Adapting the Abbreviated Impactor Measurement (AIM) concept to make appropriate inhaler aerosol measurements to compare with clinical data: a scoping study with the "Alberta" idealized throat (AIT) inlet.

Abstract:

BACKGROUND:The Abbreviated Impactor Measurement (AIM) concept simplifies determination of aerodynamic size metrics for inhaler quality control testing. A similar approach is needed to compare in vitro particle size distribution metrics with human respiratory tract (HRT) deposition. METHODS:An abbreviated impactor based on the Andersen eight-stage cascade impactor (ACI) was developed having two size-fractionating stages with cut-points at 4.7 and 1.1 μm aerodynamic diameter at 28.3 L/min, to distinguish between coarse (CPM), fine (FPM), and extra-fine (EPM) mass fractions likely to deposit in the oropharynx, airways of the lungs, or be exhaled, respectively. In vitro data were determined for pressurized metered dose inhaler (pMDI)-delivered salbutamol (100 μg/actuation ex valve) with an "Alberta" idealized adult upper airway (throat) inlet (AIM-pHRT). Corresponding benchmark data for a full resolution Andersen eight-stage cascade impactor with "Alberta" idealized throat (ACI-AIT) and ACI-Ph.Eur./USP inlet were obtained with the same product. RESULTS:Mass recoveries (μg/actuation; mean ± SD) were equivalent at 100.5 ± 0.7; 97.2 ± 4.9 and 101.5 ± 9.5 for the AIM-pHRT, ACI-AIT, and ACI-Ph.Eur./USP induction port, respectively [one-way analysis of variance (ANOVA), p=0.64]. Corresponding values of CPM were 59.2 ± 4.2; 58.4 ± 2.4, and 65.6 ± 5.8; the AIT captured larger particles more efficiently than the Ph.Eur./USP induction port, so that less large particle mass was apparent in the upper stages of the ACI-AIT (p ≤ 0.037). Equivalent values of FPM were similar regardless of inlet/abbreviation at 41.3 ± 4.2; 38.7 ± 3.0, and 35.9 ± 3.8 (p=0.054), and EPM measures (1.7 ± 0.3; 2.0 ± 0.5; 2.1 ± 0.3) were also comparable (p=0.32). CONCLUSIONS:The AIT inlet significantly increased the capture of the coarse fraction compared with that collected by the Ph.Eur./USP induction port. Measures obtained using the AIM-pHRT apparatus were comparable with those obtained with the ACI-AIT.

authors

Mitchell J,Copley M,Sizer Y,Russell T,Solomon D

doi

10.1089/jamp.2011.0925

subject

Has Abstract

pub_date

2012-08-01 00:00:00

pages

188-97

issue

4

eissn

1941-2711

issn

1941-2703

journal_volume

25

pub_type

杂志文章
  • Sustained mechanical and clinical functionality of the flexhaler dry powder inhaler.

    abstract::Flexhaler is a multiple-dose, inspiratory flow-driven dry powder inhaler that is a newer version of Turbuhaler, and is identical to the Symbicort Turbuhaler. Sustained performance is of the utmost importance to ensure consistent drug delivery throughout the lifespan of the inhaler. We report functionality testing resu...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0700

    authors: Lööf T,Elfman P,Ström P,Törngren A,Borgström L

    更新日期:2008-12-01 00:00:00

  • Model Calculations of Regional Deposition and Disposition for Single Doses of Inhaled Liposomal and Dry Powder Ciprofloxacin.

    abstract:BACKGROUND:Model predictions of regional deposition in the respiratory tract are useful in assessing factors that influence the effectiveness of aerosol delivery. Regional deposition models have previously been coupled with models of mucous production and clearance to estimate initial concentrations of drug deposited i...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1377

    authors: Martin AR,Finlay WH

    更新日期:2018-02-01 00:00:00

  • Pharmacokinetic Comparison of a Unit Dose Dry Powder Inhaler with a Multidose Dry Powder Inhaler for Delivery of Fluticasone Furoate.

