The long-term follow-up of 195 patients with renal failure: a preliminary report.

Abstract:

:Radiographic and bone mineral (BM) data were collected over a three-year period on 195 patients with chronic renal failure. Most women maintained BM on dyalysis, whereas 44% of the men lost BM (p less than 0.05). Following transplantation, 86% of the patients either maintained or restored BM. After parathyroidectomy, only half of the women and 34% of the men gained BM. Normal radiographs may be associated with low BM values, but there is a correlation between decreasing BM and increasing renal osteodystrophy in women (p less than 0.05).

journal_name

Radiology

journal_title

Radiology

authors

Griffiths HJ,Zimmerman RE,Lazarus M,Lowrie E,Gottlieb MN,Phillips E,Pomerantz K

doi

10.1148/122.3.643

subject

Has Abstract

pub_date

1977-03-01 00:00:00

pages

643-8

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

122

pub_type

杂志文章
  • Normal flow patterns of intracranial and spinal cerebrospinal fluid defined with phase-contrast cine MR imaging.

    abstract::A phase-contrast cine magnetic resonance (MR) imaging technique was used to study normal dynamics of cerebrospinal fluid (CSF) in 10 healthy volunteers and four patients with normal MR images. This pulse sequence yielded 16 quantitative flow-encoded images per cardiac cycle (peripheral gating). Flow encoding depicted ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.178.2.1987610

    authors: Enzmann DR,Pelc NJ

    更新日期:1991-02-01 00:00:00

  • Evaluation of renal transplants with ultrasound.

    abstract::Ultrasound scanning is useful in evaluating renal transplants: it is atraumatic, independent of renal function, and well suited for analyzing such common complications as lymphocele, abscess, hydronephrosis, and hematoma. When there is uncertainty as to the nature of a paranephric mass, ultrasonically guided percutane...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:

    authors: Bartrum RJ Jr,Smith EH,D'Orsi CJ,Tilney NL,Dantono J

    更新日期:1976-02-01 00:00:00

  • Acute and late effects of 16- and 50-MeVd leads to Be neutrons on the oral mucosa of rhesus monkeys.

    abstract::Twenty-five rhesus monkeys were randomly assigned to one of five treatment schedules: 1. control group, no irradiation, 2. 60Co five times weekly, 3. 60Co twice weekly, 4. 16-MeVd leads to Be neutrons twice weekly, and 5. 50-MeVd leads to Be neutrons twice weekly. Although the acute reactions were similar in the four ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.1.185

    authors: Jardine JH,Hussey DH,Boyd DD,Raulston GL,Davidson TJ

    更新日期:1975-10-01 00:00:00

  • Detection and classification of liquid-filled masses in the breast by gray scale echography.

    abstract::Gray scale ultrasonic visualization of the breast is a simple and safe technique for the detection of liquid-filled masses. Cysts and enlarged ducts as small as 2 mm in diameter can be reliably detected with a greater accuracy than is possible with any other imaging technique. The ultrasonic examination provides consi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.1.205

    authors: Jellins J,Kossoff G,Reeve TS

    更新日期:1977-10-01 00:00:00

  • Malignant carotid artery invasion: sonographic detection.

    abstract::To assess the reliability of sonography in the detection of absence of invasion of the carotid artery by tumor, high-resolution ultrasound, surgical, and pathologic findings were prospectively evaluated in 24 patients with disease metastatic to the neck. Sonography performed with 5- and 10-MHz transducers had a sensit...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.171.2.2649920

    authors: Gooding GA,Langman AW,Dillon WP,Kaplan MJ

    更新日期:1989-05-01 00:00:00

  • Calcified plaque: measurement of area at thin-section flat-panel CT and 64-section multidetector CT and comparison with histopathologic findings.

    abstract::The purpose of this study was to assess the blooming artifacts in ex vivo coronary arteries at multidetector computed tomography (CT) and flat-panel-volume CT by comparing measured areas of calcified plaque with respect to the reference standard of histopathologic findings. Three ex vivo hearts were scanned with multi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2483072003

    authors: Sarwar A,Rieber J,Mooyaart EA,Seneviratne SK,Houser SL,Bamberg F,Raffel OC,Gupta R,Kalra MK,Pien H,Lee H,Brady TJ,Hoffmann U

    更新日期:2008-10-01 00:00:00

  • Factors associated with academic radiology research productivity.

