Abstract:
BACKGROUND:The effectiveness of metered-dose inhalers (MDIs) in delivering medication to the lungs highly depends on its correct usage technique. Current guidelines state optimal technique for high lung deposition should include a slow inhalation (>5 seconds) at an inspiratory flow rate of 30 L/min and inhaler actuation at the start of inhalation. However, these recommendations were based on clinical studies using CFC (chlorofluorocarbon)-MDIs and in vitro studies of HFA (hydrofluoroalkane)-MDIs using idealized MDI techniques of uniform inhalation and actuation, disregarding the nonuniform techniques of actual patients. METHODS:To better understand the effects of time-varying MDI usage parameters on lung deposition of aerosol delivered by an HFA-MDI, we conducted an in vitro study modeled on real-life variable inspiratory flow and actuation techniques recorded from 15 subjects with asthma/chronic obstructive pulmonary disease (COPD). We developed a model representing the time-varying inspiratory flow waveforms and actuation timings based on 43 MDI techniques recorded from patients. Furthermore, we constructed an in vitro experimental setup using a mouth-throat cast, programmable MDI actuator, and breath simulator to evaluate lung deposition for the MDI techniques derived from our model. RESULTS:High inspiratory flow rates, 60-90 L/min, consistently resulted in high in vitro lung deposition (>40%) of aerosol (albuterol delivered from Ventolin HFA-MDI) compared to 30 L/min when MDI actuation occurred in the first half of inhalation. Also, positive coordination resulted in higher in vitro lung deposition compared with negative or zero coordination (actuating before or at the start of inspiration). Furthermore, variation in coordination affected lung deposition more significantly (23%) than flow rate or duration of inspiration (≤5%). CONCLUSIONS:In an in vitro experimental model based on inhalation data from patients with asthma and COPD, we demonstrated that aerosol lung deposition emitted from Ventolin HFA-MDI is most optimal for MDI actuation in the first half of inspiration at high flow rates (60-90 L/min).
journal_name
J Aerosol Med Pulm Drug Delivjournal_title
Journal of aerosol medicine and pulmonary drug deliveryauthors
Biswas R,Hanania NA,Sabharwal Adoi
10.1089/jamp.2015.1278subject
Has Abstractpub_date
2017-08-01 00:00:00pages
256-266issue
4eissn
1941-2711issn
1941-2703journal_volume
30pub_type
杂志文章abstract:BACKGROUND:Dyspnea significantly impacts quality of life and is one of the most common symptoms in advanced illness. Systemically-administered opioids and benzodiazepines have been the most studied and utilized pharmacologic treatments for refractory dyspnea. Less attention has been given to the use of these medication...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,评审
doi:10.1089/jamp.2014.1136
更新日期:2015-02-01 00:00:00
abstract:: Background: Salvia miltiorrhiza polyphenolic acid (SMPA) is effective in the treatment of cardiovascular diseases and currently it is administered orally or intravenously. However, SMPA is poorly absorbed orally and quickly eliminated in vivo. A long-term frequent intraveno...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2019.1538
更新日期:2020-04-01 00:00:00
abstract:BACKGROUND:To our knowledge, quantification of intranasal deposition of aerosol generated by Accuspray(™) (AS) in children has never been published. We hypothesized that deposition would vary significantly with age and with placement of the device within, or outside, of the nostril. METHODS:We tested these hypotheses ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2014.1174
更新日期:2015-10-01 00:00:00
abstract::Upper respiratory tract infections (URTIs), primarily acute rhinopharyngitis, tonsillitis, adenoiditis, and rhinosinusitis (RS), are major causes of morbidity in both children and adults of any age. In addition to the frequent occurrence of related medical problems and the associated socioeconomic costs, URTIs have a ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,评审
doi:10.1089/jamp.2016.1300
更新日期:2017-02-01 00:00:00
abstract::The available toxicity data of benzalkonium chloride (BKC) clearly shows that it is toxic; however, the weight of evidence favors the view that at doses encountered in nasally and orally inhaled pharmaceutical preparations it is well tolerated. The adverse toxicological data predominantly come from in vitro and animal...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,评审
doi:10.1089/jamp.2017.1390
更新日期:2018-02-01 00:00:00
abstract::The present study aimed at assessing the pharmacokinetics (PK) and safety pharmacodynamics (PD) of 24 microg formoterol delivered via a Novolizer and via an Aerolizer in healthy subjects. This was a randomized, open-label, crossover study. Beside PK, serum potassium, and glucose profiles, vital signs, and ECG were rec...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,随机对照试验
doi:10.1089/jamp.2008.0690
更新日期:2008-09-01 00:00:00