    abstract:BACKGROUND:The unit dose dry powder inhaler (UD-DPI) is being considered as an alternative inhaler platform that, if developed, has the potential to improve access to inhaled respiratory medicines in developing countries. AIM:This study compared the systemic exposure of fluticasone furoate after delivery from the UD-D...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/jamp.2016.1322

    authors: Mehta R,Moore A,Riddell K,Joshi S,Chan R

    更新日期:2017-10-01 00:00:00

  • Decreased level of PDCD4 (programmed cell death 4) protein activated cell proliferation in the lung of A/J mouse.

    abstract:BACKGROUND:Programmed cell death 4 (PDCD4), a protein that binds to eukaryotic initiation factor 4A (eIF4A), inhibits the initiation of translation. Although a number of tumor suppressors target transcription, Pdcd4 is the first suppressor targeting protein translation, and has also been suggested to function as a tumo...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2009.0778

    authors: Hwang SK,Minai-Tehrani A,Lim HT,Shin JY,An GH,Lee KH,Park KR,Kim YS,Beck GR Jr,Yang HS,Cho MH

    更新日期:2010-10-01 00:00:00

  • Single-dose pharmacokinetics and safety pharmacodynamics of formoterol delivered by two different dry powder inhalers.

    abstract::The present study aimed at assessing the pharmacokinetics (PK) and safety pharmacodynamics (PD) of 24 microg formoterol delivered via a Novolizer and via an Aerolizer in healthy subjects. This was a randomized, open-label, crossover study. Beside PK, serum potassium, and glucose profiles, vital signs, and ECG were rec...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/jamp.2008.0690

    authors: Petzold U,Kremer HJ,Nguyen DT,Munzel U,Dietrich H,Maus J

    更新日期:2008-09-01 00:00:00

  • Evaluation of comparative performance of orally inhaled drug products in view of the classical bioequivalence paradigms: an analysis of the current scientific and regulatory dilemmas of inhaler evaluation.

    abstract::Since the early 1960s, there has been a continuous evolution in scientific understanding regarding bioequivalence (BE) of oral dosage forms, intermittently punctuated by some breakthrough research findings and conceptual advances. The accumulated knowledge from this body of research has been translated into a sophisti...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2014.1144

    authors: Horhota ST

    更新日期:2014-12-01 00:00:00

  • Age-dependent deterioration of peak inspiratory flow with two kinds of dry powder corticosteroid inhalers (Diskus and Turbuhaler) and relationships with asthma control.

    abstract:BACKGROUND:Inhaled corticosteroid (ICS) therapy has improved the quality of life (QOL) for many asthmatics and reduced mortality rates associated with asthma. However, some patients do not obtain therapeutic benefit despite satisfactory adherence. OBJECTIVES:To determine whether asthmatic patients were using ICS devic...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2010.0868

    authors: Baba K,Tanaka H,Nishimura M,Yokoe N,Takahashi D,Yagi T,Yamaguchi E,Maeda Y,Muto T,Hasegawa T

    更新日期:2011-12-01 00:00:00

  • Using MRI to measure aerosol deposition.

    abstract::This article provides a concise review of the use of magnetic resonance imaging (MRI) for measurement of regional aerosol deposition in the lungs. Basic aspects of MRI and its use in lung imaging and measurement of regional ventilation are introduced. Imaging of hydrogen protons (water) and inhaled hyperpolarized gase...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2011.0897

    authors: Thompson RB,Finlay WH

    更新日期:2012-04-01 00:00:00

  • A Computational Study of Nasal Spray Deposition Pattern in Four Ethnic Groups.

    abstract:BACKGROUND:Very little is known about the role of nasal morphology due to ethnic variation on particle deposition pattern in the sinonasal cavity. This preliminary study utilizes computational fluid dynamics (CFD) modeling to investigate sinonasal airway morphology and deposition patterns of intranasal sprayed particle...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1205

    authors: Keeler JA,Patki A,Woodard CR,Frank-Ito DO

    更新日期:2016-04-01 00:00:00

  • Characterization of Medication Velocity and Size Distribution from Pressurized Metered-Dose Inhalers by Phase Doppler Anemometry.

