Pharmacokinetic Comparison of a Unit Dose Dry Powder Inhaler with a Multidose Dry Powder Inhaler for Delivery of Fluticasone Furoate.

Abstract:

BACKGROUND:The unit dose dry powder inhaler (UD-DPI) is being considered as an alternative inhaler platform that, if developed, has the potential to improve access to inhaled respiratory medicines in developing countries. AIM:This study compared the systemic exposure of fluticasone furoate after delivery from the UD-DPI with that from the ELLIPTA® inhaler. METHODS:This open-label, five-way cross-over, randomized, single-dose study in healthy subjects evaluated fluticasone furoate systemic exposure of three dose strengths (using four inhalations), 4 × 80 μg [320 μg], 4 × 100 μg [400 μg], and 4 × 140 μg [560 μg]), and two percentages of drug in lactose blends (0.6% and 0.8% by weight) after delivery from the UD-DPI compared with systemic exposures from the ELLIPTA inhaler (4 × 100 μg [400 μg] dose, 0.8% lactose blend). The primary treatment comparisons were area under the concentration-time curve from time 0 to 6 hours [AUC0-6] and maximum plasma concentration [Cmax]. RESULTS:After single-dose administration of fluticasone furoate, systemic exposure was lower from all UD-DPI formulations versus the ELLIPTA inhaler in terms of both AUC0-6 [AUC0-6 geometric least squares mean (GLM) ratios confidence interval (90% CI) for: UD-DPI (400 μg 0.8% blend)/ELLIPTA: 0.61 (0.55-0.67) and Cmax GLM (90% CI) for: UD-DPI (400 μg 0.8% blend)/ELLIPTA: 0.56 (0.49-0.64)]. Systemic exposures were ∼10% lower for fluticasone furoate UD-DPI for the 0.8% blend versus the 0.6% blend [GLM ratio (90% CI); 0.90 (0.81-1.00) for AUC0-6 and 0.89 (0.77-1.01) for Cmax], and increasing doses of fluticasone furoate from the UD-DPI showed systemic exposures that were approximately dose proportional. All treatments were well tolerated. CONCLUSIONS:Fluticasone furoate systemic exposure was lower from the UD-DPI than from the ELLIPTA inhaler, but the UD-DPI formulations did demonstrate detectable systemic levels and approximate dose proportionality. Together with the good tolerability shown, these data support further evaluation of the UD-DPI as a potential device for delivering inhaled respiratory drugs.

authors

Mehta R,Moore A,Riddell K,Joshi S,Chan R

doi

10.1089/jamp.2016.1322

subject

Has Abstract

pub_date

2017-10-01 00:00:00

pages

332-338

issue

5

eissn

1941-2711

issn

1941-2703

journal_volume

30

pub_type

杂志文章,随机对照试验
  • A New Quantitative Method for Evaluating Dry Powder Inhalation Efficiency in Asthma Patients.

    abstract:PURPOSE:Many methods have been developed to evaluate dry powder inhalation techniques and their efficiency for disease control in asthma patients. However, it is difficult to apply these methods to clinical practice and research. In this study, we introduce a simple new method that can be applied to dry powder inhalati...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1193

    authors: Liang Y,Hu H,Tian C,Lei Y,Liu C,Luo F

    更新日期:2016-10-01 00:00:00

  • Aerosol Therapy in Adults Receiving High Flow Nasal Cannula Oxygen Therapy.

    abstract:BACKGROUND:High flow nasal cannula oxygen therapy (HFT) is increasingly used in intensive and emergency care departments. Patients suffering from respiratory failure, who are likely to benefit from HFT, may require aerosolized bronchodilators; therefore, combining nebulization with HFT may be relevant. This study aimed...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1219

    authors: Réminiac F,Vecellio L,Heuzé-Vourc'h N,Petitcollin A,Respaud R,Cabrera M,Pennec DL,Diot P,Ehrmann S

