Abstract:
RATIONALE AND OBJECTIVES:The purpose of this study was to determine the acquisition and interpretation times of screen-film mammography and soft-copy digital mammography in a diagnostic mammography center. MATERIALS AND METHODS:The study was conducted in three phases for patients presenting for clinical diagnostic workup to a mammography clinic. In the first phase, technologist acquisition and processing times and radiologist interpretation time were measured for patients imaged with a screen-film mammographic system. During the second phase of the study, times were measured for patients imaged with a direct radiographic digital mammographic system, with interpretation performed on a soft-copy display system. During the third phase, 3 months after installation of the soft-copy display system, times were measured again for patients imaged on the same direct radiographic digital mammographic system, with interpretation with the same soft-copy system. The same four experienced breast imaging radiologists and seven technologists participated in all phases of the study. All data were entered into a database, and statistical analysis was conducted using weighted linear models and logarithmic transformation. RESULTS:Times were obtained for 295 patients. There were 100 patients each for phases 1 and 2 and 95 patients for phase 3. Diagnostic mammographic acquisition times with processing were 13.02 min/case for screen film (phase 1), 8.16 min/case for digital (phase 2), and 10.66 min/case for digital (phase 3) (P < .001 and P < .0001, respectively). In addition, the radiologist interpretation time for digital mammography in both phases was not significantly different from that for film mammography (P = .2853 and P = .2893, respectively). There was no significant difference between phases 2 and 3 (P = 1.0000). The mean interpretation times were 3.75 min/case for screen film, 2.14 min/case for digital (phase 2), and 2.26 min/case for digital (phase 3). CONCLUSIONS:Digital mammography significantly shortened the acquisition time for diagnostic mammography. There was no significant difference in interpretation time compared to screen-film mammography in a diagnostic mammography setting.
journal_name
Acad Radioljournal_title
Academic radiologyauthors
Kuzmiak CM,Cole E,Zeng D,Kim E,Koomen M,Lee Y,Pavic D,Pisano EDdoi
10.1016/j.acra.2010.04.018subject
Has Abstractpub_date
2010-09-01 00:00:00pages
1168-74issue
9eissn
1076-6332issn
1878-4046pii
S1076-6332(10)00245-Xjournal_volume
17pub_type
杂志文章abstract:RATIONALE AND OBJECTIVES:Our purpose in this study was to develop an automated computer-aided volumetry (CAV) scheme for quantifying pneumothorax in multidetector computed tomography (MDCT) images for pediatric patients and to investigate the imaging parameters that may affect its accuracy. MATERIALS AND METHODS:Fifty...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2010.11.008
更新日期:2011-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study aimed to determine the preferences of radiology and referring provider residents regarding direct communication of radiology test results. METHODS:This Health Insurance Portability and Accountability Act-compliant quality improvement effort was exempt from institutional review board...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2017.09.015
更新日期:2018-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate cone beam computed tomography (CBCT) for monitoring of tibial bone defect healing in comparison to histopathological findings. MATERIALS AND METHODS:Circumscribed tibial bone defects were created in 16 mini-pigs and imaging of the tibia was performed on day 42 using a modern CBCT s...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2011.10.022
更新日期:2012-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study aimed to determine the appropriate body mass index (BMI)-dependent noise index (NI) setting in computed tomography pulmonary angiography (CTPA) with automatic tube current modulation with adaptive statistical iterative reconstruction (ASiR). MATERIALS AND METHODS:A total of 480 pati...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2016.07.018
更新日期:2016-12-01 00:00:00
abstract::Technologic advances have resulted in the expansion of web-based conferencing and education. While historically video-conferencing has been used for didactic educational sessions, we present its novel use in virtual radiology read-outs in the face of the COVID-19 pandemic. Knowledge of key aspects of set-up, implement...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2020.04.028
更新日期:2020-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The study aim is to evaluate the quality of radiology requisitions for plain film radiographs on intensive care unit (ICU) patients. MATERIALS AND METHODS:Radiology requisitions for 58 patients in ICU units at our children's hospital and the corresponding original orders for the study, written...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2005.10.017
更新日期:2006-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:In our earlier studies, we reported an evidence-based computer-assisted decision (CAD) system for location-specific interrogation of mammograms. A content-based image retrieval framework with information theoretic (IT) similarity measures serves as the foundation for this system. Specifically, ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2007.12.013
