Abstract:
:In galactosemia, prevention of mental retardation depends on early recognition of the disorder and institution of dietary restriction of galactose. We describe an automated fluorometric micromethod for galactose in whole blood spotted on filter paper. Galactose is oxidized by galactose oxidase to D-galacto-hexadialdose and H2O2 and measured as the highly fluorescent condensation product of homovanillic acid formed when H2O2 is acted upon by horseradish peroxidase. The procedure is 10-fold more sensitive than colorimetric procedures for galactose and is not hampered by the nonspecific fluorescence from endogenous NADPH that is encountered in methods in which galactose dehydrogenase is used. At a sampling rate of 40/h with a sample-to-wash ratio of 1/2, carryover is negligible, reproducibility is excellent, and 80% of steady state is achieved. Analytical recovery of added galactose was 95%. The method has the requisite sensitivity and accuracy for quantification of galactosemia and galactosuria in milkfed newborn infants and genetic evaluation of families of patients.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Mason GA,Summer GK,Dutton HH,Schwaner RC Jrsubject
Has Abstractpub_date
1977-06-01 00:00:00pages
971-4issue
6eissn
0009-9147issn
1530-8561journal_volume
23pub_type
杂志文章abstract:BACKGROUND:Altered germline expression of genes may represent a powerful marker of genetic or epigenetic predisposition to cancer or other diseases. METHODS:We developed and validated a method of nonfluorescent primer extension that uses a single dideoxynucleotide and denaturing HPLC (DHPLC) to analyze the relative al...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2009.126300
更新日期:2009-09-01 00:00:00
abstract:BACKGROUND:Previous studies have shown a single linear relationship between mean plasma glucose (MPG) and hemoglobin A(1c) (HbA(1c)). We examined the relationship in different treatment groups of patients with type 1 diabetes participating in the Diabetes Control and Complications Trial (DCCT). METHODS:Seven-point glu...
journal_title:Clinical chemistry
pub_type: 杂志文章,随机对照试验
doi:10.1373/clinchem.2006.079756
更新日期:2007-05-01 00:00:00
abstract::Antiserum performance in a nephelometric system can be characterized by parameters derived from measuring reaction rates. The characterization process is derived from a series of dose-response curves (elicited nephelometric response vs antigen concentration) generated from various dilutions of the antiserum being test...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-11-01 00:00:00
abstract::The historical development of a charitable children's hospital and the evolution of its clinical laboratory are presented. With the appearance of practical quantitative blood chemistry tests in the period between the two World Wars, applications to pediatrics were hampered by the need for ultramicro procedures then un...
journal_title:Clinical chemistry
pub_type: 历史文章,杂志文章
doi:
更新日期:2000-07-01 00:00:00
abstract::We describe an automated enzymatic procedure for quantifying creatine in erythrocytes. In this assay, after sample clean-up, creatine kinase (CK; EC 2.7.3.2) and pyruvate kinase (EC 2.1.7.40) are used as auxiliary enzymes; lactate dehydrogenase (EC 1.1.1.27) is used in the indicator reaction. CK is also used as the st...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-02-01 00:00:00
abstract::A "high-performance" liquid-chromatographic procedure for 5-hydroxy-3-indoleacetic acid is described and compared with a colorimetric method in which 1-nitroso-2-naphthol is used. The analyte and an internal standard, p-nitrobenzoic acid, were extracted into diethyl ether from urine at pH 4.0 (acidified with HCl) to w...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-06-01 00:00:00
abstract:BACKGROUND:C-Reactive protein (CRP) has been shown to be a strong predictor of coronary heart disease (CHD) and is being considered in cardiovascular disease risk assessment. The number of normolipidemic individuals who are eligible for evaluation of CRP in overall CHD risk assessment is not known. METHODS:We analyzed...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2004.036004
更新日期:2004-09-01 00:00:00