    更新日期:2016-04-01 00:00:00

  • Correcting Photo Reflection Method Output and Its Application in the Dynamic Analysis of Particle Release from Dry Powder Inhalers.

    abstract:: Background: The photo reflection method (PRM) is used to measure light reflected from particles released from dry powder inhalers (DPIs). This simple method depicts time trajectories of released drugs; however, it underestimates the number of particles at high peak inhalat...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.1610

    authors: Kondo T,Hibino M,Tanigaki T,Tajiri S,Horiuchi S

    更新日期:2020-11-04 00:00:00

  • Inhaled insulin: too soon to be forgotten?

    abstract::Inhalation is a potentially viable route of administration for numerous agents. In diabetes mellitus, the need for frequent injections to achieve ideal glycemic control remains a significant limitation for initiating and complying with insulin therapy in a large number of patients. To overcome this barrier, inhaled in...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2011.0876

    authors: Zarogoulidis P,Papanas N,Kouliatsis G,Spyratos D,Zarogoulidis K,Maltezos E

    更新日期:2011-10-01 00:00:00

  • Assessment of the Power Required for Optimal Use of Current Inhalation Devices.

    abstract:: Background: Inhalation of medications is the cornerstone in the treatment of patients with lung diseases. A variety of inhalation devices exists and each device has specific requirements to achieve optimum inhalation of the drug. The goal of this study was to establish a c...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1376

    authors: Pohlmann G,Hohlfeld JM,Haidl P,Pankalla J,Cloes RM

    更新日期:2018-12-01 00:00:00

  • Evaluation of the Respimat Soft Mist Inhaler using a concurrent CFD and in vitro approach.

    abstract:BACKGROUND:The Respimat Soft Mist Inhaler is reported to generate an aerosol with low spray momentum and a small droplet size. However, the transport characteristics of the Respimat aerosol are not well understood. The objective of this study was to characterize the transport and deposition of an aerosol emitted from t...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0708

    authors: Worth Longest P,Hindle M

    更新日期:2009-06-01 00:00:00

  • In vitro characterization of the OptiChamber Diamond valved holding chamber.

    abstract:BACKGROUND:Use of a valved holding chamber (VHC) in conjunction with a pressurized metered dose inhaler (pMDI) can reduce issues relating to poor actuation-inhalation coordination and potentially improve the lung deposition of aerosol, compared with use of a pMDI alone. However, the performance of a VHC is influenced b...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2013.1067

    authors: Hatley RH,von Hollen D,Sandell D,Slator L

    更新日期:2014-08-01 00:00:00

  • The effects of training on inhaler technique and quality of life in patients with COPD.

    abstract:OBJECTIVES:This experimental study was conducted to determine the effects of training on inhaler technique and quality of life in patients with chronic obstructive pulmonary disease (COPD). METHODS:Among the patients who applied at the outpatient clinic of chest diseases between March 2009 and May 2010, a total of 69 ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/jamp.2012.1017

    authors: Göriş S,Taşci S,Elmali F

    更新日期:2013-12-01 00:00:00

  • Collecting exhaled breath condensate (EBC) with two condensers in series: a promising technique for studying the mechanisms of EBC formation, and the volatility of selected biomarkers.

    abstract::Exhaled breath condensate (EBC) consists mainly of water, but also contains semivolatile and nonvolatile compounds. The aim of this study was to develop a system in which two condensers are simultaneously used in series to clarify the mechanisms of EBC condensation. Two aliquots of EBC (EBC1 and EBC2) were collected f...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2007.0644

    authors: Corradi M,Goldoni M,Caglieri A,Folesani G,Poli D,Corti M,Mutti A

    更新日期:2008-03-01 00:00:00

  • Pulmonary Toxicity of Benzalkonium Chloride.

