Abstract:
RATIONALE AND OBJECTIVES:To evaluate the feasibility and performance of an x-ray beam equalization system for chest radiography using anthropomorphic phantoms. MATERIALS AND METHODS:Area beam equalization involves the process of the initial unequalized image acquisition, attenuator thickness calculation, mask generation using a 16 x 16 piston array, and final equalized image acquisition. Chest radiographs of three different anthropomorphic phantoms were acquired with no beam equalization and equalization levels of 4.8, 11.3, and 21. Six radiologists evaluated the images by scoring them from 1-5 using 13 different criteria. The dose was calculated using the known attenuator material thickness and the mAs of the x-ray tube. RESULTS:The visibility of anatomic structures in the under-penetrated regions of the chest radiographs was shown to be significantly (P < .01) improved after beam equalization. An equalization level of 4.8 provided most of the improvements with moderate increases in patient dose and tube loading. Higher levels of beam equalization did not show much improvement in the visibility of anatomic structures in the under-penetrated regions. CONCLUSION:A moderate level of x-ray beam equalization in chest radiography is superior to both conventional radiographs and radiographs with high levels of beam equalization. X-ray beam equalization can significantly improve the visibility of anatomic structures in the under-penetrated regions while maintaining good image quality in the lung region.
journal_name
Acad Radioljournal_title
Academic radiologyauthors
Xu T,Shikhaliev PM,Berenji GR,Tehranzadeh J,Saremi F,Molloi Sdoi
10.1016/s1076-6332(03)00730-xkeywords:
subject
Has Abstractpub_date
2004-04-01 00:00:00pages
377-89issue
4eissn
1076-6332issn
1878-4046journal_volume
11pub_type
杂志文章abstract:RATIONALE AND OBJECTIVES:The aim of the study is to evaluate the effectiveness of an Emergency Radiology (ER) Core Curriculum training module and a Digital Imaging and Communications in Medicine (DICOM)-based interactive examination system to prepare first-year (postgraduate year 2 [PGY-2]) radiology residents and asse...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2006.02.057
更新日期:2006-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate conspicuity of screen-detected cancers on two-dimensional synthetic mammography (SM) reconstructed from digital breast tomosynthesis (DBT) compared to two-dimensional full field digital mammography (FFDM). MATERIALS AND METHODS:IRB-approved retrospective review of consecutive scree...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2019.06.008
更新日期:2020-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of this study was to investigate the effects of exogenous endothelial progenitor cells (EPCs) on the growth and invasiveness of glioma in vivo to provide an experimental basis for the value and safety of using magnetically labeled EPCs as target vectors to detect early infiltration of g...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2011.02.017
更新日期:2011-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Early loss of a sensory modality has been associated with cortical reorganization in both animal models and humans. The purpose of this study was to map visual activation with functional magnetic resonance (MR) imaging and to document possible developmental reorganization in the temporal lobe c...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/S1076-6332(03)80684-0
更新日期:2001-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of this study was to determine the sonographic visibility of implanted collagen-based breast biopsy marker clips in the clinic and operating room. MATERIALS AND METHODS:Female patients aged > or =18 years who presented for preoperative surgical evaluation within 4 weeks of ultrasound-g...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2009.10.017
更新日期:2010-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors compared diagnostic accuracy and callback rates with conventional screen-film mammograms and wavelet-compressed digitized images. MATERIALS AND METHODS:Sixty sets of mammograms (four views per case) were digitized at a spatial resolution of 100 microm. The images were wavelet compr...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(00)80004-5
更新日期:2000-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:With the introduction of new communication channels, such as encrypted messaging and online electronic medical record patient portals, there are ever-increasing ways for patients and their families to access their medical information. While patient preferences regarding how they receive the res...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2019.07.010
更新日期:2020-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:We compared the peritumoral vascular definition in rats using either a paramagnetic extracellular or a macromolecular contrast medium in combination with high-resolution magnetic resonance (MR) imaging. METHODS:High-resolution, three-dimensional spoiled gradient-refocused acquisition in a stea...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(05)80059-5
更新日期:1995-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:A method is presented to track guide wires during endovascular interventions under X-ray fluoroscopy. Accurate guide wire tracking can be used to improve guide wire visualization in the low quality fluoroscopic images, and to estimate the position of the guide wire in world coordinates for navi...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(03)00539-7
更新日期:2003-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study aimed to develop and implement a respiratory-gated setup for dual-source computed tomography (CT) at high pitch to examine patients in a reproducible inspiratory phase. MATERIALS AND METHODS:Twenty-one patients underwent free-breathing respiratory-gated chest CT using a high-pitch s...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2015.12.018
更新日期:2016-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Urinary calculi are now commonly detected with helical computed tomography (CT), and it has been proposed that stone composition can be determined from CT attenuation values. However, typical scans are made with a beam collimation of 5 mm or more, resulting in volume averaging and reduction in ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/S1076-6332(03)80619-0
更新日期:2001-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Balloon dilatation is a mechanical form of controlled injury used to alleviate vascular stenoses. Several factors influence successful angioplasty. Few mechanical models exist to illustrate the physical principles of balloon dilatation. METHODS:We used mechanical analysis of membrane stresses,...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(05)80340-x
更新日期:1995-05-01 00:00:00
abstract::Initial research in the development of interventional magnetic resonance (MR) imaging in the late 1980s and early to mid-1990s focused on pulse sequences, devices, and clinical applications. This focus was largely a result of the limited number of areas in which the academic research community leading the development ...
