Evaluating the feasibility of creatine-weighted CEST MRI in human brain at 7 T using a Z-spectral fitting approach.

Abstract:

:The current study aims to evaluate the feasibility of creatine (Cr) chemical exchange saturation transfer (CEST)-weighted MRI at 7 T in the human brain by optimizing the saturation pulse parameters and computing contrast using a Z-spectral fitting approach. The Cr-weighted (Cr-w) CEST contrast was computed from phantoms data. Simulations were carried out to obtain the optimum saturation parameters for Cr-w CEST with lower contribution from other brain metabolites. CEST-w images were acquired from the brains of four human subjects at different saturation parameters. The Cr-w CEST contrast was computed using both asymmetry analysis and Z-spectra fitting approaches (models 1 and 2, respectively) based on Lorentzian functions. For broad magnetization transfer (MT) effect, Gaussian and Super-Lorentzian line shapes were also evaluated. In the phantom study, the Cr-w CEST contrast showed a linear dependence on concentration in physiological range and a nonlinear dependence on saturation parameters. The in vivo Cr-w CEST map generated using asymmetry analysis from the brain represents mixed contrast with contribution from other metabolites as well and relayed nuclear Overhauser effect (rNOE). Simulations provided an estimate for the optimum range of saturation parameters to be used for acquiring brain CEST data. The optimum saturation parameters for Cr-w CEST to be used for brain data were around B1rms  = 1.45 μT and duration = 2 seconds. The Z-spectral fitting approach enabled computation of individual components. This also resulted in mitigating the contribution from MT and rNOE to Cr-w CEST contrast, which is a major source of underestimation in asymmetry analysis. The proposed modified z-spectra fitting approach (model 2) is more stable to noise compared with model 1. Cr-w CEST contrast obtained using fitting was 6.98 ± 0.31% in gray matter and 5.45 ± 0.16% in white matter. Optimal saturation parameters reduced the contribution from other CEST effects to Cr-w CEST contrast, and the proposed Z-spectral fitting approach enabled computation of individual components in Z-spectra of the brain. Therefore, it is feasible to compute Cr-w CEST contrast with a lower contribution from other CEST and rNOE.

journal_name

NMR Biomed

journal_title

NMR in biomedicine

authors

Singh A,Debnath A,Cai K,Bagga P,Haris M,Hariharan H,Reddy R

doi

10.1002/nbm.4176

subject

Has Abstract

pub_date

2019-12-01 00:00:00

pages

e4176

issue

12

eissn

0952-3480

issn

1099-1492

journal_volume

32

pub_type

杂志文章
  • Fast multicomponent 3D-T1ρ relaxometry.

    abstract::NMR relaxometry can provide information about the relaxation of the magnetization in different tissues, increasing our understanding of molecular dynamics and biochemical composition in biological systems. In general, tissues have complex and heterogeneous structures composed of multiple pools. As a result, bulk magne...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4318

    authors: Zibetti MVW,Helou ES,Sharafi A,Regatte RR

    更新日期:2020-12-01 00:00:00

  • Optimal classification of long echo time in vivo magnetic resonance spectra in the detection of recurrent brain tumors.

    abstract::We describe the optimal high-level postprocessing of single-voxel (1)H magnetic resonance spectra and assess the benefits and limitations of automated methods as diagnostic aids in the detection of recurrent brain tumor. In a previous clinical study, 90 long-echo-time single-voxel spectra were obtained from 52 patient...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1041

    authors: Menze BH,Lichy MP,Bachert P,Kelm BM,Schlemmer HP,Hamprecht FA

    更新日期:2006-08-01 00:00:00

  • Knee MRI under varying flexion angles utilizing a flexible flat cable antenna.

    abstract::The aim of this study is to fabricate and test a novel flexible flat cable antenna (FFCA) for MRI of the knee at different flexion angles. The FFCA was made of a flat cable, a tuning/matching circuit and a signal transmission line. To test its feasibility and validity, in vitro and in vivo experiments were carried out...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3264

    authors: Jia F,Yuan H,Zhou D,Zhang J,Wang X,Fang J

    更新日期:2015-04-01 00:00:00

  • 13C NMR spectroscopic analysis of phospholipid metabolism in adrenal chromaffin cells.

    abstract::Phosphatidylcholine (PC) metabolism in bovine adrenal chromaffin cells has been studied in vivo with 100 MHz 13C NMR spectroscopy. The incorporation of 13[CH3]choline was examined in cells embedded in 1% agarose strands and perfused at 37 degrees C. The pattern of 13C NMR spectroscopy. The incorporation of [13CH3]chol...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1940040304

    authors: Rivera CJ,Plishker GA,Morrisett JD,Moore J,Percy AK

    更新日期:1991-06-01 00:00:00

  • Differences in metabolism of 5-fluorouracil and 5-fluorouridine and regulation by glucosamine in human colon cancer multicell tumor spheroids.

