A method for determining the diffusion coefficient in Fe(II/III) radiation dosimetry gels using finite elements.

Abstract:

:Magnetic resonance imaging (MRI) may be used to image three-dimensional dose distributions of ionizing radiation in tissue equivalent gels infused with ferrous sulphate solutions, commonly known as Fricke gels. In this technique, ferrous (Fe2+) ions are oxidized to ferric (Fe3+) ions by free radicals produced by ionizing radiation. A limitation on this technique is the diffusion of ferric (Fe3+) ions in the gel. A method is presented for evaluating the diffusion coefficient in Fricke gels. Finite elements are used to model variations of the concentration in space, coupled with an analytical scheme to integrate the resulting system of equations through time. This method may be used for problems with one, two or three space dimensions and with arbitrary initial and boundary conditions. Results are presented for one- and two-dimensional data.

journal_name

Phys Med Biol

authors

Harris PJ,Piercy A,Baldock C

doi

10.1088/0031-9155/41/9/013

subject

Has Abstract

pub_date

1996-09-01 00:00:00

pages

1745-53

issue

9

eissn

0031-9155

issn

1361-6560

journal_volume

41

pub_type

杂志文章
  • Modeling the radiation-induced cell death in a therapeutic proton beam using thermoluminescent detectors and radiation transport simulations.

    abstract::Changes in the relative biological effectiveness (RBE) of the radiation-induced cell killing of human salivary glands (HSG) were assessed along the Bragg peak of a 60 MeV clinical proton beam by means of coupling biophysical models with the results of Monte Carlo radiation transport simulations and experimental measur...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab491f

    authors: Parisi A,Olko P,Swakoń J,Horwacik T,Jabłoński H,Malinowski L,Nowak T,Struelens L,Vanhavere F

    更新日期:2020-01-10 00:00:00

  • Thermoluminescent response and relative efficiency of TLD-100 exposed to low-energy x-rays.

    abstract::The dose-response of LiF:Mg,Ti (TLD-100) exposed to 15 and 35 kVp (8.0 +/- 0.1 and 8.1 +/- 0.1 keV effective energy respectively) x-rays and 60Co gamma-rays has been measured in the dose interval from (1.2-5.4) x 10(3) Gy for x-rays, and from 0.14 to 850 Gy for gamma-rays. In both cases the total TL signal and glow cu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/006

    authors: Gamboa-deBuen I,Buenfil AE,Ruiz CG,Rodríguez-Villafuerte M,Flores A,Brandan ME

    更新日期:1998-08-01 00:00:00

  • Denoising of multi b-value diffusion-weighted MR images using deep image prior.

    abstract::The clinical value of multiple b-value diffusion-weighted (DW) magnetic resonance imaging (MRI) has been shown in many studies. However, DW-MRI often suffers from low signal-to-noise ratio, especially at high b-values. To address this limitation, we present an image denoising method based on the concept of deep image ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8105

    authors: Lin YC,Huang HM

    更新日期:2020-05-11 00:00:00

  • HeinzelCluster: accelerated reconstruction for FORE and OSEM3D.

    abstract::Using iterative three-dimensional (3D) reconstruction techniques for reconstruction of positron emission tomography (PET) is not feasible on most single-processor machines due to the excessive computing time needed, especially so for the large sinogram sizes of our high-resolution research tomograph (HRRT). In our fir...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/15/307

    authors: Vollmar S,Michel C,Treffert JT,Newport DF,Casey M,Knöss C,Wienhard K,Liu X,Defrise M,Heiss WD

    更新日期:2002-08-07 00:00:00

  • MR-guided transcranial brain HIFU in small animal models.

    abstract::Recent studies have demonstrated the feasibility of transcranial high-intensity focused ultrasound (HIFU) therapy in the brain using adaptive focusing techniques. However, the complexity of the procedures imposes provision of accurate targeting, monitoring and control of this emerging therapeutic modality in order to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/2/003

    authors: Larrat B,Pernot M,Aubry JF,Dervishi E,Sinkus R,Seilhean D,Marie Y,Boch AL,Fink M,Tanter M