abstract::Urinary excretion of orally administered lactulose is used as an index of intestinal permeability. We have developed a simple thin-layer chromatographic technique for measuring lactulose in urine, using silica gel 60 plates and a propanol-borate solvent system. Lactulose concentrations as low as 62.5 mg/L can be detec...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-07-01 00:00:00
abstract::We evaluated a dual-precipitation method for determining cholesterol in high-density lipoprotein (HDL) and its subfractions HDL2 and HDL3. After total HDL was isolated by precipitation of very-low-density (VLDL) and low-density (LDL) lipoproteins with polyethylene glycol (Mr 8000), HDL2 was isolated from total HDL by ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-11-01 00:00:00
abstract::We tested a new amylase reagent involving chromogenic substrates (Pantrak, Calbiochem-Behring) for precision, dynamic range, and susceptibility to potential interferences. Two p-nitrophenyl-alpha-maltaosides are used as substrates, which amylase cleaves to shorter-chain p-nitrophenyl maltaosides, the latter then yield...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-04-01 00:00:00
abstract:BACKGROUND:Quantitative, miniaturized nucleic acid assays and immunoassays can be developed with single microparticles, microfluorometric detection, and intrinsically fluorescent lanthanide chelates in a multiple assay format to decrease reagent consumption, cost, and assay time. We used recombinant Fab fragments to ca...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2000-11-01 00:00:00
abstract::The optimal measurement method and clinical application of the therapeutic drug monitoring of cyclosporine remain uncertain. At a workshop held at Hawk's Cay, FL, from January 14 to January 17, 1990, 57 scientists presented their latest research findings, either in formal papers or as discussants. Lively debate and di...
journal_title:Clinical chemistry
pub_type: 共识发展会议,杂志文章,评审
doi:
更新日期:1990-08-01 00:00:00
abstract:BACKGROUND:In recent years, a large number of studies have been published on the performance of glucose monitors. The quality of these reports is not known. METHODS:We searched the PubMed database for performance evaluations of handheld glucose monitors published from August 2002 to November 2006. Relevant articles we...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2006.083493
更新日期:2007-06-01 00:00:00
abstract::A highly sensitive two-site enzyme immunoassay (Capcellia) was developed to determine the concentration of CD4 and CD8 molecules expressed on the surface of human T lymphocytes. This assay, performed in one step (20 min), involves the specific immunocapture of T lymphocytes and reaction of the CD4 or CD8 molecules wit...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-01-01 00:00:00
abstract::We compared relative increases in creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) after reperfusion in myocardial infarction for four popular methods: electrophoresis, immunoinhibition, the "Magic Lite" (Ciba-Corning) system, and the Stratus (Dade). In a method comparison study, we confirmed that all four methods co...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-08-01 00:00:00
abstract::A competitive solid-phase fluoroenzymeimmunoassay has been developed for rapidly measuring 5 beta-pregnane-3 alpha, 20 alpha-diol-3 alpha-glucuronide (Pd-3G) directly in diluted specimens of pre-breakfast urine. The assay involves use of an antiserum to Pd-3G and enzyme-labeled antigen prepared by chemically linking g...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-02-01 00:00:00
abstract::We describe a sensitive method for the determination of vanadium in biological substances by atomic absorption spectroscopy. By using background correction and pyrolytically coated graphite tubes with flameless apparatus, this vanadium assay has a sensitivity of 65 pg and a detection limit of 30 pg, approximately sixf...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-01-01 00:00:00
abstract::The main developments in the "ligand assay" field in which I have been involved are traced. These include the original development of "first generation" competitive assays relying on radiolabeled analyte markers; the development of the first "second generation", noncompetitive (ultrasensitive) methods, which rely on t...