    abstract::The available toxicity data of benzalkonium chloride (BKC) clearly shows that it is toxic; however, the weight of evidence favors the view that at doses encountered in nasally and orally inhaled pharmaceutical preparations it is well tolerated. The adverse toxicological data predominantly come from in vitro and animal...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2017.1390

    authors: Johnson NF

    更新日期:2018-02-01 00:00:00

  • Physiologically Based Pharmacokinetic/Pharmacodynamic Modeling Accurately Predicts the Better Bronchodilatory Effect of Inhaled Versus Oral Salbutamol Dosage Forms.

    abstract:BACKGROUND:Predicting local lung tissue pharmacodynamic (PD) responses of inhaled drugs is a longstanding challenge related to the lack of experimental techniques to determine local free drug concentrations. This has prompted the use of physiologically based pharmacokinetic (PBPK) modeling to potentially predict local ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1436

    authors: Boger E,Fridén M

    更新日期:2019-02-01 00:00:00

  • Physicochemical and Pharmacokinetic Evaluation of Spray-Dried Coformulation of Salvia miltiorrhiza Polyphenolic Acid and L-Leucine with Improved Bioavailability.

    abstract:: Background: Salvia miltiorrhiza polyphenolic acid (SMPA) is effective in the treatment of cardiovascular diseases and currently it is administered orally or intravenously. However, SMPA is poorly absorbed orally and quickly eliminated in vivo. A long-term frequent intraveno...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2019.1538

    authors: Lu P,Xing Y,Peng H,Liu Z,Zhou QT,Xue Z,Ma Z,Kebebe D,Zhang B,Liu H

    更新日期:2020-04-01 00:00:00

  • Spiromax, a New Dry Powder Inhaler: Dose Consistency under Simulated Real-World Conditions.

    abstract:BACKGROUND:Spiromax(®) is a novel dry powder inhaler for patients with asthma or chronic obstructive pulmonary disease (COPD). The studies presented here provide further data on attributes (in vitro dosing consistency with budesonide-formoterol (DuoResp) Spiromax; flow rates through empty versions of the Spiromax and T...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1216

    authors: Canonica GW,Arp J,Keegstra JR,Chrystyn H

    更新日期:2015-10-01 00:00:00

  • Characterization of Medication Velocity and Size Distribution from Pressurized Metered-Dose Inhalers by Phase Doppler Anemometry.

    abstract:BACKGROUND:Particle size and velocity are two of the most significant factors that impact the deposition of pressurized metered-dose inhaler (pMDI) sprays in the mouth cavity. pMDIs are prominently used around the world in the treatment of patients suffering from a variety of lung diseases such as asthma and chronic ob...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1264

    authors: Alatrash A,Matida E

    更新日期:2016-12-01 00:00:00

  • Evaluation of comparative performance of orally inhaled drug products in view of the classical bioequivalence paradigms: an analysis of the current scientific and regulatory dilemmas of inhaler evaluation.

    abstract::Since the early 1960s, there has been a continuous evolution in scientific understanding regarding bioequivalence (BE) of oral dosage forms, intermittently punctuated by some breakthrough research findings and conceptual advances. The accumulated knowledge from this body of research has been translated into a sophisti...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2014.1144

    authors: Horhota ST

    更新日期:2014-12-01 00:00:00

  • Adapting the Abbreviated Impactor Measurement (AIM) concept to make appropriate inhaler aerosol measurements to compare with clinical data: a scoping study with the "Alberta" idealized throat (AIT) inlet.

    abstract:BACKGROUND:The Abbreviated Impactor Measurement (AIM) concept simplifies determination of aerodynamic size metrics for inhaler quality control testing. A similar approach is needed to compare in vitro particle size distribution metrics with human respiratory tract (HRT) deposition. METHODS:An abbreviated impactor base...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2011.0925

    authors: Mitchell J,Copley M,Sizer Y,Russell T,Solomon D

    更新日期:2012-08-01 00:00:00

  • Aerosolizing Lipid Dispersions Enables Antibiotic Transport Across Mimics of the Lung Airway Surface Even in the Presence of Pre-existing Lipid Monolayers.

