Use of a Remote Inhaler Monitoring Device to Measure Change in Inhaler Use with Chronic Obstructive Pulmonary Disease Exacerbations.

Abstract:

BACKGROUND:Remote inhaler monitoring is an emerging technology that enables the healthcare team to monitor the time and location of a patient's inhaler use. We assessed the feasibility of remote inhaler monitoring for chronic obstructive pulmonary disease (COPD) patients and the pattern of albuterol inhaler use associated with COPD exacerbations. METHODS:Thirty-five participants with COPD used an electronic inhaler sensor for 12 weeks which recorded the date and time of each albuterol actuation. Self-reported COPD exacerbations and healthcare utilization were assessed monthly. We used generalized estimating equations with a logit link to compare the odds of an exacerbation day to a nonexacerbation day by the frequency of daily albuterol use. RESULTS:Average daily albuterol use on nonexacerbation days varied greatly between patients, ranging from 1.5 to 17.5 puffs. There were 48 exacerbation events observed in 29 participants during the study period, of which 16 were moderate-to-severe exacerbations. During the moderate-to-severe exacerbation days, the median value in average daily albuterol use increased by 14.1% (interquartile range: 2.7%-56.9%) compared to average nonexacerbation days. A 100% increase in inhaler use was associated with increased odds of a moderate-to severe exacerbation (odds ratio 1.54; 95% CI: 1.21-1.97). Approximately 74% of participants reported satisfaction with the sensor. CONCLUSIONS:The electronic inhaler sensor was well received in older patients with COPD over a 12-week period. Increased albuterol use captured by the device was associated with self-reported episodes of moderate-to-severe exacerbations.

authors

Sumino K,Locke ER,Magzamen S,Gylys-Colwell I,Humblet O,Nguyen HQ,Thomas RM,Fan VS

doi

10.1089/jamp.2017.1383

subject

Has Abstract

pub_date

2018-06-01 00:00:00

pages

191-198

issue

3

eissn

1941-2711

issn

1941-2703

journal_volume

31

pub_type

杂志文章
  • The Impact of Common Inhaler Errors on Drug Delivery: Investigating Critical Errors with a Dry Powder Inhaler.

    abstract:BACKGROUND:Researchers, using checklists, have identified that 30%-90% of patients make errors in inhaler use. It is not certain whether these errors affect the delivery of medication. We have developed an electronic monitor (INCA™) that records audio each time an inhaler is used, providing objective information on inh...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2016.1334

    authors: Sulaiman I,Seheult J,Sadasivuni N,MacHale E,Killane I,Giannoutsos S,Cushen B,Mokoka MC,Bhreathnach AS,Boland F,Reilly RB,Costello RW

    更新日期:2017-08-01 00:00:00

  • Collecting exhaled breath condensate (EBC) with two condensers in series: a promising technique for studying the mechanisms of EBC formation, and the volatility of selected biomarkers.

    abstract::Exhaled breath condensate (EBC) consists mainly of water, but also contains semivolatile and nonvolatile compounds. The aim of this study was to develop a system in which two condensers are simultaneously used in series to clarify the mechanisms of EBC condensation. Two aliquots of EBC (EBC1 and EBC2) were collected f...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2007.0644

    authors: Corradi M,Goldoni M,Caglieri A,Folesani G,Poli D,Corti M,Mutti A

    更新日期:2008-03-01 00:00:00

  • Spiromax, a New Dry Powder Inhaler: Dose Consistency under Simulated Real-World Conditions.

    abstract:BACKGROUND:Spiromax(®) is a novel dry powder inhaler for patients with asthma or chronic obstructive pulmonary disease (COPD). The studies presented here provide further data on attributes (in vitro dosing consistency with budesonide-formoterol (DuoResp) Spiromax; flow rates through empty versions of the Spiromax and T...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1216

    authors: Canonica GW,Arp J,Keegstra JR,Chrystyn H

    更新日期:2015-10-01 00:00:00

  • Deposition Mechanisms.

    abstract::The success of inhalation therapy is not only dependent upon the pharmacology of the drugs being inhaled but also upon the site and extent of deposition in the respiratory tract. Similarly, the toxicity of environmental and industrial particulate matter is affected not only by the nature of the dust but also by the am...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.29029.cd

    authors: Darquenne C

    更新日期:2020-08-01 00:00:00

  • Factors Determining In Vitro Lung Deposition of Albuterol Aerosol Delivered by Ventolin Metered-Dose Inhaler.

    abstract:BACKGROUND:The effectiveness of metered-dose inhalers (MDIs) in delivering medication to the lungs highly depends on its correct usage technique. Current guidelines state optimal technique for high lung deposition should include a slow inhalation (>5 seconds) at an inspiratory flow rate of 30 L/min and inhaler actuatio...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1278

    authors: Biswas R,Hanania NA,Sabharwal A

    更新日期:2017-08-01 00:00:00

  • Adapting the Abbreviated Impactor Measurement (AIM) concept to make appropriate inhaler aerosol measurements to compare with clinical data: a scoping study with the "Alberta" idealized throat (AIT) inlet.

