Paediatric entrance doses from exposure index in computed radiography.

Abstract:

:Over the last two years we have evaluated paediatric patient doses in projection radiography derived from exposure level (EL) in computed radiography (CR) in a large university hospital. Entrance surface air kerma (ESAK) for 3501 paediatric examinations was calculated from the EL, which is a dose index parameter related to the light emitted by the phosphor-stimulable plate, archived in the Digital Imaging and Communications in Medicine (DICOM) header of the images and automatically transferred to a database using custom-built dedicated software. Typical mean thicknesses for several age bands of paediatric patients was estimated to calculate ESAK from the EL values, using results of experimental measurements with phantoms for the typical x-ray beam qualities used in paediatric examinations. Mean/median ESAK values (in microGy) for the age bands of <1 year, 1-5 years, 6-10 years and 11-15 years have been obtained for chest without a bucky: 51/41, 57/34, 91/54 and 122/109; chest with a bucky (for only the last three age bands): 114/87, 129/105 and 219/170; abdomen: 119/91, 291/225, 756/600 and 1960/1508 and pelvis: 65/48, 455/314, 943/707 and 2261/1595. Sample sizes of clinical images used for the (indirect) measurements were 1724 for chest without a bucky, 799 for chest with a bucky, 337 for abdomen and 641 for pelvis. The methodology we describe could be applicable to other centres using CR as an imaging modality for paediatrics. Presently, this method is the only practical approach to automatically extract parameters contained in the DICOM header, for the calculation of patient dose values for the CR modality.

journal_name

Phys Med Biol

authors

Vano E,Martinez D,Fernandez JM,Ordiales JM,Prieto C,Floriano A,Ten JI

doi

10.1088/0031-9155/53/12/020

subject

Has Abstract

pub_date

2008-06-21 00:00:00

pages

3365-80

issue

12

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(08)69559-7

journal_volume

53

pub_type

杂志文章
  • Factors affecting in vivo measurement precision and accuracy of 109Cd K x-ray fluorescence measurements.

    abstract::109Cd K x-ray fluorescence (XRF) measurement systems from two research centres were used to measure tibia lead content in a population (n = 530) of young adults. The group mean bone lead contents (+/-SEM) determined by McMaster University (n = 214) and the University of Maryland (n = 316) were 2.80 +/- 0.51 and 2.33 +...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/9/313

    authors: McNeill FE,Stokes L,Chettle DR,Kaye WE

    更新日期:1999-09-01 00:00:00

  • Comment on 'egs_brachy: a versatile and fast Monte Carlo code for brachytherapy'.

    abstract::In a recent paper (Chamberland et al 2016 Phys. Med. Biol. 61 8214) develop a new Monte Carlo code called egs_brachy for brachytherapy treatments. It is based on EGSnrc, and written in the C++ programming language. In order to benchmark the egs_brachy code, the authors use it in various test case scenarios in which co...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章,信件

    doi:10.1088/1361-6560/aa9ea1

    authors: Yegin G

    更新日期:2018-02-02 00:00:00

  • Spectra from 2.5-15 microm of tissue phantom materials, optical clearing agents and ex vivo human skin: implications for depth profiling of human skin.

    abstract::Infrared measurements have been used to profile or image biological tissue, including human skin. Usually, analysis of such measurements has assumed that infrared absorption is due to water and collagen. Such an assumption may be reasonable for soft tissue, but introduction of exogenous agents into skin or the measure...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/2/402

    authors: Viator JA,Choi B,Peavy GM,Kimel S,Nelson JS

    更新日期:2003-01-21 00:00:00

  • Aluminum equivalence of materials used in diagnostic radiology and its dependence on beam quality.

    abstract::A semi-empirical theory has been derived that relates the aluminum equivalence of various materials used in diagnostic radiology to their attenuation coefficients. The dependence of the aluminum hardness (AHE) and attenuation (AAE) equivalent on the beam quality is described in terms of effective energy. This 'aluminu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/12/006

    authors: Nagel HD

    更新日期:1986-12-01 00:00:00

  • Evolutionary pruning of transfer learned deep convolutional neural network for breast cancer diagnosis in digital breast tomosynthesis.

