Computerized delineation and analysis of costophrenic angles in digital chest radiographs.

Abstract:

RATIONALE AND OBJECTIVES:The authors developed a computerized method for delineating the costophrenic angles in digital posteroanterior chest radiographs to derive quantitative information that allows for detection of abnormal blunting of the costophrenic angle. MATERIALS AND METHODS:An automated lung-segmentation scheme was used, and small regions of interest were placed in the approximate position of the costophrenic angles in 600 clinical posteroanterior chest radiographs to define a subimage for further analysis. The diaphragmatic aspect of the costophrenic angle was delineated based on column-wise contrast information, and the costal aspect was delineated based on row-wise gray-level maxima. The angle formed by the convergence of these two aspects provided the basis for assessing abnormality. Curve fitting was then performed on these segments to form a continuous costophrenic angle delineation. RESULTS:The computer-determined angles for 1,166 hemithoraces were compared with independent diagnostic assessments by a radiologist. An encouraging level of agreement was found between these two measurements, with the area under the receiver operating characteristic curve attaining a value of 0.83. CONCLUSION:This delineation method enhances the automated lung-segmentation scheme. Quantitative information obtained from the costophrenic angles can be used for automatic evaluation of the presence of costophrenic angle blunting, which may indicate the presence of pleural effusion.

journal_name

Acad Radiol

journal_title

Academic radiology

authors

Armato SG 3rd,Giger ML,MacMahon H

doi

10.1016/s1076-6332(98)80151-7

subject

Has Abstract

pub_date

1998-05-01 00:00:00

pages

329-35

issue

5

eissn

1076-6332

issn

1878-4046

journal_volume

5

pub_type

杂志文章
  • Comparison of image acquisition and radiologist interpretation times in a diagnostic mammography center.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine the acquisition and interpretation times of screen-film mammography and soft-copy digital mammography in a diagnostic mammography center. MATERIALS AND METHODS:The study was conducted in three phases for patients presenting for clinical diagnostic wor...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.04.018

    authors: Kuzmiak CM,Cole E,Zeng D,Kim E,Koomen M,Lee Y,Pavic D,Pisano ED

    更新日期:2010-09-01 00:00:00

  • Chest radiology case exchange program: a paradigm for resident teaching and independent resident learning.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to test the effectiveness of resident-prepared, independent learning cases in teaching residents chest radiology. MATERIALS AND METHODS:Three 2nd-year residents (one each from the University of Wisconsin, the Oregon Health Sciences University, and the University o...

    journal_title:Academic radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1016/s1076-6332(99)80059-2

    authors: Collins J,Blankenbaker DG,Albanese MA,Stack SP,Heiserman KK,Primack SL,Kazerooni EA

    更新日期:1999-01-01 00:00:00

  • The role of ultrasonography in the evaluation of abdominal fat: analysis of technical and methodological issues.

    abstract:RATIONALE AND OBJECTIVES:Ultrasonography (US) is becoming popular for the assessment of adiposity, but no one has studied this tool in the light of its potential limitations. Our purpose was to investigate the impact of technical conditions on the evaluation of abdominal fat by US. MATERIALS AND METHODS:Forty-five hea...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2013.07.009

    authors: Bazzocchi A,Filonzi G,Ponti F,Amadori M,Sassi C,Salizzoni E,Albisinni U,Battista G

    更新日期:2013-10-01 00:00:00

  • Liver perfusion imaging in patients with primary and metastatic liver malignancy: prospective comparison between 99mTc-MAA spect and dynamic CT perfusion.

    abstract:RATIONALE AND OBJECTIVES:To prospectively analyze the correlation between parameters of liver perfusion from technetium99m-macroaggregates of albumin (99mTc-MAA) single photon emission computed tomography (SPECT) with those obtained from dynamic CT perfusion in patients with primary or metastatic liver malignancy. MAT...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.12.015

    authors: Reiner CS,Goetti R,Burger IA,Fischer MA,Frauenfelder T,Knuth A,Pfammatter T,Schaefer N,Alkadhi H

