Single-dose pharmacokinetics and safety pharmacodynamics of formoterol delivered by two different dry powder inhalers.

Abstract:

:The present study aimed at assessing the pharmacokinetics (PK) and safety pharmacodynamics (PD) of 24 microg formoterol delivered via a Novolizer and via an Aerolizer in healthy subjects. This was a randomized, open-label, crossover study. Beside PK, serum potassium, and glucose profiles, vital signs, and ECG were recorded. Twenty-nine subjects (15 males) were enrolled. The inhalation maneuver had to be repeated by 19 subjects using the Aerolizer and 1 subject using a Novolizer. While eight (28%) subjects completely failed to inhale correctly via the Aerolizer (four were identified by the investigators immediately after inhalation, another four by bioanalytics later), all did it correctly via the Novolizer. The bioanalytical evaluation indicated two distinct serum peaks. The shapes of serum concentration-time profiles were more homogeneous after inhaling via the Novolizer than via the Aerolizer. After adjusting for the delivered dose the Cmax of formoterol predicting pulmonary absorption was higher after the Novolizer than after the Aerolizer, while the average AUC0-infinity levels indicating total systemic exposure were equivalent. There was no evidence for different pharmacodynamic behavior with respect to serum potassium and glucose profiles, vital signs, and ECG. The Novolizer yields higher pulmonary absorption of formoterol than the Aerolizer and equivalent safety profiles. Considering the lower variability of PK profiles and the higher proportion of correct inhalations, formoterol is more reliably inhaled via Novolizer.

authors

Petzold U,Kremer HJ,Nguyen DT,Munzel U,Dietrich H,Maus J

doi

10.1089/jamp.2008.0690

subject

Has Abstract

pub_date

2008-09-01 00:00:00

pages

309-19

issue

3

eissn

1941-2711

issn

1941-2703

journal_volume

21

pub_type

杂志文章,随机对照试验
  • Targeting aerosolized drugs to the conducting airways using very large particles and extremely slow inhalations.

    abstract:BACKGROUND:The site of deposition in the respiratory tract for aerosolized, inhaled therapeutic drugs depends on both the particles' aerodynamic size and the patient's breathing pattern. METHODS:In 21 healthy subjects with normal lung function, we evaluated an extremely slow inhalation of a large 9.5-μm MMAD particle ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0711

    authors: Zeman KL,Wu J,Bennett WD

    更新日期:2010-12-01 00:00:00

  • Collecting exhaled breath condensate (EBC) with two condensers in series: a promising technique for studying the mechanisms of EBC formation, and the volatility of selected biomarkers.

    abstract::Exhaled breath condensate (EBC) consists mainly of water, but also contains semivolatile and nonvolatile compounds. The aim of this study was to develop a system in which two condensers are simultaneously used in series to clarify the mechanisms of EBC condensation. Two aliquots of EBC (EBC1 and EBC2) were collected f...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2007.0644

    authors: Corradi M,Goldoni M,Caglieri A,Folesani G,Poli D,Corti M,Mutti A

    更新日期:2008-03-01 00:00:00

  • An Apparatus to Deliver Mannitol Powder for Bronchial Provocation in Children Under Six Years Old.

    abstract:BACKGROUND:Currently bronchial provocation testing (BPT) using mannitol powder cannot be performed in children under 6 years. A primary reason is it is challenging for children at this age to generate a consistent inspiratory effort to inhale mannitol efficiently from a dry powder inhaler. A prototype system, which doe...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1208

    authors: Tang P,Leung SS,Hor E,Ruzycki CA,Carrigy NB,Finlay WH,Brannan JD,Devadason S,Anderson SD,Sly PD,Samnick K,Chan HK

    更新日期:2015-12-01 00:00:00

  • Development of an in vitro model to assess deposition of aerosol particles in a representative replica of the rat's respiratory tract.

    abstract:BACKGROUND:Small rodents continue to be the mainstay for the assessment of pharmacological and toxicological data of inhaled therapeutics. For meaningful interpretation of the results information about deposition of aerosol particles in the respiratory tract is warranted, but not trivial to obtain for animals with nose...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2011.0902

    authors: Ahmed A,Prime D,Burnell PK,Högger P

    更新日期:2012-06-01 00:00:00

  • Assessment of the Power Required for Optimal Use of Current Inhalation Devices.

    abstract:: Background: Inhalation of medications is the cornerstone in the treatment of patients with lung diseases. A variety of inhalation devices exists and each device has specific requirements to achieve optimum inhalation of the drug. The goal of this study was to establish a c...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1376

    authors: Pohlmann G,Hohlfeld JM,Haidl P,Pankalla J,Cloes RM

    更新日期:2018-12-01 00:00:00

  • The Impact of Common Inhaler Errors on Drug Delivery: Investigating Critical Errors with a Dry Powder Inhaler.

