Echo time-dependent quantitative susceptibility mapping contains information on tissue properties.

Abstract:

PURPOSE:Magnetic susceptibility is a physical property of matter that varies depending on chemical composition and abundance of different molecular species. Interest is growing in mapping of magnetic susceptibility in the human brain using magnetic resonance imaging techniques, but the influences affecting the mapped values are not fully understood. METHODS:We performed quantitative susceptibility mapping on 7 Tesla (T) multiple echo time gradient recalled echo data and evaluated the trend in 10 regions of the human brain. Temporal plots of susceptibility were performed in the caudate, pallidum, putamen, thalamus, insula, red nucleus, substantia nigra, internal capsule, corpus callosum, and fornix. We implemented an existing three compartment signal model and used optimization to fit the experimental result to assess the influences that could be responsible for our findings. RESULTS:The temporal trend in susceptibility is different for different brain regions, and subsegmentation of specific regions suggests that differences are likely to be attributable to variations in tissue structure and composition. Using a signal model, we verified that a nonlinear temporal behavior in experimentally computed susceptibility within imaging voxels may be the result of the heterogeneous composition of tissue properties. CONCLUSIONS:Decomposition of voxel constituents into meaningful parameters may lead to informative measures that reflect changes in tissue microstructure. Magn Reson Med 77:1946-1958, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

journal_name

Magn Reson Med

authors

Sood S,Urriola J,Reutens D,O'Brien K,Bollmann S,Barth M,Vegh V

doi

10.1002/mrm.26281

subject

Has Abstract

pub_date

2017-05-01 00:00:00

pages

1946-1958

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

77

pub_type

杂志文章
  • Fast anatomical imaging of the heart and assessment of myocardial perfusion with arrhythmia insensitive magnetization preparation.

    abstract::A new contrast preparation based on modified driven equilibrium Fourier transfer is introduced and evaluated for generation of T1-weighted images for assessment of the myocardial perfusion with contrast agent first-pass kinetics. The new preparation scheme produces T1 contrast with insensitivity to arrhythmias in pros...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340408

    authors: Tsekos NV,Zhang Y,Merkle H,Wilke N,Jerosch-Herold M,Stillman A,Uğurbil K

    更新日期:1995-10-01 00:00:00

  • Phase-updated regularized SENSE for navigator-free multishot diffusion imaging.

    abstract:PURPOSE:Either SENSE+CG or POCS-ICE methods can be used to correct for motion-induced phase errors in navigator-free multishot diffusion imaging. SENSE+CG has the advantage of a fast convergence, however, occasionally the convergence can be unstable, thus degrading the image quality. POCS-ICE has a stable convergence a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26361

    authors: Hu Z,Ma X,Truong TK,Song AW,Guo H

    更新日期:2017-07-01 00:00:00

  • Accurate multislice gradient echo T(1) measurement in the presence of non-ideal RF pulse shape and RF field nonuniformity.

    abstract::A methodology is presented for estimating T(1) using a two-point technique with a standard multislice gradient echo sequence. The method explicitly corrects for the shape of the RF pulse and for spatial variations in transmitted RF field intensity. Including these factors in the calculation of T(1) gives a substantial...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1112

    authors: Parker GJ,Barker GJ,Tofts PS

    更新日期:2001-05-01 00:00:00

  • Evaluation of acute brain edema using quantitative magnetic resonance imaging: effects of pretreatment with dexamethasone.

    abstract::We developed a quantitative magnetic resonance imaging method to permit a rapid assessment of brain water content during osmotic brain edema produced by intraperitoneal (ip) injection of distilled water. Fifteen minutes after water injection, the normalized mean image intensity (MIn) from a spin-echo pulse sequence (T...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910240107

    authors: Olson JE,Katz-Stein A,Reo NV,Jolesz FA

    更新日期:1992-03-01 00:00:00

  • Strain-dependent T1 relaxation profiles in articular cartilage by MRI at microscopic resolutions.

    abstract::To investigate the dependency of T(1) relaxation on mechanical strain in articular cartilage, quantitative magnetic resonance T(1) imaging experiments were carried out on cartilage before/after the tissue was immersed in gadolinium contrast agent and when the tissue was being compressed (up to ∼ 48% strains). The spat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22933

    authors: Xia Y,Wang N,Lee J,Badar F

    更新日期:2011-06-01 00:00:00

  • Phase constrained encoding (PACE): a technique for MRI in large static field inhomogeneities.

