An Apparatus to Deliver Mannitol Powder for Bronchial Provocation in Children Under Six Years Old.

Abstract:

BACKGROUND:Currently bronchial provocation testing (BPT) using mannitol powder cannot be performed in children under 6 years. A primary reason is it is challenging for children at this age to generate a consistent inspiratory effort to inhale mannitol efficiently from a dry powder inhaler. A prototype system, which does not require any inhalation training from the pediatric subject, is reported here. It uses an external source of compressed air to disperse mannitol powder into a commercial holding chamber. Then the subject uses tidal breathing to inhale the aerosol. METHOD:The setup consists of a commercially available powder disperser and Volumatic™ holding chamber. Taguchi experimental design was used to identify the effect of dispersion parameters (flow rate of compressed air, time compressed air is applied, mass of powder, and the time between dispersion and inhalation) on the fine particle dose (FPD). The prototype was tested in vitro using a USP throat connected to a next generation impactor. The aerosols from the holding chamber were drawn at 10 L/min. A scaling factor for estimating the provoking dose to induce a 15% reduction in forced expiratory volume in 1 second (FEV1) (PD15) was calculated using anatomical dimensions of the human respiratory tract at various ages combined with known dosing values from the adult BPT. RESULTS:Consistent and doubling FPDs were successfully generated based on the Taguchi experimental design. The FPD was reliable over a range of 0.8 (±0.09) mg to 14 (±0.94) mg. The calculated PD15 for children aged 1-6 years ranged from 7.1-30 mg. The FPDs generated from the proposed set up are lower than the calculated PD15 and therefore are not expected to cause sudden bronchoconstriction. CONCLUSION:A prototype aerosol delivery system has been developed that is consistently able to deliver doubling doses suitable for bronchial provocation testing in young children.

authors

Tang P,Leung SS,Hor E,Ruzycki CA,Carrigy NB,Finlay WH,Brannan JD,Devadason S,Anderson SD,Sly PD,Samnick K,Chan HK

doi

10.1089/jamp.2015.1208

subject

Has Abstract

pub_date

2015-12-01 00:00:00

pages

452-61

issue

6

eissn

1941-2711

issn

1941-2703

journal_volume

28

pub_type

杂志文章
  • Factors Determining In Vitro Lung Deposition of Albuterol Aerosol Delivered by Ventolin Metered-Dose Inhaler.

    abstract:BACKGROUND:The effectiveness of metered-dose inhalers (MDIs) in delivering medication to the lungs highly depends on its correct usage technique. Current guidelines state optimal technique for high lung deposition should include a slow inhalation (>5 seconds) at an inspiratory flow rate of 30 L/min and inhaler actuatio...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1278

    authors: Biswas R,Hanania NA,Sabharwal A

    更新日期:2017-08-01 00:00:00

  • Development of an in vitro model to assess deposition of aerosol particles in a representative replica of the rat's respiratory tract.

    abstract:BACKGROUND:Small rodents continue to be the mainstay for the assessment of pharmacological and toxicological data of inhaled therapeutics. For meaningful interpretation of the results information about deposition of aerosol particles in the respiratory tract is warranted, but not trivial to obtain for animals with nose...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2011.0902

    authors: Ahmed A,Prime D,Burnell PK,Högger P

    更新日期:2012-06-01 00:00:00

  • Evaluation of the Respimat Soft Mist Inhaler using a concurrent CFD and in vitro approach.

    abstract:BACKGROUND:The Respimat Soft Mist Inhaler is reported to generate an aerosol with low spray momentum and a small droplet size. However, the transport characteristics of the Respimat aerosol are not well understood. The objective of this study was to characterize the transport and deposition of an aerosol emitted from t...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0708

    authors: Worth Longest P,Hindle M

    更新日期:2009-06-01 00:00:00

  • Aerosol Therapy in Adults Receiving High Flow Nasal Cannula Oxygen Therapy.

    abstract:BACKGROUND:High flow nasal cannula oxygen therapy (HFT) is increasingly used in intensive and emergency care departments. Patients suffering from respiratory failure, who are likely to benefit from HFT, may require aerosolized bronchodilators; therefore, combining nebulization with HFT may be relevant. This study aimed...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1219

    authors: Réminiac F,Vecellio L,Heuzé-Vourc'h N,Petitcollin A,Respaud R,Cabrera M,Pennec DL,Diot P,Ehrmann S

    更新日期:2016-04-01 00:00:00

  • Pulmonary Toxicity of Benzalkonium Chloride.

    abstract::The available toxicity data of benzalkonium chloride (BKC) clearly shows that it is toxic; however, the weight of evidence favors the view that at doses encountered in nasally and orally inhaled pharmaceutical preparations it is well tolerated. The adverse toxicological data predominantly come from in vitro and animal...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2017.1390

    authors: Johnson NF

    更新日期:2018-02-01 00:00:00

  • Characterization of Medication Velocity and Size Distribution from Pressurized Metered-Dose Inhalers by Phase Doppler Anemometry.