    abstract:BACKGROUND:Researchers, using checklists, have identified that 30%-90% of patients make errors in inhaler use. It is not certain whether these errors affect the delivery of medication. We have developed an electronic monitor (INCA™) that records audio each time an inhaler is used, providing objective information on inh...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2016.1334

    authors: Sulaiman I,Seheult J,Sadasivuni N,MacHale E,Killane I,Giannoutsos S,Cushen B,Mokoka MC,Bhreathnach AS,Boland F,Reilly RB,Costello RW

    更新日期:2017-08-01 00:00:00

  • Using MRI to measure aerosol deposition.

    abstract::This article provides a concise review of the use of magnetic resonance imaging (MRI) for measurement of regional aerosol deposition in the lungs. Basic aspects of MRI and its use in lung imaging and measurement of regional ventilation are introduced. Imaging of hydrogen protons (water) and inhaled hyperpolarized gase...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2011.0897

    authors: Thompson RB,Finlay WH

    更新日期:2012-04-01 00:00:00

  • Model Calculations of Regional Deposition and Disposition for Single Doses of Inhaled Liposomal and Dry Powder Ciprofloxacin.

    abstract:BACKGROUND:Model predictions of regional deposition in the respiratory tract are useful in assessing factors that influence the effectiveness of aerosol delivery. Regional deposition models have previously been coupled with models of mucous production and clearance to estimate initial concentrations of drug deposited i...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1377

    authors: Martin AR,Finlay WH

    更新日期:2018-02-01 00:00:00

  • Physicochemical and Pharmacokinetic Evaluation of Spray-Dried Coformulation of Salvia miltiorrhiza Polyphenolic Acid and L-Leucine with Improved Bioavailability.

    abstract:: Background: Salvia miltiorrhiza polyphenolic acid (SMPA) is effective in the treatment of cardiovascular diseases and currently it is administered orally or intravenously. However, SMPA is poorly absorbed orally and quickly eliminated in vivo. A long-term frequent intraveno...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2019.1538

    authors: Lu P,Xing Y,Peng H,Liu Z,Zhou QT,Xue Z,Ma Z,Kebebe D,Zhang B,Liu H

    更新日期:2020-04-01 00:00:00

  • Vitamin A Supplementation by Endotracheal Application of a Nano-encapsulated Preparation Is Feasible in Ventilated Preterm Lambs.

    abstract:BACKGROUND:Vitamin A (VA) is crucial for lung growth and development. In premature infants, inadequate VA levels are associated with an increased risk of bronchopulmonary dysplasia (BPD). Intramuscular VA supplementation has been shown to decrease the incidence of BPD, but is not widely used in the clinical setting due...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1438

    authors: Wahl HB,Hütten MC,Monz D,Tutdibi E,Ophelders D,Nikiforou M,Tschernig T,Gortner L,Nohr D,Biesalski HK,Kramer BW

    更新日期:2018-12-01 00:00:00

  • Pulmonary Toxicity of Benzalkonium Chloride.

    abstract::The available toxicity data of benzalkonium chloride (BKC) clearly shows that it is toxic; however, the weight of evidence favors the view that at doses encountered in nasally and orally inhaled pharmaceutical preparations it is well tolerated. The adverse toxicological data predominantly come from in vitro and animal...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2017.1390

    authors: Johnson NF

    更新日期:2018-02-01 00:00:00

  • Effect of Posture on Regional Deposition of Coarse Particles in the Healthy Human Lung.

    abstract:BACKGROUND:Understanding the regional partition of deposition of inhaled particles within the lung is important for improving targeted delivery of inhaled aerosolized drugs. One factor affecting regional deposition is gravity. As the lung deforms under its own weight, changes in lung volume, in airway geometries, and i...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1189

    authors: Sá RC,Zeman KL,Bennett WD,Prisk GK,Darquenne C

    更新日期:2015-12-01 00:00:00

  • A Novel In-Line Delivery System to Administer Dry Powder Mannitol to Mechanically Ventilated Patients.

    abstract:BACKGROUND:Mechanically ventilated patients commonly suffer from ventilator-associated pneumonia, hypoxemia, and other lower respiratory tract infection as a result of pathogen colonization and poor sputum clearance. Consequently, there is a high rate of morbidity and mortality in these patients. Dry powder mannitol in...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2016.1320

    authors: Feng B,Tang P,Leung SS,Dhanani J,Chan HK

    更新日期:2017-04-01 00:00:00

  • The I-neb Adaptive Aerosol Delivery System enhances delivery of alpha1-antitrypsin with controlled inhalation.

