Full field digital mammography and breast density: comparison of calibrated and noncalibrated measurements.

Abstract:

RATIONALE AND OBJECTIVES:Mammographic breast density is an important and widely accepted risk factor for breast cancer. A statement about breast density in the mammographic report is becoming a requirement in many States. However, there is significant inter-observer variation between radiologists in their interpretation of breast density. A properly designed automated system could provide benefits in maintaining consistency and reproducibility. We have developed a new automated and calibrated measure of breast density using full field digital mammography (FFDM). This new measure assesses spatial variation within a mammogram and produced significant associations with breast cancer in a small study. The costs of this automation are delays from advanced image and data analyses before the study can be processed. We evaluated this new calibrated variation measure using a larger dataset than previously. We also explored the possibility of developing an automated measure from unprocessed (raw data) mammograms as an approximation for this calibrated breast density measure. MATERIALS AND METHODS:A case-control study comprised of 160 cases and 160 controls matched by age, screening history, and hormone replacement therapy was used to compare the calibrated variation measure of breast density with three variants of a noncalibrated measure of spatial variation. The operator-assisted percentage of breast density measure (PD) was used as a standard reference for comparison. Odds ratio (OR) quartile analysis was used to compare these measures. Linear regression analysis was applied to assess the calibration's impact on the raw pixel distribution. RESULTS:All breast density measures showed significant breast cancer associations. The calibrated spatial variation measure produced the strongest associations (OR: 1.0 [ref.], 4.6, 4.3, 7.4). The associations for PD were diminished in comparison (OR: 1.0 [ref.], 2.7, 2.9, 5.2). Two additional non-calibrated measures restricted in region size also showed significant associations (OR: 1.0 [ref.], 2.9, 4.4, 5.4), and (OR: 1.0 [ref.], 3.5, 3.1, 4.9). Regression analyses indicated the raw image mean is influenced by the calibration more so than its standard deviation. CONCLUSION:Breast density measures can be automated. The associated calibration produced risk information not retrievable from the raw data representation. Although the calibrated measure produced the stronger association, the non-calibrated measures may offer an alternative to PD and other operator based methods after further evaluation, because they can be implemented automatically with a simple processing algorithm.

journal_name

Acad Radiol

journal_title

Academic radiology

authors

Heine JJ,Fowler EE,Flowers CI

doi

10.1016/j.acra.2011.07.011

subject

Has Abstract

pub_date

2011-11-01 00:00:00

pages

1430-6

issue

11

eissn

1076-6332

issn

1878-4046

pii

S1076-6332(11)00354-0

journal_volume

18

pub_type

杂志文章
  • Preliminary experience with contrast-enhanced MR angiography in patients with end-stage renal failure.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to evaluate our preliminary experience with routine contrast-enhanced magnetic resonance angiography (CE-MRA) of the lower limb arteries in patients with end-stage renal failure. MATERIALS AND METHODS:A retrospective analysis was performed on clinical, physiologic...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.01.021

    authors: Perriss R,Løkkegaard H,Løgager V,Chabanova E,Thomsen HS

    更新日期:2005-05-01 00:00:00

  • Impact of COVID-19 Workflow Changes on Patient Throughput at Outpatient Imaging Centers.

    abstract:RATIONALE AND OBJECTIVES:To determine the impact of COVID-19 workflow changes on patient throughput at the outpatient imaging facilities of a large healthcare system in New York City. MATERIALS AND METHODS:COVID-19 workflow changes to permit social distancing and patient and staff safety included screening at the time...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.12.016

    authors: Chang G,Doshi A,Chandarana H,Recht M

    更新日期:2021-01-04 00:00:00

  • LSU Health Sciences Center New Orleans Department of Radiology: effects of Hurricane Katrina.

    abstract::This case study chronicles the impact of Hurricane Katrina on the Department of Radiology at the Louisiana State University School of Medicine in New Orleans and the department's subsequent efforts to recover and re-dedicate itself to providing quality patient care and resident education. Hurricane Katrina damaged the...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.01.016

    authors: Duggal A,Letourneau JG,Bok LR

    更新日期:2009-05-01 00:00:00

  • Prognostic Value of Atherosclerosis Progression for Prediction of Cardiovascular Events in Patients with Nonobstructive Coronary Artery Disease.