    abstract:BACKGROUND:Particle size and velocity are two of the most significant factors that impact the deposition of pressurized metered-dose inhaler (pMDI) sprays in the mouth cavity. pMDIs are prominently used around the world in the treatment of patients suffering from a variety of lung diseases such as asthma and chronic ob...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1264

    authors: Alatrash A,Matida E

    更新日期:2016-12-01 00:00:00

  • Inhaled Antibiotic Therapy for the Treatment of Upper Respiratory Tract Infections.

    abstract::Upper respiratory tract infections (URTIs), primarily acute rhinopharyngitis, tonsillitis, adenoiditis, and rhinosinusitis (RS), are major causes of morbidity in both children and adults of any age. In addition to the frequent occurrence of related medical problems and the associated socioeconomic costs, URTIs have a ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2016.1300

    authors: Esposito S,Rosazza C,Sciarrabba CS,Principi N

    更新日期:2017-02-01 00:00:00

  • Pulmonary formulations: what remains to be done?

    abstract::Significant advances have been made in the last 50 years in developing safe and efficacious aerosol formulations for pulmonary delivery. The key to future innovation may lie at the interface between biology and particle engineering. Improved understanding of biological processes including particle clearance, cellular ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2010.0838

    authors: Weers JG,Bell J,Chan HK,Cipolla D,Dunbar C,Hickey AJ,Smith IJ

    更新日期:2010-12-01 00:00:00

  • A Computational Study of Nasal Spray Deposition Pattern in Four Ethnic Groups.

    abstract:BACKGROUND:Very little is known about the role of nasal morphology due to ethnic variation on particle deposition pattern in the sinonasal cavity. This preliminary study utilizes computational fluid dynamics (CFD) modeling to investigate sinonasal airway morphology and deposition patterns of intranasal sprayed particle...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1205

    authors: Keeler JA,Patki A,Woodard CR,Frank-Ito DO

    更新日期:2016-04-01 00:00:00

  • The co-imaging of gamma camera measurements of aerosol deposition and respiratory anatomy.

    abstract::The use of gamma camera imaging following the inhalation of a radiolabel has been widely used by researchers to investigate the fate of inhaled aerosols. The application of two-dimensional (2D) planar gamma scintigraphy and single-photon emission computed tomography (SPECT) to the study of inhaled aerosols is discusse...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2011.0960

    authors: Conway J,Fleming J,Bennett M,Havelock T

    更新日期:2013-06-01 00:00:00

  • The effects of training on inhaler technique and quality of life in patients with COPD.

    abstract:OBJECTIVES:This experimental study was conducted to determine the effects of training on inhaler technique and quality of life in patients with chronic obstructive pulmonary disease (COPD). METHODS:Among the patients who applied at the outpatient clinic of chest diseases between March 2009 and May 2010, a total of 69 ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/jamp.2012.1017

    authors: Göriş S,Taşci S,Elmali F

    更新日期:2013-12-01 00:00:00

  • Optimal delivery of aerosols to infants during mechanical ventilation.

    abstract:PURPOSE:The objective of this study was to determine optimal aerosol delivery conditions for a full-term (3.6 kg) infant receiving invasive mechanical ventilation by evaluating the effects of aerosol particle size, a new wye connector, and timing of aerosol delivery. METHODS:In vitro experiments used a vibrating mesh ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2013.1077

    authors: Longest PW,Azimi M,Hindle M

    更新日期:2014-10-01 00:00:00

  • Community Masks During the SARS-CoV-2 Pandemic: Filtration Efficacy and Air Resistance.

    abstract:: Background: Many countries have introduced a compulsory use of community masks for certain public areas during the SARS-CoV-2 pandemic. Different manufacturers offer reusable community masks in large quantities. The efficacy of these masks, however, is unknown. ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.1635

    authors: Maurer L,Peris D,Kerl J,Guenther F,Koehler D,Dellweg D

    更新日期:2020-09-23 00:00:00

  • Age-dependent deterioration of peak inspiratory flow with two kinds of dry powder corticosteroid inhalers (Diskus and Turbuhaler) and relationships with asthma control.

    abstract:BACKGROUND:Inhaled corticosteroid (ICS) therapy has improved the quality of life (QOL) for many asthmatics and reduced mortality rates associated with asthma. However, some patients do not obtain therapeutic benefit despite satisfactory adherence. OBJECTIVES:To determine whether asthmatic patients were using ICS devic...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2010.0868

    authors: Baba K,Tanaka H,Nishimura M,Yokoe N,Takahashi D,Yagi T,Yamaguchi E,Maeda Y,Muto T,Hasegawa T

