A model-based approach to investigate the effect of elevated interstitial fluid pressure on strain elastography.

Abstract:

:Finite element (FE) modeling provides a useful tool to understand the mechanical behavior of complex tissues, such as cancers, in a variety of testing conditions. Although a number of numerical and analytical models for cancerous tumors are retrievable in the literature, none of these models is capable of completely describing the behavior of a cancer embedded in a normal tissue in the conditions typical for an ultrasound elastography experiment. In this paper, we first design and implement a realistic FE model of the mechanical behavior of a cancer embedded in a normal tissue under ultrasound elastography testing conditions. In addition to the commonly used tissue mechanical properties, for the cancer, elevated interstitial fluid pressure (IFP) is incorporated in the model. IFP is a parameter of great clinical significance, but it is not typically considered in elastographic models of tumors. The developed model is then used to thoroughly study the effect of IFP on the axial, lateral and volumetric strains inside the tumor. The results of this study demonstrate that the presence of the IFP affects both the temporal and spatial distributions of the axial, lateral, volumetric strains and related elastographic parameters. Thus, these results lead to two important considerations: (1) that a correct interpretation of experimental elastographic data need a clear understanding of the effect of the IFP on the obtained elastograms and (2) that this IFP-dependent alteration of the elastographic parameters may provide an opportunity to non-invasively gain localized information about this clinically relevant parameter.

journal_name

Phys Med Biol

authors

Islam MT,Reddy JN,Righetti R

doi

10.1088/1361-6560/aae572

subject

Has Abstract

pub_date

2018-10-24 00:00:00

pages

215011

issue

21

eissn

0031-9155

issn

1361-6560

journal_volume

63

pub_type

杂志文章
  • A depth-encoding PET detector for high resolution PET using 1 mm SiPMs.

    abstract::A dual-ended readout PET detector based on two Hamamatsu 16 × 16 arrays of 1 × 1 mm2 SiPMs coupled to both ends of a 25 × 25 array of 0.69 × 0.69 × 20 mm3 polished LYSOs was evaluated in terms of flood histogram, energy resolution, timing resolution, and DOI resolution. The SiPM arrays have a pitch size of 1.2 mm. Eac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9fc9

    authors: Du J,Bai X,Cherry SR

    更新日期:2020-08-19 00:00:00

  • Development and validation of RAYDOSE: a Geant4-based application for molecular radiotherapy.

    abstract::We developed and validated a Monte-Carlo-based application (RAYDOSE) to generate patient-specific 3D dose maps on the basis of pre-treatment imaging studies. A CT DICOM image is used to model patient geometry, while repeated PET scans are employed to assess radionuclide kinetics and distribution at the voxel level. In...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/8/2491

    authors: Marcatili S,Pettinato C,Daniels S,Lewis G,Edwards P,Fanti S,Spezi E

    更新日期:2013-04-21 00:00:00

  • Assessment of histotripsy-induced liquefaction with diagnostic ultrasound and magnetic resonance imaging in vitro and ex vivo.

    abstract::Histotripsy is a therapeutic ultrasound modality under development to liquefy tissue mechanically via bubble clouds. Image guidance of histotripsy requires both quantification of the bubble cloud activity and accurate delineation of the treatment zone. In this study, magnetic resonance (MR) and diagnostic ultrasound i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab143f

    authors: Anthony GJ,Bollen V,Hendley S,Antic T,Sammet S,Bader KB

    更新日期:2019-05-02 00:00:00

  • Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method.

    abstract::To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/2/014

    authors: Shimozato T,Tabushi K,Kitoh S,Shiota Y,Hirayama C,Suzuki S

    更新日期:2007-01-21 00:00:00

  • Application of the Monte Carlo integration (MCI) method for calculation of the anisotropy of 192Ir brachytherapy sources.

    abstract::Source anisotropy is a very important factor in the brachytherapy quality assurance of high-dose rate (HDR) 192Ir afterloading stepping sources. If anisotropy is not taken into account then doses received by a brachytherapy patient in certain directions can be in error by a clinically significant amount. Experimental ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/6/029

    authors: Baltas D,Giannouli S,Garbi A,Diakonos F,Geramani K,Ioannidis GT,Tsalpatouros A,Uzunoglu N,Kolotas C,Zamboglou N