abstract:PURPOSE:The objective of this study was to determine optimal aerosol delivery conditions for a full-term (3.6 kg) infant receiving invasive mechanical ventilation by evaluating the effects of aerosol particle size, a new wye connector, and timing of aerosol delivery. METHODS:In vitro experiments used a vibrating mesh ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2013.1077
更新日期:2014-10-01 00:00:00
abstract:PURPOSE:Many methods have been developed to evaluate dry powder inhalation techniques and their efficiency for disease control in asthma patients. However, it is difficult to apply these methods to clinical practice and research. In this study, we introduce a simple new method that can be applied to dry powder inhalati...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2014.1193
更新日期:2016-10-01 00:00:00
abstract:BACKGROUND:Inhaled corticosteroid (ICS) therapy has improved the quality of life (QOL) for many asthmatics and reduced mortality rates associated with asthma. However, some patients do not obtain therapeutic benefit despite satisfactory adherence. OBJECTIVES:To determine whether asthmatic patients were using ICS devic...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2010.0868
更新日期:2011-12-01 00:00:00
abstract:BACKGROUND:Understanding the regional partition of deposition of inhaled particles within the lung is important for improving targeted delivery of inhaled aerosolized drugs. One factor affecting regional deposition is gravity. As the lung deforms under its own weight, changes in lung volume, in airway geometries, and i...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2014.1189
更新日期:2015-12-01 00:00:00
abstract:BACKGROUND:Particle size and velocity are two of the most significant factors that impact the deposition of pressurized metered-dose inhaler (pMDI) sprays in the mouth cavity. pMDIs are prominently used around the world in the treatment of patients suffering from a variety of lung diseases such as asthma and chronic ob...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2015.1264
更新日期:2016-12-01 00:00:00
abstract:: Background: Many countries have introduced a compulsory use of community masks for certain public areas during the SARS-CoV-2 pandemic. Different manufacturers offer reusable community masks in large quantities. The efficacy of these masks, however, is unknown. ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2020.1635
更新日期:2020-09-23 00:00:00
abstract:BACKGROUND:Model predictions of regional deposition in the respiratory tract are useful in assessing factors that influence the effectiveness of aerosol delivery. Regional deposition models have previously been coupled with models of mucous production and clearance to estimate initial concentrations of drug deposited i...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2017.1377
更新日期:2018-02-01 00:00:00
abstract:BACKGROUND:Computer modeling is used to predict inhaled aerosol deposition in the lung based on definition of the aerosol characteristics and the breathing pattern and airway anatomy of the subject. Validation of the models is limited by the lack of detailed experimental data. Three-dimensional imaging provides an oppo...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2014.1191
更新日期:2015-12-01 00:00:00
abstract:BACKGROUND:The Respimat Soft Mist Inhaler is reported to generate an aerosol with low spray momentum and a small droplet size. However, the transport characteristics of the Respimat aerosol are not well understood. The objective of this study was to characterize the transport and deposition of an aerosol emitted from t...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2008.0708
更新日期:2009-06-01 00:00:00
abstract::Exhaled breath condensate (EBC) consists mainly of water, but also contains semivolatile and nonvolatile compounds. The aim of this study was to develop a system in which two condensers are simultaneously used in series to clarify the mechanisms of EBC condensation. Two aliquots of EBC (EBC1 and EBC2) were collected f...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2007.0644
更新日期:2008-03-01 00:00:00
abstract:BACKGROUND:Preclinical evaluation of new chemical entities (NCEs) designed to be administered by inhalation route requires lung administration to rodents, especially in the discovery phase. Different administration methods have been used until now, but more efforts are required to obtain controlled and reproducible lun...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2017.1369
更新日期:2018-02-01 00:00:00
abstract:BACKGROUND:The Abbreviated Impactor Measurement (AIM) concept simplifies determination of aerodynamic size metrics for inhaler quality control testing. A similar approach is needed to compare in vitro particle size distribution metrics with human respiratory tract (HRT) deposition. METHODS:An abbreviated impactor base...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2011.0925
更新日期:2012-08-01 00:00:00