    abstract:BACKGROUND:Particle size and velocity are two of the most significant factors that impact the deposition of pressurized metered-dose inhaler (pMDI) sprays in the mouth cavity. pMDIs are prominently used around the world in the treatment of patients suffering from a variety of lung diseases such as asthma and chronic ob...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1264

    authors: Alatrash A,Matida E

    更新日期:2016-12-01 00:00:00

  • Community Masks During the SARS-CoV-2 Pandemic: Filtration Efficacy and Air Resistance.

    abstract:: Background: Many countries have introduced a compulsory use of community masks for certain public areas during the SARS-CoV-2 pandemic. Different manufacturers offer reusable community masks in large quantities. The efficacy of these masks, however, is unknown. ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.1635

    authors: Maurer L,Peris D,Kerl J,Guenther F,Koehler D,Dellweg D

    更新日期:2020-09-23 00:00:00

  • Evaluation of the Respimat Soft Mist Inhaler using a concurrent CFD and in vitro approach.

    abstract:BACKGROUND:The Respimat Soft Mist Inhaler is reported to generate an aerosol with low spray momentum and a small droplet size. However, the transport characteristics of the Respimat aerosol are not well understood. The objective of this study was to characterize the transport and deposition of an aerosol emitted from t...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0708

    authors: Worth Longest P,Hindle M

    更新日期:2009-06-01 00:00:00

  • Use of a Remote Inhaler Monitoring Device to Measure Change in Inhaler Use with Chronic Obstructive Pulmonary Disease Exacerbations.

    abstract:BACKGROUND:Remote inhaler monitoring is an emerging technology that enables the healthcare team to monitor the time and location of a patient's inhaler use. We assessed the feasibility of remote inhaler monitoring for chronic obstructive pulmonary disease (COPD) patients and the pattern of albuterol inhaler use associa...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1383

    authors: Sumino K,Locke ER,Magzamen S,Gylys-Colwell I,Humblet O,Nguyen HQ,Thomas RM,Fan VS

    更新日期:2018-06-01 00:00:00

  • A New Quantitative Method for Evaluating Dry Powder Inhalation Efficiency in Asthma Patients.

    abstract:PURPOSE:Many methods have been developed to evaluate dry powder inhalation techniques and their efficiency for disease control in asthma patients. However, it is difficult to apply these methods to clinical practice and research. In this study, we introduce a simple new method that can be applied to dry powder inhalati...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1193

    authors: Liang Y,Hu H,Tian C,Lei Y,Liu C,Luo F

    更新日期:2016-10-01 00:00:00

  • The I-neb Adaptive Aerosol Delivery System enhances delivery of alpha1-antitrypsin with controlled inhalation.

    abstract:BACKGROUND:Inhaled alpha1-antitrypsin (AAT) is being developed for treatment of cystic fibrosis to protect the lungs from excessive free elastase. High drug costs mandate a very efficient aerosol system to deliver a high payload to the airways. The I-neb Adaptive Aerosol Delivery (AAD) System is a portable, electronic,...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2009.0793

    authors: Geller DE,Kesser KC

    更新日期:2010-04-01 00:00:00

  • Nebulized medications for the treatment of dyspnea: a literature review.

    abstract:BACKGROUND:Dyspnea significantly impacts quality of life and is one of the most common symptoms in advanced illness. Systemically-administered opioids and benzodiazepines have been the most studied and utilized pharmacologic treatments for refractory dyspnea. Less attention has been given to the use of these medication...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2014.1136

    authors: Boyden JY,Connor SR,Otolorin L,Nathan SD,Fine PG,Davis MS,Muir JC

    更新日期:2015-02-01 00:00:00

  • Intranasal Deposition of Accuspray™ Aerosol in Anatomically Correct Models of 2-, 5-, and 12-Year-Old Children.