journal_title:Clinical chemistry
pub_type: 历史文章,杂志文章
doi:
更新日期:1998-09-01 00:00:00
abstract::We compared three current methods (immunoinhibition, "Isomune-CK" immunoprecipitation, and the Tandem-E CKMB II immunoenzymometric assay) for determination of creatine kinase (CK; EC 2.7.3.2) isoenzyme MB in serum. Although results inter-correlated well, the immunoinhibition assay gave higher activity values. Atypical...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-01-01 00:00:00
abstract:BACKGROUND:The aim of our present study was to establish new reference intervals for thyrotropin (TSH) and thyroid hormones based on National Academy of Clinical Biochemistry (NACB) criteria and regular thyroid ultrasonography. We also assessed the effect of potentially confounding factors to modulate the limits of the...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2004.047399
更新日期:2005-08-01 00:00:00
abstract::A new, highly sensitive immunoradiometric thyrotropin (TSH) assay involving solid-phase-coupled monoclonal antibodies (Boots-Celltech Sucrosep IRMA-TSH) has been evaluated in a wide variety of patients with thyroidal and nonthyroidal illnesses and the results compared with those obtained by conventional diagnostic TSH...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-03-01 00:00:00
abstract::Values of low-density lipoprotein (LDL) cholesterol (C) according to the Friedewald formula (Clin Chem 1972;18:499-502) were compared with those obtained by lipoprotein fractionation in 98 healthy subjects (control group), 135 specimens from patients with peripheral vascular and cerebrovascular disease (atheroscleroti...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-08-01 00:00:00
abstract::A three-parameter model for directly estimating imprecision profiles from replicated immunoassay results is compared with a six-parameter indirect profile model obtained by the usual method of combining error in the raw response measurements with the slope of the standard curve. Direct estimation is likely to be less ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-06-01 00:00:00
abstract:BACKGROUND:Endothelin-1 (ET-1), a potent vasoconstrictor, is difficult to measure because of its instability and its binding to receptors and plasma proteins. We report a rapid, robust way to indirectly quantify ET-1 release by measuring the C-terminal ET-1 precursor fragment (CT-proET-1) without an extraction step. M...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.065581
更新日期:2006-06-01 00:00:00
abstract:BACKGROUND:Gradient gel electrophoresis (GGE) and nuclear magnetic resonance (NMR) spectroscopy are both widely accepted methods for measuring LDL and HDL particle size. However, whether or not GGE- or NMR-measured LDL or HDL particle size predicts coronary heart disease (CHD) risk to a similar extent is currently unkn...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2009.140939
更新日期:2010-05-01 00:00:00
abstract::We evaluated the enzymic mechanism by which 3-keto butylidene-beta-2-chloro-4-nitrophenyl maltopentaoside (3KB-G5-CNP) serves as a substrate for serum pancreatic (p-) and salivary (s-) amylases. In aliquots of the reaction mixture, three kinds of beta-2-chloro-4-nitrophenyl oligosaccharides (glucose, maltoside, and ma...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-08-01 00:00:00
abstract:BACKGROUND:Adequate detection of designer steroids in the urine of athletes is still a challenge in doping control analysis and requires knowledge of steroid metabolism. In this study we investigated whether uPA(+/+)-SCID mice carrying functional primary human hepatocytes in their liver would provide a suitable alterna...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2008.119396
更新日期:2009-10-01 00:00:00
abstract::We describe a modified tantalum ribbon atomic absorption procedure for determining lead in undiluted whole blood. An instrumentation Laboratory (I.L.) Model 151 atomic absorption spectrophotometer equipped with an I.L. Model 355 Flameless Sampler was used. The Flameless Sampler was slightly modified to include three-c...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-07-01 00:00:00
abstract:BACKGROUND:A simple point-of-care method for measuring leukocyte counts in a doctor's office or emergency room could be of great importance. We developed a protocol for measuring cell count by disrupting the cell membrane and analyzing specific proteins within the cells and used it to analyze proteins from eosinophils ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.074021
更新日期:2007-02-01 00:00:00
abstract::We describe microplate methods for measurement of human urinary albumin (HUA) by competitive enzyme-linked immunosorbant assay (ELISA) and creatinine with a modified commercial enzymatic kit. Incorporation of substrate mixing into the competitive ELISA changes the dynamic absorbance-concentration response, greatly sim...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-07-01 00:00:00