    abstract:RATIONALE AND OBJECTIVES:Coronary CT angiography (CCTA) is a noninvasive reliable cardiovascular imaging technology to assess coronary atherosclerosis progression. However, there is limited data available to investigate the relationship between the atherosclerosis progression and cardiovascular events in patients with ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.06.038

    authors: Gu H,Lu B,Gao Y,Hou Z,Yang S,Yuan X,Zhao S,Wang X

    更新日期:2020-10-22 00:00:00

  • Histological Subtypes Classification of Lung Cancers on CT Images Using 3D Deep Learning and Radiomics.

    abstract:RATIONALE AND OBJECTIVES:Histological subtypes of lung cancers are critical for clinical treatment decision. In this study, we attempt to use 3D deep learning and radiomics methods to automatically distinguish lung adenocarcinomas (ADC), squamous cell carcinomas (SCC), and small cell lung cancers (SCLC) respectively on...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.06.010

    authors: Guo Y,Song Q,Jiang M,Guo Y,Xu P,Zhang Y,Fu CC,Fang Q,Zeng M,Yao X

    更新日期:2020-07-01 00:00:00

  • Establishment and results of a magnetic resonance quality assurance program for the pediatric brain tumor consortium.

    abstract:RATIONALE AND OBJECTIVES:Magnetic resonance (MR) imaging is used to assess brain tumor response to therapies, and a MR quality assurance (QA) program is necessary for multicenter clinical trials employing imaging. This study was performed to determine overall variability of quantitative imaging metrics measured with th...

    journal_title:Academic radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.acra.2008.04.004

    authors: Mulkern RV,Forbes P,Dewey K,Osganian S,Clark M,Wong S,Ramamurthy U,Kun L,Poussaint TY

    更新日期:2008-09-01 00:00:00

  • Moving Radiology Workflow to the Electronic Health Record: Quantitative and Qualitative Experience From a Large Academic Medical Center.

    abstract:RATIONALE AND OBJECTIVES:To objectively and subjectively evaluate a large, academic radiology department's transition to electronic health record (EHR) centered workflow. MATERIALS AND METHODS:Multiple metrics were compared from before and after the move to EHR-driven workflow. Examination ordering and reading priorit...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.02.006

    authors: Wildman-Tobriner B,Thorpe MP,Said N,Ehieli WL,Roth CJ,Jaffe TA

    更新日期:2020-02-01 00:00:00

  • Automated segmentation of the liver from 3D CT images using probabilistic atlas and multilevel statistical shape model.

    abstract:RATIONALE AND OBJECTIVES:An atlas-based automated liver segmentation method from three-dimensional computed tomographic (3D CT) images has been developed. The method uses two types of atlases, a probabilistic atlas (PA) and a statistical shape model (SSM). MATERIALS AND METHODS:Voxel-based segmentation with a PA is fi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2008.07.008

    authors: Okada T,Shimada R,Hori M,Nakamoto M,Chen YW,Nakamura H,Sato Y

    更新日期:2008-11-01 00:00:00

  • 68Ga-PSMA PET/CT in Patients with Rising Prostatic-Specific Antigen After Definitive Treatment of Prostate Cancer: Detection Efficacy and Diagnostic accuracy.

    abstract:RATIONALE AND OBJECTIVES:68Ga-prostate-specific membrane antigen-11 (68Ga-PSMA-11) is a recently developed positron emission tomography (PET) tracer that can detect prostate cancer (PC) relapses and metastases with high contrast resolution. The aim of this study was to assess the detection efficacy and diagnostic accur...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2018.05.020

    authors: Hamed MAG,Basha MAA,Ahmed H,Obaya AA,Afifi AHM,Abdelbary EH

    更新日期:2019-04-01 00:00:00

  • Rates of disagreement in imaging interpretation in a group of community hospitals.

