Abstract:
PURPOSE:In photon radiotherapy, respiratory-induced target motion can be accounted for by internal target volumes (ITV) or mid-ventilation target volumes (midV) defined on the basis of four-dimensional computed tomography (4D-CT). Intrinsic limitations of these approaches can result in target volumes that are not representative for the gross tumor volume (GTV) motion over the course of treatment. To address these limitations, we propose a novel patient-specific ITV definition method based on real-time 4D magnetic resonance imaging (rt-4DMRI). METHODS:Three lung cancer patients underwent weekly rt-4DMRI scans. A total of 24 datasets were included in this retrospective study. The GTV was contoured on breath-hold MR images and propagated to all rt-4DMRI images by deformable image registration. Different targets were created for the first (reference) imaging sessions: ITVs encompassing all GTV positions over the complete (ITV 80 s ) or partial acquisition time ( ITV 10 s ), ITVs including only voxels with a GTV probability-of-presence (POP) of at least 5% ( ITV 5 % ) or 10% ( ITV 10 % ), and the mid-ventilation GTV position. Reference planning target volumes ( PTV r ) were created by adding margins around the ITVs and midV target volumes. The geometrical overlap of the PTV r with ITV n 5 % from the six to eight subsequent imaging sessions on days n was quantified in terms of the Dice similarity coefficient (DSC), sensitivity [SE: ( PTV r ∩ ITV n 5 % )/ ITV n 5 % ] and precision [PRE: ( PTV r ∩ ITV n 5 % )/ PTV r ] as surrogates for target coverage and normal tissue sparing. RESULTS:Patient-specific analysis yielded a high variance of the overlap values of PTV r 10 s , when different periods within the reference imaging session were sampled. The mid-ventilation-based PTVs were smaller than the ITV-based PTVs. While the SE was high for patients with small breathing pattern variations, changes of the median breathing amplitudes in different imaging sessions led to inferior SE values for the mid-ventilation PTV for one patient. In contrast, PTV r 5 % and PTV r 10 % showed higher SE values with a higher robustness against interfractional changes, at the cost of larger target volumes. CONCLUSIONS:The results indicate that rt-4DMRI could be valuable for the definition of target volumes based on the GTV POP to achieve a higher robustness against interfractional changes than feasible with today's 4D-CT-based target definition concepts.
journal_name
Med Physjournal_title
Medical physicsauthors
Rabe M,Thieke C,Düsberg M,Neppl S,Gerum S,Reiner M,Nicolay NH,Schlemmer HP,Debus J,Dinkel J,Landry G,Parodi K,Belka C,Kurz C,Kamp Fdoi
10.1002/mp.14023subject
Has Abstractpub_date
2020-04-01 00:00:00pages
1431-1442issue
4eissn
0094-2405issn
2473-4209journal_volume
47pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Limiting spatial resolution is a key metric of the quality of magnetic resonance (MR) images, which can provide an indication of the smallest region that can effectively be imaged. In this paper a novel methodology for measuring the limiting spatial resolution of MR images is mathematically analyzed and successfully i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3097633
更新日期:2009-05-01 00:00:00
abstract::Boron neutron capture therapy (BNCT) is an experimental type of radiotherapy, presently being used to treat glioblastoma and melanoma. To improve patient safety and to determine the radiobiological characteristics of the epithermal neutron beam of Finnish BNCT facility (FiR 1) dose-response studies were carried on the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1517048
更新日期:2002-11-01 00:00:00
abstract:PURPOSE:High-dose-rate brachytherapy (HDR-BT) is a treatment option for malignant skin diseases compared to external beam radiation therapy, HDR-BT provides improved target coverage, better organ sparing, and has comparable treatment times. This is especially true for large clinical targets with complex topologies. To ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13975
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is bett...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4905104
更新日期:2015-03-01 00:00:00
abstract:PURPOSE:The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide (R) and implant duration (T). This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position (P), prescription dose, R, an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735548
更新日期:2012-06-01 00:00:00
abstract::An x-ray computed microtomography system for specimen and small animal imaging was built and tested. The system used seventeen 48-microm-wide detector arrays (a charge coupled device camera) and helical acquisition techniques. Images were acquired using 540 rays/view and 400 views/2pi. The modulation transfer function...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598662
更新日期:1999-08-01 00:00:00
abstract::The purpose of this work is to investigate algorithms for the delivery of intensity-modulated fields using independent collimators (IC). Two heuristic algorithms are proposed to calculate jaw-setting sequences for arbitrary 2D intensity distributions. The first algorithm is based on searching the whole intensity matri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598794
更新日期:1999-12-01 00:00:00
abstract::A simple method to measure the line spread function of computed tomographic scanners has been developed. The line spread function of the EMI-Scanner was measured and the MTF of the scanner was calculated. The reproducibility of the method indicated this technique could be utilized to compare the spatial resolution of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594283
更新日期:1976-07-01 00:00:00
abstract::Single photon emission computed tomography (SPECT) was investigated for imaging on-board radiation therapy machines in order to localize functional and molecular targets. A computer-simulated female NCAT phantom was positioned supine on a flat-top treatment couch. Twenty tumor locations were defined in the upper torso...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3113902