journal_title:Academic radiology
pub_type: 杂志文章,评审
doi:10.1016/j.acra.2005.06.003
更新日期:2005-09-01 00:00:00
abstract:RATIONAL AND OBJECTIVES:Computer-aided detection (CAD) systems are intended to improve performance. This study investigates how CAD might actually interfere with a visual search task. This is a laboratory study with implications for clinical use of CAD. METHODS:Forty-seven naive observers in two studies were asked to ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2012.05.013
更新日期:2012-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of this study was to assess if graphical user interface screen-capture software applied to a magnetic resonance (MR) hardware console could nonintrusively allow the analysis of discrepancies between expected and experienced MR table time. MATERIALS AND METHODS:Individual MR examination...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2009.05.009
更新日期:2009-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To retrospectively analyze the significance of 3.0-T contrast-enhanced (CE) magnetic resonance angiography (MRA) with calf compression in the lower limbs of diabetic patients with peripheral vascular disease. MATERIALS AND METHODS:Sixty-one type 2 diabetes patients underwent both MRA and digit...
journal_title:Academic radiology
pub_type: 杂志文章,随机对照试验
doi:10.1016/j.acra.2011.01.013
更新日期:2011-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Because several factors are involved in cancer detection, a malignant lesion that is visible on a mammogram will not necessarily be reported by the radiologist reading the case. Indeed, a significant fraction of screening-detected cancers are visible in retrospect, and were perceived by the rad...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2004.04.015
更新日期:2004-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Pulmonary vascular alteration is one of the characteristic features of chronic obstructive pulmonary disease (COPD). Recent studies suggest that vascular alteration is closely related to endothelial dysfunction and may be further influenced by emphysema. However, the relationship between morpho...
journal_title:Academic radiology
pub_type: 临床试验,杂志文章
doi:10.1016/j.acra.2009.07.022
更新日期:2010-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Improvements in imaging technology have led to the increased use of computed tomography (CT). For example, micro-CT and quantitative CT (QCT) are now often used in osteoporosis research, in which micro-CT is able to analyze small bones or bone samples with high spatial resolution. In contrast, ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2008.09.017
更新日期:2009-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Four-dimensional (4D) computed tomography (CT) can be used in radiation treatment planning to account for respiratory motion. Current 4D CT techniques have limitations in either spatial or temporal resolution. In addition, most of these techniques rely on auxiliary surrogates to relate the time...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2006.05.004
更新日期:2006-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To investigate the relationship between apparent diffusion coefficient (ADC) values and the Ki-67 staining index (Ki-67 SI), a tumor proliferation marker, in prostate cancer (PCa). MATERIALS AND METHODS:Forty-three patients with PCa and thirty-six patients with benign prostatic hyperplasia (BP...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2013.09.007
更新日期:2013-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Estimation of regional lung function parameters from hyperpolarized gas magnetic resonance images can be very sensitive to presence of noise. Clustering pixels and averaging over the resulting groups is an effective method for reducing the effects of noise in these images, commonly performed by...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2008.03.002
更新日期:2008-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Mammographic breast density is an important and widely accepted risk factor for breast cancer. A statement about breast density in the mammographic report is becoming a requirement in many States. However, there is significant inter-observer variation between radiologists in their interpretatio...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2011.07.011
更新日期:2011-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To determine the differences in the psychosocial effects and future mammography screening behavior between women who had an abnormal mammogram followed either by percutaneous or open surgical breast biopsy or cyst aspiration, or by short-term follow-up mammography to provide insight to radiolog...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(03)00382-9
更新日期:2003-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to identify radiology topics considered essential by residency program directors who will be working with our graduates. Secondary goals were to survey their satisfaction with incoming residents' radiology knowledge, inquire if radiology training was provided in th...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2012.12.003
更新日期:2013-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Pulmonary atelectasis presumably promotes and facilitates lung injury. However, data are limited on its direct and remote relation to inflammation. We aimed to assess regional 2-deoxy-2-[18F]-fluoro-D-glucose (18F-FDG) kinetics representative of inflammation in atelectatic and normally aerated ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2019.12.022
更新日期:2020-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the correlations of tracheal volume and collapsibility on inspiratory and end-expiratory computed tomography (CT) with lung volume and with lung function in smokers. MATERIALS AND METHODS:The institutional review board approved this study at each institution. 85 smokers (mean age 6...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2010.11.005
更新日期:2011-03-01 00:00:00
abstract::Successful research results from the combination of multiple elements, including an appropriate research question, study design, research method, statistical analysis, and interpretation of results. One element of research that is easy to overlook is proper data collection and preparation for analysis. If data collect...
journal_title:Academic radiology
pub_type: 杂志文章,评审
doi:10.1016/j.acra.2015.08.024
更新日期:2015-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study aimed to test high temporal resolution dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for different zones of the prostate and evaluate its performance in the diagnosis of prostate cancer (PCa). Determine whether the addition of ultrafast DCE-MRI improves the perform...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2017.10.004
更新日期:2018-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To describe the application of time maximum intensity projection CTA (t-MIP CTA) in acute ischemic stroke and compare t-MIP CTA and single-phase CTA (sCTA) in assessing collateral circulation and predicting prognosis. MATERIALS AND METHODS:Twenty-nine acute ischemic stroke patients who underwe...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2019.06.013
更新日期:2020-05-01 00:00:00