the effectiveness of long-distance communication. Telepointer has been tested in telemedicine, and has potential to a big influence in improving quality of health care, especially in the rural area. A telepointer system works by sending additional...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-12-21

    authors: Abdul Karim R,Zakaria NF,Zulkifley MA,Mustafa MM,Sagap I,Md Latar NH

    更新日期:2013-03-09 00:00:00

  • Mechanical strain promotes osteoblast ECM formation and improves its osteoinductive potential.

    abstract:BACKGROUND:The extracellular matrix (ECM) provides a supportive microenvironment for cells, which is suitable as a tissue engineering scaffold. Mechanical stimulus plays a significant role in the fate of osteoblast, suggesting that it regulates ECM formation. Therefore, we investigated the influence of mechanical stimu...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-80

    authors: Guo Y,Zhang CQ,Zeng QC,Li RX,Liu L,Hao QX,Shi CH,Zhang XZ,Yan YX

    更新日期:2012-10-25 00:00:00

  • Three-dimensional dominant frequency mapping using autoregressive spectral analysis of atrial electrograms of patients in persistent atrial fibrillation.

    abstract:BACKGROUND:Areas with high frequency activity within the atrium are thought to be 'drivers' of the rhythm in patients with atrial fibrillation (AF) and ablation of these areas seems to be an effective therapy in eliminating DF gradient and restoring sinus rhythm. Clinical groups have applied the traditional FFT-based a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0143-8

    authors: Salinet JL,Masca N,Stafford PJ,Ng GA,Schlindwein FS

    更新日期:2016-03-08 00:00:00

  • Home-based system for physical activity monitoring in patients with multiple sclerosis (Pilot study).

    abstract:BACKGROUND:Limitations in physical activity are considered as a key problem in patients with multiple sclerosis (PwMS). Contemporary methods to assess the level of physical activity in PwMS are regular clinical observation. However, these methods either rely on high recall and accurate reporting from the patients (e.g....

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-10

    authors: Shammas L,Zentek T,von Haaren B,Schlesinger S,Hey S,Rashid A

    更新日期:2014-02-06 00:00:00

  • Real-time feature extraction of P300 component using adaptive nonlinear principal component analysis.

    abstract:BACKGROUND:The electroencephalography (EEG) signals are known to involve the firings of neurons in the brain. The P300 wave is a high potential caused by an event-related stimulus. The detection of P300s included in the measured EEG signals is widely investigated. The difficulties in detecting them are that they are mi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-83

    authors: Turnip A,Hong KS,Jeong MY

    更新日期:2011-09-23 00:00:00

  • Challenges on optimization of 3D-printed bone scaffolds.

    abstract::Advances in biomaterials and the need for patient-specific bone scaffolds require modern manufacturing approaches in addition to a design strategy. Hybrid materials such as those with functionally graded properties are highly needed in tissue replacement and repair. However, their constituents, proportions, sizes, con...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-020-00810-2

    authors: Bahraminasab M

    更新日期:2020-09-03 00:00:00

  • Noise reduction of diffusion tensor images by sparse representation and dictionary learning.

    abstract:BACKGROUND:The low quality of diffusion tensor image (DTI) could affect the accuracy of oncology diagnosis. METHODS:We present a novel sparse representation based denoising method for three dimensional DTI by learning adaptive dictionary with the context redundancy between neighbor slices. In this study, the context r...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0116-3

    authors: Kong Y,Li Y,Wu J,Shu H

    更新日期:2016-01-13 00:00:00

  • Monitoring and analysis of dynamic growth of human embryonic stem cells: comparison of automated instrumentation and conventional culturing methods.

    abstract:BACKGROUND:Human embryonic stem cells (hESCs) are a potential source of cells for use in regenerative medicine. Automation of culturing, monitoring and analysis is crucial for fast and reliable optimization of hESC culturing methods. Continuous monitoring of living cell cultures can reveal more information and is faste...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-11

    authors: Narkilahti S,Rajala K,Pihlajamäki H,Suuronen R,Hovatta O,Skottman H

    更新日期:2007-04-12 00:00:00

  • A computational model study of the influence of the anatomy of the circle of willis on cerebral hyperperfusion following carotid artery surgery.

    abstract:BACKGROUND:Cerebral hyperperfusion syndrome develops in a small subset of patients following carotid artery surgery (CAS) performed to treat severe carotid artery stenosis. This syndrome has been found to have a close correlation with cerebral hyperperfusion occurring after CAS. The purpose of this study is to investig...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-84

    authors: Liang F,Fukasaku K,Liu H,Takagi S

    更新日期:2011-09-23 00:00:00

  • A specialized motion capture system for real-time analysis of mandibular movements using infrared cameras.

    abstract:BACKGROUND:In the last years, several methods and devices have been proposed to record the human mandibular movements, since they provide quantitative parameters that support the diagnosis and treatment of temporomandibular disorders. The techniques currently employed suffer from a number of drawbacks including high pr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-17

    authors: Furtado DA,Pereira AA,Andrade Ade O,Bellomo DP Jr,da Silva MR

    更新日期:2013-02-22 00:00:00

  • A numerical study of the effect of varied blood pressure on the stability of carotid atherosclerotic plaque.