    更新日期:2011-12-01 00:00:00

  • Assessment of the Power Required for Optimal Use of Current Inhalation Devices.

    abstract:: Background: Inhalation of medications is the cornerstone in the treatment of patients with lung diseases. A variety of inhalation devices exists and each device has specific requirements to achieve optimum inhalation of the drug. The goal of this study was to establish a c...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1376

    authors: Pohlmann G,Hohlfeld JM,Haidl P,Pankalla J,Cloes RM

    更新日期:2018-12-01 00:00:00

  • Validation of the 'Test of the Adherence to Inhalers' (TAI) for Asthma and COPD Patients.

    abstract:BACKGROUND:To validate the 'Test of Adherence to Inhalers' (TAI), a 12-item questionnaire designed to assess the adherence to inhalers in patients with COPD or asthma. METHODS:A total of 1009 patients with asthma or COPD participated in a cross-sectional multicenter study. Patients with electronic adherence ≥80% were ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,多中心研究

    doi:10.1089/jamp.2015.1212

    authors: Plaza V,Fernández-Rodríguez C,Melero C,Cosío BG,Entrenas LM,de Llano LP,Gutiérrez-Pereyra F,Tarragona E,Palomino R,López-Viña A,TAI Study Group.

    更新日期:2016-04-01 00:00:00

  • Nebulized medications for the treatment of dyspnea: a literature review.

    abstract:BACKGROUND:Dyspnea significantly impacts quality of life and is one of the most common symptoms in advanced illness. Systemically-administered opioids and benzodiazepines have been the most studied and utilized pharmacologic treatments for refractory dyspnea. Less attention has been given to the use of these medication...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2014.1136

    authors: Boyden JY,Connor SR,Otolorin L,Nathan SD,Fine PG,Davis MS,Muir JC

    更新日期:2015-02-01 00:00:00

  • Physicochemical and Pharmacokinetic Evaluation of Spray-Dried Coformulation of Salvia miltiorrhiza Polyphenolic Acid and L-Leucine with Improved Bioavailability.

    abstract:: Background: Salvia miltiorrhiza polyphenolic acid (SMPA) is effective in the treatment of cardiovascular diseases and currently it is administered orally or intravenously. However, SMPA is poorly absorbed orally and quickly eliminated in vivo. A long-term frequent intraveno...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2019.1538

    authors: Lu P,Xing Y,Peng H,Liu Z,Zhou QT,Xue Z,Ma Z,Kebebe D,Zhang B,Liu H

    更新日期:2020-04-01 00:00:00

  • Collecting exhaled breath condensate (EBC) with two condensers in series: a promising technique for studying the mechanisms of EBC formation, and the volatility of selected biomarkers.

    abstract::Exhaled breath condensate (EBC) consists mainly of water, but also contains semivolatile and nonvolatile compounds. The aim of this study was to develop a system in which two condensers are simultaneously used in series to clarify the mechanisms of EBC condensation. Two aliquots of EBC (EBC1 and EBC2) were collected f...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2007.0644

    authors: Corradi M,Goldoni M,Caglieri A,Folesani G,Poli D,Corti M,Mutti A

    更新日期:2008-03-01 00:00:00

  • Evaluation of comparative performance of orally inhaled drug products in view of the classical bioequivalence paradigms: an analysis of the current scientific and regulatory dilemmas of inhaler evaluation.

    abstract::Since the early 1960s, there has been a continuous evolution in scientific understanding regarding bioequivalence (BE) of oral dosage forms, intermittently punctuated by some breakthrough research findings and conceptual advances. The accumulated knowledge from this body of research has been translated into a sophisti...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2014.1144

    authors: Horhota ST

    更新日期:2014-12-01 00:00:00

  • Inhaled insulin: too soon to be forgotten?

    abstract::Inhalation is a potentially viable route of administration for numerous agents. In diabetes mellitus, the need for frequent injections to achieve ideal glycemic control remains a significant limitation for initiating and complying with insulin therapy in a large number of patients. To overcome this barrier, inhaled in...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2011.0876

    authors: Zarogoulidis P,Papanas N,Kouliatsis G,Spyratos D,Zarogoulidis K,Maltezos E

    更新日期:2011-10-01 00:00:00

  • Controlled, Parametric, Individualized, 2-D and 3-D Imaging Measurements of Aerosol Deposition in the Respiratory Tract of Asthmatic Human Subjects for Model Validation.

    abstract:BACKGROUND:Computer modeling is used to predict inhaled aerosol deposition in the lung based on definition of the aerosol characteristics and the breathing pattern and airway anatomy of the subject. Validation of the models is limited by the lack of detailed experimental data. Three-dimensional imaging provides an oppo...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1191

    authors: Fleming J,Conway J,Majoral C,Katz I,Caillibotte G,Pichelin M,Montesantos S,Bennett M