    abstract:BACKGROUND:Inhaled alpha1-antitrypsin (AAT) is being developed for treatment of cystic fibrosis to protect the lungs from excessive free elastase. High drug costs mandate a very efficient aerosol system to deliver a high payload to the airways. The I-neb Adaptive Aerosol Delivery (AAD) System is a portable, electronic,...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2009.0793

    authors: Geller DE,Kesser KC

    更新日期:2010-04-01 00:00:00

  • Use of a Remote Inhaler Monitoring Device to Measure Change in Inhaler Use with Chronic Obstructive Pulmonary Disease Exacerbations.

    abstract:BACKGROUND:Remote inhaler monitoring is an emerging technology that enables the healthcare team to monitor the time and location of a patient's inhaler use. We assessed the feasibility of remote inhaler monitoring for chronic obstructive pulmonary disease (COPD) patients and the pattern of albuterol inhaler use associa...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1383

    authors: Sumino K,Locke ER,Magzamen S,Gylys-Colwell I,Humblet O,Nguyen HQ,Thomas RM,Fan VS

    更新日期:2018-06-01 00:00:00

  • Characterization of Medication Velocity and Size Distribution from Pressurized Metered-Dose Inhalers by Phase Doppler Anemometry.

    abstract:BACKGROUND:Particle size and velocity are two of the most significant factors that impact the deposition of pressurized metered-dose inhaler (pMDI) sprays in the mouth cavity. pMDIs are prominently used around the world in the treatment of patients suffering from a variety of lung diseases such as asthma and chronic ob...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1264

    authors: Alatrash A,Matida E

    更新日期:2016-12-01 00:00:00

  • Factors Determining In Vitro Lung Deposition of Albuterol Aerosol Delivered by Ventolin Metered-Dose Inhaler.

    abstract:BACKGROUND:The effectiveness of metered-dose inhalers (MDIs) in delivering medication to the lungs highly depends on its correct usage technique. Current guidelines state optimal technique for high lung deposition should include a slow inhalation (>5 seconds) at an inspiratory flow rate of 30 L/min and inhaler actuatio...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1278

    authors: Biswas R,Hanania NA,Sabharwal A

    更新日期:2017-08-01 00:00:00

  • Pharmacokinetic Comparison of a Unit Dose Dry Powder Inhaler with a Multidose Dry Powder Inhaler for Delivery of Fluticasone Furoate.

    abstract:BACKGROUND:The unit dose dry powder inhaler (UD-DPI) is being considered as an alternative inhaler platform that, if developed, has the potential to improve access to inhaled respiratory medicines in developing countries. AIM:This study compared the systemic exposure of fluticasone furoate after delivery from the UD-D...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/jamp.2016.1322

    authors: Mehta R,Moore A,Riddell K,Joshi S,Chan R

    更新日期:2017-10-01 00:00:00

  • Validation of the 'Test of the Adherence to Inhalers' (TAI) for Asthma and COPD Patients.

    abstract:BACKGROUND:To validate the 'Test of Adherence to Inhalers' (TAI), a 12-item questionnaire designed to assess the adherence to inhalers in patients with COPD or asthma. METHODS:A total of 1009 patients with asthma or COPD participated in a cross-sectional multicenter study. Patients with electronic adherence ≥80% were ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,多中心研究

    doi:10.1089/jamp.2015.1212

    authors: Plaza V,Fernández-Rodríguez C,Melero C,Cosío BG,Entrenas LM,de Llano LP,Gutiérrez-Pereyra F,Tarragona E,Palomino R,López-Viña A,TAI Study Group.

    更新日期:2016-04-01 00:00:00

  • Nebulized medications for the treatment of dyspnea: a literature review.

    abstract:BACKGROUND:Dyspnea significantly impacts quality of life and is one of the most common symptoms in advanced illness. Systemically-administered opioids and benzodiazepines have been the most studied and utilized pharmacologic treatments for refractory dyspnea. Less attention has been given to the use of these medication...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2014.1136

    authors: Boyden JY,Connor SR,Otolorin L,Nathan SD,Fine PG,Davis MS,Muir JC

    更新日期:2015-02-01 00:00:00

  • Decreased level of PDCD4 (programmed cell death 4) protein activated cell proliferation in the lung of A/J mouse.

    abstract:BACKGROUND:Programmed cell death 4 (PDCD4), a protein that binds to eukaryotic initiation factor 4A (eIF4A), inhibits the initiation of translation. Although a number of tumor suppressors target transcription, Pdcd4 is the first suppressor targeting protein translation, and has also been suggested to function as a tumo...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2009.0778

    authors: Hwang SK,Minai-Tehrani A,Lim HT,Shin JY,An GH,Lee KH,Park KR,Kim YS,Beck GR Jr,Yang HS,Cho MH

    更新日期:2010-10-01 00:00:00

  • Sustained mechanical and clinical functionality of the flexhaler dry powder inhaler.