    更新日期:2010-01-21 00:00:00

  • Changes in lung tumor shape during respiration.

    abstract::Evidence that some lung tumors change shape during respiration is derived from respiratory gated CT data by statistical shape modeling and image manipulation. Some tumors behave as rigid objects while others show systematic shape changes. Two views of lung motion are presented to allow analysis of the results. In the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/4/919

    authors: Kyriakou E,McKenzie DR

    更新日期:2012-02-21 00:00:00

  • Scanned proton radiotherapy for mobile targets-the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics.

    abstract::The most advanced delivery technique for proton radiotherapy is active spot scanning. So far, predominantly static targets have been treated with active spot scanning, since mobile targets in combination with dynamic treatment delivery can lead to interplay effects, causing inhomogeneous dose distributions. One way to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/22/016

    authors: Knopf AC,Hong TS,Lomax A

    更新日期:2011-11-21 00:00:00

  • Optimal material discrimination using spectral x-ray imaging.

    abstract::Spectral x-ray imaging using novel photon counting x-ray detectors (PCDs) with energy resolving abilities is capable of providing energy-selective images. PCDs have energy thresholds, enabling the classification of photons into multiple energy bins. The extra energy information provided may allow materials such as iod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/18/012

    authors: Nik SJ,Meyer J,Watts R

    更新日期:2011-09-21 00:00:00

  • 2D convolution kernels of ionization chambers used for photon-beam dosimetry in magnetic fields: the advantage of small over large chamber dimensions.

    abstract::This study aims at developing an optimization strategy for photon-beam dosimetry in magnetic fields using ionization chambers. Similar to the familiar case in the absence of a magnetic field, detectors should be selected under the criterion that their measured 2D signal profiles M(x,y) approximate the absorbed dose to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab50c

    authors: Looe HK,Delfs B,Poppinga D,Harder D,Poppe B

    更新日期:2018-03-29 00:00:00

  • Synchrotron microangiography with no contrast agent.

    abstract::Coherent x-rays from synchrotron sources are increasingly used in non-conventional radiological techniques ('phase-contrast' radiology). Our experiments demonstrate that by using white (unmonochromatic) radiation and a time-resolving system, it is possible to image microscopic details of moving blood vessels in differ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/4/002

    authors: Hwu Y,Tsai WL,Je JH,Seol SK,Kim B,Groso A,Margaritondo G,Lee KH,Seong JK

    更新日期:2004-02-21 00:00:00

  • Radiation dose factors for alpha-emitters in osteons and some considerations on dose non-uniformity ratios and relative distribution factors.

    abstract::Dose factors for locations within a tissue-filled cylindrical cavity bounded by an infinite medium of bone labelled with an alpha-emitter are calculated by means of a Monte Carlo procedure. The calculational approach is general and allows us to determine dose factors for specific distances or target volumes defined by...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/3/007

    authors: Polig E

    更新日期:1989-03-01 00:00:00

  • Estimation of the absorption coefficients of two-layered media by a simple method using spatially and time-resolved reflectances.

    abstract::Our newly developed method using spatially and time-resolved reflectances can easily estimate the absorption coefficients of each layer in a two-layered medium if the thickness of the upper layer and the reduced scattering coefficients of the two layers are known a priori. We experimentally validated this method using...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/16/014

    authors: Shimada M,Sato C,Hoshi Y,Yamada Y

    更新日期:2009-08-21 00:00:00

  • Dose distribution measurements by MRI of a phantom containing lung tissue equivalent compartments made of ferrous sulphate gel.

    abstract::Gel dosimetry based on magnetic resonance imaging (MRI) has previously been shown to provide verification of calculated dose distributions in soft tissue equivalent homogeneous phantoms. This study demonstrates how measurements of dose distribution can also be achieved in a phantom containing porous, lung-equivalent, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/10/303

    authors: Olberg S,Skretting A,Bruland O,Olsen DR

    更新日期:2000-10-01 00:00:00

  • A study of the impact of x-ray tube performance on angiography system imaging efficiency.