    更新日期:2012-05-01 00:00:00

  • Automated segmentation of the liver from 3D CT images using probabilistic atlas and multilevel statistical shape model.

    abstract:RATIONALE AND OBJECTIVES:An atlas-based automated liver segmentation method from three-dimensional computed tomographic (3D CT) images has been developed. The method uses two types of atlases, a probabilistic atlas (PA) and a statistical shape model (SSM). MATERIALS AND METHODS:Voxel-based segmentation with a PA is fi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2008.07.008

    authors: Okada T,Shimada R,Hori M,Nakamoto M,Chen YW,Nakamura H,Sato Y

    更新日期:2008-11-01 00:00:00

  • Triple rule-out CT in patients with suspicion of acute pulmonary embolism: findings and accuracy.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to prospectively investigate the diagnostic value of triple rule-out computed tomography (CT) in patients suspected of having acute pulmonary embolism (PE). MATERIALS AND METHODS:A total of 125 patients with suspicion of PE, of whom 14 patients had the additional clin...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.01.014

    authors: Schertler T,Frauenfelder T,Stolzmann P,Scheffel H,Desbiolles L,Marincek B,Kaplan V,Kucher N,Alkadhi H

    更新日期:2009-06-01 00:00:00

  • When and why might a computer-aided detection (CAD) system interfere with visual search? An eye-tracking study.

    abstract:RATIONAL AND OBJECTIVES:Computer-aided detection (CAD) systems are intended to improve performance. This study investigates how CAD might actually interfere with a visual search task. This is a laboratory study with implications for clinical use of CAD. METHODS:Forty-seven naive observers in two studies were asked to ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.05.013

    authors: Drew T,Cunningham C,Wolfe JM

    更新日期:2012-10-01 00:00:00

  • Establishment and results of a magnetic resonance quality assurance program for the pediatric brain tumor consortium.

    abstract:RATIONALE AND OBJECTIVES:Magnetic resonance (MR) imaging is used to assess brain tumor response to therapies, and a MR quality assurance (QA) program is necessary for multicenter clinical trials employing imaging. This study was performed to determine overall variability of quantitative imaging metrics measured with th...

    journal_title:Academic radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.acra.2008.04.004

    authors: Mulkern RV,Forbes P,Dewey K,Osganian S,Clark M,Wong S,Ramamurthy U,Kun L,Poussaint TY

    更新日期:2008-09-01 00:00:00

  • Videomanometry of the pharynx in dysphagic patients with a posterior cricopharyngeal indentation.

    abstract:RATIONALE AND OBJECTIVES:Patients with a posterior indentation in the pharyngoesophageal segment (PES) are generally considered to have an abnormality of the cricopharyngeal muscle (CPM). In this study we determined the actual width of the PES and the pressure circumstances during swallowing within the pharynx and PES ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(05)80123-0

    authors: Olsson R,Ekberg O

    更新日期:1995-07-01 00:00:00

  • A preliminary report on the role of spatial frequency analysis in the perception of breast cancers missed at mammography screening.

    abstract:RATIONALE AND OBJECTIVES:Because several factors are involved in cancer detection, a malignant lesion that is visible on a mammogram will not necessarily be reported by the radiologist reading the case. Indeed, a significant fraction of screening-detected cancers are visible in retrospect, and were perceived by the rad...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.04.015

    authors: Mello-Thoms C,Chapman B

    更新日期:2004-08-01 00:00:00

  • Variability in Individual Radiologist BI-RADS 3 Usage at a Large Academic Center: What's the Cause and What Should We Do About It?