    abstract::Flexhaler is a multiple-dose, inspiratory flow-driven dry powder inhaler that is a newer version of Turbuhaler, and is identical to the Symbicort Turbuhaler. Sustained performance is of the utmost importance to ensure consistent drug delivery throughout the lifespan of the inhaler. We report functionality testing resu...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0700

    authors: Lööf T,Elfman P,Ström P,Törngren A,Borgström L

    更新日期:2008-12-01 00:00:00

  • Aerosolizing Lipid Dispersions Enables Antibiotic Transport Across Mimics of the Lung Airway Surface Even in the Presence of Pre-existing Lipid Monolayers.

    abstract:BACKGROUND:Secondary lung infections are the primary cause of morbidity associated with cystic fibrosis lung disease. Aerosolized antibiotic inhalation is potentially advantageous but has limited effectiveness due to altered airway aerodynamics and deposition patterns that limit drug access to infected regions. One pot...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1412

    authors: Iasella SV,Stetten AZ,Corcoran TE,Garoff S,Przybycien TM,Tilton RD

    更新日期:2018-08-01 00:00:00

  • Dry-Powder Inhaler Formulation of Rifampicin: An Improved Targeted Delivery System for Alveolar Tuberculosis.

    abstract:BACKGROUND:The delivery of antitubercular drugs through direct lung targeting can lead to reduction in the dose as well as side effects of the drug. In the present investigation, carrier (lactose)-based dry-powder inhaler of rifampicin was prepared to achieve direct targeting of the drug into the lungs. METHODS:The dr...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1379

    authors: Rawal T,Kremer L,Halloum I,Butani S

    更新日期:2017-12-01 00:00:00

  • Deposition Mechanisms.

    abstract::The success of inhalation therapy is not only dependent upon the pharmacology of the drugs being inhaled but also upon the site and extent of deposition in the respiratory tract. Similarly, the toxicity of environmental and industrial particulate matter is affected not only by the nature of the dust but also by the am...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.29029.cd

    authors: Darquenne C

    更新日期:2020-08-01 00:00:00

  • Aerosol Therapy in Adults Receiving High Flow Nasal Cannula Oxygen Therapy.

    abstract:BACKGROUND:High flow nasal cannula oxygen therapy (HFT) is increasingly used in intensive and emergency care departments. Patients suffering from respiratory failure, who are likely to benefit from HFT, may require aerosolized bronchodilators; therefore, combining nebulization with HFT may be relevant. This study aimed...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1219

    authors: Réminiac F,Vecellio L,Heuzé-Vourc'h N,Petitcollin A,Respaud R,Cabrera M,Pennec DL,Diot P,Ehrmann S

    更新日期:2016-04-01 00:00:00

  • Optimal delivery of aerosols to infants during mechanical ventilation.

    abstract:PURPOSE:The objective of this study was to determine optimal aerosol delivery conditions for a full-term (3.6 kg) infant receiving invasive mechanical ventilation by evaluating the effects of aerosol particle size, a new wye connector, and timing of aerosol delivery. METHODS:In vitro experiments used a vibrating mesh ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2013.1077

    authors: Longest PW,Azimi M,Hindle M

    更新日期:2014-10-01 00:00:00

  • Physiologically Based Pharmacokinetic/Pharmacodynamic Modeling Accurately Predicts the Better Bronchodilatory Effect of Inhaled Versus Oral Salbutamol Dosage Forms.

    abstract:BACKGROUND:Predicting local lung tissue pharmacodynamic (PD) responses of inhaled drugs is a longstanding challenge related to the lack of experimental techniques to determine local free drug concentrations. This has prompted the use of physiologically based pharmacokinetic (PBPK) modeling to potentially predict local ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1436

    authors: Boger E,Fridén M

    更新日期:2019-02-01 00:00:00

  • Correcting Photo Reflection Method Output and Its Application in the Dynamic Analysis of Particle Release from Dry Powder Inhalers.

    abstract:: Background: The photo reflection method (PRM) is used to measure light reflected from particles released from dry powder inhalers (DPIs). This simple method depicts time trajectories of released drugs; however, it underestimates the number of particles at high peak inhalat...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.1610

    authors: Kondo T,Hibino M,Tanigaki T,Tajiri S,Horiuchi S

    更新日期:2020-11-04 00:00:00

  • A New Quantitative Method for Evaluating Dry Powder Inhalation Efficiency in Asthma Patients.

    abstract:PURPOSE:Many methods have been developed to evaluate dry powder inhalation techniques and their efficiency for disease control in asthma patients. However, it is difficult to apply these methods to clinical practice and research. In this study, we introduce a simple new method that can be applied to dry powder inhalati...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1193

    authors: Liang Y,Hu H,Tian C,Lei Y,Liu C,Luo F

    更新日期:2016-10-01 00:00:00