    abstract::This work compared the impact of x-ray tube performance and automatic dose rate control (ADRC) parameter selection on system imaging efficiency of two Siemens angiography systems: a Siemens Megalix x-ray tube installed on an Artis Zee system (denoted 'MEGALIX') and a newer generation Gigalix x-ray tube installed on an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abbb7a

    authors: Dehairs M,Bosmans H,Marshall NW

    更新日期:2020-11-24 00:00:00

  • Monte Carlo simulations to support start-up and treatment planning of scanned proton and carbon ion therapy at a synchrotron-based facility.

    abstract::Reliable treatment planning of highly conformal scanned ion beam therapy demands accurate tools for the determination and characterization of the individual pencil-like beams building up the integral dose delivery and related mixed radiation field. At present, clinically practicable inverse treatment planning systems ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3759

    authors: Parodi K,Mairani A,Brons S,Hasch BG,Sommerer F,Naumann J,Jäkel O,Haberer T,Debus J

    更新日期:2012-06-21 00:00:00

  • Modifying proton fluence spectra to generate spread-out Bragg peaks with laser accelerated proton beams.

    abstract::Currently, energy spectra of laser accelerated proton beams are far from being monoenergetic. For their application in radiation therapy, energy selection systems using magnetic fields have been proposed to single out particles with the desired energy. These systems allow the choice of protons between a lowest and a h...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/19/N04

    authors: Schell S,Wilkens JJ

    更新日期:2009-10-07 00:00:00

  • Development of 4D mathematical observer models for the task-based evaluation of gated myocardial perfusion SPECT.

    abstract::This paper presents two 4D mathematical observer models for the detection of motion defects in 4D gated medical images. Their performance was compared with results from human observers in detecting a regional motion abnormality in simulated 4D gated myocardial perfusion (MP) SPECT images. The first 4D mathematical obs...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/7/2751

    authors: Lee TS,Frey EC,Tsui BM

    更新日期:2015-04-07 00:00:00

  • Quantitative analysis of a micro array anode structured target for hard x-ray grating interferometry.

    abstract::Talbot-Lau interferometry (TLI) provides additional contrast modes for x-ray imaging that are complementary to conventional absorption radiography. TLI is particularly interesting because it is one of the few practical methods for realizing phase contrast with x-rays that is compatible with large-spot high power x-ray...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab6578

    authors: Zan G,Vine DJ,Yun W,Lewis SJY,Wang Q,Wang G

    更新日期:2020-02-04 00:00:00

  • Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification.

    abstract::A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/18/6241

    authors: Vandecasteele J,De Deene Y

    更新日期:2013-09-21 00:00:00

  • Bulk optical properties of healthy female breast tissue.

    abstract::We have measured the bulk optical properties of healthy female breast tissues in vivo in the parallel plate, transmission geometry. Fifty-two volunteers were measured. Blood volume and blood oxygen saturation were derived from the optical property data using a novel method that employed a priori spectral information t...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/47/16/302

    authors: Durduran T,Choe R,Culver JP,Zubkov L,Holboke MJ,Giammarco J,Chance B,Yodh AG

    更新日期:2002-08-21 00:00:00

  • Optimization of MAGIC gel formulation for three-dimensional radiation therapy dosimetry.

    abstract::Polymer gel dosimetry aims to provide three-dimensional images of radiation therapy dose distributions in irradiated aqueous gels. The first gels required manufacture in an oxygen-free environment, but later the MAGIC formulation was introduced, which could be made in normal atmospheric conditions. Here we report our ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/10/N03

    authors: Luci JJ,Whitney HM,Gore JC

    更新日期:2007-05-21 00:00:00

  • 4D digital tomosynthesis image reconstruction using brute force-based adaptive total variation (BF-ATV) in a prototype LINAC system.

