The impact of tracking system properties on the most likely path estimation in proton CT.

Abstract:

:Proton CT nowadays aims at improving hadron therapy treatment planning by mapping the stopping power of materials. In order to optimize a spatial resolution of the reconstructed images, the most likely path (MLP) of each proton can be computed. We investigated the errors in the computation of this path due to the configuration of the system, i.e. the spatial resolution of the tracking planes, their material budget, and their positioning. A method for computing the uncertainty in the estimated paths for a given system was derived. The uncertainties upon the entrance and exit of the object were propagated analytically in the path computation. This procedure was then used to evaluate the impact of each parameter, and to compare different systems. We show that the intrinsic characteristics of the system generate an uncertainty in the positions and directions of the particles propagated during the MLP computation. The spatial resolution and material budget of the trackers in particular may affect the path estimation, and thus the spatial resolution of an image.

journal_name

Phys Med Biol

authors

Bopp C,Rescigno R,Rousseau M,Brasse D

doi

10.1088/0031-9155/59/23/N197

subject

Has Abstract

pub_date

2014-12-07 00:00:00

pages

N197-210

issue

23

eissn

0031-9155

issn

1361-6560

journal_volume

59

pub_type

杂志文章
  • Prediction of positron emitter distributions for range monitoring in carbon ion therapy: an analytical approach.

    abstract::Range verification is one of the most relevant tasks in ion beam therapy. In the case of carbon ion therapy, positron emission tomography (PET) is the most widely used method for this purpose, which images the [Formula: see text]-activation following nuclear interactions of the ions with the tissue nuclei. Since the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab17f9

    authors: Hofmann T,Fochi A,Parodi K,Pinto M

    更新日期:2019-05-21 00:00:00

  • Experimental determination of the energy response of alanine pellets in the high dose rate 192Ir spectrum.

    abstract::An experimental determination of the energy correction factor for alanine/paraffin pellets in the 192Ir spectrum at varying distances from the source is presented. Alanine dosimeters were irradiated in water under full scatter conditions with a high dose rate (HDR) 192Ir source (Flexisource), using a dedicated holder....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/20/007

    authors: Schaeken B,Cuypers R,Goossens J,Van den Weyngaert D,Verellen D

    更新日期:2011-10-21 00:00:00

  • Investigation of detection limits for diffuse optical tomography systems: II. Analysis of slab and cup geometry for breast imaging.

    abstract::Using a statistical (chi-square) test on simulated data and a realistic noise model derived from the system's hardware we study the performance of diffuse optical tomography systems for fluorescence imaging. We compare the predicted smallest size of detectable lesions at various positions in slab and cup geometry and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/2/016

    authors: Ziegler R,Brendel B,Rinneberg H,Nielsen T

    更新日期:2009-01-21 00:00:00

  • Total body water measurements using resonant cavity perturbation techniques.

    abstract::A recent paper proposed a novel technique for determining the total body water (TBW) of patients suffering with abnormal hydration levels, using a resonant cavity perturbation method. Current techniques to measure TBW are limited by resolution and technical constraints. However, this new method involves measuring the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/9/013

    authors: Stone DA,Robinson MP

    更新日期:2004-05-07 00:00:00

  • MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system.

    abstract::Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab9d1

    authors: Omidvari N,Topping G,Cabello J,Paul S,Schwaiger M,Ziegler SI

    更新日期:2018-05-01 00:00:00

  • Feasibility of salvage interstitial microwave thermal therapy for prostate carcinoma following failed brachytherapy: studies in a tissue equivalent phantom.

    abstract::Thermal therapy is an experimental treatment to destroy solid tumours by heating them to temperatures ranging from 55 degrees C to 90 degrees C, inducing thermal coagulation and necrosis of the tumour. We are investigating the feasibility of interstitial microwave thermal therapy as a salvage treatment for prostate ca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/8/306

    authors: McCann C,Kumaradas JC,Gertner MR,Davidson SR,Dolan AM,Sherar MD

    更新日期:2003-04-21 00:00:00

  • Physical characterization and performance comparison of active- and passive-pixel CMOS detectors for mammography.