    abstract::Deep learning models are highly parameterized, resulting in difficulty in inference and transfer learning for image recognition tasks. In this work, we propose a layered pathway evolution method to compress a deep convolutional neural network (DCNN) for classification of masses in digital breast tomosynthesis (DBT). T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabb5b

    authors: Samala RK,Chan HP,Hadjiiski LM,Helvie MA,Richter C,Cha K

    更新日期:2018-05-01 00:00:00

  • Real-time prediction and gating of respiratory motion using an extended Kalman filter and Gaussian process regression.

    abstract::Motion-adaptive radiotherapy aims to deliver a conformal dose to the target tumour with minimal normal tissue exposure by compensating for tumour motion in real time. The prediction as well as the gating of respiratory motion have received much attention over the last two decades for reducing the targeting error of th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/1/233

    authors: Bukhari W,Hong SM

    更新日期:2015-01-07 00:00:00

  • Error propagation in quantitative biplane cineroentgenography.

    abstract::The propagation of errors in quantitative biplane cineroentgenography was investigated to see which variables were the most critical. The analysis was carried out both for the propagation of root-mean-square errors and for errors as derived by a Taylor expansion of the reconstruction equations. The reconstruction is m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/4/009

    authors: Smith WM,Starmer CF

    更新日期:1978-07-01 00:00:00

  • Visually interpretable deep network for diagnosis of breast masses on mammograms.

    abstract::Recently, deep learning technology has achieved various successes in medical image analysis studies including computer-aided diagnosis (CADx). However, current CADx approaches based on deep learning have a limitation in interpreting diagnostic decisions. The limited interpretability is a major challenge for practical ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaef0a

    authors: Kim ST,Lee JH,Lee H,Ro YM

    更新日期:2018-12-04 00:00:00

  • Monte Carlo simulations of a nozzle for the treatment of ocular tumours with high-energy proton beams.

    abstract::By the end of 2002, 33 398 patients worldwide had been treated with proton radiotherapy, 10 829 for eye diseases. The dose prediction algorithms used today for ocular proton therapy treatment planning rely on parameterizations of measured proton dose distributions, i.e., broad-beam and pencil-beam techniques, whose pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/22/002

    authors: Newhauser W,Koch N,Hummel S,Ziegler M,Titt U

    更新日期:2005-11-21 00:00:00

  • A three-dimensional model-based partial volume correction strategy for gated cardiac mouse PET imaging.

    abstract::Quantification in cardiac mouse positron emission tomography (PET) imaging is limited by the imaging spatial resolution. Spillover of left ventricle (LV) myocardial activity into adjacent organs results in partial volume (PV) losses leading to underestimation of myocardial activity. A PV correction method was develope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/13/4309

    authors: Dumouchel T,Thorn S,Kordos M,DaSilva J,Beanlands RS,deKemp RA

    更新日期:2012-07-07 00:00:00

  • In vitro double-integrating-sphere optical properties of tissues between 630 and 1064 nm.

    abstract::The optical properties (absorption and scattering coefficients and the scattering anisotropy factor) were measured in vitro for cartilage, liver, lung, muscle, myocardium, skin, and tumour (colon adenocarcinoma CC 531) at 630, 632.8, 790, 850 and 1064 nm. Rabbits, rats, piglets, goats, and dogs were used to obtain the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/11/017

    authors: Beek JF,Blokland P,Posthumus P,Aalders M,Pickering JW,Sterenborg HJ,van Gemert MJ

    更新日期:1997-11-01 00:00:00

  • Scanned proton radiotherapy for mobile targets-the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics.

    abstract::The most advanced delivery technique for proton radiotherapy is active spot scanning. So far, predominantly static targets have been treated with active spot scanning, since mobile targets in combination with dynamic treatment delivery can lead to interplay effects, causing inhomogeneous dose distributions. One way to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/22/016

    authors: Knopf AC,Hong TS,Lomax A

    更新日期:2011-11-21 00:00:00

  • Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction.

    abstract::Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for correcting them. The goal of this study was to investigate the validity of techniques for random coincidence estimation, with various low-energy thresholds (LETs). Sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/9/012

    authors: Torres-Espallardo I,Rafecas M,Spanoudaki V,McElroy DP,Ziegler SI

    更新日期:2008-05-07 00:00:00

  • Development and validation of a BEAMnrc component module for accurate Monte Carlo modelling of the Varian dynamic Millennium multileaf collimator.

