Abstract:
BACKGROUND:Understanding the regional partition of deposition of inhaled particles within the lung is important for improving targeted delivery of inhaled aerosolized drugs. One factor affecting regional deposition is gravity. As the lung deforms under its own weight, changes in lung volume, in airway geometries, and in spatial patterns of ventilation distribution between postures have the potential to alter the regional distribution of deposited particles. METHODS:Using gamma-scintigraphy, we measured regional deposition and clearance of (99m)Tc labeled particles (5 μm) in 6 healthy subjects, with aerosol inhalation occurring both in the supine and seated postures at constant flow (0.5 L/sec) and breathing rate (15 breaths/min). After aerosol deposition, mucociliary clearance data were collected in the seated posture, immediately post-particle administration, 1 h 30 min, 4 h, and 22 h post-inhalation. Relative regional deposition was computed using retention (R) at the different time points, with (1-R(1h30min)), (R(1h30min)- R(4h)), and (R(4h)- R(22h)) corresponding to deposition in the large, intermediate, and small airways, respectively. Alveolar deposition was estimated as the relative retention at 22 h (R(22h)). RESULTS:Relative deposition of coarse particles in the alveolar region decreased from 60±8% seated to 34±16% supine (p=0.04). This change was accompanied by an increase in relative deposition in the intermediate (7±3% seated to 16±17% supine, P=0.09) and small airways (19±6% seated to 34±13% supine, p=0.06) when inhalation occurred in the supine posture. No change was observed in central to peripheral deposition (C/P ratio), the skew of the deposition distribution, or the apex-to-base ratio of deposition between seated and supine postures. CONCLUSIONS:Inhalation of coarse particles in the supine posture shifts relative deposition from the alveolar to the bronchial airways, when compared to the seated posture, likely driven by changes in functional residual capacity, and airway size, as well as changes in the regional distribution of ventilation between postures.
journal_name
J Aerosol Med Pulm Drug Delivjournal_title
Journal of aerosol medicine and pulmonary drug deliveryauthors
Sá RC,Zeman KL,Bennett WD,Prisk GK,Darquenne Cdoi
10.1089/jamp.2014.1189subject
Has Abstractpub_date
2015-12-01 00:00:00pages
423-31issue
6eissn
1941-2711issn
1941-2703journal_volume
28pub_type
杂志文章abstract:: Background: Many countries have introduced a compulsory use of community masks for certain public areas during the SARS-CoV-2 pandemic. Different manufacturers offer reusable community masks in large quantities. The efficacy of these masks, however, is unknown. ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2020.1635
更新日期:2020-09-23 00:00:00
abstract:BACKGROUND:The effectiveness of metered-dose inhalers (MDIs) in delivering medication to the lungs highly depends on its correct usage technique. Current guidelines state optimal technique for high lung deposition should include a slow inhalation (>5 seconds) at an inspiratory flow rate of 30 L/min and inhaler actuatio...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2015.1278
更新日期:2017-08-01 00:00:00
abstract:BACKGROUND:Inhaled atropine is being developed as a systemic and pulmonary treatment for the extended recovery period after chemical weapons exposure. We performed a pharmacokinetics study comparing inhaled atropine delivery using the MicroDose Therapeutx Dry Powder Inhaler (DPIA) with intramuscular (IM) atropine deliv...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,随机对照试验
doi:10.1089/jamp.2011.0948
更新日期:2013-02-01 00:00:00
abstract::Inhalation is a potentially viable route of administration for numerous agents. In diabetes mellitus, the need for frequent injections to achieve ideal glycemic control remains a significant limitation for initiating and complying with insulin therapy in a large number of patients. To overcome this barrier, inhaled in...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,评审
doi:10.1089/jamp.2011.0876
更新日期:2011-10-01 00:00:00
abstract::Flexhaler is a multiple-dose, inspiratory flow-driven dry powder inhaler that is a newer version of Turbuhaler, and is identical to the Symbicort Turbuhaler. Sustained performance is of the utmost importance to ensure consistent drug delivery throughout the lifespan of the inhaler. We report functionality testing resu...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2008.0700
更新日期:2008-12-01 00:00:00
abstract:BACKGROUND:High flow nasal cannula oxygen therapy (HFT) is increasingly used in intensive and emergency care departments. Patients suffering from respiratory failure, who are likely to benefit from HFT, may require aerosolized bronchodilators; therefore, combining nebulization with HFT may be relevant. This study aimed...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2015.1219
更新日期:2016-04-01 00:00:00