    abstract:BACKGROUND:To our knowledge, quantification of intranasal deposition of aerosol generated by Accuspray(™) (AS) in children has never been published. We hypothesized that deposition would vary significantly with age and with placement of the device within, or outside, of the nostril. METHODS:We tested these hypotheses ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1174

    authors: Laube BL,Sharpless G,Vikani AR,Harrand V,Zinreich SJ,Sedberry K,Knaus D,Barry J,Papania M

    更新日期:2015-10-01 00:00:00

  • Physiologically Based Pharmacokinetic/Pharmacodynamic Modeling Accurately Predicts the Better Bronchodilatory Effect of Inhaled Versus Oral Salbutamol Dosage Forms.

    abstract:BACKGROUND:Predicting local lung tissue pharmacodynamic (PD) responses of inhaled drugs is a longstanding challenge related to the lack of experimental techniques to determine local free drug concentrations. This has prompted the use of physiologically based pharmacokinetic (PBPK) modeling to potentially predict local ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1436

    authors: Boger E,Fridén M

    更新日期:2019-02-01 00:00:00

  • The co-imaging of gamma camera measurements of aerosol deposition and respiratory anatomy.

    abstract::The use of gamma camera imaging following the inhalation of a radiolabel has been widely used by researchers to investigate the fate of inhaled aerosols. The application of two-dimensional (2D) planar gamma scintigraphy and single-photon emission computed tomography (SPECT) to the study of inhaled aerosols is discusse...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2011.0960

    authors: Conway J,Fleming J,Bennett M,Havelock T

    更新日期:2013-06-01 00:00:00

  • Aerosol Therapy in Adults Receiving High Flow Nasal Cannula Oxygen Therapy.

    abstract:BACKGROUND:High flow nasal cannula oxygen therapy (HFT) is increasingly used in intensive and emergency care departments. Patients suffering from respiratory failure, who are likely to benefit from HFT, may require aerosolized bronchodilators; therefore, combining nebulization with HFT may be relevant. This study aimed...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1219

    authors: Réminiac F,Vecellio L,Heuzé-Vourc'h N,Petitcollin A,Respaud R,Cabrera M,Pennec DL,Diot P,Ehrmann S

    更新日期:2016-04-01 00:00:00

  • Correcting Photo Reflection Method Output and Its Application in the Dynamic Analysis of Particle Release from Dry Powder Inhalers.

    abstract:: Background: The photo reflection method (PRM) is used to measure light reflected from particles released from dry powder inhalers (DPIs). This simple method depicts time trajectories of released drugs; however, it underestimates the number of particles at high peak inhalat...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.1610

    authors: Kondo T,Hibino M,Tanigaki T,Tajiri S,Horiuchi S

    更新日期:2020-11-04 00:00:00

  • The Impact of Common Inhaler Errors on Drug Delivery: Investigating Critical Errors with a Dry Powder Inhaler.

    abstract:BACKGROUND:Researchers, using checklists, have identified that 30%-90% of patients make errors in inhaler use. It is not certain whether these errors affect the delivery of medication. We have developed an electronic monitor (INCA™) that records audio each time an inhaler is used, providing objective information on inh...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2016.1334

    authors: Sulaiman I,Seheult J,Sadasivuni N,MacHale E,Killane I,Giannoutsos S,Cushen B,Mokoka MC,Bhreathnach AS,Boland F,Reilly RB,Costello RW

    更新日期:2017-08-01 00:00:00

  • Pulmonary Toxicity of Benzalkonium Chloride.

    abstract::The available toxicity data of benzalkonium chloride (BKC) clearly shows that it is toxic; however, the weight of evidence favors the view that at doses encountered in nasally and orally inhaled pharmaceutical preparations it is well tolerated. The adverse toxicological data predominantly come from in vitro and animal...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2017.1390

    authors: Johnson NF

    更新日期:2018-02-01 00:00:00

  • Assessment of the Power Required for Optimal Use of Current Inhalation Devices.