    abstract::A new component module (CM), designated DYNVMLC, was developed to fully model the geometry of the Varian Millennium 120 leaf collimator using the BEAMnrc Monte Carlo code. The model includes details such as the leaf driving screw hole, support railing groove and leaf tips. Further modifications also allow sampling of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/24/004

    authors: Heath E,Seuntjens J

    更新日期:2003-12-21 00:00:00

  • Respiration gated radiotherapy treatment: a technical study.

    abstract::In order to optimize external-beam conformal radiotherapy, patient movement during treatment must be minimized. For treatment on the upper torso, the target organs are known to move substantially due to patient respiration. This paper deals with the technical aspects of gating the radiotherapy beam synchronously with ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/1/007

    authors: Kubo HD,Hill BC

    更新日期:1996-01-01 00:00:00

  • The integration of DVH-based planning aspects into a convex intensity modulated radiation therapy optimization framework.

    abstract::The formulation of intensity modulated radiation therapy (IMRT) planning aspects frequently uses the dose-volume histogram (DVH), whereas plan computations often happen in the more desirable convex IMRT optimization framework. Inspired by a recent publication of Zinchenko et al (2008 Phys. Med. Biol. 53 3231-50), this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N02

    authors: Kratt K,Scherrer A

    更新日期:2009-06-21 00:00:00

  • Optimization of magnetic flux density measurement using multiple RF receiver coils and multi-echo in MREIT.

    abstract::Magnetic Resonance Electrical Impedance Tomography (MREIT) is an MRI method that enables mapping of internal conductivity and/or current density via measurements of magnetic flux density signals. The MREIT measures only the z-component of the induced magnetic flux density B = (Bx, By, Bz) by external current injection...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/4827

    authors: Jeong WC,Chauhan M,Sajib SZ,Kim HJ,Serša I,Kwon OI,Woo EJ

    更新日期:2014-09-07 00:00:00

  • Spectral characterization of local magnetic field inhomogeneities.

    abstract::The purpose of this study was the characterization of local magnetic susceptibility deviations by spectral analysis of their induced magnetic field inhomogeneities. Magnetic resonance spectra and related signal decay curves of local susceptibility deviations were simulated for different volume fractions and compositio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/2/013

    authors: Seppenwoolde JH,van Zijtveld M,Bakker CJ

    更新日期:2005-01-21 00:00:00

  • Head scatter modelling for irregular field shaping and beam intensity modulation.

    abstract::Scattered radiation from within the treatment head can contribute significant dose to all parts of a radiotherapy treatment field. A multileaf collimator may be used to create an arbitrarily shaped field, and may also be used, under dynamic control, to modulate the beam intensity over the field. This method of intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/9/006

    authors: Hounsell AR,Wilkinson JM

    更新日期:1997-09-01 00:00:00

  • Multiple scattering effects in Doppler optical coherence tomography of flowing blood.

    abstract::We investigate the effect of multiple scattering on the optical coherence tomography (OCT) signal and the Doppler OCT signal of flowing blood. Doppler OCT measurements at 1300 nm are performed on flowing diluted porcine blood with hematocrit ranging between 0% and 15%. Measured blood hematocrit and mean red blood cell...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/7/1907

    authors: Kalkman J,Bykov AV,Streekstra GJ,van Leeuwen TG

    更新日期:2012-04-07 00:00:00

  • High resolution bone mineral densitometry with a gamma camera.

    abstract::A technique is described by which the regional distribution of bone mineral can be determined in bone samples from small animals. The technique employs an Anger camera interfaced to a medical computer. High resolution (less than 1 mm) imaging is possible by producing magnified images of the bone samples. Regional dens...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/1/003

    authors: LeBlanc A,Evans H,Jhingran S,Johnson P

    更新日期:1984-01-01 00:00:00

  • SNR and noise measurements for medical imaging: I. A practical approach based on statistical decision theory.