    abstract:PURPOSE:To determine factors associated with research productivity among all university radiology departments in the United States. MATERIALS AND METHODS:As an observational study, this was exempt from institutional review board approval. All 47,299 radiology articles from 1996 through 2003 that were indexed in the Na...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2373041508

    authors: Itagaki MW,Pile-Spellman J

    更新日期:2005-12-01 00:00:00

  • Medulloblastoma in infants and children: computed tomographic follow-up after treatment.

    abstract::Thirty-six proven cases of medulloblastoma were reviewed by serial CT follow-up examinations from 4 months to 10 years, 2 months after the initial diagnosis, with a mean follow-up time of 3 years, 9 months. The children ranged in age from 10 months to 16 years, 7 months at the time of follow-up. The tumor recurred at ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.3.3969470

    authors: Lee YY,Glass JP,van Eys J,Wallace S

    更新日期:1985-03-01 00:00:00

  • Radiological detection of aneurysms involving the aortic root.

    abstract::Dilatation of the aortic root, outlined by a periaortic fat layer, was observed in 19 of 25 successive cases of aneurysm of the ascending aorta. In one of these cases the aneurysm was entirely confined to the aortic root. In two other cases the aneurysms could not be detected on standard chest radiographs judged in th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.138.3.7465830

    authors: Szamosi A

    更新日期:1981-03-01 00:00:00

  • A technique for the estimation of fractional moving blood volume by using three-dimensional power Doppler US.

    abstract:PURPOSE:To (a) demonstrate an image-processing method that can automatically measure the power Doppler signal in a three-dimensional ( 3D three-dimensional ) ultrasonographic (US) volume by using the location of organs within the image and (b) compare 3D three-dimensional fractional moving blood volume ( FMBV fractiona...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14132363

    authors: Stevenson GN,Collins SL,Welsh AW,Impey LW,Noble JA

    更新日期:2015-01-01 00:00:00

  • Ultra-low peak voltage CT colonography: effect of iterative reconstruction algorithms on performance of radiologists who use anthropomorphic colonic phantoms.

    abstract:PURPOSE:To analyze the effect of a decrease in computed tomographic (CT) colonographic voltage, from 100 and 120 kVp to 80 kVp and reconstructed with filtered back projection ( FBP filtered back projection ), on radiation dose, image noise, and diagnostic performance in anthropomorphic phantoms and to assess the effect...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14140192

    authors: Shin CI,Kim SH,Lee ES,Lee DH,Hwang EJ,Chung SY,Lee JM,Han JK,Choi BI

    更新日期:2014-12-01 00:00:00

  • HLA-B27 associated arthropathies.

    abstract::The association between histo-compatibility antigens and disease is reviewed, in particular that between HLA-B27 and spondylitic disorders, i.e., ankylosing spondylitis, Reiter's arthritis, psoriatic arthritis, and ankylosing hyperostosis. We determined whether the presence of HLA-B27 predicted specific radiographic f...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/126.2.289

    authors: Schumacher TM,Genant HK,Kellet MJ,Mall JC,Fye KH

    更新日期:1978-02-01 00:00:00

  • Temporomandibular joint injuries.

    abstract::The clinical and radiologic findings in 30 patients who sustained injuries to the temporomandibular joint (TMJ) were retrospectively analyzed. Imaging consisted of variable combinations of radiography, tomography, two-compartment arthrography, computed tomography, and magnetic resonance imaging and was performed 2 day...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.1.2781010

    authors: Schellhas KP

    更新日期:1989-10-01 00:00:00

  • Thoracic radiographic changes after systemic hyperthermia for advanced cancer.

    abstract::Systemic hyperthermia is an adjuvant method of treatment used in the management of advanced cancer; the hyperthermic state is induced by either the thermal blanket or the external blood shunt method. Strict monitoring of the cardiopulmonary status, the temperature, and the fluid balance is necessary. Chest radiographs...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.1.3155480

    authors: Stark P,Guthrie AM,Bull J

    更新日期:1985-01-01 00:00:00

  • Correlation of Chest CT and RT-PCR Testing for Coronavirus Disease 2019 (COVID-19) in China: A Report of 1014 Cases.