    abstract:BACKGROUND:The Abbreviated Impactor Measurement (AIM) concept simplifies determination of aerodynamic size metrics for inhaler quality control testing. A similar approach is needed to compare in vitro particle size distribution metrics with human respiratory tract (HRT) deposition. METHODS:An abbreviated impactor base...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2011.0925

    authors: Mitchell J,Copley M,Sizer Y,Russell T,Solomon D

    更新日期:2012-08-01 00:00:00

  • Inhaled insulin: too soon to be forgotten?

    abstract::Inhalation is a potentially viable route of administration for numerous agents. In diabetes mellitus, the need for frequent injections to achieve ideal glycemic control remains a significant limitation for initiating and complying with insulin therapy in a large number of patients. To overcome this barrier, inhaled in...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2011.0876

    authors: Zarogoulidis P,Papanas N,Kouliatsis G,Spyratos D,Zarogoulidis K,Maltezos E

    更新日期:2011-10-01 00:00:00

  • Characterization of Medication Velocity and Size Distribution from Pressurized Metered-Dose Inhalers by Phase Doppler Anemometry.

    abstract:BACKGROUND:Particle size and velocity are two of the most significant factors that impact the deposition of pressurized metered-dose inhaler (pMDI) sprays in the mouth cavity. pMDIs are prominently used around the world in the treatment of patients suffering from a variety of lung diseases such as asthma and chronic ob...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1264

    authors: Alatrash A,Matida E

    更新日期:2016-12-01 00:00:00

  • Physiologically Based Pharmacokinetic/Pharmacodynamic Modeling Accurately Predicts the Better Bronchodilatory Effect of Inhaled Versus Oral Salbutamol Dosage Forms.

    abstract:BACKGROUND:Predicting local lung tissue pharmacodynamic (PD) responses of inhaled drugs is a longstanding challenge related to the lack of experimental techniques to determine local free drug concentrations. This has prompted the use of physiologically based pharmacokinetic (PBPK) modeling to potentially predict local ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1436

    authors: Boger E,Fridén M

    更新日期:2019-02-01 00:00:00

  • Pulmonary Toxicity of Benzalkonium Chloride.

    abstract::The available toxicity data of benzalkonium chloride (BKC) clearly shows that it is toxic; however, the weight of evidence favors the view that at doses encountered in nasally and orally inhaled pharmaceutical preparations it is well tolerated. The adverse toxicological data predominantly come from in vitro and animal...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2017.1390

    authors: Johnson NF

    更新日期:2018-02-01 00:00:00

  • Inhaled Antibiotic Therapy for the Treatment of Upper Respiratory Tract Infections.

    abstract::Upper respiratory tract infections (URTIs), primarily acute rhinopharyngitis, tonsillitis, adenoiditis, and rhinosinusitis (RS), are major causes of morbidity in both children and adults of any age. In addition to the frequent occurrence of related medical problems and the associated socioeconomic costs, URTIs have a ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2016.1300

    authors: Esposito S,Rosazza C,Sciarrabba CS,Principi N

    更新日期:2017-02-01 00:00:00

  • Vitamin A Supplementation by Endotracheal Application of a Nano-encapsulated Preparation Is Feasible in Ventilated Preterm Lambs.

    abstract:BACKGROUND:Vitamin A (VA) is crucial for lung growth and development. In premature infants, inadequate VA levels are associated with an increased risk of bronchopulmonary dysplasia (BPD). Intramuscular VA supplementation has been shown to decrease the incidence of BPD, but is not widely used in the clinical setting due...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1438

    authors: Wahl HB,Hütten MC,Monz D,Tutdibi E,Ophelders D,Nikiforou M,Tschernig T,Gortner L,Nohr D,Biesalski HK,Kramer BW

    更新日期:2018-12-01 00:00:00

  • In vitro characterization of the OptiChamber Diamond valved holding chamber.

    abstract:BACKGROUND:Use of a valved holding chamber (VHC) in conjunction with a pressurized metered dose inhaler (pMDI) can reduce issues relating to poor actuation-inhalation coordination and potentially improve the lung deposition of aerosol, compared with use of a pMDI alone. However, the performance of a VHC is influenced b...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2013.1067

    authors: Hatley RH,von Hollen D,Sandell D,Slator L

    更新日期:2014-08-01 00:00:00

  • Investigation of Lung Pharmacokinetic of the Novel PDE4 Inhibitor CHF6001 in Preclinical Models: Evaluation of the PreciseInhale Technology.

