Decoding overt shifts of attention in depth through pupillary and cortical frequency tagging.

Abstract:

OBJECTIVE:We have recently developed a prototype of a novel human-computer interface for assistive communication based on voluntary shifts of attention (gaze) from a far target to a near target associated with a decrease of pupil size (Pupillary Accommodative Response, PAR), an automatic vegetative response that can be easily recorded. We report here an extension of that approach based on pupillary and cortical frequency tagging. APPROACH:In 18 healthy volunteers, we investigated the possibility of decoding attention shifts in depth by exploiting the evoked oscillatory responses of the pupil (Pupillary Oscillatory Response, POR, recorded through a low-cost device) and visual cortex (Steady-State Visual Evoked Potentials, SSVEP, recorded from 4 scalp electrodes). With a simple binary communication protocol (focusing on a far target meaning "No", focusing on the near target meaning "Yes"), we aimed at discriminating when observer's overt attention (gaze) shifted from the far to the near target, which were flickering at different frequencies. MAIN RESULTS:By applying a binary linear classifier (Support Vector Machine, SVM, with leave-one-out cross validation) to POR and SSVEP signals, we found that, with only twenty trials and no subjects' behavioural training, the offline median decoding accuracy was 75% and 80% with POR and SSVEP signals, respectively. When the two signals were combined together, accuracy reached 83%. The number of observers for whom accuracy was higher than 70% was 11/18, 12/18 and 14/18 with POR, SVVEP and combined features, respectively. A signal detection analysis confirmed these results. SIGNIFICANCE:The present findings suggest that exploiting frequency tagging with pupillary or cortical responses during an attention shift in the depth plane, either separately or combined together, is a promising approach to realize a device for communicating with Complete Locked-In Syndrome (CLIS) patients when oculomotor control is unreliable and traditional assistive communication, even based on PAR, is unsuccessful.

journal_name

J Neural Eng

authors

de'Sperati C,Roatta S,Zovetti N,Baroni T

doi

10.1088/1741-2552/ab8e8f

subject

Has Abstract

pub_date

2020-04-29 00:00:00

eissn

1741-2560

issn

1741-2552

pub_type

杂志文章
  • Scanning electron microscopy of chronically implanted intracortical microelectrode arrays in non-human primates.

    abstract:OBJECTIVE:Signal attenuation is a major problem facing intracortical sensors for chronic neuroprosthetic applications. Many studies suggest that failure is due to gliosis around the electrode tips, however, mechanical and material causes of failure are often overlooked. The purpose of this study was to investigate the ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/2/026003

    authors: Barrese JC,Aceros J,Donoghue JP

    更新日期:2016-04-01 00:00:00

  • DataHigh: graphical user interface for visualizing and interacting with high-dimensional neural activity.

    abstract:OBJECTIVE:Analyzing and interpreting the activity of a heterogeneous population of neurons can be challenging, especially as the number of neurons, experimental trials, and experimental conditions increases. One approach is to extract a set of latent variables that succinctly captures the prominent co-fluctuation patte...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/6/066012

    authors: Cowley BR,Kaufman MT,Butler ZS,Churchland MM,Ryu SI,Shenoy KV,Yu BM

    更新日期:2013-12-01 00:00:00

  • Spatial channel interactions in cochlear implants.

    abstract::The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies g...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/4/046029

    authors: Tang Q,Benítez R,Zeng FG

    更新日期:2011-08-01 00:00:00

  • Computationally inexpensive enhanced growing neural gas algorithm for real-time adaptive neural spike clustering.

    abstract:OBJECTIVE:Real-time closed-loop neural feedback control requires the analysis of action potential traces within several milliseconds after they have been recorded from the brain. The current generation of spike clustering algorithms were mostly designed for off-line use and also require a significant amount of computat...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab208c

    authors: Mohammadi Z,Kincaid JM,Pun SH,Klug A,Liu C,Lei TC

    更新日期:2019-07-30 00:00:00

  • Speech stream segregation to control an ERP-based auditory BCI.

    abstract:OBJECTIVE:The use of natural sounds in auditory Brain-Computer Interfaces (BCI) has been shown to improve classification results and usability. Some auditory BCIs are based on stream segregation, in which the subjects must attend one audio stream and ignore the other(s); these streams include some kind of stimuli to be...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abdd44

    authors: Velasco-Álvarez F,Fernández-Rodríguez Á,Medina-Juliá MT,Ron-Angevin R

    更新日期:2021-01-19 00:00:00

  • Brain-actuated gait trainer with visual and proprioceptive feedback.