    abstract::Glucosamine (GlcN) modulates fluoropyrimidine metabolism and enhances cytotoxicity of 5-fluorouridine (FUrd), but not of 5-fluorouracil (FUra), in human tumor models. To elucidate the underlying metabolic differences between FUra and FUrd, by the use of 19F and 31P NMR spectroscopy we studied these drugs in multicell ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1099-1492(199905)12:3<157::aid-nbm55

    authors: Chen TB,Bajzer Z,Macura S,Vuk-Pavlovic S

    更新日期:1999-05-01 00:00:00

  • A 31P study of fatigue and metabolism in human skeletal muscle with voluntary, intermittent contractions at different forces.

    abstract::Normal subjects performed voluntary, isometric exercise 1 s contraction, 1 s rest for 10 min) of the first dorsal interosseous (FDI) muscle with a target force of 25, 50 and 100% of the maximal voluntary contraction (MVC) force. 31P NMR spectra were collected continuously before, during and after exercise. Data were a...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1940030504

    authors: Newham DJ,Cady EB

    更新日期:1990-10-01 00:00:00

  • Cardiac lipid levels show diurnal changes and long-term variations in healthy human subjects.

    abstract::(1) H-MRS is regularly applied to determine lipid content in ectopic tissue - mostly skeletal muscle and liver - to investigate physiological and/or pathologic conditions, e.g. insulin resistance. Technical developments also allow non-invasive in vivo assessment of cardiac lipids; however, basic data about methodologi...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3186

    authors: Ith M,Stettler C,Xu J,Boesch C,Kreis R

    更新日期:2014-11-01 00:00:00

  • Current awareness in NMR in biomedicine.

    abstract::In order to keep subscribers up-to-date with the latest developments in their field, John Wiley & Sons are providing a current awareness service in each issue of the journal. The bibliography contains newly published material in the field of NMR in biomedicine. Each bibliography is divided into 9 sections: 1 Books, Re...

    journal_title:NMR in biomedicine

    pub_type:

    doi:10.1002/nbm.667

    authors: Wennerberg AB,Jonsson T,Forssberg H,Li TQ

    更新日期:2001-02-01 00:00:00

  • Brain metabolism and blood flow in acute cerebral hypoxia studied by NMR spectroscopy and hydrogen clearance.

    abstract::We have developed a reliable, reproducible model of hypoxia in the gerbil. 1H and 31P NMR spectroscopy demonstrates that cerebral energy metabolism is very resistant to hypoxia. Cerebral blood flow (measured by hydrogen clearance) began to increase when the arterial oxygen tension (paO2) was reduced to 40-50 mm Hg, an...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1940050109

    authors: Allen K,Busza AL,Crockard HA,Gadian DG

    更新日期:1992-01-01 00:00:00

  • Proton change of parotid glands after gustatory stimulation examined by magnetic resonance imaging.

    abstract::The aim of this study was to investigate proton changes of the parotid gland after gustatory stimulation by semi-quantitative parameters and an empirical mathematical model (EMM) using high-temporal-resolution, double-echo, echo-planar imaging (EPI). Approved by a local institutional review board, this study examined ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3885

    authors: Liu YJ,Lee YH,Chang HC,Chiu HC,Chiu TW,Hsu K,Pen CM,Hsu HH,Juan CJ

    更新日期:2018-03-01 00:00:00

  • Acquisition of ³He ventilation images, ADC, T₂* and B₁ maps in a single scan with compressed sensing.

    abstract::In imaging of human lungs with hyperpolarised noble gases, measurements of apparent diffusion coefficient (ADC) and relaxation time provide valuable information for the assessment of lung microstructure. In this work, a sequence was developed for interleaved acquisition of ventilation images, ADC, T(2)* and flip angle...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1710

    authors: Ajraoui S,Parra-Robles J,Marshall H,Deppe MH,Clemence M,Wild JM

    更新日期:2012-01-01 00:00:00

  • Longitudinal assessment of tissue properties and cardiac diffusion metrics of the ex vivo porcine heart at 7 T: Impact of continuous tissue fixation using formalin.

    abstract::In this study we aimed to assess the effects of continuous formalin fixation on diffusion and relaxation metrics of the ex vivo porcine heart at 7 T. Magnetic resonance imaging was performed on eight piglet hearts using a 7 T whole body system. Hearts were measured fresh within 3 hours of cardiac arrest followed by im...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4298

    authors: Lohr D,Terekhov M,Veit F,Schreiber LM

    更新日期:2020-07-01 00:00:00

  • Regional neurochemical profiles in the human brain measured by ¹H MRS at 7 T using local B₁ shimming.