    abstract:BACKGROUND:Preclinical evaluation of new chemical entities (NCEs) designed to be administered by inhalation route requires lung administration to rodents, especially in the discovery phase. Different administration methods have been used until now, but more efforts are required to obtain controlled and reproducible lun...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1369

    authors: Fioni A,Selg E,Cenacchi V,Acevedo F,Brogin G,Gerde P,Puccini P

    更新日期:2018-02-01 00:00:00

  • Decreased level of PDCD4 (programmed cell death 4) protein activated cell proliferation in the lung of A/J mouse.

    abstract:BACKGROUND:Programmed cell death 4 (PDCD4), a protein that binds to eukaryotic initiation factor 4A (eIF4A), inhibits the initiation of translation. Although a number of tumor suppressors target transcription, Pdcd4 is the first suppressor targeting protein translation, and has also been suggested to function as a tumo...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2009.0778

    authors: Hwang SK,Minai-Tehrani A,Lim HT,Shin JY,An GH,Lee KH,Park KR,Kim YS,Beck GR Jr,Yang HS,Cho MH

    更新日期:2010-10-01 00:00:00

  • Evaluation of the Respimat Soft Mist Inhaler using a concurrent CFD and in vitro approach.

    abstract:BACKGROUND:The Respimat Soft Mist Inhaler is reported to generate an aerosol with low spray momentum and a small droplet size. However, the transport characteristics of the Respimat aerosol are not well understood. The objective of this study was to characterize the transport and deposition of an aerosol emitted from t...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0708

    authors: Worth Longest P,Hindle M

    更新日期:2009-06-01 00:00:00

  • Adapting the Aerogen Mesh Nebulizer for Dried Aerosol Exposures Using the PreciseInhale Platform.

    abstract:: Background: Many substances used in inhalation research are water soluble and can be administered as nebulized solutions. Typical examples are therapeutic, small-molecular agents, or macromolecules. Another category is a number of water-soluble agents used for airway diagn...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2019.1554

    authors: Gerde P,Nowenwik M,Sjöberg CO,Selg E

    更新日期:2020-04-01 00:00:00

  • Sustained mechanical and clinical functionality of the flexhaler dry powder inhaler.

    abstract::Flexhaler is a multiple-dose, inspiratory flow-driven dry powder inhaler that is a newer version of Turbuhaler, and is identical to the Symbicort Turbuhaler. Sustained performance is of the utmost importance to ensure consistent drug delivery throughout the lifespan of the inhaler. We report functionality testing resu...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0700

    authors: Lööf T,Elfman P,Ström P,Törngren A,Borgström L

    更新日期:2008-12-01 00:00:00

  • Community Masks During the SARS-CoV-2 Pandemic: Filtration Efficacy and Air Resistance.

    abstract:: Background: Many countries have introduced a compulsory use of community masks for certain public areas during the SARS-CoV-2 pandemic. Different manufacturers offer reusable community masks in large quantities. The efficacy of these masks, however, is unknown. ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.1635

    authors: Maurer L,Peris D,Kerl J,Guenther F,Koehler D,Dellweg D

    更新日期:2020-09-23 00:00:00

  • Aerosolizing Lipid Dispersions Enables Antibiotic Transport Across Mimics of the Lung Airway Surface Even in the Presence of Pre-existing Lipid Monolayers.

    abstract:BACKGROUND:Secondary lung infections are the primary cause of morbidity associated with cystic fibrosis lung disease. Aerosolized antibiotic inhalation is potentially advantageous but has limited effectiveness due to altered airway aerodynamics and deposition patterns that limit drug access to infected regions. One pot...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1412

    authors: Iasella SV,Stetten AZ,Corcoran TE,Garoff S,Przybycien TM,Tilton RD

    更新日期:2018-08-01 00:00:00

  • Model Calculations of Regional Deposition and Disposition for Single Doses of Inhaled Liposomal and Dry Powder Ciprofloxacin.

    abstract:BACKGROUND:Model predictions of regional deposition in the respiratory tract are useful in assessing factors that influence the effectiveness of aerosol delivery. Regional deposition models have previously been coupled with models of mucous production and clearance to estimate initial concentrations of drug deposited i...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1377

    authors: Martin AR,Finlay WH

    更新日期:2018-02-01 00:00:00

  • Validation of the 'Test of the Adherence to Inhalers' (TAI) for Asthma and COPD Patients.

    abstract:BACKGROUND:To validate the 'Test of Adherence to Inhalers' (TAI), a 12-item questionnaire designed to assess the adherence to inhalers in patients with COPD or asthma. METHODS:A total of 1009 patients with asthma or COPD participated in a cross-sectional multicenter study. Patients with electronic adherence ≥80% were ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,多中心研究

    doi:10.1089/jamp.2015.1212

    authors: Plaza V,Fernández-Rodríguez C,Melero C,Cosío BG,Entrenas LM,de Llano LP,Gutiérrez-Pereyra F,Tarragona E,Palomino R,López-Viña A,TAI Study Group.