    更新日期:1998-06-01 00:00:00

  • A dedicated phantom design for positron emission mammography performance evaluation.

    abstract::A standard protocol for performance evaluation of positron emission mammography (PEM) systems has not yet been established. In this work we propose a methodology based on the design of specific phantoms for this imaging modality with component dimensions in accordance with typical breast lesion sizes together with the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba7d1

    authors: Torres-Urzúa LF,Alva-Sanchez H,Martinez-Davalos A,García-Pérez FO,Peruyero-Rivas RM,Rodriguez-Villafuerte M

    更新日期:2020-07-21 00:00:00

  • Simulation of voltage-sensitive optical signals in three-dimensional slabs of cardiac tissue: application to transillumination and coaxial imaging methods.

    abstract::Voltage-sensitive dyes are an important tool in visualizing electrical activity in cardiac tissue. Until today, they have mainly been applied in cardiac electrophysiology to subsurface imaging. In the present study, we assess different imaging methods used in optical tomography with respect to their effectiveness in v...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/2/003

    authors: Bernus O,Wellner M,Mironov SF,Pertsov AM

    更新日期:2005-01-21 00:00:00

  • Variation of the dielectric properties of tissues with age: the effect on the values of SAR in children when exposed to walkie-talkie devices.

    abstract::In vitro dielectric properties of ageing porcine tissues were measured in the frequency range of 50 MHz-20 GHz, and the total combined uncertainties of the measurements were assessed. The results show statistically significant reduction with age in both permittivity and conductivity of 10 out of 15 measured tissues. A...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/2/004

    authors: Peyman A,Gabriel C,Grant EH,Vermeeren G,Martens L

    更新日期:2009-01-21 00:00:00

  • Tumour oxygen dynamics measured simultaneously by near-infrared spectroscopy and 19F magnetic resonance imaging in rats.

    abstract::Simultaneous near-infrared spectroscopy (NIRS) and magnetic resonance imaging (MRI) were used to investigate the correlation between tumour vascular oxygenation and tissue oxygen tension dynamics in rat breast 13762NF tumours with respect to hyperoxic gas breathing. NIRS directly detected global variations in the oxyg...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/1/004

    authors: Xia M,Kodibagkar V,Liu H,Mason RP

    更新日期:2006-01-07 00:00:00

  • Automatic classification of DMSA scans using an artificial neural network.

    abstract::DMSA imaging is carried out in nuclear medicine to assess the level of functional renal tissue in patients. This study investigated the use of an artificial neural network to perform diagnostic classification of these scans. Using the radiological report as the gold standard, the network was trained to classify DMSA s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1789

    authors: Wright JW,Duguid R,McKiddie F,Staff RT

    更新日期:2014-04-07 00:00:00

  • SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes.

    abstract::A software program, SpekCalc, is presented for the calculation of x-ray spectra from tungsten anode x-ray tubes. SpekCalc was designed primarily for use in a medical physics context, for both research and education purposes, but may also be of interest to those working with x-ray tubes in industry. Noteworthy is the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/19/N01

    authors: Poludniowski G,Landry G,DeBlois F,Evans PM,Verhaegen F

    更新日期:2009-10-07 00:00:00

  • Calibration and analysis of a multimodal micro-CT and structured light imaging system for the evaluation of excised breast tissue.

    abstract::A multimodal micro-computed tomography (CT) and multi-spectral structured light imaging (SLI) system is introduced and systematically analyzed to test its feasibility to aid in margin delineation during breast conserving surgery (BCS). Phantom analysis of the micro-CT yielded a signal-to-noise ratio of 34, a contrast ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa94b6

    authors: McClatchy DM,Rizzo EJ,Meganck J,Kempner J,Vicory J,Wells WA,Paulsen KD,Pogue BW

    更新日期:2017-11-10 00:00:00

  • A modular Geant4 model of Leksell Gamma Knife Perfexion™.

    abstract::This work presents a Monte Carlo model of Leksell Gamma Knife Perfexion as well as the main parameters of the dose distribution in the standard phantom obtained using this model. The model is developed in the Geant4 simulation toolkit in a modular way which enables its reuse in other Perfexion studies. Large phase spa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/24/7609

    authors: Pipek J,Novotný J,Novotný J,Kozubíková P

    更新日期:2014-12-21 00:00:00

  • W values and other transport data on low energy electrons in tissue equivalent gas.