    abstract:BACKGROUND:Blood pressure (BP) is associated with early atherosclerosis and plaque rupture because the BP variability can significantly affect the blood flow velocity and shear stress over the plaque. However, the mechanical response of BP variability to the plaque remains unclear. Therefore, we investigated the correl...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-152

    authors: Xiong H,Liu X,Tian X,Pu L,Zhang H,Lu M,Huang W,Zhang YT

    更新日期:2014-11-20 00:00:00

  • Flow and wall shear stress in end-to-side and side-to-side anastomosis of venous coronary artery bypass grafts.

    abstract:PURPOSE:Coronary artery bypass graft (CABG) surgery represents the standard treatment of advanced coronary artery disease. Two major types of anastomosis exist to connect the graft to the coronary artery, i.e., by using an end-to-side or a side-to-side anastomosis. There is still controversy because of the differences ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-35

    authors: Frauenfelder T,Boutsianis E,Schertler T,Husmann L,Leschka S,Poulikakos D,Marincek B,Alkadhi H

    更新日期:2007-09-26 00:00:00

  • Biomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture.

    abstract:BACKGROUND:Although use of a dynamic hip screw (DHS) for stable intertrochanteric hip fracture fixation has been successfully applied in fracture healing for more than 20 years, DHS fixation on unstable intertrochanteric fractures still has a high failure rate, especially in patients with osteoporosis. Although the wir...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0663-0

    authors: Wu HF,Chang CH,Wang GJ,Lai KA,Chen CH

    更新日期:2019-04-24 00:00:00

  • Investigations concerning the application of the cross-correlation method in cardiac output measurements.

    abstract:BACKGROUND:In spite of numerous non-invasive examinations the "gold clinical standard" of cardiac output measurements is the invasive pulmonary artery catheterization by means of the Swan-Ganz catheter and the application of the thermodilution method to estimate the blood flow. The results obtained by means of thermodi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-24

    authors: Gawlikowski M,Pustelny T

    更新日期:2012-05-20 00:00:00

  • Modeling and classification of gait patterns between anterior cruciate ligament deficient and intact knees based on phase space reconstruction, Euclidean distance and neural networks.

    abstract:BACKGROUND:The anterior cruciate ligament (ACL) plays an important role in stabilizing translation and rotation of the tibia relative to the femur. ACL injury alters knee kinematics and usually links to the alternation of gait patterns. The aim of this study is to develop a new method to distinguish between gait patter...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0594-1

    authors: Wu W,Zeng W,Ma L,Yuan C,Zhang Y

    更新日期:2018-11-01 00:00:00

  • Quantification of compensatory processes of postnatal hypoxia in newborn piglets applying short-term nonlinear dynamics analysis.

    abstract:BACKGROUND:Newborn mammals suffering from moderate hypoxia during or after birth are able to compensate a transitory lack of oxygen by adapting their vital functions. Exposure to hypoxia leads to an increase in the sympathetic tone causing cardio-respiratory response, peripheral vasoconstriction and vasodilatation in p...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-88

    authors: Schulz S,Reulecke S,Eiselt M,Schwab K,Witte H,Walter B,Bauer R,Voss A

    更新日期:2011-10-03 00:00:00

  • Voluntary EMG-to-force estimation with a multi-scale physiological muscle model.

    abstract:BACKGROUND:EMG-to-force estimation based on muscle models, for voluntary contraction has many applications in human motion analysis. The so-called Hill model is recognized as a standard model for this practical use. However, it is a phenomenological model whereby muscle activation, force-length and force-velocity prope...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-86

    authors: Hayashibe M,Guiraud D

    更新日期:2013-09-04 00:00:00

  • Developing functional workspace for the movement of trunk circumduction in healthy young subjects: a reliability study.

    abstract:BACKGROUND:The lumbar range of motion has traditionally been used to assess disability in patients with low back disorders. Controversy exists about how movement ranges in static positions or in a single straight plane is related to the functional status of the patients. The trunk circumduction, as the result of neurom...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-4

    authors: Cheng SC,Hsu CH,Ting YT,Kuo LC,Lin RM,Su FC

    更新日期:2013-01-11 00:00:00

  • Human coronary plaque wall thickness correlated positively with flow shear stress and negatively with plaque wall stress: an IVUS-based fluid-structure interaction multi-patient study.

    abstract:BACKGROUND:Atherosclerotic plaque progression and rupture are believed to be associated with mechanical stress conditions. In this paper, patient-specific in vivo intravascular ultrasound (IVUS) coronary plaque image data were used to construct computational models with fluid-structure interaction (FSI) and cyclic bend...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-32

    authors: Fan R,Tang D,Yang C,Zheng J,Bach R,Wang L,Muccigrosso D,Billiar K,Zhu J,Ma G,Maehara A,Mintz GS

    更新日期:2014-03-26 00:00:00