    abstract::Background Chest CT is used in the diagnosis of coronavirus disease 2019 (COVID-19) and is an important complement to reverse-transcription polymerase chain reaction (RT-PCR) tests. Purpose To investigate the diagnostic value and consistency of chest CT as compared with RT-PCR assay in COVID-19. Materials and Methods ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020200642

    authors: Ai T,Yang Z,Hou H,Zhan C,Chen C,Lv W,Tao Q,Sun Z,Xia L

    更新日期:2020-08-01 00:00:00

  • The right paratracheal stripe.

    abstract::The right paratracheal stripe (RPS) is seen on postero-anterior chest radiographs as a thin, water-density stripe between the air column of the trachea and the adjacent right lung. The range of width of the RPS in 1,259 normal subjects was 1 to 4 mm. An RPS width of 5 mm or more is reliable evidence of disease. The di...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.2.295

    authors: Savoca CJ,Austin JH,Goldberg HI

    更新日期:1977-02-01 00:00:00

  • Detection of simulated chest lesions by using soft-copy reading: comparison of an amorphous silicon flat-panel-detector system and a storage-phosphor system.

    abstract:PURPOSE:To compare observer performance by using soft-copy images produced by an amorphous silicon flat-panel-detector system and a storage-phosphor system for the detection of simulated chest lesions. MATERIALS AND METHODS:To test the diagnostic performance of these two systems, four types of simulated lesions (nodul...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2241011441

    authors: Goo JM,Im JG,Lee HJ,Chung MJ,Seo JB,Kim HY,Lee YJ,Kang JW,Kim JH

    更新日期:2002-07-01 00:00:00

  • Characterization of Physiologic (18)F FSPG Uptake in Healthy Volunteers.

    abstract::Purpose To evaluate the normal biodistribution and kinetics of (S)-4-(3-[18F]fluoropropyl)-l-glutamic acid ((18)F FSPG) in healthy volunteers and to compare (18)F FSPG mean and maximum standardized uptake values (SUVmean and SUVmax, respectively) with those of (18)F fluorodeoxyglucose (FDG) across a variety of organs....

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015142000

    authors: Mosci C,Kumar M,Smolarz K,Koglin N,Stephens AW,Schwaiger M,Gambhir SS,Mittra ES

    更新日期:2016-06-01 00:00:00

  • False-positive screening mammograms: effect of immediate versus later work-up on patient stress.

    abstract:PURPOSE:To compare the stress experienced by women who had false-positive screening mammograms and had undergone immediate on-site diagnostic imaging evaluation with that experienced by those who had been recalled for subsequent imaging. MATERIALS AND METHODS:A retrospective survey was mailed to women with false-posit...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.218.1.r01ja35247

    authors: Lindfors KK,O'Connor J,Parker RA

    更新日期:2001-01-01 00:00:00

  • Important imaging finding e-mail alert system: experience after 3 years of implementation.

    abstract:PURPOSE:To evaluate the effectiveness of an important finding alert (IFA) system that uses e-mail technology to alert referring physicians to an important but nonurgent imaging finding. MATERIALS AND METHODS:The institutional review board approved the study; the requirement for informed consent was waived. The authors...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2531082217

    authors: Abujudeh HH,Kaewlai R,Choy G,Whelton DG,Rosenthal DI

    更新日期:2009-09-01 00:00:00

  • Evaluation of white matter anisotropy in Krabbe disease with diffusion tensor MR imaging: initial experience.

    abstract:PURPOSE:To compare diffusion tensor magnetic resonance imaging with conventional T2-weighted imaging for evaluation of white matter changes in patients with Krabbe disease. MATERIALS AND METHODS:In eight patients with Krabbe disease and eight age-matched control subjects, anisotropy maps were generated with diffusion ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.218.3.r01mr14809

    authors: Guo AC,Petrella JR,Kurtzberg J,Provenzale JM

    更新日期:2001-03-01 00:00:00

  • Gray-scale ultrasonography and endoscopic pancreatography in pancreatic diagnosis.

    abstract::Ultrasonography and endoscopic retrograde cholangiopancreatography (ERCP) were performed in 216 patients with known or suspected pancreatic disease. Both techniques provided accurate information in all groups of patients (normals and those with recurrent acute pancreatitis, chronic pancreatitis, and cancer), and there...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.134.2.7352230

    authors: Cotton PB,Lees WR,Vallon AG,Cottone M,Croker JR,Chapman M

    更新日期:1980-02-01 00:00:00

  • Predicting Retear after Repair of Full-Thickness Rotator Cuff Tear: Two-Point Dixon MR Imaging Quantification of Fatty Muscle Degeneration-Initial Experience with 1-year Follow-up.