    abstract:OBJECTIVE:Brain-machine interfaces (BMIs) have been proposed in closed-loop applications for neuromodulation and neurorehabilitation. This study describes the impact of different feedback modalities on the performance of an EEG-based BMI that decodes motor imagery (MI) of leg flexion and extension. APPROACH:We execute...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa7df9

    authors: Liu D,Chen W,Lee K,Chavarriaga R,Bouri M,Pei Z,Del R Millán J

    更新日期:2017-10-01 00:00:00

  • Inclusion of temporal priors for automated neonatal EEG classification.

    abstract::The aim of this paper is to use recent advances in the clinical understanding of the temporal evolution of seizure burden in neonates with hypoxic ischemic encephalopathy to improve the performance of automated detection algorithms. Probabilistic weights are designed from temporal locations of neonatal seizure events ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/4/046002

    authors: Temko A,Stevenson N,Marnane W,Boylan G,Lightbody G

    更新日期:2012-08-01 00:00:00

  • Evaluation of windowing techniques for intramuscular EMG-based diagnostic, rehabilitative and assistive devices.

    abstract:OBJECTIVE:Intramuscular electromyography (iEMG) signals, non-invasively recorded, directly from the muscles are used to diagnose various neuromuscular disorders/diseases, also to control rehabilitative and assistive robotic devices. iEMG signals are being potentially used in neurology, kinesiology, rehabilitation, and ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abcc7f

    authors: Ashraf H,Waris A,Gilani SO,Kashif AS,Jamil M,Jochumsen M,Niazi IK

    更新日期:2020-11-20 00:00:00

  • Assessment of gliosis around moveable implants in the brain.

    abstract::Repositioning microelectrodes post-implantation is emerging as a promising approach to achieve long-term reliability in single neuronal recordings. The main goal of this study was to (a) assess glial reaction in response to movement of microelectrodes in the brain post-implantation and (b) determine an optimal window ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/6/4/046004

    authors: Stice P,Muthuswamy J

    更新日期:2009-08-01 00:00:00

  • A MEMS-based flexible multichannel ECoG-electrode array.

    abstract::We present a micromachined 252-channel ECoG (electrocorticogram)-electrode array, which is made of a thin polyimide foil substrate enclosing sputtered platinum electrode sites and conductor paths. The array subtends an area of approximately 35 mm by 60 mm and is designed to cover large parts of a hemisphere of a macaq...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/6/3/036003

    authors: Rubehn B,Bosman C,Oostenveld R,Fries P,Stieglitz T

    更新日期:2009-06-01 00:00:00

  • Ensembles of adaptive spatial filters increase BCI performance: an online evaluation.

    abstract:OBJECTIVE:In electroencephalographic (EEG) data, signals from distinct sources within the brain are widely spread by volume conduction and superimposed such that sensors receive mixtures of a multitude of signals. This reduction of spatial information strongly hampers single-trial analysis of EEG data as, for example, ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/4/046003

    authors: Sannelli C,Vidaurre C,Müller KR,Blankertz B

    更新日期:2016-08-01 00:00:00

  • Within-socket myoelectric prediction of continuous ankle kinematics for control of a powered transtibial prosthesis.

    abstract:OBJECTIVE:Powered robotic prostheses create a need for natural-feeling user interfaces and robust control schemes. Here, we examined the ability of a nonlinear autoregressive model to continuously map the kinematics of a transtibial prosthesis and electromyographic (EMG) activity recorded within socket to the future es...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/5/056027

    authors: Farmer S,Silver-Thorn S,Voglewede P,Beardsley SA

    更新日期:2014-10-01 00:00:00

  • Impact of referencing scheme on decoding performance of LFP-based brain-machine interface.

    abstract:OBJECTIVE:There has recently been an increasing interest in local field potential (LFP) for brain-machine interface (BMI) applications due to its desirable properties (signal stability and low bandwidth). LFP is typically recorded with respect to a single unipolar reference which is susceptible to common noise. Several...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abce3c

    authors: Ahmadi N,Constandinou T,Bouganis CS

    更新日期:2020-11-26 00:00:00

  • Autoencoders for learning template spectrograms in electrocorticographic signals.

