Real-time 4DMRI-based internal target volume definition for moving lung tumors.

Abstract:

PURPOSE:In photon radiotherapy, respiratory-induced target motion can be accounted for by internal target volumes (ITV) or mid-ventilation target volumes (midV) defined on the basis of four-dimensional computed tomography (4D-CT). Intrinsic limitations of these approaches can result in target volumes that are not representative for the gross tumor volume (GTV) motion over the course of treatment. To address these limitations, we propose a novel patient-specific ITV definition method based on real-time 4D magnetic resonance imaging (rt-4DMRI). METHODS:Three lung cancer patients underwent weekly rt-4DMRI scans. A total of 24 datasets were included in this retrospective study. The GTV was contoured on breath-hold MR images and propagated to all rt-4DMRI images by deformable image registration. Different targets were created for the first (reference) imaging sessions: ITVs encompassing all GTV positions over the complete (ITV 80 s ) or partial acquisition time ( ITV 10 s ), ITVs including only voxels with a GTV probability-of-presence (POP) of at least 5% ( ITV 5 % ) or 10% ( ITV 10 % ), and the mid-ventilation GTV position. Reference planning target volumes ( PTV r ) were created by adding margins around the ITVs and midV target volumes. The geometrical overlap of the PTV r with ITV n 5 % from the six to eight subsequent imaging sessions on days n was quantified in terms of the Dice similarity coefficient (DSC), sensitivity [SE: ( PTV r ∩ ITV n 5 % )/ ITV n 5 % ] and precision [PRE: ( PTV r ∩ ITV n 5 % )/ PTV r ] as surrogates for target coverage and normal tissue sparing. RESULTS:Patient-specific analysis yielded a high variance of the overlap values of PTV r 10 s , when different periods within the reference imaging session were sampled. The mid-ventilation-based PTVs were smaller than the ITV-based PTVs. While the SE was high for patients with small breathing pattern variations, changes of the median breathing amplitudes in different imaging sessions led to inferior SE values for the mid-ventilation PTV for one patient. In contrast, PTV r 5 % and PTV r 10 % showed higher SE values with a higher robustness against interfractional changes, at the cost of larger target volumes. CONCLUSIONS:The results indicate that rt-4DMRI could be valuable for the definition of target volumes based on the GTV POP to achieve a higher robustness against interfractional changes than feasible with today's 4D-CT-based target definition concepts.

journal_name

Med Phys

journal_title

Medical physics

authors

Rabe M,Thieke C,Düsberg M,Neppl S,Gerum S,Reiner M,Nicolay NH,Schlemmer HP,Debus J,Dinkel J,Landry G,Parodi K,Belka C,Kurz C,Kamp F

doi

10.1002/mp.14023

subject

Has Abstract

pub_date

2020-04-01 00:00:00

pages

1431-1442

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • Assessment of the limiting spatial resolution of an MRI scanner by direct analysis of the edge spread function.

    abstract::Limiting spatial resolution is a key metric of the quality of magnetic resonance (MR) images, which can provide an indication of the smallest region that can effectively be imaged. In this paper a novel methodology for measuring the limiting spatial resolution of MR images is mathematically analyzed and successfully i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3097633

    authors: Delakis I,Xanthis C,Kitney RI

    更新日期:2009-05-01 00:00:00

  • Dose planning with comparison to in vivo dosimetry for epithermal neutron irradiation of the dog brain.

    abstract::Boron neutron capture therapy (BNCT) is an experimental type of radiotherapy, presently being used to treat glioblastoma and melanoma. To improve patient safety and to determine the radiobiological characteristics of the epithermal neutron beam of Finnish BNCT facility (FiR 1) dose-response studies were carried on the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1517048

    authors: Seppälä T,Auterinen I,Aschan C,Serén T,Benczik J,Snellman M,Huiskamp R,Ramadan UA,Kankaanranta L,Joensuu H,Savolainen S

    更新日期:2002-11-01 00:00:00

  • Development and clinical implementation of semi-automated treatment planning including 3D printable applicator holders in complex skin brachytherapy.