    abstract:BACKGROUND:Secondary lung infections are the primary cause of morbidity associated with cystic fibrosis lung disease. Aerosolized antibiotic inhalation is potentially advantageous but has limited effectiveness due to altered airway aerodynamics and deposition patterns that limit drug access to infected regions. One pot...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1412

    authors: Iasella SV,Stetten AZ,Corcoran TE,Garoff S,Przybycien TM,Tilton RD

    更新日期:2018-08-01 00:00:00

  • Optimal delivery of aerosols to infants during mechanical ventilation.

    abstract:PURPOSE:The objective of this study was to determine optimal aerosol delivery conditions for a full-term (3.6 kg) infant receiving invasive mechanical ventilation by evaluating the effects of aerosol particle size, a new wye connector, and timing of aerosol delivery. METHODS:In vitro experiments used a vibrating mesh ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2013.1077

    authors: Longest PW,Azimi M,Hindle M

    更新日期:2014-10-01 00:00:00

  • Intranasal Deposition of Accuspray™ Aerosol in Anatomically Correct Models of 2-, 5-, and 12-Year-Old Children.

    abstract:BACKGROUND:To our knowledge, quantification of intranasal deposition of aerosol generated by Accuspray(™) (AS) in children has never been published. We hypothesized that deposition would vary significantly with age and with placement of the device within, or outside, of the nostril. METHODS:We tested these hypotheses ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1174

    authors: Laube BL,Sharpless G,Vikani AR,Harrand V,Zinreich SJ,Sedberry K,Knaus D,Barry J,Papania M

    更新日期:2015-10-01 00:00:00

  • Controlled, Parametric, Individualized, 2-D and 3-D Imaging Measurements of Aerosol Deposition in the Respiratory Tract of Asthmatic Human Subjects for Model Validation.

    abstract:BACKGROUND:Computer modeling is used to predict inhaled aerosol deposition in the lung based on definition of the aerosol characteristics and the breathing pattern and airway anatomy of the subject. Validation of the models is limited by the lack of detailed experimental data. Three-dimensional imaging provides an oppo...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1191

    authors: Fleming J,Conway J,Majoral C,Katz I,Caillibotte G,Pichelin M,Montesantos S,Bennett M

    更新日期:2015-12-01 00:00:00

  • Deposition Mechanisms.

    abstract::The success of inhalation therapy is not only dependent upon the pharmacology of the drugs being inhaled but also upon the site and extent of deposition in the respiratory tract. Similarly, the toxicity of environmental and industrial particulate matter is affected not only by the nature of the dust but also by the am...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.29029.cd

    authors: Darquenne C

    更新日期:2020-08-01 00:00:00

  • Use of a Remote Inhaler Monitoring Device to Measure Change in Inhaler Use with Chronic Obstructive Pulmonary Disease Exacerbations.

    abstract:BACKGROUND:Remote inhaler monitoring is an emerging technology that enables the healthcare team to monitor the time and location of a patient's inhaler use. We assessed the feasibility of remote inhaler monitoring for chronic obstructive pulmonary disease (COPD) patients and the pattern of albuterol inhaler use associa...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1383

    authors: Sumino K,Locke ER,Magzamen S,Gylys-Colwell I,Humblet O,Nguyen HQ,Thomas RM,Fan VS

    更新日期:2018-06-01 00:00:00

  • Model Calculations of Regional Deposition and Disposition for Single Doses of Inhaled Liposomal and Dry Powder Ciprofloxacin.

    abstract:BACKGROUND:Model predictions of regional deposition in the respiratory tract are useful in assessing factors that influence the effectiveness of aerosol delivery. Regional deposition models have previously been coupled with models of mucous production and clearance to estimate initial concentrations of drug deposited i...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1377

    authors: Martin AR,Finlay WH

    更新日期:2018-02-01 00:00:00

  • The co-imaging of gamma camera measurements of aerosol deposition and respiratory anatomy.

