Abstract:
PURPOSE:To present data from the first prospective pilot phase trial of breast cancer participants imaged with fluorine 18 ((18)F)-2-fluoropropionyl-labeled PEGylated dimeric arginine-glycine-aspartic acid ( RGD arginine-glycine-aspartic acid ) peptide (PEG3-E[c{ RGD arginine-glycine-aspartic acid yk}]2) ( FPPRGD2 2-fluoropropionyl labeled PEGylated dimeric RGD peptide (PEG3-E[c{RGDyk}]2) ), a radiopharmaceutical agent used in positron emission tomographic (PET) imaging. MATERIALS AND METHODS:The local institutional review board approved the HIPAA-compliant protocol. Written informed consent was obtained from each patient. Eight women (age range, 44-67 years; mean age, 54.3 years ± 8.8 [standard deviation]) with newly diagnosed or recurrent breast cancer were recruited between November 2010 and February 2011. (18)F- FPPRGD2 2-fluoropropionyl labeled PEGylated dimeric RGD peptide (PEG3-E[c{RGDyk}]2) PET/computed tomographic (CT) and (18)F-fluorodeoxyglucose ( FDG fluorine 18 fluorodeoxyglucose ) PET/CT examinations were performed within 3 weeks of each other. Dynamic (18)F- FPPRGD2 2-fluoropropionyl labeled PEGylated dimeric RGD peptide (PEG3-E[c{RGDyk}]2) PET and two whole-body static (18)F- FPPRGD2 2-fluoropropionyl labeled PEGylated dimeric RGD peptide (PEG3-E[c{RGDyk}]2) PET/CT scans were obtained. During this time, vital signs and electrocardiograms were recorded at regular intervals. Blood samples were obtained before the injection of (18)F- FPPRGD2 2-fluoropropionyl labeled PEGylated dimeric RGD peptide (PEG3-E[c{RGDyk}]2) and at 24 hours and 1 week after injection to evaluate for toxicity. A nonparametric version of multivariate analysis of variance was used to assess the safety outcome measures simultaneously across time points. A paired two-sample t test was performed to compare the maximum standardized uptake values ( SUVmax maximum standardized uptake value ). RESULTS:(18)F- FPPRGD2 2-fluoropropionyl labeled PEGylated dimeric RGD peptide (PEG3-E[c{RGDyk}]2) was well tolerated, without noticeable changes in vital signs, on electrocardiograms, or in laboratory values. A total of 30 lesions were evaluated at (18)F- FDG fluorine 18 fluorodeoxyglucose PET/CT and (18)F- FPPRGD2 2-fluoropropionyl labeled PEGylated dimeric RGD peptide (PEG3-E[c{RGDyk}]2) PET/CT. The primary breast lesions had (18)F- FPPRGD2 2-fluoropropionyl labeled PEGylated dimeric RGD peptide (PEG3-E[c{RGDyk}]2) uptake with SUVmax maximum standardized uptake value of 2.4-9.4 (mean, 5.6 ± 2.8) 60 minutes after injection, compared with (18)F- FDG fluorine 18 fluorodeoxyglucose uptake with SUVmax maximum standardized uptake value of 2.8-18.6 (mean, 10.4 ± 7.2). Metastatic lesions also showed (18)F- FPPRGD2 2-fluoropropionyl labeled PEGylated dimeric RGD peptide (PEG3-E[c{RGDyk}]2) uptake, with SUVmax maximum standardized uptake value of 2.4-9.7 (mean, 5.0 ± 2.3) at 60 minutes, compared with (18)F- FDG fluorine 18 fluorodeoxyglucose uptake with SUVmax maximum standardized uptake value of 2.2-14.6 (mean, 6.6 ± 4.2). CONCLUSION:Data from this pilot phase study suggest that (18)F- FPPRGD2 2-fluoropropionyl labeled PEGylated dimeric RGD peptide (PEG3-E[c{RGDyk}]2) is a safe PET radiopharmaceutical agent. Evaluation of (18)F- FPPRGD2 2-fluoropropionyl labeled PEGylated dimeric RGD peptide (PEG3-E[c{RGDyk}]2) in participants with breast cancer demonstrated significant uptake in the primary lesion and in the metastases. Larger cohorts are required to confirm these preliminary findings.