    abstract:RATIONALE AND OBJECTIVES:Although the breast imaging reporting and data system (BI-RADS) lists specific criteria for designating a lesion as BI-RADS category 3 (probably benign), there are no target benchmarks for BI-RADS 3 usage rates. This study investigates the variability of BI-RADS 3 rates among a group of academi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2018.09.002

    authors: Ambinder EB,Mullen LA,Falomo E,Myers K,Hung J,Lee B,Harvey SC

    更新日期:2019-07-01 00:00:00

  • Reproducibility and repeatability of volumetric measurements for olfactory bulb volumetry: which method is appropriate? An update using 3 Tesla MRI.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to compare different sequences for olfactory bulb volumetry using 3-T magnetic resonance imaging, evaluating reproducibility, repeatability, and systematic biases. MATERIALS AND METHODS:Twenty-two volunteers underwent 3-T magnetic resonance imaging of the frontal skul...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.02.018

    authors: Burmeister HP,Baltzer PA,Möslein C,Bitter T,Gudziol H,Dietzel M,Guntinas-Lichius O,Kaiser WA

    更新日期:2011-07-01 00:00:00

  • Liver Imaging Reporting and Data System:: Substantial Discordance Between CT and MR for Imaging Classification of Hepatic Nodules.

    abstract:RATIONALE AND OBJECTIVES:The Liver Imaging Reporting and Data System (LI-RADS) is a newly developed nomogram for standardizing the performance and interpretation of liver imaging. However, it is unclear which imaging technique is optimal to exactly define LI-RADS scale. This study aims to determine the concordance of c...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2015.11.002

    authors: Zhang YD,Zhu FP,Xu X,Wang Q,Wu CJ,Liu XS,Shi HB

    更新日期:2016-03-01 00:00:00

  • Emotional Wellness of Current Musculoskeletal Radiology Fellows.

    abstract:RATIONALE AND OBJECTIVES:Burnout is a psychological syndrome composed of emotional exhaustion, depersonalization, and sense of lack of personal accomplishment, as a result of prolonged occupational stress. The purpose of our study was to determine the prevalence of burnout among current musculoskeletal radiology fellow...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.12.024

    authors: Porrino J,Mulcahy MJ,Mulcahy H,Relyea-Chew A,Chew FS

    更新日期:2017-06-01 00:00:00

  • Preoperative MRI improves prediction of extensive occult axillary lymph node metastases in breast cancer patients with a positive sentinel lymph node biopsy.

    abstract:RATIONALE AND OBJECTIVES:To test the ability of quantitative measures from preoperative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to predict, independently and/or with the Katz pathologic nomogram, which breast cancer patients with a positive sentinel lymph node biopsy will have four or more positi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2013.10.001

    authors: Loiselle C,Eby PR,Kim JN,Calhoun KE,Allison KH,Gadi VK,Peacock S,Storer BE,Mankoff DA,Partridge SC,Lehman CD

    更新日期:2014-01-01 00:00:00

  • Beyond Correlations, Sensitivities, and Specificities: A Roadmap for Demonstrating Utility of Advanced Imaging in Oncology Treatment and Clinical Trial Design.

    abstract::Despite the widespread belief that advanced imaging should be very helpful in guiding oncology treatment decision and improving efficiency and success rates in treatment clinical trials, its acceptance has been slow. Part of this is likely attributable to gaps in study design and statistical methodology for these imag...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2017.03.002

    authors: Huang EP,Lin FI,Shankar LK

    更新日期:2017-08-01 00:00:00

  • On the Potential Role of MRI Biomarkers of COPD to Guide Bronchoscopic Lung Volume Reduction.

    abstract:RATIONALE AND OBJECTIVES:In patients with severe emphysema and poor quality of life, bronchoscopic lung volume reduction (BLVR) may be considered and guided based on lobar emphysema severity. In particular, x-ray computed tomography (CT) emphysema measurements are used to identify the most diseased and the second-most ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.08.010

    authors: Adams CJ,Capaldi DPI,Di Cesare R,McCormack DG,Parraga G,Canadian Respiratory Research Network.