    abstract::In spin echo imaging, magnetization is assigned to a location defined by its frequency of rotation. In the presence of a static magnetic field inhomogeneity, however, this location does not correspond to the true location of the magnetization. This paper describes a magnetic resonance imaging technique called phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330407

    authors: Kim JK,Plewes DB,Henkelman RM

    更新日期:1995-04-01 00:00:00

  • Gradient, high-resolution, magic-angle spinning nuclear magnetic resonance spectroscopy of human adipocyte tissue.

    abstract::The recently developed technique of gradient, high-resolution magic-angle spinning NMR (g-hr-MAS-NMR) spectroscopy was applied to the study of ex vivo human lipoma and liposarcoma tissue. Compared with conventional 1H-NMR, the g-hr-MAS method yielded a large improvement in spectral resolution and permitted the detecti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380307

    authors: Millis KK,Maas WE,Cory DG,Singer S

    更新日期:1997-09-01 00:00:00

  • View-ordering in radial fast spin-echo imaging.

    abstract::Radial MRI sequences are frequently used to obtain images with reduced sensitivity to motion. To decrease imaging time, multiple spin-echo acquisitions can be incorporated into radial sequences. In this case, different radial lines of Fourier data have different TE times and the resulting images can contain streaking ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20031

    authors: Theilmann RJ,Gmitro AF,Altbach MI,Trouard TP

    更新日期:2004-04-01 00:00:00

  • Motion-adaptive spatio-temporal regularization for accelerated dynamic MRI.

    abstract::Accelerated magnetic resonance imaging techniques reduce signal acquisition time by undersampling k-space. A fundamental problem in accelerated magnetic resonance imaging is the recovery of quality images from undersampled k-space data. Current state-of-the-art recovery algorithms exploit the spatial and temporal stru...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24524

    authors: Asif MS,Hamilton L,Brummer M,Romberg J

    更新日期:2013-09-01 00:00:00

  • Functional mapping of the human somatosensory cortex with echo-planar MRI.

    abstract::The somatotopical organization of the human somatosensory cortex was analyzed with echo-planar imaging at 1.5 Tesla, utilizing deoxyhemoglobin as an endogenous contrast medium. Scrubbing stimulation at a frequency of 3 Hz was applied to one of three cutaneous areas: toes, fingertips, and tongue tip. Parasagittal echo-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330521

    authors: Sakai K,Watanabe E,Onodera Y,Itagaki H,Yamamoto E,Koizumi H,Miyashita Y

    更新日期:1995-05-01 00:00:00

  • Dissolved hyperpolarized xenon-129 MRI in human kidneys.

    abstract:PURPOSE:To assess the feasibility of using dissolved hyperpolarized xenon-129 (129 Xe) MRI to study renal physiology in humans at 3 T. METHODS:Using a flexible transceiver RF coil, dynamic and spatially resolved 129 Xe spectroscopy was performed in the abdomen after inhalation of hyperpolarized 129 Xe gas with 3 healt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27923

    authors: Chacon-Caldera J,Maunder A,Rao M,Norquay G,Rodgers OI,Clemence M,Puddu C,Schad LR,Wild JM

    更新日期:2020-01-01 00:00:00

  • Quantitative susceptibility mapping detects abnormalities in cartilage canals in a goat model of preclinical osteochondritis dissecans.

    abstract:PURPOSE:To use quantitative susceptibility mapping (QSM) to investigate changes in cartilage canals in the distal femur of juvenile goats after their surgical transection. METHODS:Chondronecrosis was surgically induced in the right medial femoral condyles of four 4-day-old goats. Both the operated and control knees we...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26214

    authors: Wang L,Nissi MJ,Toth F,Johnson CP,Garwood M,Carlson CS,Ellermann J

    更新日期:2017-03-01 00:00:00

  • Compartment size estimation with double wave vector diffusion-weighted imaging.

    abstract::Double wave vector diffusion weighting uses gradients along two different directions between excitation and acquisition. It has been shown theoretically that for restricted diffusion the signal amplitude in such an experiment can depend on the angle between the two gradient vectors. The highest amplitude is obtained w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21514

    authors: Koch MA,Finsterbusch J

    更新日期:2008-07-01 00:00:00

  • Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain.