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:To reduce image noise and radiation dose in Digital Breast Tomosynthesis (DBT) reconstructions. METHODS:A retrospective study was performed on clinical data sets acquired at a normal dose with Hologic Selenia Dimensions DBT systems. The Prior Image Constrained Compressed Sensing (PICCS) algorithm was used to r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735982
更新日期:2012-06-01 00:00:00
abstract::During the past decade the use of undersampled acquisition and constrained reconstruction have led to significant increases in data acquisition speed, SNR, spatial resolution and temporal resolution in MR imaging. When a separately acquired constraining image is combined with an angiographic time series the traditiona...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735797
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To develop a hypothesis-generating framework for automatic extraction of dose-outcome relationships from an in-house, analytic oncology database. METHODS:Dose-volume histograms (DVH) and clinical outcomes have been routinely stored to the authors' database for 684 head and neck cancer patients treated from 200...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4922686
更新日期:2015-07-01 00:00:00
abstract::Single kernel scatter correction algorithms are based on the model that the scatter field can be predicted by convolution of the primary intensity (Iprim) with a spatially invariant scatter point-spread function (PSF). Practical limitations (Iprim unknown) suggest the substitution of the total detected intensity (Idet...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597297
更新日期:1994-02-01 00:00:00
abstract:PURPOSE:To estimate and correct for the volume averaging effect which results from the intra-chamber dose gradients when a Farmer ionization chamber (IC) is used for reference dosimetry in flattening-filter-free (FFF) MV photon beams. METHODS:An intra-chamber dose gradients correction factor (kicdg) to the charge read...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4958960
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:We investigated the feasibility of proton tomosynthesis as daily positioning of patients and compared the results with photon tomosynthesis as an alternative to conventional portal imaging or on-board cone-beam computed tomography. METHODS:Dedicated photon-like proton beam using the passively scattered proton ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734898
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have be...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4752083
更新日期:2012-10-01 00:00:00
abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3117563
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:The first main aim of this study was to illustrate the absorbed dose rate distribution from 177Lu in sections of xenografted prostate cancer (PCa) tumors using high resolution digital autoradiography (DAR) and compare it with hypothetical identical radioactivity distributions of 90Y or 7 MeV alpha-particles. Th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4967877
更新日期:2016-12-01 00:00:00
abstract:PURPOSE:The Alvarez-Macovski method extracts the x-ray energy-dependent information by expanding the attenuation coefficient as a linear combination of functions of energy multiplied by basis set coefficients. Since the basis functions are known a priori, the coefficients represent all the energy-dependent information....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13255
更新日期:2019-01-01 00:00:00
abstract::An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598306
更新日期:1998-07-01 00:00:00
abstract:PURPOSE:Current treatment planning for 90 Y radioembolization estimates lung mean dose (LMD) by measuring the lung shunt fraction (LSF) from 99m Tc-macroaggregated albumin (MAA) planar imaging and assuming a 1-kg lung mass. This methodology, however, overestimates LSF and LMD and could therefore unnecessarily limit the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13575
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:To investigate the accuracy of output factor measurements using a commercial (Exradin W1, SI) and a prototype, "in-house" developed, plastic scintillation dosimeter (PSD) in small photon fields. METHODS:Repetitive detector-specific output factor OFdet measurements were performed in water (parallel to the CAX) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12064
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was i...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.3447726
更新日期:2010-07-01 00:00:00
abstract:PURPOSE:The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. METHODS:The effective range, deflectio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3539623
更新日期:2011-02-01 00:00:00
abstract:PURPOSE:We describe the acceptance testing, commissioning, periodic quality assurance, and workflow procedures developed for the first clinically implemented magnetic resonance imaging-guided radiation therapy (MR-IGRT) system for real-time tracking and beam control. METHODS:The system utilizes real-time cine imaging ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13002
更新日期:2018-05-28 00:00:00
abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4945414
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:The authors are developing a system for calibrated breast density measurements using full field digital mammography (FFDM). Breast tissue equivalent (BTE) phantom images are used to establish baseline (BL) calibration curves at time zero. For a given FFDM unit, the full BL dataset is comprised of approximately ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4903299
更新日期:2015-02-01 00:00:00
abstract::Current dosimetry protocols for clinical protons do not take into account any secondary electron fluence perturbation in ion chambers. In this work, we performed a systematic study of secondary electron fluence perturbation factors for spherical and cylindrical ion chambers in proton beams (70-250 MeV). The electron f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1406519
更新日期:2001-10-01 00:00:00
abstract:PURPOSE:With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4887813
更新日期:2014-08-01 00:00:00
abstract:PURPOSE:The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3694667
更新日期:2012-04-01 00:00:00