    abstract:RATIONALE AND OBJECTIVES:Prospective studies of radiologists' interpretations of selected radiographs reported 20-40 years ago indicated error rates of 30% and higher. The authors retrospectively evaluated the interpretations of groups of radiologists and determined a range of rates of disagreement in interpretation. Q...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(98)80277-8

    authors: Siegle RL,Baram EM,Reuter SR,Clarke EA,Lancaster JL,McMahan CA

    更新日期:1998-03-01 00:00:00

  • Influence of using manual or automatic breast density information in a mass detection CAD system.

    abstract:RATIONALE AND OBJECTIVES:The goal of this article is to analyze and compare the performance of a developed mass computer-aided detection (CAD) system that takes breast density information into account when using manual or automatic breast density annotations in the training step. The advantages of considering this brea...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.04.013

    authors: Oliver A,Lladó X,Freixenet J,Martí R,Pérez E,Pont J,Zwiggelaar R

    更新日期:2010-07-01 00:00:00

  • How good is the ACR accreditation phantom for assessing image quality in digital mammography?

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to evaluate the American College of Radiology (ACR) accreditation phantom for assessing image quality in digital mammography. MATERIALS AND METHODS:Digital images were obtained of an ACR accreditation phantom at varying mAs (constant kVp) and varying kVp (constant...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80345-8

    authors: Huda W,Sajewicz AM,Ogden KM,Scalzetti EM,Dance DR

    更新日期:2002-07-01 00:00:00

  • Comparison between acetazolamide challenge and 10% carbon dioxide challenge perfusion CT in rat C6 glioma.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to investigate the effect of perfusion computed tomography (PCT) with acetazolamide (ACZ) challenge and compare it to 10% carbon dioxide (CO(2)) challenge in rat C6 glioma. MATERIALS AND METHODS:PCT was performed on 32 rats, including 20 with orthotopically implanted ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.09.017

    authors: Lu N,Di Y,Feng XY,Qiang JW,Zhang JW,Wang YG,Guo QY

    更新日期:2012-02-01 00:00:00

  • Role of endothelium-derived nitric oxide-endothelin balance in contrast medium-induced acute renal vasoconstriction in dogs.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluated the involvement of nitric oxide and endothelin in radiographic contrast medium-induced changes in renal hemodynamics. METHODS:Eleven anesthetized healthy dogs were each studied during three periods. Thirty minutes before the first, second, and third periods, the dogs rece...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(97)80115-8

    authors: Bagnis C,Idee JM,Dubois M,Jacquiaud C,Maistre G,Jacobs C,Deray G

    更新日期:1997-05-01 00:00:00

  • Reliability of MR Quantification of Rotator Cuff Muscle Fatty Degeneration Using a 2-point Dixon Technique in Comparison with the Goutallier Classification: Validation Study by Multiple Readers.

    abstract:RATIONALE AND OBJECTIVES:Presurgical assessment of fatty degeneration is important in the management of patients with rotator cuff tears. The Goutallier classification is widely accepted as a qualitative scoring system, although it is highly observer-dependent and has poor reproducibility. The objective of this study w...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.03.026

    authors: Horiuchi S,Nozaki T,Tasaki A,Yamakawa A,Kaneko Y,Hara T,Yoshioka H

    更新日期:2017-11-01 00:00:00

  • Impact of the Addition of Digital Breast Tomosynthesis (DBT) to Standard 2D Digital Screening Mammography on the Rates of Patient Recall, Cancer Detection, and Recommendations for Short-term Follow-up.

    abstract:RATIONALE AND OBJECTIVES:The addition of digital breast tomosynthesis (DBT) to digital screening mammography (DM) has been shown to decrease recall rates and improve cancer detection rates, but there is a lack of data regarding the impact of DBT on rates of short-term follow-up. We assessed possible changes in performa...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.10.001

    authors: Powell JL,Hawley JR,Lipari AM,Yildiz VO,Erdal BS,Carkaci S

    更新日期:2017-03-01 00:00:00

  • A Review of Supplemental Screening Ultrasound for Breast Cancer: Certain Populations of Women with Dense Breast Tissue May Benefit.