    abstract::The degradation of low energy electrons in a methane based, tissue equivalent gas was studied experimentally by ionization chamber experiments and theoretically by Monte Carlo electron transport simulation in the energy range between 25 eV and 5 keV. From measured ionization yields and calculated ionization and energy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/5/008

    authors: Waibel E,Grosswendt B

    更新日期:1992-05-01 00:00:00

  • Response, thermal regulatory threshold and thermal breakdown threshold of restrained RF-exposed mice at 905 MHz.

    abstract::The objective of this study was the determination of the thermal regulatory and the thermal breakdown thresholds for in-tube restrained B6C3F1 and NMRI mice exposed to radiofrequency electromagnetic fields at 905 MHz. Different levels of the whole-body averaged specific absorption rate (SAR = 0, 2, 5, 7.2, 10, 12.6 an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/21/017

    authors: Ebert S,Eom SJ,Schuderer J,Apostel U,Tillmann T,Dasenbrock C,Kuster N

    更新日期:2005-11-07 00:00:00

  • A method of improving the spatial resolution of treatments that involve a multileaf collimator.

    abstract::In this paper we present a novel method of reducing the dosimetric effects of the finite leaf width of a multileaf collimator (MLC) in conformal and intensity modulated radiotherapy (IMRT). This is achieved by decomposing the required high-resolution fluence distribution into two orthogonal components, which are deliv...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/3/304

    authors: Evans PM,Partridge M

    更新日期:2000-03-01 00:00:00

  • Modeling late rectal toxicities based on a parameterized representation of the 3D dose distribution.

    abstract::Many models exist for predicting toxicities based on dose-volume histograms (DVHs) or dose-surface histograms (DSHs). This approach has several drawbacks as firstly the reduction of the dose distribution to a histogram results in the loss of spatial information and secondly the bins of the histograms are highly correl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/7/013

    authors: Buettner F,Gulliford SL,Webb S,Partridge M

    更新日期:2011-04-07 00:00:00

  • Characterization of single α-tracks by photoresist detection and AFM analysis-focus on biomedical science and technology.

    abstract::The interactions between energetic ions and biological and/or organic target materials have recently attracted theoretical and experimental attention, due to their implications for detector and device technologies, and for therapeutic applications. Most of the attention has focused on detection of the primary ionizati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/21/7673

    authors: Falzone N,Myhra S,Chakalova R,Hill MA,Thomson J,Vallis KA

    更新日期:2013-11-07 00:00:00

  • Development of the complex permittivity measurement system for high-loss biological samples using the free space method in quasi-millimeter and millimeter wave bands.

    abstract::The free space method using a pair of lens antennas was modified for the complex permittivity measurement of biological samples from 20 to 110 GHz. Two methodologies were used to obtain the complex permittivities by the free space method, which were based on the reflection and transmission coefficients. The measuremen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/5/1625

    authors: Sasaki K,Segawa H,Mizuno M,Wake K,Watanabe S,Hashimoto O

    更新日期:2013-03-07 00:00:00

  • Estimation of the absorption coefficients of two-layered media by a simple method using spatially and time-resolved reflectances.

    abstract::Our newly developed method using spatially and time-resolved reflectances can easily estimate the absorption coefficients of each layer in a two-layered medium if the thickness of the upper layer and the reduced scattering coefficients of the two layers are known a priori. We experimentally validated this method using...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/16/014

    authors: Shimada M,Sato C,Hoshi Y,Yamada Y

    更新日期:2009-08-21 00:00:00

  • A basic dosimetric study of PRESAGE: the effect of different amounts of fabricating components on the sensitivity and stability of the dosimeter.

    abstract::Over the past few years there has been much interest in the development of three-dimensional dosimeters to determine the complex absorbed dose distribution in modern radiotherapy techniques such as IMRT and IGRT. In routine methods used for three-dimensional dosimetry, polymer gels are commonly used. Recently, a novel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/3/023

    authors: Mostaar A,Hashemi B,Zahmatkesh MH,Aghamiri SM,Mahdavi SR

    更新日期:2010-02-07 00:00:00

  • Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters.