    abstract::A method of measuring the image quality of medical imaging equipment is considered within the framework of statistical decision theory. In this approach, images are regarded as random vectors and image quality is defined in the context of the image information available for performing a specified detection or discrimi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/1/006

    authors: Tapiovaara MJ,Wagner RF

    更新日期:1993-01-01 00:00:00

  • Optimisation of field flatness and depth-dose for therapy electron beams.

    abstract::Curves relating beam energy, scattering foil thickness, central-axis depth-dose, and beam flatness have been generated using data taken on a Siemens 200A betatron. The curve set allows a single combination of tungsten foil thickness and electron beam energy to be chosen that will provide the optimum depth-dose distrib...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/3/007

    authors: Marbach JR,Almond PR

    更新日期:1981-05-01 00:00:00

  • The impact of morphology on light transport in cancellous bone.

    abstract::In recent years, optical techniques based on diffusion approximation have demonstrated their ability to gain rich spectral information about bone. However, these methods normally assume homogeneity, while cancellous bone and marrow form a highly heterogeneous two-phase medium. This paper studies the limitations of thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/17/003

    authors: Margallo-Balbás E,Taroni P,Pifferi A,Koolstra JH,v Ruijven LJ,French PJ

    更新日期:2010-09-07 00:00:00

  • A complete distortion correction for MR images: II. Rectification of static-field inhomogeneities by similarity-based profile mapping.

    abstract::Radiotherapy treatment planning relies on the use of geometrically correct images. This paper presents a fully automatic tool for correcting MR images for the effects of B(0) inhomogeneities. The post-processing method is based on the gradient-reversal technique of Chang and Fitzpatrick (1992 IEEE Trans. Med. Imaging ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/11/014

    authors: Reinsberg SA,Doran SJ,Charles-Edwards EM,Leach MO

    更新日期:2005-06-07 00:00:00

  • A motion-incorporated reconstruction method for gated PET studies.

    abstract::Cardiac and respiratory motion artefacts in PET imaging have been traditionally resolved by acquiring the data in gated mode. However, gated PET images are usually characterized by high noise content due to their low photon statistics. In this paper, we present a novel 4D model for the PET imaging system, which can in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/15/012

    authors: Qiao F,Pan T,Clark JW Jr,Mawlawi OR

    更新日期:2006-08-07 00:00:00

  • Treatment time reduction for large thermal lesions by using a multiple 1D ultrasound phased array system.

    abstract::To generate large thermal lesions in ultrasound thermal therapy, cooling intermissions are usually introduced during the treatment to prevent near-field heating, which leads to a long treatment time. A possible strategy to shorten the total treatment time is to eliminate the cooling intermissions. In this study, the t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/9/307

    authors: Liu HL,Chen YY,Yen JY,Lin WL

    更新日期:2003-05-07 00:00:00

  • A method for determining the diffusion coefficient in Fe(II/III) radiation dosimetry gels using finite elements.

    abstract::Magnetic resonance imaging (MRI) may be used to image three-dimensional dose distributions of ionizing radiation in tissue equivalent gels infused with ferrous sulphate solutions, commonly known as Fricke gels. In this technique, ferrous (Fe2+) ions are oxidized to ferric (Fe3+) ions by free radicals produced by ioniz...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/9/013

    authors: Harris PJ,Piercy A,Baldock C

    更新日期:1996-09-01 00:00:00

  • Concentrations of Fe, Cu and Zn in breast tissue: a synchrotron XRF study.

    abstract::An x-ray fluorescence system with a synchrotron radiation source was used to quantify the levels of iron, copper and zinc in breast tissue specimens. Healthy tissue and breast carcinomas were investigated as an aid to understanding the mechanisms of breast cancer and as a possible complementary diagnostic tool. Eighty...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/13/310

    authors: Geraki K,Farquharson MJ,Bradley DA

    更新日期:2002-07-07 00:00:00

  • Multiobjective evolutionary optimization of the number of beams, their orientations and weights for intensity-modulated radiation therapy.

    abstract::We propose a hybrid multiobjective (MO) evolutionary optimization algorithm (MOEA) for intensity-modulated radiotherapy inverse planning and apply it to optimize the number of incident beams, their orientations and intensity profiles. The algorithm produces a set of efficient solutions, which represent different clini...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/5/007

    authors: Schreibmann E,Lahanas M,Xing L,Baltas D

    更新日期:2004-03-07 00:00:00