    更新日期:2018-02-01 00:00:00

  • In vivo MR thermometry of frozen tissue using R2* and signal intensity.

    abstract::Cryoablation is one of several minimally invasive treatments that may be suitable for a targeted treatment of prostate cancer. Because efficacy is improved when a sufficiently cold end temperature is reached, the purpose of this work was to demonstrate an image-based thermometry method that could provide temperature m...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.06.006

    authors: Wansapura JP,Daniel BL,Vigen KK,Butts K

    更新日期:2005-09-01 00:00:00

  • The value of magnetic resonance imaging in the detection of prostate cancer in patients with previous negative biopsies and elevated prostate-specific antigen levels: a meta-analysis.

    abstract:RATIONALE AND OBJECTIVES:To assess the diagnostic performance of magnetic resonance imaging (MRI) for targeting prostate cancer in patients with previous negative biopsies and elevated prostate-specific antigen (PSA) levels. MATERIALS AND METHODS:Pubmed, Scopus, and Cochrane Library databases were searched to identify...

    journal_title:Academic radiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.acra.2014.01.004

    authors: Zhang ZX,Yang J,Zhang CZ,Li KA,Quan QM,Wang XF,Wang H,Zhang GX

    更新日期:2014-05-01 00:00:00

  • A randomized trial of prophylactic acetylcysteine and theophylline compared with placebo for the prevention of renal tubular vacuolization in rats after iohexol administration.

    abstract:RATIONALE AND OBJECTIVES:Renal tubular vacuolization (RTV), which has been shown to occur after the use of iodinated contrast material, may be one of the earliest signs of contrast medium-induced renal injury. In this study, the authors tested a method for preventing RTV with the administration of acetylcysteine, theop...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80061-2

    authors: Emch TM,Haller NA

    更新日期:2003-05-01 00:00:00

  • Stable polymeric micelles: lymphangiographic contrast media for gamma scintigraphy and magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Amphiphilic biocompatible polyoxyethylene (PEO)-based polymers form particles (micelles) that are 10-50 nm in diameter. In the current research, we successfully incorporated amphiphilic indium-111 (111In) and gadolinium chelates into these particles and used them as particulate contrast media i...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(96)80448-x

    authors: Trubetskoy VS,Frank-Kamenetsky MD,Whiteman KR,Wolf GL,Torchilin VP

    更新日期:1996-03-01 00:00:00

  • A probabilistic model for the MRMC method, part 1: theoretical development.

    abstract:RATIONALE AND OBJECTIVES:Current approaches to receiver operating characteristic (ROC) analysis use the MRMC (multiple-reader, multiple-case) paradigm in which several readers read each case and their ratings (or scores) are used to construct an estimate of the area under the ROC curve or some other ROC-related paramet...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.07.016

    authors: Clarkson E,Kupinski MA,Barrett HH

    更新日期:2006-11-01 00:00:00

  • T1-weighted MRI imaging features of pathologically proven non-pedal osteomyelitis.

    abstract:RATIONALE AND OBJECTIVES:The objective of our study was to determine if the T1-weighted magnetic resonance imaging (MRI) features associated with diabetic pedal osteomyelitis are present in histopathologically proven cases of non-pedal osteomyelitis. MATERIALS AND METHODS:Seventy-five patients with a histopathological...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.07.015

    authors: Howe BM,Wenger DE,Mandrekar J,Collins MS

    更新日期:2013-01-01 00:00:00

  • Positive Predictive Value of Mammographic Lymphography in the Evaluation of Patients with Breast Cancer: A Preliminary Study.

    abstract:RATIONALE AND OBJECTIVES:The study aimed to investigate the positive predictive value (PPV) of mammographic lymphography (MLG) for assessing malignant breast disease and lymphatic metastasis in patients in a typical clinical setting. MATERIALS AND METHODS:Patients who underwent mammography with Breast Imaging Reportin...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.05.001

    authors: Zhang K,Lu Q,Hua J,Xu J,Wu G

    更新日期:2016-10-01 00:00:00

  • Three-dimensional human airway segmentation methods for clinical virtual bronchoscopy.