    abstract::We investigated the physical characteristics of two complementary metal oxide semiconductor (CMOS) mammography detectors. The detectors featured 14-bit image acquisition, 50 microm detector element (del) size and an active area of 5 cm x 5 cm. One detector was a passive-pixel sensor (PPS) with signal amplification per...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/6/022

    authors: Elbakri IA,McIntosh BJ,Rickey DW

    更新日期:2009-03-21 00:00:00

  • Reassessing the clinical efficacy of two MR quantitative DSC PWI CBF algorithms following cross-calibration with PET images.

    abstract::Clinical cerebral blood flow (CBF) maps generated through dynamic- susceptibility contrast (DSC) magnetic resonance (MR) perfusion imaging are currently cross-calibrated with PET studies. The cross-calibration is achieved by rescaling the MR CBF values so that normal white matter CBF corresponds to 22 ml/100 g/min. Ex...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/6/014

    authors: Chen JJ,Frayne R,Smith MR

    更新日期:2005-03-21 00:00:00

  • Thoracic low-dose CT image processing using an artifact suppressed large-scale nonlocal means.

    abstract::The x-ray exposure to patients has become a major concern in computed tomography (CT) and minimizing the radiation exposure has been one of the major efforts in the CT field. Due to plenty high-attenuation tissues in the human chest, under low-dose scan protocols, thoracic low-dose CT (LDCT) images tend to be severely...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2667

    authors: Chen Y,Yang Z,Hu Y,Yang G,Zhu Y,Li Y,Luo L,Chen W,Toumoulin C

    更新日期:2012-05-07 00:00:00

  • Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

    abstract::Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/90

    authors: Sisniega A,Zbijewski W,Stayman JW,Xu J,Taguchi K,Fredenberg E,Lundqvist M,Siewerdsen JH

    更新日期:2016-01-07 00:00:00

  • Range and dose verification in proton therapy using proton-induced positron emitters and recurrent neural networks (RNNs).

    abstract::Online proton range/dose verification based on measurements of proton-induced positron emitters is a promising strategy for quality assurance in proton therapy. Because of the nonlinear correlation between the dose distribution and the activity distribution of positron emitters, we aim to establish their relationship ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3564

    authors: Liu C,Li Z,Hu W,Xing L,Peng H

    更新日期:2019-09-04 00:00:00

  • The energy-dependent electron loss model for pencil beam dose kernels.

    abstract::The 'monoenergetic' electron loss model was derived in a previous work to account for pathlength straggling in the Fermi-Eyges pencil beam problem. In this paper, we extend this model to account for energy-loss straggling and secondary knock-on electron transport in order to adequately predict a depth dose curve. To m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/10/313

    authors: Chvetsov AV,Sandison GA,Yeboah C

    更新日期:2000-10-01 00:00:00

  • The response of cells in culture to fractionated radiation: a theoretical approach.

    abstract::A mathematical model has been constructed to simulate the response of cells in vitro to fractionated doses of radiation. The model is capable of describing most of the radiobiological functions that are commonly studied. Input data are measurable cell properties. The details of the model and methods of acquiring the i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/5/011

    authors: Niederer J,Cunningham JR

    更新日期:1976-09-01 00:00:00

  • Single and multiple cross sections for ionizing processes of biological molecules by protons and alpha-particle impact: a classical Monte Carlo approach.

    abstract::A classical trajectory model has been used to predict total cross sections of single and double ionizing processes (including capture processes) for several ion-biological molecule collisional systems in the intermediate and high energy range. In this work, the systems studied are water, adenine or cytosine targets io...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/N03

    authors: Abbas I,Champion C,Zarour B,Lasri B,Hanssen J

    更新日期:2008-02-21 00:00:00

  • Evaluation of a commercial radiochromatography module as an arterial blood activity monitor.