    abstract::Magnetic field homogeneity is of major concern for in vivo spectroscopy, and with the increased use of volumetric chemical shift imaging (CSI) techniques, the ability to shim over a large volume of tissue is now one of the primary limiting constraints in performing these studies. In vivo shimming is routinely performe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400307

    authors: Spielman DM,Adalsteinsson E,Lim KO

    更新日期:1998-09-01 00:00:00

  • Investigation of human cervical and upper thoracic spinal cord motion: implications for imaging spinal cord structure and function.

    abstract::Spinal cord (SC) motion is thought to be the dominant source of error in current diffusion and spinal functional MRI (fMRI) methods. However, until now, such motion has not been well characterized in three dimensions. While previous studies have predominantly examined motion in the superior/inferior (S/I) direction, t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21260

    authors: Figley CR,Stroman PW

    更新日期:2007-07-01 00:00:00

  • Diffusion sensitivity of 3D-GRASE in arterial spin labeling perfusion.

    abstract:PURPOSE:To evaluate the role of true diffusion and flow-related pseudodiffusion in cerebral blood flow (CBF) quantification using arterial spin labeling (ASL) with single-shot or segmented 3D gradient and spin echo (GRASE) readouts. THEORY:The extended phase graph (EPG) algorithm, originally designed to model the effe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27058

    authors: He X,Wengler K,Schweitzer ME

    更新日期:2018-08-01 00:00:00

  • Perturbation of longitudinal relaxation rate in rotating frame (PLRF) analysis for quantification of chemical exchange saturation transfer signal in a transient state.

    abstract:PURPOSE:To develop a novel analytical method for quantification of chemical exchange saturation transfer (CEST) in the transient state. The proposed method aims to reduce the effects of non-chemical-exchange (non-CE) parameters on the CEST signal, emphasizing the effect of chemical exchange. METHODS:The difference in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26559

    authors: Wang Y,Zhang Y,Zhao X,Wu B,Gao JH

    更新日期:2017-11-01 00:00:00

  • Measurement of 129Xe gas apparent diffusion coefficient anisotropy in an elastase-instilled rat model of emphysema.

    abstract::Hyperpolarized noble gas ((3)He and (129)Xe) apparent diffusion coefficient (ADC) measurements have shown remarkable sensitivity to microstructural (i.e., alveolar) changes in the lung, particularly emphysema. The ADC of hyperpolarized noble gases depends strongly on the diffusion time (Δ), and (3)He ADC has been show...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24224

    authors: Boudreau M,Xu X,Santyr GE

    更新日期:2013-01-01 00:00:00

  • Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP.

    abstract::Flow-independent angiography is a non-contrast-enhanced technique that can generate vessel contrast even with reduced blood flow in the lower extremities. A method is presented for producing these angiograms with magnetization-prepared balanced steady-state free precession (bSSFP). Because bSSFP yields bright fat sign...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21921

    authors: Cukur T,Lee JH,Bangerter NK,Hargreaves BA,Nishimura DG

    更新日期:2009-06-01 00:00:00

  • Apparent propagator anisotropy from single-shell diffusion MRI acquisitions.

    abstract:PURPOSE:The apparent propagator anisotropy (APA) is a new diffusion MRI metric that, while drawing on the benefits of the ensemble averaged propagator anisotropy (PA) compared to the fractional anisotropy (FA), can be estimated from single-shell data. THEORY AND METHODS:Computation of the full PA requires acquisition ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28620

    authors: Aja-Fernández S,Tristán-Vega A,Jones DK

    更新日期:2020-12-13 00:00:00

  • Selective excitation of two-dimensional arbitrarily shaped voxels with parallel excitation in spectroscopy.

    abstract::Parallel excitation is being studied intensively for applications in MR imaging and in particular for selecting arbitrary shapes as regions of interest. In this work, parallel excitation was applied to arbitrarily shaped voxel selection in spectroscopy and investigated for different excitation k-space trajectories (ra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23018

    authors: Snyder J,Haas M,Hennig J,Zaitsev M

    更新日期:2012-02-01 00:00:00

  • Resolution-recovery for EPR imaging of free radical molecules in mice.

    abstract::A method of post-processing to enhance the image resolution of the distribution of free radical molecules obtained with continuous-wave electron paramagnetic resonance (CW-EPR) imaging is reported. The low spatial resolution of EPR imaging, which has created difficulties in biomedical applications, was overcome by the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22029

    authors: Ikebata Y,Sato-Akaba H,Aoyama T,Fujii H,Itoh K,Hirata H

    更新日期:2009-09-01 00:00:00

  • A 32-channel receive array coil for bilateral breast imaging and spectroscopy at 7T.