    abstract::Breast density has been shown to be a strong, independent risk factor for breast cancer. Unfortunately, mammography is less accurate on dense breast tissue compared to fattier breast tissue. Multiple studies suggest a solution to this by demonstrating the ability of supplemental screening ultrasound to detect addition...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2016.05.017

    authors: Burkett BJ,Hanemann CW

    更新日期:2016-12-01 00:00:00

  • High-resolution black-blood MRI of the carotid vessel wall using phased-array coils at 1.5 and 3 Tesla.

    abstract:RATIONALE AND OBJECTIVES:The aim of this report is to investigate the magnetic field dependence of the signal-to-noise ratio (SNR) for carotid vessel wall magnetic resonance imaging using phased-array (PA) surface coils by comparing images obtained at 1.5 and 3 Tesla (T) and determine the extent to which the improved S...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.08.009

    authors: Anumula S,Song HK,Wright AC,Wehrli FW

    更新日期:2005-12-01 00:00:00

  • Long residence time of ultrasound microbubbles targeted to integrin in murine tumor model.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to evaluate the intratumoral residence time of microbubbles (MBs) targeted to alpha(v)beta(3) integrin expressed in the endothelial cells of mice during the process of tumor angiogenesis. MATERIALS AND METHODS:For the preparation of MBs, decafluorobutane gas was sonic...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.07.017

    authors: Jun HY,Park SH,Kim HS,Yoon KH

    更新日期:2010-01-01 00:00:00

  • Characteristics and pitfalls of contrast-enhanced, T1-weighted magnetization transfer images of the brain.

    abstract:RATIONALE AND OBJECTIVES:This study was undertaken to clarify the difference in signal pattern on contrast material-enhanced T1-weighted magnetic resonance (MR) magnetization transfer (MT) images between enhancing and nonenhancing lesions in various intracranial diseases and to determine the necessity of nonenhanced MT...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(00)80116-6

    authors: Higano S,Shrier DA,Numaguchi Y,Shibata DK,Kwok E

    更新日期:2000-03-01 00:00:00

  • Reproducibility and repeatability of volumetric measurements for olfactory bulb volumetry: which method is appropriate? An update using 3 Tesla MRI.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to compare different sequences for olfactory bulb volumetry using 3-T magnetic resonance imaging, evaluating reproducibility, repeatability, and systematic biases. MATERIALS AND METHODS:Twenty-two volunteers underwent 3-T magnetic resonance imaging of the frontal skul...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.02.018

    authors: Burmeister HP,Baltzer PA,Möslein C,Bitter T,Gudziol H,Dietzel M,Guntinas-Lichius O,Kaiser WA

    更新日期:2011-07-01 00:00:00

  • Metastases to the breast from non-mammary malignancies: primary tumors, prevalence, clinical signs, and radiological features.

    abstract:RATIONALE AND OBJECTIVES:Most secondary intramammary tumors occur as metastatic involvement from the contralateral breast. Breast metastases (BM) from nonmammary malignancies are very rare. The aims of this study were to estimate retrospectively the prevalence of BM from nonmammary malignancies and to describe their ra...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.12.009

    authors: Surov A,Fiedler E,Holzhausen HJ,Ruschke K,Schmoll HJ,Spielmann RP

    更新日期:2011-05-01 00:00:00

  • Reproducibility of mRECIST in Measurement and Response Assessment for Hepatocellular Carcinoma Treated by Transarterial Chemoembolization.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the reproducibility of Modified Response Evaluation Criteria in Solid Tumors (mRECIST) for hepatocellular carcinoma (HCC) after transarterial chemoembolization (TACE) using multiphasic computed tomography. MATERIALS AND METHODS:The institutional review board approved this retrospec...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2018.02.013

    authors: Choi MH,Park GE,Oh SN,Park MY,Rha SE,Lee YJ,Jung SE,Choi JI

    更新日期:2018-11-01 00:00:00

  • Morphologic relationship among the corpus callosum, fornix, anterior commissure, and posterior commissure MRI-based variability study.