    abstract:OBJECTIVE:Electrocorticography (ECoG) based studies generally analyze features from specific frequency bands selected by manual evaluation of spectral power. However, the definition of these features can vary across subjects, cortical areas, tasks and across time for a given subject. We propose an autoencoder based app...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaf13f

    authors: Pailla T,Miller KJ,Gilja V

    更新日期:2019-02-01 00:00:00

  • Bispectrum-based feature extraction technique for devising a practical brain-computer interface.

    abstract::The extraction of distinctly separable features from electroencephalogram (EEG) is one of the main challenges in designing a brain-computer interface (BCI). Existing feature extraction techniques for a BCI are mostly developed based on traditional signal processing techniques assuming that the signal is Gaussian and h...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/2/025014

    authors: Shahid S,Prasad G

    更新日期:2011-04-01 00:00:00

  • Tissue-engineered nerve grafts using a scaffold-independent and injectable drug delivery system: a novel design with translational advantages.

    abstract:OBJECTIVE:Currently commercially available nerve conduits have demonstrated suboptimal clinical efficacy in repairing peripheral nerve defects. Although tissue-engineered nerve grafts (TENGs) with sustained release of neurotrophic factors (NTFs) are experimentally proved to be more effective than these blank conduits, ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab17a0

    authors: Liu Y,Yu S,Gu X,Cao R,Cui S

    更新日期:2019-06-01 00:00:00

  • Assessment of brain-machine interfaces from the perspective of people with paralysis.

    abstract:OBJECTIVE:One of the main goals of brain-machine interface (BMI) research is to restore function to people with paralysis. Currently, multiple BMI design features are being investigated, based on various input modalities (externally applied and surgically implantable sensors) and output modalities (e.g. control of comp...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/4/043002

    authors: Blabe CH,Gilja V,Chestek CA,Shenoy KV,Anderson KD,Henderson JM

    更新日期:2015-08-01 00:00:00

  • Corrigendum: Tissue-engineered nerve grafts using a scaffold-independent and injectable drug delivery system: a novel design with translational advantages (2019 J. Neural Eng. 16 036030).

    abstract:OBJECTIVE:Currently commercially available nerve conduits have demonstrated suboptimal clinical efficacy in repairing peripheral nerve defects. Although tissue-engineered nerve grafts (TENGs) with sustained release of neurotrophic factors (NTFs) are experimentally proved to be more effective than these blank conduits, ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd1ec

    authors: Liu Y,Yu S,Gu X,Cao R,Cui S

    更新日期:2020-12-09 00:00:00

  • Single input optimal control for globally coupled neuron networks.

    abstract::We consider the problem of desynchronizing a network of synchronized, globally (all-to-all) coupled neurons using an input to a single neuron. This is done by applying the discrete time dynamic programming method to reduced phase models for neural populations. This technique numerically minimizes a certain cost functi...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/6/065008

    authors: Nabi A,Moehlis J

    更新日期:2011-12-01 00:00:00

  • Millimeter-scale epileptiform spike propagation patterns and their relationship to seizures.

    abstract:OBJECTIVE:Current mapping of epileptic networks in patients prior to epilepsy surgery utilizes electrode arrays with sparse spatial sampling (∼1.0 cm inter-electrode spacing). Recent research demonstrates that sub-millimeter, cortical-column-scale domains have a role in seizure generation that may be clinically signifi...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/2/026015

    authors: Vanleer AC,Blanco JA,Wagenaar JB,Viventi J,Contreras D,Litt B

    更新日期:2016-04-01 00:00:00

  • Brain-computer interfacing under distraction: an evaluation study.

    abstract:OBJECTIVE:While motor-imagery based brain-computer interfaces (BCIs) have been studied over many years by now, most of these studies have taken place in controlled lab settings. Bringing BCI technology into everyday life is still one of the main challenges in this field of research. APPROACH:This paper systematically ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/5/056012

    authors: Brandl S,Frølich L,Höhne J,Müller KR,Samek W

    更新日期:2016-10-01 00:00:00

  • Optimizing the design of bipolar nerve cuff electrodes for improved recording of peripheral nerve activity.

    abstract:OBJECTIVE:Differential measurement of efferent and afferent peripheral nerve activity offers a promising means of improving the clinical utility of implantable neuroprostheses. The tripolar nerve cuff electrode has historically served as the gold standard for achieving high signal-to-noise ratios (SNRs) of the recordin...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa6407

    authors: Sabetian P,Popovic MR,Yoo PB

    更新日期:2017-06-01 00:00:00

  • Spatial and temporal variability in response to hybrid electro-optical stimulation.