    abstract:PURPOSE:High-dose-rate brachytherapy (HDR-BT) is a treatment option for malignant skin diseases compared to external beam radiation therapy, HDR-BT provides improved target coverage, better organ sparing, and has comparable treatment times. This is especially true for large clinical targets with complex topologies. To ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13975

    authors: Guthier CV,Devlin PM,Harris TC,O'Farrell DA,Cormack RA,Buzurovic I

    更新日期:2020-03-01 00:00:00

  • Multiattribute probabilistic prostate elastic registration (MAPPER): application to fusion of ultrasound and magnetic resonance imaging.

    abstract:PURPOSE:Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is bett...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905104

    authors: Sparks R,Bloch BN,Feleppa E,Barratt D,Moses D,Ponsky L,Madabhushi A

    更新日期:2015-03-01 00:00:00

  • SU-E-T-459: Radiobiological Evaluation of Implant Duration and Radionuclide Selection for COMS Eye Plaque Brachytherapy Using an Objective Function.

    abstract:PURPOSE:The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide (R) and implant duration (T). This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position (P), prescription dose, R, an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735548

    authors: Gagne N,Rivard M

    更新日期:2012-06-01 00:00:00

  • A multiple detector array helical x-ray microtomography system for specimen imaging.

    abstract::An x-ray computed microtomography system for specimen and small animal imaging was built and tested. The system used seventeen 48-microm-wide detector arrays (a charge coupled device camera) and helical acquisition techniques. Images were acquired using 540 rays/view and 400 views/2pi. The modulation transfer function...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598662

    authors: Corrigan NM,Chavez AE,Wisner ER,Boone JM

    更新日期:1999-08-01 00:00:00

  • Intensity-modulation radiotherapy using independent collimators: an algorithm study.

    abstract::The purpose of this work is to investigate algorithms for the delivery of intensity-modulated fields using independent collimators (IC). Two heuristic algorithms are proposed to calculate jaw-setting sequences for arbitrary 2D intensity distributions. The first algorithm is based on searching the whole intensity matri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598794

    authors: Dai JR,Hu YM

    更新日期:1999-12-01 00:00:00

  • The line spread function and modulation transfer function of a computed tomographic scanner.

    abstract::A simple method to measure the line spread function of computed tomographic scanners has been developed. The line spread function of the EMI-Scanner was measured and the MTF of the scanner was calculated. The reproducibility of the method indicated this technique could be utilized to compare the spatial resolution of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594283

    authors: Judy PF

    更新日期:1976-07-01 00:00:00

  • On-board SPECT for localizing functional targets: a simulation study.

    abstract::Single photon emission computed tomography (SPECT) was investigated for imaging on-board radiation therapy machines in order to localize functional and molecular targets. A computer-simulated female NCAT phantom was positioned supine on a flat-top treatment couch. Twenty tumor locations were defined in the upper torso...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3113902

    authors: Roper J,Bowsher J,Yin FF

    更新日期:2009-05-01 00:00:00

  • TU-E-217BCD-10: Dose Reduction in Digital Breast Tomosynthesis with the Dose Reduction Prior Image Constrained Compressed Sensing (DR-PICCS) Algorithm.

    abstract:PURPOSE:To reduce image noise and radiation dose in Digital Breast Tomosynthesis (DBT) reconstructions. METHODS:A retrospective study was performed on clinical data sets acquired at a normal dose with Hologic Selenia Dimensions DBT systems. The Prior Image Constrained Compressed Sensing (PICCS) algorithm was used to r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735982

    authors: Garrett J,Tang J,Zhang Y,Ruth C,Jing Z,Chen GH

    更新日期:2012-06-01 00:00:00

  • MO-D-213CD-04: 4D X-Ray DSA and 4D Fluoroscopy.

    abstract::During the past decade the use of undersampled acquisition and constrained reconstruction have led to significant increases in data acquisition speed, SNR, spatial resolution and temporal resolution in MR imaging. When a separately acquired constraining image is combined with an angiographic time series the traditiona...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735797

    authors: Mistretta C

    更新日期:2012-06-01 00:00:00

  • A data-mining framework for large scale analysis of dose-outcome relationships in a database of irradiated head and neck cancer patients.