    abstract:: Background: Inhalation of medications is the cornerstone in the treatment of patients with lung diseases. A variety of inhalation devices exists and each device has specific requirements to achieve optimum inhalation of the drug. The goal of this study was to establish a c...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1376

    authors: Pohlmann G,Hohlfeld JM,Haidl P,Pankalla J,Cloes RM

    更新日期:2018-12-01 00:00:00

  • Aerosolizing Lipid Dispersions Enables Antibiotic Transport Across Mimics of the Lung Airway Surface Even in the Presence of Pre-existing Lipid Monolayers.

    abstract:BACKGROUND:Secondary lung infections are the primary cause of morbidity associated with cystic fibrosis lung disease. Aerosolized antibiotic inhalation is potentially advantageous but has limited effectiveness due to altered airway aerodynamics and deposition patterns that limit drug access to infected regions. One pot...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1412

    authors: Iasella SV,Stetten AZ,Corcoran TE,Garoff S,Przybycien TM,Tilton RD

    更新日期:2018-08-01 00:00:00

  • Collecting exhaled breath condensate (EBC) with two condensers in series: a promising technique for studying the mechanisms of EBC formation, and the volatility of selected biomarkers.

    abstract::Exhaled breath condensate (EBC) consists mainly of water, but also contains semivolatile and nonvolatile compounds. The aim of this study was to develop a system in which two condensers are simultaneously used in series to clarify the mechanisms of EBC condensation. Two aliquots of EBC (EBC1 and EBC2) were collected f...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2007.0644

    authors: Corradi M,Goldoni M,Caglieri A,Folesani G,Poli D,Corti M,Mutti A

    更新日期:2008-03-01 00:00:00

  • Effect of Posture on Regional Deposition of Coarse Particles in the Healthy Human Lung.

    abstract:BACKGROUND:Understanding the regional partition of deposition of inhaled particles within the lung is important for improving targeted delivery of inhaled aerosolized drugs. One factor affecting regional deposition is gravity. As the lung deforms under its own weight, changes in lung volume, in airway geometries, and i...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1189

    authors: Sá RC,Zeman KL,Bennett WD,Prisk GK,Darquenne C

    更新日期:2015-12-01 00:00:00

  • Development of an in vitro model to assess deposition of aerosol particles in a representative replica of the rat's respiratory tract.

    abstract:BACKGROUND:Small rodents continue to be the mainstay for the assessment of pharmacological and toxicological data of inhaled therapeutics. For meaningful interpretation of the results information about deposition of aerosol particles in the respiratory tract is warranted, but not trivial to obtain for animals with nose...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2011.0902

    authors: Ahmed A,Prime D,Burnell PK,Högger P

    更新日期:2012-06-01 00:00:00

  • In vitro characterization of the OptiChamber Diamond valved holding chamber.

    abstract:BACKGROUND:Use of a valved holding chamber (VHC) in conjunction with a pressurized metered dose inhaler (pMDI) can reduce issues relating to poor actuation-inhalation coordination and potentially improve the lung deposition of aerosol, compared with use of a pMDI alone. However, the performance of a VHC is influenced b...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2013.1067

    authors: Hatley RH,von Hollen D,Sandell D,Slator L

    更新日期:2014-08-01 00:00:00

  • Validation of the 'Test of the Adherence to Inhalers' (TAI) for Asthma and COPD Patients.

    abstract:BACKGROUND:To validate the 'Test of Adherence to Inhalers' (TAI), a 12-item questionnaire designed to assess the adherence to inhalers in patients with COPD or asthma. METHODS:A total of 1009 patients with asthma or COPD participated in a cross-sectional multicenter study. Patients with electronic adherence ≥80% were ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,多中心研究

    doi:10.1089/jamp.2015.1212

    authors: Plaza V,Fernández-Rodríguez C,Melero C,Cosío BG,Entrenas LM,de Llano LP,Gutiérrez-Pereyra F,Tarragona E,Palomino R,López-Viña A,TAI Study Group.

    更新日期:2016-04-01 00:00:00