abstract:: Background: Salvia miltiorrhiza polyphenolic acid (SMPA) is effective in the treatment of cardiovascular diseases and currently it is administered orally or intravenously. However, SMPA is poorly absorbed orally and quickly eliminated in vivo. A long-term frequent intraveno...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2019.1538
更新日期:2020-04-01 00:00:00
abstract:BACKGROUND:Predicting local lung tissue pharmacodynamic (PD) responses of inhaled drugs is a longstanding challenge related to the lack of experimental techniques to determine local free drug concentrations. This has prompted the use of physiologically based pharmacokinetic (PBPK) modeling to potentially predict local ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2017.1436
更新日期:2019-02-01 00:00:00
abstract:BACKGROUND:Computer modeling is used to predict inhaled aerosol deposition in the lung based on definition of the aerosol characteristics and the breathing pattern and airway anatomy of the subject. Validation of the models is limited by the lack of detailed experimental data. Three-dimensional imaging provides an oppo...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2014.1191
更新日期:2015-12-01 00:00:00
abstract:BACKGROUND:Spiromax(®) is a novel dry powder inhaler for patients with asthma or chronic obstructive pulmonary disease (COPD). The studies presented here provide further data on attributes (in vitro dosing consistency with budesonide-formoterol (DuoResp) Spiromax; flow rates through empty versions of the Spiromax and T...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2015.1216
更新日期:2015-10-01 00:00:00
abstract:BACKGROUND:The delivery of antitubercular drugs through direct lung targeting can lead to reduction in the dose as well as side effects of the drug. In the present investigation, carrier (lactose)-based dry-powder inhaler of rifampicin was prepared to achieve direct targeting of the drug into the lungs. METHODS:The dr...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2017.1379
更新日期:2017-12-01 00:00:00
abstract::Exhaled breath condensate (EBC) consists mainly of water, but also contains semivolatile and nonvolatile compounds. The aim of this study was to develop a system in which two condensers are simultaneously used in series to clarify the mechanisms of EBC condensation. Two aliquots of EBC (EBC1 and EBC2) were collected f...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2007.0644
更新日期:2008-03-01 00:00:00
abstract:PURPOSE:The objective of this study was to determine optimal aerosol delivery conditions for a full-term (3.6 kg) infant receiving invasive mechanical ventilation by evaluating the effects of aerosol particle size, a new wye connector, and timing of aerosol delivery. METHODS:In vitro experiments used a vibrating mesh ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2013.1077
更新日期:2014-10-01 00:00:00
abstract::The available toxicity data of benzalkonium chloride (BKC) clearly shows that it is toxic; however, the weight of evidence favors the view that at doses encountered in nasally and orally inhaled pharmaceutical preparations it is well tolerated. The adverse toxicological data predominantly come from in vitro and animal...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,评审
doi:10.1089/jamp.2017.1390
更新日期:2018-02-01 00:00:00
abstract:BACKGROUND:Very little is known about the role of nasal morphology due to ethnic variation on particle deposition pattern in the sinonasal cavity. This preliminary study utilizes computational fluid dynamics (CFD) modeling to investigate sinonasal airway morphology and deposition patterns of intranasal sprayed particle...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2014.1205
更新日期:2016-04-01 00:00:00
abstract:BACKGROUND:Currently bronchial provocation testing (BPT) using mannitol powder cannot be performed in children under 6 years. A primary reason is it is challenging for children at this age to generate a consistent inspiratory effort to inhale mannitol efficiently from a dry powder inhaler. A prototype system, which doe...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2015.1208
更新日期:2015-12-01 00:00:00
abstract:OBJECTIVES:This experimental study was conducted to determine the effects of training on inhaler technique and quality of life in patients with chronic obstructive pulmonary disease (COPD). METHODS:Among the patients who applied at the outpatient clinic of chest diseases between March 2009 and May 2010, a total of 69 ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,随机对照试验
doi:10.1089/jamp.2012.1017
更新日期:2013-12-01 00:00:00
abstract:BACKGROUND:Mechanically ventilated patients commonly suffer from ventilator-associated pneumonia, hypoxemia, and other lower respiratory tract infection as a result of pathogen colonization and poor sputum clearance. Consequently, there is a high rate of morbidity and mortality in these patients. Dry powder mannitol in...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2016.1320
更新日期:2017-04-01 00:00:00