    abstract::Input functions required for positron emission tomography (PET) tracer kinetic modeling are often obtained from arterial blood. In some situations, using short-lived radiotracers, e.g. [(15)O]water, rapid sample handling is required. A method used at several facilities is to pump blood through a detector system at a c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/2/003

    authors: Laymon CM,Sashin D,Carney JP,Ruszkiewicz J,Altenburger D,Becker CR,Lopresti BJ,Mason NS,Mountz JM,Price JC,Schavey R,Mathis CA

    更新日期:2008-01-21 00:00:00

  • Positioning of a plane-parallel ionization chamber in clinical electron beams and the impact on perturbation factors.

    abstract::Current dosimetry protocols recommend the use of plane-parallel ionization chambers for the dosimetry of clinical electron beams. The necessary perturbation corrections p(wall) and p(cav) are assumed to be unity, independent of the depth of measurement and the energy of the primary electrons. To verify these assumptio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/8/011

    authors: Zink K,Wulff J

    更新日期:2009-04-21 00:00:00

  • Should image rotation be addressed during routine cone-beam CT quality assurance?

    abstract::The purpose of this study is to investigate whether quality assurance (QA) for cone-beam computed tomography (CBCT) image rotation is necessary in order to ensure the accuracy of CBCT based image-guided radiation therapy (IGRT) and adaptive radiotherapy (ART). Misregistration of angular coordinates during CBCT acquisi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/1059

    authors: Ayan AS,Lin H,Yeager C,Deville C,McDonough J,Zhu TC,Anderson N,Bar Ad V,Lu HM,Both S

    更新日期:2013-02-21 00:00:00

  • CyberArc: a non-coplanar-arc optimization algorithm for CyberKnife.

    abstract::The goal of this study is to demonstrate the feasibility of a novel non-coplanar-arc optimization algorithm (CyberArc). This method aims to reduce the delivery time of conventional CyberKnife treatments by allowing for continuous beam delivery. CyberArc uses a 4 step optimization strategy, in which nodes, beams, and c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6f92

    authors: Kearney V,Cheung JP,McGuinness C,Solberg TD

    更新日期:2017-06-26 00:00:00

  • Block matching 3D random noise filtering for absorption optical projection tomography.

    abstract::Absorption and emission optical projection tomography (OPT), alternatively referred to as optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT), are recently developed three-dimensional imaging techniques with value for developmental biology and ex vivo gene expression studies...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/18/009

    authors: Fumene Feruglio P,Vinegoni C,Gros J,Sbarbati A,Weissleder R

    更新日期:2010-09-21 00:00:00

  • Fast dose calculation in magnetic fields with GPUMCD.

    abstract::A new hybrid imaging-treatment modality, the MRI-Linac, involves the irradiation of the patient in the presence of a strong magnetic field. This field acts on the charged particles, responsible for depositing dose, through the Lorentz force. These conditions require a dose calculation engine capable of taking into con...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/16/003

    authors: Hissoiny S,Raaijmakers AJ,Ozell B,Després P,Raaymakers BW

    更新日期:2011-08-21 00:00:00

  • Simulational validation of color magnetic particle imaging (cMPI).

    abstract::Exploiting the field response of magnetic tracers, magnetic particle imaging (MPI) allows direct, local quantification of the tracer concentration in bulk structures. Here, we investigated the use of characteristic field response functions to spatially resolve the absolute concentration of multiple nanoparticle specie...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/21/6521

    authors: Han SH,Cho E,Lee DK,Cho G,Kim YR,Cho H

    更新日期:2014-11-07 00:00:00

  • Design and performance of the micro-dose calibrator.

    abstract::A new class of dose calibrator called a micro-dose calibrator, designed to measure radioactivity rates in the range between 1 kBq up to 370 kBq, has been designed and an 8 NaI(Tl)/photo multiplier tube (PMT) module prototype built to evaluate its performance. The design of the micro-dose calibrator is based on the con...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aadb3b

    authors: Adler S,Choyke P

    更新日期:2018-09-10 00:00:00

  • Response, thermal regulatory threshold and thermal breakdown threshold of restrained RF-exposed mice at 905 MHz.