    abstract:PURPOSE:To develop a hypothesis-generating framework for automatic extraction of dose-outcome relationships from an in-house, analytic oncology database. METHODS:Dose-volume histograms (DVH) and clinical outcomes have been routinely stored to the authors' database for 684 head and neck cancer patients treated from 200...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4922686

    authors: Robertson SP,Quon H,Kiess AP,Moore JA,Yang W,Cheng Z,Afonso S,Allen M,Richardson M,Choflet A,Sharabi A,McNutt TR

    更新日期:2015-07-01 00:00:00

  • A regional convolution kernel algorithm for scatter correction in dual-energy images: comparison to single-kernel algorithms.

    abstract::Single kernel scatter correction algorithms are based on the model that the scatter field can be predicted by convolution of the primary intensity (Iprim) with a spatially invariant scatter point-spread function (PSF). Practical limitations (Iprim unknown) suggest the substitution of the total detected intensity (Idet...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597297

    authors: Kruger DG,Zink F,Peppler WW,Ergun DL,Mistretta CA

    更新日期:1994-02-01 00:00:00

  • Technical Note: Correction for intra-chamber dose gradients in reference dosimetry of flattening-filter-free MV photon beams.

    abstract:PURPOSE:To estimate and correct for the volume averaging effect which results from the intra-chamber dose gradients when a Farmer ionization chamber (IC) is used for reference dosimetry in flattening-filter-free (FFF) MV photon beams. METHODS:An intra-chamber dose gradients correction factor (kicdg) to the charge read...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4958960

    authors: Ruggieri R,Naccarato S,Stavrev P,Stavreva N,Pasetto S,Salamone I,Alongi F

    更新日期:2016-08-01 00:00:00

  • SU-E-J-63: Feasibility Study of Proton Digital Tomosynthesis in Proton Beam Therapy.

    abstract:PURPOSE:We investigated the feasibility of proton tomosynthesis as daily positioning of patients and compared the results with photon tomosynthesis as an alternative to conventional portal imaging or on-board cone-beam computed tomography. METHODS:Dedicated photon-like proton beam using the passively scattered proton ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734898

    authors: Min B,Kwak J,Lee J,Cho S,Park S,Yoo S,Chung K,Cho S,Lim Y,Shin D,Lee S,Kim J

    更新日期:2012-06-01 00:00:00

  • Traceable micro-CT scaling accuracy phantom for applications requiring exact measurement of distances or volumes.

    abstract:PURPOSE:Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4752083

    authors: Waring CS,Bax JS,Samarabandu A,Holdsworth DW,Fenster A,Lacefield JC

    更新日期:2012-10-01 00:00:00

  • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.

    abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3117563

    authors: Létourneau D,Publicover J,Kozelka J,Moseley DJ,Jaffray DA

    更新日期:2009-05-01 00:00:00

  • High resolution digital autoradiographic and dosimetric analysis of heterogeneous radioactivity distribution in xenografted prostate tumors.

    abstract:PURPOSE:The first main aim of this study was to illustrate the absorbed dose rate distribution from 177Lu in sections of xenografted prostate cancer (PCa) tumors using high resolution digital autoradiography (DAR) and compare it with hypothetical identical radioactivity distributions of 90Y or 7 MeV alpha-particles. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4967877

    authors: Timmermand OV,Nilsson J,Strand SE,Elgqvist J

    更新日期:2016-12-01 00:00:00

  • Invertibility of the dual energy x-ray data transform.

    abstract:PURPOSE:The Alvarez-Macovski method extracts the x-ray energy-dependent information by expanding the attenuation coefficient as a linear combination of functions of energy multiplied by basis set coefficients. Since the basis functions are known a priori, the coefficients represent all the energy-dependent information....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13255

    authors: Alvarez RE

    更新日期:2019-01-01 00:00:00

  • Anthropomorphic 1H MRS head phantom.

    abstract::An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598306

    authors: Rice JR,Milbrandt RH,Madsen EL,Frank GR,Boote EJ,Blechinger JC

    更新日期:1998-07-01 00:00:00

  • Calculation of lung mean dose and quantification of error for 90 Y-microsphere radioembolization using 99m Tc-MAA SPECT/CT and diagnostic chest CT.