    abstract:PURPOSE:This work describes the construction and evaluation of a bilateral 32-channel receive array for breast imaging at 7T. METHODS:The receive array consisted of 32 receive coils, placed on two 3D-printed hemispherical formers. Each side of the receive array consisted of 16 receive loops, each loop having a corresp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28425

    authors: Del Bosque R,Cui J,Ogier S,Cheshkov S,Dimitrov IE,Malloy C,Wright SM,McDougall M

    更新日期:2021-01-01 00:00:00

  • Dynamic liver imaging with iron oxide agents: effects of size and biodistribution on contrast.

    abstract::In vivo effective relaxation rates in normal rat liver were evaluated for four dextran coated iron oxide agents: monocrystalline iron oxide nanocolloid (MION) with a mean particle diameter of 3.9 nm, a polycrystalline agent (PION) with a larger mean diameter of 12 nm, and these two agents labeled with the asialofetuin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370613

    authors: Mandeville JB,Moore J,Chesler DA,Garrido L,Weissleder R,Weisskoff RM

    更新日期:1997-06-01 00:00:00

  • Automatic vessel removal in gliomas from dynamic susceptibility contrast imaging.

    abstract::The presence of macroscopic vessels within the tumor region is a potential confounding factor in MR-based dynamic susceptibility contrast (DSC)-enhanced glioma grading. In order to distinguish between such vessels and the elevated cerebral blood volume (CBV) of brain tumors, we propose a vessel segmentation technique ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21944

    authors: Emblem KE,Due-Tonnessen P,Hald JK,Bjornerud A

    更新日期:2009-05-01 00:00:00

  • Design and construction of an innovative brain phantom prototype for MRI.

    abstract:PURPOSE:The purpose of this project was to construct a physical brain phantom for MRI, mimicking structure and T1 relaxation properties of white matter (WM) and gray matter (GM). METHODS:The phantom design comprised 2 compartments, 1 resembling the WM and 1 resembling the GM. Their T1 relaxation times, as assessed usi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27464

    authors: Altermatt A,Santini F,Deligianni X,Magon S,Sprenger T,Kappos L,Cattin P,Wuerfel J,Gaetano L

    更新日期:2019-02-01 00:00:00

  • Template-based field map prediction for rapid whole brain B0 shimming.

    abstract:PURPOSE:In typical MRI protocols, time is spent acquiring a field map to calculate the shim settings for best image quality. We propose a fast template-based field map prediction method that yields near-optimal shims without measuring the field. METHODS:The template-based prediction method uses prior knowledge of the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27020

    authors: Shi Y,Vannesjo SJ,Miller KL,Clare S

    更新日期:2018-07-01 00:00:00

  • Design and evaluation of quantitative MRI phantoms to mimic the simultaneous presence of fat, iron, and fibrosis in the liver.

    abstract:PURPOSE:To design, construct, and evaluate quantitative MR phantoms that mimic MRI signals from the liver with simultaneous control of three parameters: proton-density fat fraction (PDFF), R 2 ∗ ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28452

    authors: Zhao R,Hamilton G,Brittain JH,Reeder SB,Hernando D

    更新日期:2021-02-01 00:00:00

  • The phenomenon of separate intra- and extracellular resonances of difluorophosphate in 31P and 19F NMR spectra of erythrocytes.

    abstract::Trifluoroacetate and trifluoroacetamide, when added to a suspension of human red blood cells, give rise to separate 19F NMR signals from the intra- and extracellular species. This phenomenon has recently been exploited for measuring the membrane potential of erythrocytes. However, the separation of the peaks was incor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180119

    authors: Xu AS,Potts JR,Kuchel PW

    更新日期:1991-03-01 00:00:00

  • Image reconstruction algorithm for motion insensitive MR Fingerprinting (MRF): MORF.

    abstract:PURPOSE:The purpose of this study is to increase the robustness of MR fingerprinting (MRF) toward subject motion. METHODS:A novel reconstruction algorithm, MOtion insensitive MRF (MORF), was developed, which uses an iterative reconstruction based retrospective motion correction approach. Each iteration loops through t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27227

    authors: Mehta BB,Ma D,Pierre EY,Jiang Y,Coppo S,Griswold MA

    更新日期:2018-12-01 00:00:00