更新日期:2008-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of this study was to compare the diagnostic accuracy of 64-slice computed tomographic coronary angiography (CTCA) in groups of patients with low, intermediate, and high risk for coronary artery disease (CAD) events. MATERIALS AND METHODS:The institutional review board approved this stu...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2007.12.008
更新日期:2008-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:We introduce a new approach to the prediction of final infarct growth in human acute ischemic stroke based on image analysis of the apparent diffusion coefficient (ADC) maps obtained from magnetic resonance imaging. Evidence from multiple previous studies indicate that ADC maps are likely to re...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2007.07.007
更新日期:2008-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Multireader imaging trials often use a factorial design, in which study patients undergo testing with all imaging modalities and readers interpret the results of all tests for all patients. A drawback of this design is the large number of interpretations required of each reader. Split-plot desi...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2012.09.012
更新日期:2012-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Surgeons aim to restore occlusion and jaw function to baseline status for patients with mandibular fractures using either closed treatment or reduction and fixation. MATERIALS AND METHODS:Occlusion is defined as the relationship between the maxillary and mandibular teeth as they approach each ...
journal_title:Academic radiology
pub_type: 杂志文章,评审
doi:10.1016/j.acra.2018.06.009
更新日期:2019-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Scanning parameters used in multislice computed tomographic (MSCT) coronary angiography should be adapted to patients' heart rates. The aim of this study was to evaluate the rate of success of a software-assisted scan simulation to determine optimal gantry rotation time prior to MSCT coronary a...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2008.08.016
更新日期:2009-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the feasibility and performance of an x-ray beam equalization system for chest radiography using anthropomorphic phantoms. MATERIALS AND METHODS:Area beam equalization involves the process of the initial unequalized image acquisition, attenuator thickness calculation, mask generati...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(03)00730-x
更新日期:2004-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors evaluated whether fast spectroscopic imaging of water and fat resonances can produce high-quality anatomic magnetic resonance (MR) images of rodent tumors and human breast. MATERIALS AND METHODS:Fast MR spectroscopic images of eight rats with mammary tumors were acquired by using a...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(98)80226-2
更新日期:1998-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The American Association of Academic Chief Residents in Radiology annually surveys residency programs on a variety of issues related to residency training. The survey results allow individual programs to compare features of their programs with national averages and to gauge trends in radiology ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(98)80288-2
更新日期:1998-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate whether a computer-aided diagnosis (CADx) technique can accurately classify breast calcifications in full-field digital mammograms (FFDMs) as malignant or benign. The computer technique was developed previously on screen-film mammograms (SFMs) in which individual calcifications were...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2006.12.012
更新日期:2007-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The objective of this study was to develop and quantitatively evaluate a radiology-pathology fusion method for spatially mapping tissue regions corresponding to different chemoradiation therapy-related effects from surgically excised whole-mount rectal cancer histopathology onto preoperative ma...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2017.12.006
更新日期:2018-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of this study was to evaluate the intratumoral residence time of microbubbles (MBs) targeted to alpha(v)beta(3) integrin expressed in the endothelial cells of mice during the process of tumor angiogenesis. MATERIALS AND METHODS:For the preparation of MBs, decafluorobutane gas was sonic...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2009.07.017
更新日期:2010-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors compared magnetic resonance (MR) image quality obtained from 3- and 1-mm-thick sections in the depiction of the temporomandibular joint (TMJ) and its adjacent structures. MATERIALS AND METHODS:Eight TMJ specimens from four adult cadaver heads were depicted with MR imaging. Both 3- ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/S1076-6332(99)80116-0
更新日期:1999-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Acoustic noise both in terms of its magnitude and frequency during magnetic resonance imaging (MRI) scan is influenced by imaging parameters and pulse sequences. It varies because of many different factors such as structure, materials, and magnetic field strength. The purpose of our study is to...