    abstract::Purpose To determine the degree of preoperative fatty degeneration within muscles, postoperative longitudinal changes in fatty degeneration, and differences in fatty degeneration between patients with full-thickness supraspinatus tears who do and those who do not experience a retear after surgery. Materials and Method...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016151789

    authors: Nozaki T,Tasaki A,Horiuchi S,Ochi J,Starkey J,Hara T,Saida Y,Yoshioka H

    更新日期:2016-08-01 00:00:00

  • Autoimmune lymphoproliferative syndrome: a syndrome associated with inherited genetic defects that impair lymphocytic apoptosis--CT and US features.

    abstract:PURPOSE:To describe the imaging findings in patients with autoimmune lymphoproliferative syndrome (ALPS) and to relate the findings to the clinical and genetic features of this recently recognized syndrome. MATERIALS AND METHODS:Retrospective or prospective reviews of the computed tomographic (CT) and ultrasonographic...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.212.1.r99jl40257

    authors: Avila NA,Dwyer AJ,Dale JK,Lopatin UA,Sneller MC,Jaffe ES,Puck JM,Straus SE

    更新日期:1999-07-01 00:00:00

  • Effects of negative pi mesons on immune responses in mice.

    abstract::Spleen cells from normal or preimmunized mice were exposed to graded doses of peak pions or 300-kVp x rays in vitro and then cultured in heavily irradiated mice to determine antibody production against sheep erythrocytes. The RBE for the primary antibody response was 1.46. Equal suppression of secondary responses was ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/126.3.803

    authors: Carlson DE

    更新日期:1978-03-01 00:00:00

  • Limited small cell lung cancer: prognostic significance of a complete response to the induction phase of chemotherapy followed by thoracic irradiation.

    abstract::Limited-stage small cell lung cancer is frequently treated with induction combination chemotherapy (ICC), followed by consolidation with thoracic irradiation. It has been suggested that patients who do not have a complete response to ICC are unlikely to have control of occult distant metastasis and consequently have s...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiology.178.3.1847240

    authors: Armstrong JG,Rosenstein MM,Scher HI,Fass DE,Zelefsky MJ,Kris MG

    更新日期:1991-03-01 00:00:00

  • Heterogeneity in the campomelic syndromes. Long-and short-bone varieties.

    abstract::Analysis of 9 cases of bilateral bent limbs (campomelia) and dwarfism, as well as a review of the literature, indicate that campomelic syndrome appears to be a well-defined distinct disorder which the authors call long-limbed campomelic syndrome. Other neonates with congenital bent-limbed dwarfism can be classified as...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/120.3.641

    authors: Khajavi A,Lachman R,Rimoin D,Schimke RN,Dorst J,Handmaker S,Ebbin A,Perreault G

    更新日期:1976-09-01 00:00:00

  • Posterior circulation in moyamoya disease: angiographic study.

    abstract:PURPOSE:To clarify the angiographic findings of the posterior circulation in patients with moyamoya disease. MATERIALS AND METHODS:Seventy-six patients with idiopathic moyamoya disease were studied with conventional angiography. The angiographic findings were reviewed for steno-occlusive lesions, collateral vessels, a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.1.7568830

    authors: Yamada I,Himeno Y,Suzuki S,Matsushima Y

    更新日期:1995-10-01 00:00:00

  • Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: initial experience.

    abstract::The authors investigated the contrast enhancement characteristics of the coronary artery stent lumen to assess patency and then evaluated the accuracy of computed tomographic (CT) measurement of the in-stent luminal diameter. Nineteen patients (16 men and three women; mean age, 58.7 years) with 26 stents underwent car...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2331031564

    authors: Hong C,Chrysant GS,Woodard PK,Bae KT

    更新日期:2004-10-01 00:00:00

  • Comparison of scanning equalization and conventional chest radiography.

    abstract::A clinical comparison study of scanning equalization radiography (SER) and conventional chest radiography was performed with the latest prototype SER system. Conventional chest radiography was performed at 120 kVp with Lanex regular screens (Eastman Kodak, Rochester, NY) and Kodak Ortho-G or Ortho-C film (Eastman Koda...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.172.3.2772170

    authors: Wandtke JC,Plewes DB

    更新日期:1989-09-01 00:00:00