Abstract:
PURPOSE:To determine the diagnostic efficacy of hard- and soft-copy computed radiographic (CR) images versus conventional screen-film images of the chest in the detection of subtle pulmonary abnormalities. MATERIALS AND METHODS:Twenty observes compared 87 hard-copy and soft-copy CR images with hard-copy screen-film images. Of 87 test images, 45 (including two identical sets of 12 images to test intra-observer variability) were abnormal and 42 (including two identical sets of 12 images) were normal. Of the 45 abnormal images, 15 (including two sets of four identical images) showed subtle abnormalities, 15 (including two sets of four identical images) showed mild abnormalities, and 15 (including two sets of four identical images) showed obvious abnormalities. Soft-copy viewing provided three differently processed images of every radiograph. RESULTS:No statistically significant differences in receiver operating characteristic analyses were found among hard-copy screen-film images, hard-copy CR images, and soft-copy CR images, even in the group with subtle interstitial abnormalities. CONCLUSION:Hard-copy and soft-copy chest CR images are acceptable and available in place of screen-film images for primary interpretation of subtle interstitial lung diseases.
journal_name
Radiologyjournal_title
Radiologyauthors
Ishigaki T,Endo T,Ikeda M,Kono M,Yoshida S,Ikezoe J,Murata K,Matsumoto Mdoi
10.1148/radiology.201.1.8816520subject
Has Abstractpub_date
1996-10-01 00:00:00pages
51-60issue
1eissn
0033-8419issn
1527-1315journal_volume
201pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::The authors present a case of congenital bronchopulmonary foregut malformation with pulmonary artery blood supply and pulmonary venous drainage in a five-month-old boy. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/114.2.423
更新日期:1975-02-01 00:00:00
abstract::Given the increasing diversification of computers in most areas of radiology, the ability to solve problems resulting from incompatibility between systems is becoming essential. Manufacturers should supply hardware and software documentation to allow connections between different systems and give the radiology departm...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.139.2.7220900
更新日期:1981-05-01 00:00:00
abstract:PURPOSE:To present data from the first prospective pilot phase trial of breast cancer participants imaged with fluorine 18 ((18)F)-2-fluoropropionyl-labeled PEGylated dimeric arginine-glycine-aspartic acid ( RGD arginine-glycine-aspartic acid ) peptide (PEG3-E[c{ RGD arginine-glycine-aspartic acid yk}]2) ( FPPRGD2 2-fl...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14140028
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:To prospectively assess which phase of a triple-phase dynamic contrast material-enhanced multi-detector row computed tomography (CT) protocol is optimal for visualization of esophageal cancer. MATERIALS AND METHODS:The study was supported by the local ethical committee; all patients gave written informed conse...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2393050222
更新日期:2006-06-01 00:00:00
abstract::Nineteen patients with unequivocal angiographic evidence of unilateral or bilateral posterior cerebral artery occulsion were scanned during the acute phase of the stroke. In 12 of them an abnormal accumulation of radioactivity was apparent on the posterior view, but only 2 also exhibited abnormal uptake on the corresp...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/123.2.393
更新日期:1977-05-01 00:00:00
abstract::A simple method of shielding the hand during cross-compression angiography is described. A standard lead glove with the fingertips cut out of the palmar aspect is used, allowing sensation and mobility while still protecting the hand. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/128.2.509
更新日期:1978-08-01 00:00:00
abstract::Online supplemental material is available for this article. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015151030
更新日期:2015-10-01 00:00:00
abstract:PURPOSE:To determine characteristic features of peripheral cholangiocarcinoma on two-phase spiral computed tomographic (CT) scans. MATERIALS AND METHODS:Thirty-four patients with peripheral cholangiocarcinoma underwent two-phase spiral CT. Hepatic arterial phase and portal venous phase images were obtained 30 and 65 s...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.204.2.9240550
更新日期:1997-08-01 00:00:00
abstract::High-resolution, real-time sonography of the rotator cuff was performed in 51 shoulders, and the results were correlated with findings obtained during subsequent surgery. Prospective sensitivity of sonography in detection of a tear was 100%; specificity, 75%; and accuracy, 92%. Retrospective estimation of tear size on...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.169.3.3055040
更新日期:1988-12-01 00:00:00
abstract:PURPOSE:To evaluate a technique to perform fluoroscopically directed thoracic transforaminal epidural injections. MATERIALS AND METHODS:Institutional review board approval and a waiver of consent were obtained for this retrospective HIPAA-compliant study. Findings from 198 consecutively performed foraminal nerve block...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.09082085
更新日期:2010-02-01 00:00:00
abstract::A presumed new radiological-pathological entity of atherosclerotic subintimal of the carotid artery is described. Subintimal hematomas were found in 12 of 50 (24%) carotid bifurcations during surgery for repeated transient ischemic attacks in a single hemispheric distribution; only 33% were associated with ulcerations...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/133.1.123
更新日期:1979-10-01 00:00:00
abstract::This introduction to biostatistics and measurement is the first in a series of articles designed to provide Radiology readers with a basic understanding of statistical concepts. Although most readers of the radiology literature know that application of study results to their practice requires an understanding of stati...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2252010933
更新日期:2002-11-01 00:00:00
abstract::The magnetic resonance (MR) examinations of 18 patients with dilated bile ducts were reviewed retrospectively to determine the capability of MR to demonstrate biliary dilatation, assess MR appearance of the dilated biliary tract using spin-echo techniques, and define the optimal MR imaging parameters (repetition time ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.158.2.3941860
更新日期:1986-02-01 00:00:00
abstract::Purpose To compare the diagnostic performance of minimally invasive autopsy with that of conventional autopsy. Materials and Methods For this prospective, single-center, cross-sectional study in an academic hospital, 295 of 2197 adult cadavers (mean age: 65 years [range, 18-99 years]; age range of male cadavers: 18-99...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2018180924