    abstract::The use of gamma camera imaging following the inhalation of a radiolabel has been widely used by researchers to investigate the fate of inhaled aerosols. The application of two-dimensional (2D) planar gamma scintigraphy and single-photon emission computed tomography (SPECT) to the study of inhaled aerosols is discusse...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2011.0960

    authors: Conway J,Fleming J,Bennett M,Havelock T

    更新日期:2013-06-01 00:00:00

  • Inhaled Antibiotic Therapy for the Treatment of Upper Respiratory Tract Infections.

    abstract::Upper respiratory tract infections (URTIs), primarily acute rhinopharyngitis, tonsillitis, adenoiditis, and rhinosinusitis (RS), are major causes of morbidity in both children and adults of any age. In addition to the frequent occurrence of related medical problems and the associated socioeconomic costs, URTIs have a ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2016.1300

    authors: Esposito S,Rosazza C,Sciarrabba CS,Principi N

    更新日期:2017-02-01 00:00:00

  • Decreased level of PDCD4 (programmed cell death 4) protein activated cell proliferation in the lung of A/J mouse.

    abstract:BACKGROUND:Programmed cell death 4 (PDCD4), a protein that binds to eukaryotic initiation factor 4A (eIF4A), inhibits the initiation of translation. Although a number of tumor suppressors target transcription, Pdcd4 is the first suppressor targeting protein translation, and has also been suggested to function as a tumo...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2009.0778

    authors: Hwang SK,Minai-Tehrani A,Lim HT,Shin JY,An GH,Lee KH,Park KR,Kim YS,Beck GR Jr,Yang HS,Cho MH

    更新日期:2010-10-01 00:00:00

  • Community Masks During the SARS-CoV-2 Pandemic: Filtration Efficacy and Air Resistance.

    abstract:: Background: Many countries have introduced a compulsory use of community masks for certain public areas during the SARS-CoV-2 pandemic. Different manufacturers offer reusable community masks in large quantities. The efficacy of these masks, however, is unknown. ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.1635

    authors: Maurer L,Peris D,Kerl J,Guenther F,Koehler D,Dellweg D

    更新日期:2020-09-23 00:00:00

  • The I-neb Adaptive Aerosol Delivery System enhances delivery of alpha1-antitrypsin with controlled inhalation.

    abstract:BACKGROUND:Inhaled alpha1-antitrypsin (AAT) is being developed for treatment of cystic fibrosis to protect the lungs from excessive free elastase. High drug costs mandate a very efficient aerosol system to deliver a high payload to the airways. The I-neb Adaptive Aerosol Delivery (AAD) System is a portable, electronic,...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2009.0793

    authors: Geller DE,Kesser KC

    更新日期:2010-04-01 00:00:00

  • Pulmonary formulations: what remains to be done?

    abstract::Significant advances have been made in the last 50 years in developing safe and efficacious aerosol formulations for pulmonary delivery. The key to future innovation may lie at the interface between biology and particle engineering. Improved understanding of biological processes including particle clearance, cellular ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2010.0838

    authors: Weers JG,Bell J,Chan HK,Cipolla D,Dunbar C,Hickey AJ,Smith IJ

    更新日期:2010-12-01 00:00:00

  • An Apparatus to Deliver Mannitol Powder for Bronchial Provocation in Children Under Six Years Old.

    abstract:BACKGROUND:Currently bronchial provocation testing (BPT) using mannitol powder cannot be performed in children under 6 years. A primary reason is it is challenging for children at this age to generate a consistent inspiratory effort to inhale mannitol efficiently from a dry powder inhaler. A prototype system, which doe...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1208

    authors: Tang P,Leung SS,Hor E,Ruzycki CA,Carrigy NB,Finlay WH,Brannan JD,Devadason S,Anderson SD,Sly PD,Samnick K,Chan HK

    更新日期:2015-12-01 00:00:00