    abstract::Hybrid electro-optical neural stimulation is a novel paradigm combining the advantages of optical and electrical stimulation techniques while reducing their respective limitations. However, in order to fulfill its promise, this technique requires reduced variability and improved reproducibility. Here we used a compara...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/3/036003

    authors: Duke AR,Lu H,Jenkins MW,Chiel HJ,Jansen ED

    更新日期:2012-06-01 00:00:00

  • VITA-an everyday virtual reality setup for prosthetics and upper-limb rehabilitation.

    abstract:OBJECTIVE:Currently, there are some 95 000 people in Europe suffering from upper-limb impairment. Rehabilitation should be undertaken right after the impairment occurs and should be regularly performed thereafter. Moreover, the rehabilitation process should be tailored specifically to both patient and impairment. APPR...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaf35f

    authors: Nissler C,Nowak M,Connan M,Büttner S,Vogel J,Kossyk I,Márton ZC,Castellini C

    更新日期:2019-04-01 00:00:00

  • Hardware architecture for real-time EEG-based functional brain connectivity parameter extraction.

    abstract::In this work, we proposed a novel architecture for real-time quantitative characterization of functional brain connectivity networks derived from Electroencephalogram (EEG). It consists of two main parts - calculation of Phase Lag Index (PLI) to form the functional connectivity networks and the extraction of a set of ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd462

    authors: Gutierrez Nuno RA,Chung CHR,Maharatna K

    更新日期:2020-12-16 00:00:00

  • Motor cortex stimulation for Parkinson's disease: a modelling study.

    abstract::Chronic motor cortex stimulation (MCS) is currently being investigated as a treatment method for Parkinson's disease (PD). Unfortunately, the underlying mechanisms of this treatment are unclear and there are many uncertainties regarding the most effective stimulation parameters and electrode configuration. In this pap...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/5/056005

    authors: Zwartjes DG,Heida T,Feirabend HK,Janssen ML,Visser-Vandewalle V,Martens HC,Veltink PH

    更新日期:2012-10-01 00:00:00

  • Subspace-based interference removal methods for a multichannel biomagnetic sensor array.

    abstract:OBJECTIVE:In biomagnetic signal processing, the theory of the signal subspace has been applied to removing interfering magnetic fields, and a representative algorithm is the signal space projection algorithm, in which the signal/interference subspace is defined in the spatial domain as the span of signal/interference-s...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2552/aa7693

    authors: Sekihara K,Nagarajan SS

    更新日期:2017-10-01 00:00:00

  • Common time-frequency analysis of local field potential and pyramidal cell activity in seizure-like events of the rat hippocampus.

    abstract::To study cell-field dynamics, physiologists simultaneously record local field potentials and the activity of individual cells from animals performing cognitive tasks, during various brain states or under pathological conditions. However, apart from spike shape and spike timing analyses, few studies have focused on elu...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/4/046024

    authors: Cotic M,Chiu AW,Jahromi SS,Carlen PL,Bardakjian BL

    更新日期:2011-08-01 00:00:00

  • Long-term recording reliability of liquid crystal polymer µECoG arrays.

    abstract:OBJECTIVE:The clinical use of microsignals recorded over broad cortical regions is largely limited by the chronic reliability of the implanted interfaces. APPROACH:We evaluated the chronic reliability of novel 61-channel micro-electrocorticographic (µECoG) arrays in rats chronically implanted for over one year and usi...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aae39d

    authors: Woods V,Trumpis M,Bent B,Palopoli-Trojani K,Chiang CH,Wang C,Yu C,Insanally MN,Froemke RC,Viventi J

    更新日期:2018-12-01 00:00:00

  • Stem cells from human exfoliated deciduous teeth differentiate toward neural cells in a medium dynamically cultured with Schwann cells in a series of polydimethylsiloxanes scaffolds.

    abstract:OBJECTIVE:Schwann cells (SCs) are primary structural and functional cells in the peripheral nervous system. These cells play a crucial role in peripheral nerve regeneration by releasing neurotrophic factors. This study evaluated the neural differentiation potential effects of stem cells from human exfoliated deciduous ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/4/046005

    authors: Su WT,Pan YJ

    更新日期:2016-08-01 00:00:00