    abstract::The objective of this study was the determination of the thermal regulatory and the thermal breakdown thresholds for in-tube restrained B6C3F1 and NMRI mice exposed to radiofrequency electromagnetic fields at 905 MHz. Different levels of the whole-body averaged specific absorption rate (SAR = 0, 2, 5, 7.2, 10, 12.6 an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/21/017

    authors: Ebert S,Eom SJ,Schuderer J,Apostel U,Tillmann T,Dasenbrock C,Kuster N

    更新日期:2005-11-07 00:00:00

  • Fluence correction factors in plastic phantoms for clinical proton beams.

    abstract::In recent codes of practice for reference dosimetry in clinical proton beams using ionization chambers, it is recommended to perform the measurement in a water phantom. However, in situations where the positioning accuracy is very critical, it could be more convenient to perform the measurement in a plastic phantom. I...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/17/302

    authors: Palmans H,Symons JE,Denis JM,de Kock EA,Jones DT,Vynckier S

    更新日期:2002-09-07 00:00:00

  • Measurement of the dielectric properties of the epidermis and dermis at frequencies from 0.5 GHz to 110 GHz.

    abstract::Numerous studies have reported the measurements of the dielectric properties of the skin. Clarifying the manner in which the human body interacts with electromagnetic waves is essential for medical research and development, as well as for the safety assessment of electromagnetic wave exposure. The skin comprises sever...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/16/4739

    authors: Sasaki K,Wake K,Watanabe S

    更新日期:2014-08-21 00:00:00

  • Pulse shape discrimination and classification methods for continuous depth of interaction encoding PET detectors.

    abstract::In previous work we demonstrated the potential of positron emission tomography (PET) detectors with depth-of-interaction (DOI) encoding capability based on phosphor-coated crystals. A DOI resolution of 8 mm full-width at half-maximum was obtained for 20 mm long scintillator crystals using a delayed charge integration ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6571

    authors: Roncali E,Phipps JE,Marcu L,Cherry SR

    更新日期:2012-10-21 00:00:00

  • A 3D point-kernel multiple scatter model for parallel-beam SPECT based on a gamma-ray buildup factor.

    abstract::A three-dimensional (3D) point-kernel multiple scatter model for point spread function (PSF) determination in parallel-beam single-photon emission computed tomography (SPECT), based on a dose gamma-ray buildup factor, is proposed. This model embraces nonuniform attenuation in a voxelized object of imaging (patient bod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/19/004

    authors: Marinkovic P,Ilic R,Spaic R

    更新日期:2007-10-07 00:00:00

  • An automatic algorithm to exploit the symmetries of the system response matrix in positron emission tomography iterative reconstruction.

    abstract::Positron emission tomography (PET) iterative 3D reconstruction is a very computational demanding task. One of the main issues of the iterative reconstruction concerns the management of the system response matrix (SRM). The SRM models the relationship between the projection and the voxel space and its memory footprint ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae12b

    authors: Camarlinghi N,Sportelli G,Guerra AD,Belcari N

    更新日期:2018-09-28 00:00:00

  • Low-frequency conductivity tensor imaging with a single current injection using DT-MREIT.

    abstract::Diffusion tensor - magnetic resonance electrical impedance tomography (DT-MREIT) is an imaging modality to obtain low-frequency anisotropic conductivity distribution employing diffusion tensor imaging (DTI) and magnetic resonance electrical impedance tomography (MREIT) techniques. DT-MREIT is based on the linear relat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abddcf

    authors: Sadighi M,Sisman M,Acikgoz BC,Eroglu HH,Eyuboglu BM

    更新日期:2021-01-20 00:00:00

  • Preliminary evaluation of second harmonic direct detection scheme for low-dose range in alanine/EPR dosimetry.

    abstract::The usefulness of a direct detection scheme of the second harmonic (2h) overmodulated signal from irradiated alanine in EPR dosimetry was studied. For this purpose, a group of DL-alanine/paraffin cylindrical pellets was produced. The dosimeters were irradiated with a 60Co radiotherapy gamma source with doses of 0.05, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/8/309

    authors: Chen F,Graeff CF,Baffa O

    更新日期:2002-04-21 00:00:00