    abstract::Increased sensitivity and chemical shift dispersion at ultra-high magnetic fields enable the precise quantification of an extended range of brain metabolites from (1)H MRS. However, all previous neurochemical profiling studies using single-voxel MRS at 7 T have been limited to data acquired from the occipital lobe wit...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1727

    authors: Emir UE,Auerbach EJ,Van De Moortele PF,Marjańska M,Uğurbil K,Terpstra M,Tkáč I,Oz G

    更新日期:2012-01-01 00:00:00

  • Spin-exchange NMR spectroscopy in studies of the kinetics of enzymes and membrane transport.

    abstract::Spin-exchange NMR techniques enable the measurement of the rates of exchange of solutes between chemically or physically distinct sites in reactions taking place at chemical equilibrium. The time scale of the events that are able to be investigated lies in the neighbourhood of 1 s. The earliest studies in this area of...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.1940030303

    authors: Kuchel PW

    更新日期:1990-06-01 00:00:00

  • NMR spectroscopic identification of cholesterol esters, plasmalogen and phenolic glycolipids as fingerprint markers of human intracranial tuberculomas.

    abstract::Detailed (1)H and (13)C NMR spectroscopy of lipid extracts from 12 human intracranial tuberculomas and two control brain tissue samples was performed to assess the role of lipids in the disease process. One-dimensional and two-dimensional NMR techniques were used to resolve the mixture of lipid components and make res...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1191

    authors: Subramanian A,Shankar Joshi B,Roy AD,Roy R,Gupta V,Dang RS

    更新日期:2008-03-01 00:00:00

  • Physiological variation of the vertebral bone marrow water T2 relaxation time.

    abstract::The aim of this study was to investigate physiological variations of the water T2 relaxation time in vertebral bone marrow with respect to age, body mass index (BMI), sex and proton density fat fraction (PDFF) based on single-voxel magnetic resonance spectroscopy (MRS) at 3 T. Multi-TE single-voxel STEAM MRS data of a...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4439

    authors: Ruschke S,Syväri J,Dieckmeyer M,Junker D,Makowski MR,Baum T,Karampinos DC

    更新日期:2020-11-17 00:00:00

  • Rapid MR relaxometry using deep learning: An overview of current techniques and emerging trends.

    abstract::Quantitative mapping of MR tissue parameters such as the spin-lattice relaxation time (T1 ), the spin-spin relaxation time (T2 ), and the spin-lattice relaxation in the rotating frame (T1ρ ), referred to as MR relaxometry in general, has demonstrated improved assessment in a wide range of clinical applications. Compar...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4416

    authors: Feng L,Ma D,Liu F

    更新日期:2020-10-15 00:00:00

  • Measuring SPIO and Gd contrast agent magnetization using 3 T MRI.

    abstract::Traditional methods of measuring magnetization in magnetic fluid samples, such as vibrating sample magnetometry (VSM), are typically limited to maximum field strengths of about 1 T. This work demonstrates the ability of MRI to measure the magnetization associated with two commercial MRI contrast agents at 3 T by compa...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1412

    authors: Cantillon-Murphy P,Wald LL,Zahn M,Adalsteinsson E

    更新日期:2009-10-01 00:00:00

  • Identification of diffuse and focal brain lesions by clinical magnetic resonance spectroscopy.

    abstract::The purpose of this paper is to facilitate the comparison of magnetic resonance (MR) spectra acquired from unknown brain lesions with published spectra in order to help identify unknown lesions in clinical settings. The paper includes lists of references for published MR spectra of various brain diseases, including py...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.1039

    authors: Kingsley PB,Shah TC,Woldenberg R

    更新日期:2006-06-01 00:00:00

  • A comparison of signal instability in 2D and 3D EPI resting-state fMRI.

    abstract::Spatiotemporally structured noise, such as physiological noise, is a potential source of artifacts in functional magnetic resonance imaging (fMRI) and is the main limiting factor for the detection of small blood oxygen level-dependent (BOLD) signal variations. fMRI was employed to detect low-frequency BOLD signal fluc...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.987

    authors: Goerke U,Möller HE,Norris DG,Schwarzbauer C

    更新日期:2005-12-01 00:00:00

  • Assessing manganese efflux using SEA0400 and cardiac T1-mapping manganese-enhanced MRI in a murine model.

    abstract::The sodium-calcium exchanger (NCX) is one of the transporters contributing to the control of intracellular calcium (Ca(2+)) concentration by normally mediating net Ca(2+) efflux. However, the reverse mode of the NCX can cause intracellular Ca(2+) concentration overload, which exacerbates the myocardial tissue injury r...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1414

    authors: Waghorn B,Yang Y,Baba A,Matsuda T,Schumacher A,Yanasak N,Hu TC

    更新日期:2009-10-01 00:00:00

  • Simultaneous MR quantification of hepatic fat content, fatty acid composition, transverse relaxation time and magnetic susceptibility for the diagnosis of non-alcoholic steatohepatitis.