    abstract::Respiratory-correlated cone-beam CT (CBCT) not only inhibits rapid scanning due to the slow speed of the LINAC head gantry rotation, but its implementation for routine patient imaging is impractical because of the high radiation dose delivered during the process. Digital tomosynthesis (DTS) is a potentially faster tec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0d50

    authors: Choi S,Lee S,Kang YN,Hsieh SS,Kim HJ

    更新日期:2019-05-02 00:00:00

  • A facility for in vivo measurement of kidney and liver cadmium by neutron capture prompt gamma ray analysis.

    abstract::An in vivo method for the determination of Cd levels in human kidney and liver has been developed. The method allows detection of absolute quantities of Cd in the left kidney and Cd concentration in the liver. The limit of detection of cadmium is 2.5 mg for the left kidney and 1.8 microgram/g (wet weight) for the live...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/6/003

    authors: Vartsky D,Ellis KJ,Chen NS,Cohn SH

    更新日期:1977-11-01 00:00:00

  • Directional x-ray dark-field imaging.

    abstract::We introduce a novel x-ray imaging approach that yields information about the local texture of structures smaller than the image pixel resolution inside an object. The approach is based on a recently developed x-ray dark-field imaging technique, using scattering from sub-micron structures in the sample. We show that t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/004

    authors: Jensen TH,Bech M,Bunk O,Donath T,David C,Feidenhans'l R,Pfeiffer F

    更新日期:2010-06-21 00:00:00

  • Assessment of the effects of pixel loss on image quality in direct digital radiography.

    abstract::Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitive image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/6/008

    authors: Padgett R,Kotre CJ

    更新日期:2004-03-21 00:00:00

  • The effect of authentic metallic implants on the SAR distribution of the head exposed to 900, 1800 and 2450 MHz dipole near field.

    abstract::As the use of radiofrequency (RF) electromagnetic (EM) fields has increased along with increased use of wireless communication, the possible related health risks have also been widely discussed. One safety aspect is the interaction of medical implants and RF devices like mobile phones. In the literature, effects on ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/001

    authors: Virtanen H,Keshvari J,Lappalainen R

    更新日期:2007-03-07 00:00:00

  • Measurement of effective detective quantum efficiency for a photon counting scanning mammography system and comparison with two flat panel full-field digital mammography systems.

    abstract::Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa307

    authors: Wood TJ,Moore CS,Saunderson JR,Beavis AW

    更新日期:2018-01-16 00:00:00

  • Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates.

    abstract::In response to the recognized fragility of reactor-produced (99)Mo supply, direct production of (99m)Tc via (100)Mo(p,2n)(99m)Tc reaction using medical cyclotrons has been investigated. However, due to the existence of other Molybdenum (Mo) isotopes in the target, in parallel with (99m)Tc, other technetium (Tc) radioa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/2/542

    authors: Hou X,Tanguay J,Buckley K,Schaffer P,Bénard F,Ruth TJ,Celler A

    更新日期:2016-01-21 00:00:00

  • Generalized method for computation of true thickness and x-ray intensity information in highly blurred sub-millimeter bone features in clinical CT images.

    abstract::In clinical computed tomography (CT) images, cortical bone features with sub-millimeter (sub-mm) thickness are substantially blurred, such that their thickness is overestimated and their intensity appears underestimated. Therefore, any inquiry of the geometry or the density of such bones based on these images is sever...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/23/8099

    authors: Pakdel A,Robert N,Fialkov J,Maloul A,Whyne C

    更新日期:2012-12-07 00:00:00

  • A small animal holding fixture system with positional reproducibility for longitudinal multimodal imaging.

    abstract::This study presents a combined small animal holding fixture system, termed a 'bridge capsule', which provides for small animal re-fixation with positional reproducibility. This system comprises separate holding fixtures for the head and lower body and a connecting part to a gas anesthesia system. A mouse is fixed in p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/14/011

    authors: Kokuryo D,Kimura Y,Obata T,Yamaya T,Kawamura K,Zhang MR,Kanno I,Aoki I

    更新日期:2010-07-21 00:00:00