    更新日期:2015-12-01 00:00:00

  • Intranasal Deposition of Accuspray™ Aerosol in Anatomically Correct Models of 2-, 5-, and 12-Year-Old Children.

    abstract:BACKGROUND:To our knowledge, quantification of intranasal deposition of aerosol generated by Accuspray(™) (AS) in children has never been published. We hypothesized that deposition would vary significantly with age and with placement of the device within, or outside, of the nostril. METHODS:We tested these hypotheses ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1174

    authors: Laube BL,Sharpless G,Vikani AR,Harrand V,Zinreich SJ,Sedberry K,Knaus D,Barry J,Papania M

    更新日期:2015-10-01 00:00:00

  • Targeting aerosolized drugs to the conducting airways using very large particles and extremely slow inhalations.

    abstract:BACKGROUND:The site of deposition in the respiratory tract for aerosolized, inhaled therapeutic drugs depends on both the particles' aerodynamic size and the patient's breathing pattern. METHODS:In 21 healthy subjects with normal lung function, we evaluated an extremely slow inhalation of a large 9.5-μm MMAD particle ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0711

    authors: Zeman KL,Wu J,Bennett WD

    更新日期:2010-12-01 00:00:00

  • The Impact of Common Inhaler Errors on Drug Delivery: Investigating Critical Errors with a Dry Powder Inhaler.

    abstract:BACKGROUND:Researchers, using checklists, have identified that 30%-90% of patients make errors in inhaler use. It is not certain whether these errors affect the delivery of medication. We have developed an electronic monitor (INCA™) that records audio each time an inhaler is used, providing objective information on inh...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2016.1334

    authors: Sulaiman I,Seheult J,Sadasivuni N,MacHale E,Killane I,Giannoutsos S,Cushen B,Mokoka MC,Bhreathnach AS,Boland F,Reilly RB,Costello RW

    更新日期:2017-08-01 00:00:00

  • In vitro characterization of the OptiChamber Diamond valved holding chamber.

    abstract:BACKGROUND:Use of a valved holding chamber (VHC) in conjunction with a pressurized metered dose inhaler (pMDI) can reduce issues relating to poor actuation-inhalation coordination and potentially improve the lung deposition of aerosol, compared with use of a pMDI alone. However, the performance of a VHC is influenced b...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2013.1067

    authors: Hatley RH,von Hollen D,Sandell D,Slator L

    更新日期:2014-08-01 00:00:00

  • Spiromax, a New Dry Powder Inhaler: Dose Consistency under Simulated Real-World Conditions.

    abstract:BACKGROUND:Spiromax(®) is a novel dry powder inhaler for patients with asthma or chronic obstructive pulmonary disease (COPD). The studies presented here provide further data on attributes (in vitro dosing consistency with budesonide-formoterol (DuoResp) Spiromax; flow rates through empty versions of the Spiromax and T...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1216

    authors: Canonica GW,Arp J,Keegstra JR,Chrystyn H

    更新日期:2015-10-01 00:00:00

  • Adapting the Abbreviated Impactor Measurement (AIM) concept to make appropriate inhaler aerosol measurements to compare with clinical data: a scoping study with the "Alberta" idealized throat (AIT) inlet.

    abstract:BACKGROUND:The Abbreviated Impactor Measurement (AIM) concept simplifies determination of aerodynamic size metrics for inhaler quality control testing. A similar approach is needed to compare in vitro particle size distribution metrics with human respiratory tract (HRT) deposition. METHODS:An abbreviated impactor base...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2011.0925

    authors: Mitchell J,Copley M,Sizer Y,Russell T,Solomon D

    更新日期:2012-08-01 00:00:00

  • Model Calculations of Regional Deposition and Disposition for Single Doses of Inhaled Liposomal and Dry Powder Ciprofloxacin.

    abstract:BACKGROUND:Model predictions of regional deposition in the respiratory tract are useful in assessing factors that influence the effectiveness of aerosol delivery. Regional deposition models have previously been coupled with models of mucous production and clearance to estimate initial concentrations of drug deposited i...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1377

    authors: Martin AR,Finlay WH

    更新日期:2018-02-01 00:00:00

  • Sustained mechanical and clinical functionality of the flexhaler dry powder inhaler.

    abstract::Flexhaler is a multiple-dose, inspiratory flow-driven dry powder inhaler that is a newer version of Turbuhaler, and is identical to the Symbicort Turbuhaler. Sustained performance is of the utmost importance to ensure consistent drug delivery throughout the lifespan of the inhaler. We report functionality testing resu...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0700

    authors: Lööf T,Elfman P,Ström P,Törngren A,Borgström L

    更新日期:2008-12-01 00:00:00