    abstract::Non-alcoholic steatohepatitis (NASH) is characterized at histology by steatosis, hepatocyte ballooning and inflammatory infiltrates, with or without fibrosis. Although diamagnetic material in fibrosis and inflammation can be detected with quantitative susceptibility imaging, fatty acid composition changes in NASH rela...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3766

    authors: Leporq B,Lambert SA,Ronot M,Vilgrain V,Van Beers BE

    更新日期:2017-10-01 00:00:00

  • Continuous noninvasive monitoring of transcutaneous blood gases for a stable and persistent BOLD contrast in fMRI studies in the rat.

    abstract::The physiological status of anesthetized rats greatly influences blood oxygenation level dependent (BOLD) functional magnetic resonance imaging (fMRI). Monitoring of physiological parameters, particularly partial pressure of carbon dioxide (pCO(2)) levels in the blood, is therefore an important part in the design and ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.978

    authors: Ramos-Cabrer P,Weber R,Wiedermann D,Hoehn M

    更新日期:2005-11-01 00:00:00

  • Structure or Exchange? On the Feasibility of Chemical Exchange Detection with Balanced Steady-State Free Precession in Tissue - An In Vitro Study.

    abstract::Balanced steady-state free precession imaging has recently been suggested for chemical exchange detection (bSSFPX). The objective of this work is to investigate the contributions of microstructural, chemical shift and chemical exchange effects to the asymmetry of the bSSFP profile at field strengths of 3 T and 9.4 T. ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4200

    authors: Heule R,Deshmane A,Zaiss M,Herz K,Ehses P,Scheffler K

    更新日期:2020-03-01 00:00:00

  • In vivo detection and automatic analysis of GABA in the mouse brain with MEGA-PRESS at 9.4 T.

    abstract::The goals of this study were to develop an acquisition protocol and the analysis tools for Meshcher-Garwood point-resolved spectroscopy (MEGA-PRESS) in mouse brain at 9.4 T, to allow the in vivo detection of γ-aminobutyric acid (GABA) and to examine whether isoflurane alters GABA levels in the thalamus during anesthes...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3837

    authors: Guo J,Gang Z,Sun Y,Laine A,Small SA,Rothman DL

    更新日期:2018-01-01 00:00:00

  • Quantification issues of in vivo (1) H NMR spectroscopy of the rat brain investigated at 16.4 T.

    abstract::The accuracy and precision of the quantification of metabolite concentrations in in vivo (1) H NMR spectroscopy are affected by linewidth and signal-to-noise ratio (SNR). To study the effect of both factors in in vivo (1) H NMR spectra acquired at ultrahigh field, a reference spectrum was generated by summing nine in ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2821

    authors: Hong ST,Pohmann R

    更新日期:2013-01-01 00:00:00

  • Metabolite quantification and high-field MRS in breast cancer.

    abstract::In vivo 1H MRS is rapidly developing as a clinical tool for diagnosing and characterizing breast cancers. Many in vivo and in vitro experiments have demonstrated that alterations in concentrations of choline-containing metabolites are associated with malignant transformation. In recent years, considerable efforts have...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.1217

    authors: Haddadin IS,McIntosh A,Meisamy S,Corum C,Styczynski Snyder AL,Powell NJ,Nelson MT,Yee D,Garwood M,Bolan PJ

    更新日期:2009-01-01 00:00:00

  • Physiological properties of malignant tumours.

    abstract::It is generally accepted that tumour microcirculation, blood flow, oxygen and nutrient supply, tissue pH distribution, and the bioenergetic status--factors which are usually closely linked and which define the so-called metabolic microenvironment--can markedly influence the therapeutic response of malignant tumours to...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.1940050505

    authors: Vaupel P

    更新日期:1992-09-01 00:00:00

  • Apparent exchange rate for breast cancer characterization.

    abstract::Although diffusion MRI has shown promise for the characterization of breast cancer, it has low specificity to malignant subtypes. Higher specificity might be achieved if the effects of cell morphology and molecular exchange across cell membranes could be disentangled. The quantification of exchange might thus allow th...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3504

    authors: Lasič S,Oredsson S,Partridge SC,Saal LH,Topgaard D,Nilsson M,Bryskhe K

    更新日期:2016-05-01 00:00:00

  • MOLLI and AIR T1 mapping pulse sequences yield different myocardial T1 and ECV measurements.

    abstract::Both post-contrast myocardial T1 and extracellular volume (ECV) have been reported to be associated with diffuse interstitial fibrosis. Recently, the cardiovascular magnetic resonance (CMR) field is recognizing that post-contrast myocardial T1 is sensitive to several confounders and migrating towards ECV as a measure ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3221

    authors: Hong K,Kim D

    更新日期:2014-11-01 00:00:00