    abstract::Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range invest...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/24/307

    authors: Mather ML,De Deene Y,Whittaker AK,Simon GP,Rutgers R,Baldock C

    更新日期:2002-12-21 00:00:00

  • Feasibility study of range verification based on proton-induced acoustic signals and recurrent neural network.

    abstract::Range verification in proton therapy is a critical quality assurance task. We studied the feasibility of online range verification based on proton-induced acoustic signals, using a bidirectional long-short-term-memory recurrent neural network and various signal processing techniques. Dose distribution of 1D pencil pro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaa5e

    authors: Yao S,Hu Z,Zhang X,Lou E,Liang Z,Wang Y,Peng H

    更新日期:2020-11-05 00:00:00

  • Convex reformulation of biologically-based multi-criteria intensity-modulated radiation therapy optimization including fractionation effects.

    abstract::Finding fluence maps for intensity-modulated radiation therapy (IMRT) can be formulated as a multi-criteria optimization problem for which Pareto optimal treatment plans exist. To account for the dose-per-fraction effect of fractionated IMRT, it is desirable to exploit radiobiological treatment plan evaluation criteri...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/22/006

    authors: Hoffmann AL,den Hertog D,Siem AY,Kaanders JH,Huizenga H

    更新日期:2008-11-21 00:00:00

  • Automatic generation of time resolved motion vector fields of coronary arteries and 4D surface extraction using rotational x-ray angiography.

    abstract::Rotational coronary angiography provides a multitude of x-ray projections of the contrast agent enhanced coronary arteries along a given trajectory with parallel ECG recording. These data can be used to derive motion information of the coronary arteries including vessel displacement and pulsation. In this paper, a ful...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/1/004

    authors: Jandt U,Schäfer D,Grass M,Rasche V

    更新日期:2009-01-07 00:00:00

  • Measurement of scattered radiation in a volumetric 64-slice CT scanner using three experimental techniques.

    abstract::Compton scatter poses a significant threat to volumetric x-ray computed tomography, bringing cupping and streak artefacts thus impacting qualitative and quantitative imaging procedures. To perform appropriate scatter compensation, it is necessary to estimate the magnitude and spatial distribution of x-ray scatter. The...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/8/010

    authors: Akbarzadeh A,Ay MR,Ghadiri H,Sarkar S,Zaidi H

    更新日期:2010-04-21 00:00:00

  • Radiation dose factors for alpha-emitters in osteons and some considerations on dose non-uniformity ratios and relative distribution factors.

    abstract::Dose factors for locations within a tissue-filled cylindrical cavity bounded by an infinite medium of bone labelled with an alpha-emitter are calculated by means of a Monte Carlo procedure. The calculational approach is general and allows us to determine dose factors for specific distances or target volumes defined by...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/3/007

    authors: Polig E

    更新日期:1989-03-01 00:00:00

  • A volume of intersection approach for on-the-fly system matrix calculation in 3D PET image reconstruction.

    abstract::The aim of this study is the evaluation of on-the-fly volume of intersection computation for system's geometry modelling in 3D PET image reconstruction. For this purpose we propose a simple geometrical model in which the cubic image voxels on the given Cartesian grid are approximated with spheres and the rectangular t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/3/561

    authors: Lougovski A,Hofheinz F,Maus J,Schramm G,Will E,van den Hoff J

    更新日期:2014-02-07 00:00:00

  • An automated method for adaptive radiation therapy for prostate cancer patients using continuous fiducial-based tracking.

    abstract::Electromagnetic tracking technology is primarily used for continuous prostate localization during radiotherapy, but offers potential value for evaluation of dosimetric coverage and adequacy of treatment for dynamic targets. We developed a highly automated method for daily computation of cumulative dosimetric effects o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/1/005

    authors: Noel CE,Santanam L,Olsen JR,Baker KW,Parikh PJ

    更新日期:2010-01-07 00:00:00

  • Applicators for generating ultrasound-induced hyperthermia in neoplastic tumours and for use in ultrasound physiotherapy.

    abstract::Ultrasound in the low megahertz frequency range is used by physiotherapists to treat a variety of conditions. The treatments reduce swelling, reduce pain and increase movement at joints. Ultrasound is now also beginning to be used to treat malignant tumours. The tumours are heated to temperatures between 42 degrees an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/11/019

    authors: Quan KM,Shiran M,Watmough DJ

    更新日期:1989-11-01 00:00:00