    更新日期:2016-04-01 00:00:00

  • The I-neb Adaptive Aerosol Delivery System enhances delivery of alpha1-antitrypsin with controlled inhalation.

    abstract:BACKGROUND:Inhaled alpha1-antitrypsin (AAT) is being developed for treatment of cystic fibrosis to protect the lungs from excessive free elastase. High drug costs mandate a very efficient aerosol system to deliver a high payload to the airways. The I-neb Adaptive Aerosol Delivery (AAD) System is a portable, electronic,...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2009.0793

    authors: Geller DE,Kesser KC

    更新日期:2010-04-01 00:00:00

  • An Apparatus to Deliver Mannitol Powder for Bronchial Provocation in Children Under Six Years Old.

    abstract:BACKGROUND:Currently bronchial provocation testing (BPT) using mannitol powder cannot be performed in children under 6 years. A primary reason is it is challenging for children at this age to generate a consistent inspiratory effort to inhale mannitol efficiently from a dry powder inhaler. A prototype system, which doe...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1208

    authors: Tang P,Leung SS,Hor E,Ruzycki CA,Carrigy NB,Finlay WH,Brannan JD,Devadason S,Anderson SD,Sly PD,Samnick K,Chan HK

    更新日期:2015-12-01 00:00:00

  • A Computational Study of Nasal Spray Deposition Pattern in Four Ethnic Groups.

    abstract:BACKGROUND:Very little is known about the role of nasal morphology due to ethnic variation on particle deposition pattern in the sinonasal cavity. This preliminary study utilizes computational fluid dynamics (CFD) modeling to investigate sinonasal airway morphology and deposition patterns of intranasal sprayed particle...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1205

    authors: Keeler JA,Patki A,Woodard CR,Frank-Ito DO

    更新日期:2016-04-01 00:00:00

  • Physicochemical and Pharmacokinetic Evaluation of Spray-Dried Coformulation of Salvia miltiorrhiza Polyphenolic Acid and L-Leucine with Improved Bioavailability.

    abstract:: Background: Salvia miltiorrhiza polyphenolic acid (SMPA) is effective in the treatment of cardiovascular diseases and currently it is administered orally or intravenously. However, SMPA is poorly absorbed orally and quickly eliminated in vivo. A long-term frequent intraveno...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2019.1538

    authors: Lu P,Xing Y,Peng H,Liu Z,Zhou QT,Xue Z,Ma Z,Kebebe D,Zhang B,Liu H

    更新日期:2020-04-01 00:00:00

  • Evaluation of comparative performance of orally inhaled drug products in view of the classical bioequivalence paradigms: an analysis of the current scientific and regulatory dilemmas of inhaler evaluation.

    abstract::Since the early 1960s, there has been a continuous evolution in scientific understanding regarding bioequivalence (BE) of oral dosage forms, intermittently punctuated by some breakthrough research findings and conceptual advances. The accumulated knowledge from this body of research has been translated into a sophisti...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2014.1144

    authors: Horhota ST

    更新日期:2014-12-01 00:00:00

  • Controlled, Parametric, Individualized, 2-D and 3-D Imaging Measurements of Aerosol Deposition in the Respiratory Tract of Asthmatic Human Subjects for Model Validation.

    abstract:BACKGROUND:Computer modeling is used to predict inhaled aerosol deposition in the lung based on definition of the aerosol characteristics and the breathing pattern and airway anatomy of the subject. Validation of the models is limited by the lack of detailed experimental data. Three-dimensional imaging provides an oppo...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1191

    authors: Fleming J,Conway J,Majoral C,Katz I,Caillibotte G,Pichelin M,Montesantos S,Bennett M

    更新日期:2015-12-01 00:00:00

  • The co-imaging of gamma camera measurements of aerosol deposition and respiratory anatomy.

    abstract::The use of gamma camera imaging following the inhalation of a radiolabel has been widely used by researchers to investigate the fate of inhaled aerosols. The application of two-dimensional (2D) planar gamma scintigraphy and single-photon emission computed tomography (SPECT) to the study of inhaled aerosols is discusse...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2011.0960

    authors: Conway J,Fleming J,Bennett M,Havelock T

    更新日期:2013-06-01 00:00:00

  • Correcting Photo Reflection Method Output and Its Application in the Dynamic Analysis of Particle Release from Dry Powder Inhalers.

    abstract:: Background: The photo reflection method (PRM) is used to measure light reflected from particles released from dry powder inhalers (DPIs). This simple method depicts time trajectories of released drugs; however, it underestimates the number of particles at high peak inhalat...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.1610

    authors: Kondo T,Hibino M,Tanigaki T,Tajiri S,Horiuchi S

    更新日期:2020-11-04 00:00:00