abstract:BACKGROUND:Vitamin A (VA) is crucial for lung growth and development. In premature infants, inadequate VA levels are associated with an increased risk of bronchopulmonary dysplasia (BPD). Intramuscular VA supplementation has been shown to decrease the incidence of BPD, but is not widely used in the clinical setting due...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2017.1438
更新日期:2018-12-01 00:00:00
abstract::Significant advances have been made in the last 50 years in developing safe and efficacious aerosol formulations for pulmonary delivery. The key to future innovation may lie at the interface between biology and particle engineering. Improved understanding of biological processes including particle clearance, cellular ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,评审
doi:10.1089/jamp.2010.0838
更新日期:2010-12-01 00:00:00
abstract:BACKGROUND:Secondary lung infections are the primary cause of morbidity associated with cystic fibrosis lung disease. Aerosolized antibiotic inhalation is potentially advantageous but has limited effectiveness due to altered airway aerodynamics and deposition patterns that limit drug access to infected regions. One pot...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2017.1412
更新日期:2018-08-01 00:00:00
abstract:BACKGROUND:The Abbreviated Impactor Measurement (AIM) concept simplifies determination of aerodynamic size metrics for inhaler quality control testing. A similar approach is needed to compare in vitro particle size distribution metrics with human respiratory tract (HRT) deposition. METHODS:An abbreviated impactor base...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2011.0925
更新日期:2012-08-01 00:00:00
abstract:BACKGROUND:To validate the 'Test of Adherence to Inhalers' (TAI), a 12-item questionnaire designed to assess the adherence to inhalers in patients with COPD or asthma. METHODS:A total of 1009 patients with asthma or COPD participated in a cross-sectional multicenter study. Patients with electronic adherence ≥80% were ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,多中心研究
doi:10.1089/jamp.2015.1212
更新日期:2016-04-01 00:00:00
abstract:PURPOSE:Many methods have been developed to evaluate dry powder inhalation techniques and their efficiency for disease control in asthma patients. However, it is difficult to apply these methods to clinical practice and research. In this study, we introduce a simple new method that can be applied to dry powder inhalati...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2014.1193
更新日期:2016-10-01 00:00:00
abstract:BACKGROUND:Preclinical evaluation of new chemical entities (NCEs) designed to be administered by inhalation route requires lung administration to rodents, especially in the discovery phase. Different administration methods have been used until now, but more efforts are required to obtain controlled and reproducible lun...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2017.1369
更新日期:2018-02-01 00:00:00
abstract:BACKGROUND:Programmed cell death 4 (PDCD4), a protein that binds to eukaryotic initiation factor 4A (eIF4A), inhibits the initiation of translation. Although a number of tumor suppressors target transcription, Pdcd4 is the first suppressor targeting protein translation, and has also been suggested to function as a tumo...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2009.0778
更新日期:2010-10-01 00:00:00
abstract::Upper respiratory tract infections (URTIs), primarily acute rhinopharyngitis, tonsillitis, adenoiditis, and rhinosinusitis (RS), are major causes of morbidity in both children and adults of any age. In addition to the frequent occurrence of related medical problems and the associated socioeconomic costs, URTIs have a ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,评审
doi:10.1089/jamp.2016.1300
更新日期:2017-02-01 00:00:00
abstract:: Background: The photo reflection method (PRM) is used to measure light reflected from particles released from dry powder inhalers (DPIs). This simple method depicts time trajectories of released drugs; however, it underestimates the number of particles at high peak inhalat...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2020.1610
更新日期:2020-11-04 00:00:00
abstract:: Background: Inhalation of medications is the cornerstone in the treatment of patients with lung diseases. A variety of inhalation devices exists and each device has specific requirements to achieve optimum inhalation of the drug. The goal of this study was to establish a c...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2017.1376
更新日期:2018-12-01 00:00:00
abstract:BACKGROUND:Model predictions of regional deposition in the respiratory tract are useful in assessing factors that influence the effectiveness of aerosol delivery. Regional deposition models have previously been coupled with models of mucous production and clearance to estimate initial concentrations of drug deposited i...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2017.1377
更新日期:2018-02-01 00:00:00