abstract:BACKGROUND:Inhaled atropine is being developed as a systemic and pulmonary treatment for the extended recovery period after chemical weapons exposure. We performed a pharmacokinetics study comparing inhaled atropine delivery using the MicroDose Therapeutx Dry Powder Inhaler (DPIA) with intramuscular (IM) atropine deliv...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,随机对照试验
doi:10.1089/jamp.2011.0948
更新日期:2013-02-01 00:00:00
abstract::Antibiotic-resistant bacterial infections have renewed interest in finding substitute methods of treatment. The purpose of the present in vitro study was to investigate the possibility of respiratory delivery of a Burkholderia cepacia complex (BCC) bacteriophage by nebulized aerosol administration. Bacteriophages in i...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2008.0701
更新日期:2008-12-01 00:00:00
abstract:BACKGROUND:Very little is known about the role of nasal morphology due to ethnic variation on particle deposition pattern in the sinonasal cavity. This preliminary study utilizes computational fluid dynamics (CFD) modeling to investigate sinonasal airway morphology and deposition patterns of intranasal sprayed particle...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2014.1205
更新日期:2016-04-01 00:00:00
abstract:BACKGROUND:To validate the 'Test of Adherence to Inhalers' (TAI), a 12-item questionnaire designed to assess the adherence to inhalers in patients with COPD or asthma. METHODS:A total of 1009 patients with asthma or COPD participated in a cross-sectional multicenter study. Patients with electronic adherence ≥80% were ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,多中心研究
doi:10.1089/jamp.2015.1212
更新日期:2016-04-01 00:00:00
abstract:BACKGROUND:The site of deposition in the respiratory tract for aerosolized, inhaled therapeutic drugs depends on both the particles' aerodynamic size and the patient's breathing pattern. METHODS:In 21 healthy subjects with normal lung function, we evaluated an extremely slow inhalation of a large 9.5-μm MMAD particle ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2008.0711
更新日期:2010-12-01 00:00:00
abstract::Significant advances have been made in the last 50 years in developing safe and efficacious aerosol formulations for pulmonary delivery. The key to future innovation may lie at the interface between biology and particle engineering. Improved understanding of biological processes including particle clearance, cellular ...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,评审
doi:10.1089/jamp.2010.0838
更新日期:2010-12-01 00:00:00
abstract::The success of inhalation therapy is not only dependent upon the pharmacology of the drugs being inhaled but also upon the site and extent of deposition in the respiratory tract. Similarly, the toxicity of environmental and industrial particulate matter is affected not only by the nature of the dust but also by the am...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2020.29029.cd
更新日期:2020-08-01 00:00:00
abstract:: Background: Many substances used in inhalation research are water soluble and can be administered as nebulized solutions. Typical examples are therapeutic, small-molecular agents, or macromolecules. Another category is a number of water-soluble agents used for airway diagn...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2019.1554
更新日期:2020-04-01 00:00:00
abstract:: Background: The photo reflection method (PRM) is used to measure light reflected from particles released from dry powder inhalers (DPIs). This simple method depicts time trajectories of released drugs; however, it underestimates the number of particles at high peak inhalat...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2020.1610
更新日期:2020-11-04 00:00:00
abstract:BACKGROUND:Vitamin A (VA) is crucial for lung growth and development. In premature infants, inadequate VA levels are associated with an increased risk of bronchopulmonary dysplasia (BPD). Intramuscular VA supplementation has been shown to decrease the incidence of BPD, but is not widely used in the clinical setting due...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2017.1438
更新日期:2018-12-01 00:00:00
abstract:BACKGROUND:Currently bronchial provocation testing (BPT) using mannitol powder cannot be performed in children under 6 years. A primary reason is it is challenging for children at this age to generate a consistent inspiratory effort to inhale mannitol efficiently from a dry powder inhaler. A prototype system, which doe...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章
doi:10.1089/jamp.2015.1208
更新日期:2015-12-01 00:00:00
abstract:BACKGROUND:The unit dose dry powder inhaler (UD-DPI) is being considered as an alternative inhaler platform that, if developed, has the potential to improve access to inhaled respiratory medicines in developing countries. AIM:This study compared the systemic exposure of fluticasone furoate after delivery from the UD-D...
journal_title:Journal of aerosol medicine and pulmonary drug delivery
pub_type: 杂志文章,随机对照试验
doi:10.1089/jamp.2016.1322
更新日期:2017-10-01 00:00:00