更新日期:2018-12-01 00:00:00
abstract:PURPOSE:To assess computed tomography (CT) with iodized oil for depiction of small hepatocellular carcinoma (HCC) before liver transplantation. MATERIALS AND METHODS:Thirty-five consecutive cirrhotic patients underwent CT with iodized oil to determine the presence, number, size, and location of possible nodules. All p...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.197.2.7480680
更新日期:1995-11-01 00:00:00
abstract::The authors examined 10 healthy male subjects with dynamic computed tomography to determine normal dynamic and expiratory findings. In both the supine and prone positions, the average increase in lung attenuation during exhalation was found to be significantly greater in dependent lung regions than in nondependent lun...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.186.1.8416550
更新日期:1993-01-01 00:00:00
abstract::Possible signs of paratracheal lymphadenopathy on the posteroanterior (PA) chest radiograph were assessed in 98 patients and correlated with computed tomography (CT). The nodes were normal in size in 62 patients and enlarged (greater than 15 mm) in 36. Among the latter group, widening of the right paratracheal stripe ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.156.3.4023240
更新日期:1985-09-01 00:00:00
abstract::Excretory urography could be performed less frequently if some combinations of genitourinary signs and symptoms were found to be predictive of either a specific disease or normality. To explore this possibility, the authors conducted a prospective study involving more than 3,000 patients at three institutions (a teach...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.154.3.3969460
更新日期:1985-03-01 00:00:00
abstract::Computed tomography (CT) is the modality of choice for evaluation of pancreatic disease. In this prospective study, images obtained with spiral CT, which enables examination of a region of the body in a single breath-hold, were compared with those obtained by means of dynamic CT with automatic table incrementation in ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.183.3.1584940
更新日期:1992-06-01 00:00:00
abstract::The authors obtained sagittal magnetic resonance (MR) images twice a week from six healthy women during one full menstrual cycle to establish the changes depicted in the uterine layers. Parallel endocrine and ultrasound studies were used to establish the day of ovulation precisely. Consistent changes in the thickness ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.161.2.3532190
更新日期:1986-11-01 00:00:00
abstract::Methyl glucamine sodium diatrizoate (Renografin 76) was directly infused into the isolated arteries to the sino-atrial and atrioventricular nodes of anesthetized dogs, causing a dose-related inhibition of sino-atrial nodal automaticity and atrioventricular nodal conductivity; these effects were not attenuated by auton...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/121.1.205
更新日期:1976-10-01 00:00:00
abstract::A new technique for the determination of bone mineral density, based on the detection of both coherently and Compton scattered photons in a narrow beam geometry, is described. Initial results show that this method delivers an accuracy of less than 2% when varying quantities of materials surround the measuring site. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/120.3.723
更新日期:1976-09-01 00:00:00
abstract::Pedal lymphography was performed without the use of vital dyes in 510 patients. Lymphatic vessels were still readily identifiable by this method, due to their transparency, clarity, elasticity, distensibility, and characteristic branching pattern. Procedure time was shortened by 10-15 minutes without compromising the ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/133.3.795
更新日期:1979-12-01 00:00:00
abstract::Diagnostic quality of radiographs and adverse reactions associated with the use of metrizamide and iohexol as contrast agents in lumbar myelography were compared in a prospective randomized double blind study in 350 patients at seven centers. The contrast media were administered in comparable volumes at a concentratio...
journal_title:Radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1148/radiology.151.3.6371890
更新日期:1984-06-01 00:00:00
abstract:PURPOSE:To assess the value of clinical, chest radiographic, and computed tomographic (CT) findings in classifying chronic diffuse infiltrative lung disease (CDILD) MATERIALS AND METHODS: Two samples from the same population were consecutively studied: the training set (group A, n = 208) for the development of the deci...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.191.2.8153310
更新日期:1994-05-01 00:00:00
abstract:PURPOSE:To retrospectively evaluate the sensitivity of computer-aided detection (CAD) in depicting ductal carcinoma in situ (DCIS) on screening mammograms by using biopsy proved lesion location as the reference standard. MATERIALS AND METHODS:Institutional review board approval was obtained, with a waiver of patient i...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2413051366
更新日期:2006-12-01 00:00:00
abstract::The critical aspects of selection, acceptance testing, and quality control of a radiotherapy treatment simulator are discussed. The selection of a simulator involves consideration of: (a) motions and readouts, (b) safety features, (c) x-ray and imaging systems, and (d) mechanical tolerances (including guarantees). Whe...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/131.1.221
更新日期:1979-04-01 00:00:00
abstract::An inflammatory polyps of the renal pelvis that caused a mass effect at excretory urography simulated transitional cell carcinoma. In the differential diagnoses of intracalyceal masses, therefore, inflammatory polyp must be considered. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.144.3.7100460
更新日期:1982-08-01 00:00:00
abstract:PURPOSE:To investigate the diagnostic value of technetium 99m-labeled human serum albumin (HSA) scintigraphy in a group of patients suspected of having protein-losing enteropathy (PLE). MATERIALS AND METHODS:After intravenous injection of 740 MBq of freshly prepared (99m)Tc HSA, serial images of the abdomen were obtai...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.219.1.r01ap2986
更新日期:2001-04-01 00:00:00
abstract::Sixty-five patients with suspected ear disease were examined with CT, and abnormalities were detected in 42 of them; 58 of these patients also had pluridirectional tomographic examinations. Eighteen of the patients in whom abnormalities were detected underwent exploratory surgery. CT was useful in the diagnosis of tym...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.147.3.6844610
更新日期:1983-06-01 00:00:00