    abstract:PURPOSE:Current treatment planning for 90 Y radioembolization estimates lung mean dose (LMD) by measuring the lung shunt fraction (LSF) from 99m Tc-macroaggregated albumin (MAA) planar imaging and assuming a 1-kg lung mass. This methodology, however, overestimates LSF and LMD and could therefore unnecessarily limit the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13575

    authors: Lopez B,Mahvash A,Lam MGEH,Kappadath SC

    更新日期:2019-09-01 00:00:00

  • Experimental investigation on the accuracy of plastic scintillators and of the spectrum discrimination method in small photon fields.

    abstract:PURPOSE:To investigate the accuracy of output factor measurements using a commercial (Exradin W1, SI) and a prototype, "in-house" developed, plastic scintillation dosimeter (PSD) in small photon fields. METHODS:Repetitive detector-specific output factor OFdet measurements were performed in water (parallel to the CAX) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12064

    authors: Papaconstadopoulos P,Archambault L,Seuntjens J

    更新日期:2017-02-01 00:00:00

  • Efficient generation of a magnetic field-free line.

    abstract:PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was i...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3447726

    authors: Knopp T,Erbe M,Biederer S,Sattel TF,Buzug TM

    更新日期:2010-07-01 00:00:00

  • Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production.

    abstract:PURPOSE:The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. METHODS:The effective range, deflectio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3539623

    authors: Leung MK,Chow JC,Chithrani BD,Lee MJ,Oms B,Jaffray DA

    更新日期:2011-02-01 00:00:00

  • First clinical implementation of real-time, real anatomy tracking and radiation beam control.

    abstract:PURPOSE:We describe the acceptance testing, commissioning, periodic quality assurance, and workflow procedures developed for the first clinically implemented magnetic resonance imaging-guided radiation therapy (MR-IGRT) system for real-time tracking and beam control. METHODS:The system utilizes real-time cine imaging ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13002

    authors: Green OL,Rankine LJ,Cai B,Curcuru A,Kashani R,Rodriguez V,Li HH,Parikh PJ,Robinson CG,Olsen JR,Mutic S,Goddu SM,Santanam L

    更新日期:2018-05-28 00:00:00

  • Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.

    abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945414

    authors: Togno M,Wilkens JJ,Menichelli D,Oechsner M,Perez-Andujar A,Morin O

    更新日期:2016-05-01 00:00:00

  • Calibrated breast density methods for full field digital mammography: a system for serial quality control and inter-system generalization.

    abstract:PURPOSE:The authors are developing a system for calibrated breast density measurements using full field digital mammography (FFDM). Breast tissue equivalent (BTE) phantom images are used to establish baseline (BL) calibration curves at time zero. For a given FFDM unit, the full BL dataset is comprised of approximately ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903299

    authors: Lu B,Smallwood AM,Sellers TA,Drukteinis JS,Heine JJ,Fowler EE

    更新日期:2015-02-01 00:00:00

  • A systematic Monte Carlo study of secondary electron fluence perturbation in clinical proton beams (70-250 MeV) for cylindrical and spherical ion chambers.

    abstract::Current dosimetry protocols for clinical protons do not take into account any secondary electron fluence perturbation in ion chambers. In this work, we performed a systematic study of secondary electron fluence perturbation factors for spherical and cylindrical ion chambers in proton beams (70-250 MeV). The electron f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1406519

    authors: Verhaegen F,Palmans H

    更新日期:2001-10-01 00:00:00

  • Characterizing the reflectivity of handheld display devices.

    abstract:PURPOSE:With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4887813

    authors: Liu P,Badano A

    更新日期:2014-08-01 00:00:00

  • High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array.

    abstract:PURPOSE:The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3694667

    authors: Qian X,Tucker A,Gidcumb E,Shan J,Yang G,Calderon-Colon X,Sultana S,Lu J,Zhou O,Spronk D,Sprenger F,Zhang Y,Kennedy D,Farbizio T,Jing Z

    更新日期:2012-04-01 00:00:00