    abstract:RATIONALE AND OBJECTIVES:The segmentation of airways from CT images is a critical first step for numerous virtual bronchoscopic (VB) applications. Automatic or semiautomatic methods are necessary, since manual segmentation is prohibitively time consuming. The methods must be robust and operate within a reasonable time ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80517-2

    authors: Kiraly AP,Higgins WE,McLennan G,Hoffman EA,Reinhardt JM

    更新日期:2002-10-01 00:00:00

  • Three-dimensional isotropic wavelets for post-acquisitional extraction of latent images of atherosclerotic plaque components from micro-computed tomography of human coronary arteries.

    abstract:RATIONALE AND OBJECTIVES:The capability of wavelet transforms to separate signals into frequency bands is the basis for its use in image compression and storage, data management and transmission, and, recently, extraction of latent images of tissue components from noisy medical images. Analysis of temporal variations o...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2007.06.018

    authors: Gertz SD,Bodmann BG,Vela D,Papadakis M,Aboshady I,Cherukuri P,Alexander S,Kouri DJ,Baid S,Gittens AA,Gladish GW,Conyers JL,Cody DD,Gavish L,Mazraeshahi RM,Wilner WT,Frazier L,Madjid M,Zarrabi A,Lukovenkov S,Ahmed

    更新日期:2007-12-01 00:00:00

  • Nonclinical factors associated with primary care physicians' ordering patterns of magnetic resonance imaging/computed tomography for headache.

    abstract:RATIONALE AND OBJECTIVES:The purpose of ordering an imaging test for headache, which is one of the most common reasons for patient consultation with a primary care physician (PCP), include medical indications as well as patient anxiety and medico-legal concerns. The impact of nonclinical factors on PCPs' ordering patte...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.03.050

    authors: Couchman GR,Forjuoh SN,Rajab MH,Phillips CD,Yu J

    更新日期:2004-07-01 00:00:00

  • CT-guided Drainage of Deep Pelvic Abscesses via a Percutaneous Presacral Space Approach: A Clinical Report and Review of the Literature.

    abstract:RATIONALE AND OBJECTIVES:Some deep pelvic abscesses are not accessible through anterior or lateral approaches because of the presence of organs and structures. The objective of this study was to assess the feasibility, safety, tolerability, and efficacy of a percutaneous presacral space approach by reviewing our clinic...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2016.06.009

    authors: Peng T,Dong L,Zhu Z,Cui J,Li Q,Li X,Wu H,Wang C,Yang Z

    更新日期:2016-12-01 00:00:00

  • Multi-reader ROC studies with split-plot designs: a comparison of statistical methods.

    abstract:RATIONALE AND OBJECTIVES:Multireader imaging trials often use a factorial design, in which study patients undergo testing with all imaging modalities and readers interpret the results of all tests for all patients. A drawback of this design is the large number of interpretations required of each reader. Split-plot desi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.09.012

    authors: Obuchowski NA,Gallas BD,Hillis SL

    更新日期:2012-12-01 00:00:00

  • Image Quality of Virtual Monochromatic Reconstructions of Noncontrast CT on a Dual-Source CT Scanner in Adult Patients.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the image quality of virtual monochromatic images (VMI) reconstructed from dual-energy dual-source noncontrast head CT with different reconstruction kernels. MATERIALS AND METHODS:Twenty-five consecutive adult patients underwent noncontrast dual-energy CT. VMI were retrospectively ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.05.038

    authors: van Ommen F,Kauw F,Bennink E,Heit JJ,Wolman DN,Dankbaar JW,de Jong HWAM,Wintermark M

    更新日期:2020-06-30 00:00:00