journal_title:Academic radiology
pub_type: 杂志文章,多中心研究
doi:10.1016/j.acra.2010.09.009
更新日期:2011-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Prospective studies of radiologists' interpretations of selected radiographs reported 20-40 years ago indicated error rates of 30% and higher. The authors retrospectively evaluated the interpretations of groups of radiologists and determined a range of rates of disagreement in interpretation. Q...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(98)80277-8
更新日期:1998-03-01 00:00:00
abstract:PURPOSE:To evaluate diagnostic accuracy and clinical outcomes of patients with porcelain gallbladder (GB) diagnosed on CT. MATERIALS AND METHODS:In this IRB-approved, HIPAA-compliant study, consecutive patients with porcelain gallbladder reported on CT between December 1, 2000 and August 31, 2017 in a tertiary academi...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2020.07.006
更新日期:2020-08-04 00:00:00
abstract:RATIONALE AND OBJECTIVES:The lack of understanding of the real costs (not charge) of delivering healthcare services poses tremendous challenges in the containment of healthcare costs. In this study, we applied an established cost accounting method, the time-driven activity-based costing (TDABC), to assess the costs of ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2016.11.001
更新日期:2017-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:We investigated a computer-aided detection (CAD) scheme for clustered microcalcifications in digitized mammograms. METHODS:A multistage CAD scheme was developed and tested. To increase sensitivity, the scheme uses a Gaussian band-pass filter and nonlinear threshold. A multistage local minimum ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(05)80431-3
更新日期:1995-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study compared the safety and efficacy of iodixanol with those of ioxaglate in adult patients undergoing aortography or peripheral arteriography. METHODS:Forty-six patients were enrolled in this controlled, randomized, double-blind, two-center study. The patients were monitored for advers...
journal_title:Academic radiology
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1016/s1076-6332(05)80368-x
更新日期:1996-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors developed a computerized method for delineating the costophrenic angles in digital posteroanterior chest radiographs to derive quantitative information that allows for detection of abnormal blunting of the costophrenic angle. MATERIALS AND METHODS:An automated lung-segmentation sch...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(98)80151-7
更新日期:1998-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Assess whether staff training in advanced rapport skills and self-hypnotic relaxation techniques reduces noncompletion rates during magnetic resonance imaging (MRI). METHODS AND MATERIALS:All staff of a free-standing MRI facility was invited to 3 hours of preparatory communication lectures. Ha...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2009.07.002
更新日期:2010-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To assess the usefulness of classifying degree of difficulty in abnormality detection and to determine the effect of knowing the true diagnosis when selecting subtle images for observer-performance studies. MATERIALS AND METHODS:A total of 529 posteroanterior chest images that had been used in...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(98)80127-x
更新日期:1998-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:A number of studies have reported decreases in fractional anistropy (FA) in amyotrophic lateral sclerosis using diffusion tensor imaging (DTI). The purpose of this study was to perform a meta-analysis in order to estimate the diagnostic test accuracy measures of DTI for the diagnosis of amyotro...
journal_title:Academic radiology
pub_type: 杂志文章,meta分析
doi:10.1016/j.acra.2012.04.012
更新日期:2012-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVE:Abnormal neurodevelopment may play a role in the pathophysiology of schizophrenia. We used deformation-based morphometry to examine voxel-wise age-related changes in patients with schizophrenia compared with healthy brains. MATERIALS AND METHODS:We used a set of skull-stripped brains from an im...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2004.06.009
更新日期:2005-01-01 00:00:00