    abstract:RATIONALE AND OBJECTIVES:This study explores morphological relationships and structural variability of the corpus callosum (CC), fornix (Fo), anterior (AC), and posterior commissures (PC). MATERIALS AND METHODS:These structures are extracted automatically on the midsagittal plane. The CC and Fo are modeled using best-...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.06.018

    authors: Prakash KN,Nowinski WL

    更新日期:2006-01-01 00:00:00

  • Increased epicardial, pericardial, and subcutaneous adipose tissue is associated with the presence and severity of coronary artery calcium.

    abstract:RATIONALE AND OBJECTIVES:Epicardial adipose tissue (EAT), pericardial adipose tissue (PAT), and subcutaneous adipose tissue (SAT) are mediators of metabolic risk and may be involved in the pathogenesis of coronary artery disease. The aim of this study was to investigate the association of visceral and subcutaneous fat ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.08.017

    authors: Ahmadi N,Nabavi V,Yang E,Hajsadeghi F,Lakis M,Flores F,Zeb I,Bevinal M,Ebrahimi R,Budoff M

    更新日期:2010-12-01 00:00:00

  • Part I: preparing first-year radiology residents and assessing their readiness for on-call responsibilities.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study is to evaluate the effectiveness of an Emergency Radiology (ER) Core Curriculum training module and a Digital Imaging and Communications in Medicine (DICOM)-based interactive examination system to prepare first-year (postgraduate year 2 [PGY-2]) radiology residents and asse...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.02.057

    authors: Ganguli S,Pedrosa I,Yam CS,Appignani B,Siewert B,Kressel HY

    更新日期:2006-06-01 00:00:00

  • Comparison of diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low, intermediate, and high cardiovascular risk.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to compare the diagnostic accuracy of 64-slice computed tomographic coronary angiography (CTCA) in groups of patients with low, intermediate, and high risk for coronary artery disease (CAD) events. MATERIALS AND METHODS:The institutional review board approved this stu...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2007.12.008

    authors: Husmann L,Schepis T,Scheffel H,Gaemperli O,Leschka S,Valenta I,Koepfli P,Desbiolles L,Stolzmann P,Marincek B,Alkadhi H,Kaufmann PA

    更新日期:2008-04-01 00:00:00

  • Performance of Ultrafast DCE-MRI for Diagnosis of Prostate Cancer.

    abstract:RATIONALE AND OBJECTIVES:This study aimed to test high temporal resolution dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for different zones of the prostate and evaluate its performance in the diagnosis of prostate cancer (PCa). Determine whether the addition of ultrafast DCE-MRI improves the perform...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.10.004

    authors: Chatterjee A,He D,Fan X,Wang S,Szasz T,Yousuf A,Pineda F,Antic T,Mathew M,Karczmar GS,Oto A

    更新日期:2018-03-01 00:00:00

  • Clinical Outcomes of Patients with Porcelain Gallbladder Diagnosed on CT.

    abstract:PURPOSE:To evaluate diagnostic accuracy and clinical outcomes of patients with porcelain gallbladder (GB) diagnosed on CT. MATERIALS AND METHODS:In this IRB-approved, HIPAA-compliant study, consecutive patients with porcelain gallbladder reported on CT between December 1, 2000 and August 31, 2017 in a tertiary academi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.07.006

    authors: Appel E,Dommaraju S,Siewert B,Gonzalez RS,Camacho A,Park Y,Brook OR

    更新日期:2020-08-04 00:00:00

  • Stereotactic and sonographic large-core biopsy of nonpalpable breast lesions: results of the Radiologic Diagnostic Oncology Group V study.

    abstract:RATIONALE AND OBJECTIVES:To determine the diagnostic accuracy of stereotactically and sonographically guided core biopsy (CB) for the diagnosis of nonpalpable breast lesions. MATERIALS AND METHODS:Twenty-two institutions enrolled 2,403 women who underwent imaging-guided fine needle aspiration followed by imaging-guide...

    journal_title:Academic radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1016/s1076-6332(03)00510-5

    authors: Fajardo LL,Pisano ED,Caudry DJ,Gatsonis CA,Berg WA,Connolly J,Schnitt S,Page DL,McNeil BJ,Radiologist Investigators of the Radiologic Diagnostic Oncology Group V.

    更新日期:2004-03-01 00:00:00