journal_name
Radiologyjournal_title
Radiologyauthors
Iagaru A,Mosci C,Shen B,Chin FT,Mittra E,Telli ML,Gambhir SSdoi
10.1148/radiol.14140028subject
Has Abstractpub_date
2014-11-01 00:00:00pages
549-59issue
2eissn
0033-8419issn
1527-1315journal_volume
273pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract:PURPOSE:Magnetic resonance (MR) images were correlated with results of fine-needle aspiration (FNA) to determine the role of MR imaging in evaluating hepatic neoplasms treated with percutaneous ethanol ablation therapy (PEAT). MATERIALS AND METHODS:Contrast material-enhanced and unenhanced MR images were obtained in 1...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.189.1.7690490
更新日期:1993-10-01 00:00:00
abstract:PURPOSE:To determine whether apparent diffusion coefficient (ADC) values vary according to tumor-stroma ratio, dominant stroma type, or presence of central fibrosis in estrogen receptor-positive breast cancer. MATERIALS AND METHODS:Institutional review board approval was obtained, and patient consent was waived. Sixty...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.13131073
更新日期:2014-04-01 00:00:00
abstract::The chest radiographs of asthmatic patients in an emergency room setting over a four-year period were reviewed. A total of 997 radiographs was reviewed; radiographic findings were compared with history and clinical data. In adults 2.2% of the radiographs were abnormal; in children 13%. It is concluded that a chest rad...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.145.1.7122890
更新日期:1982-10-01 00:00:00
abstract:PURPOSE:To determine whether addition of quality measure (QM) of shear-wave (SW) velocity (Vs) estimation can increase SW elastography sensitivity for breast cancer. MATERIALS AND METHODS:With written informed consent, this institutional review board-approved, HIPAA-compliant study included 143 women (mean age, 48.5 y...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14132404
更新日期:2015-04-01 00:00:00
abstract:PURPOSE:To evaluate the accuracy of 64-section multidetector computed tomography (CT) for the assessment of perfusion defects (PDs), regional wall motion (RWM), and global left ventricular (LV) function. MATERIALS AND METHODS:All myocardial infarction (MI) patients signed informed consent. The IRB approved the study a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2482071478
更新日期:2008-08-01 00:00:00
abstract:PURPOSE:To evaluate fluorine 18 ((18)F) dihydroxyphenylalanine (DOPA) whole-body positron emission tomography (PET) as a biochemical imaging approach for detection of pheochromocytomas. MATERIALS AND METHODS:(18)F DOPA PET and magnetic resonance (MR) imaging were performed in 14 consecutive patients suspected of havin...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2222010622
更新日期:2002-02-01 00:00:00
abstract:PURPOSE:To determine if a correlation exists between the number of previous enhanced magnetic resonance (MR) imaging examinations and high signal intensity in the globus pallidus (GP) and dentate nucleus (DN) in patients who received gadodiamide (Omniscan), a linear nonionic gadolinium-based contrast agent, and in thos...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015150872
更新日期:2015-09-01 00:00:00
abstract:PURPOSE:To evaluate the local tumor control and survival data for magnetic resonance (MR) imaging-guided laser-induced interstitial thermotherapy (LITT) of colorectal liver metastases. MATERIALS AND METHODS:MR imaging-guided LITT was performed in 603 patients (mean age, 61.2 years) with 1,801 liver metastases of color...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2302020646
更新日期:2004-02-01 00:00:00
abstract:PURPOSE:To identify the complications and imaging findings related to lymphangioleiomyomatosis (LAM) after lung transplantation. MATERIALS AND METHODS:The authors retrospectively reviewed the clinical histories and imaging studies of 13 patients from five major medical centers who underwent unilateral (n = 8) or bilat...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.210.2.r99fe11325
更新日期:1999-02-01 00:00:00
abstract::A stereotaxic frame, compatible with digital subtraction angiography, computed tomography, and magnetic resonance imaging, is described along with a set of software programs that run in an independent imaging computer system, as well as in the computers associated with each modality. Plexiglas plates fastened to the s...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.161.3.3538140
更新日期:1986-12-01 00:00:00
abstract:PURPOSE:To assess how early pleural and/or parenchymal abnormalities consistent with asbestos exposure could be ascertained and to identify factors associated with progression. MATERIALS AND METHODS:Informed consent was obtained under an institutional review board-approved protocol. Multiple sequential chest radiograp...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10091447
更新日期:2010-06-01 00:00:00
abstract::Internal contamination by 131I among the personnel in a nuclear medicine laboratory was surveyed from January to July, 1979. Because of the formulation change made by the manufacturer in April to reduce volatility, it was possible to study two different therapeutic solutions of 131I. Internal contamination of personne...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.137.3.7444060
更新日期:1980-12-01 00:00:00
abstract::Ten percent of children with biliary atresia have an associated complex of anomalies, including polysplenia, azygous continuation of the inferior vena cava, preduodenal portal vein, hepatic arterial anomalies, and bilaterally bilobed lungs. These abnormalities will not be detected if the preoperative workup is limited...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.163.2.3550880
更新日期:1987-05-01 00:00:00
abstract:PURPOSE:To describe thin-section pulmonary computed tomographic (CT) features in asymptomatic elderly individuals. MATERIALS AND METHODS:Institutional review board approval was given, and informed consent was obtained. Two study groups (older group, over 75 years of age; younger group, under 55 years) were prospective...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2512081242
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:To determine if magnetic resonance (MR) imaging findings of soft-tissue sarcoma involving bone or neurovascular structures allow prediction of local recurrence, distant metastasis, or disease-specific survival. MATERIALS AND METHODS:Preoperative MR images of 46 patients with soft-tissue sarcoma were reviewed f...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.205.3.9393550
更新日期:1997-12-01 00:00:00
abstract::Radiographs and CT images taken during oral cholecystography in dogs were interpreted in an independent, blind fashion by three radiologists on two occasions and visual assessment of gallbladder density compared to the actual CT values. While there was significant intra- and inter-observer variation, the mean scores f...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.144.2.7089280
更新日期:1982-07-01 00:00:00
abstract::In ten rabbit ears the central auricular artery was percutaneously catheterized and subjected to doses of laser energy transmitted through a flexible optical fiber within the artery. Arterial occlusion was not produced in the initial three ears using energy levels less than 600 mW. Higher levels of laser energy, in th...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.142.3.7199750
更新日期:1982-03-01 00:00:00
abstract:PURPOSE:To compare the accuracies of whole-body 2-[fluorine 18]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) and conventional imaging (thoracic computed tomography [CT], bone scintigraphy, and brain CT or magnetic resonance [MR] imaging) in staging bronchogenic carcinoma. MATERIALS AND METHODS:With...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.212.3.r99se21803
更新日期:1999-09-01 00:00:00
abstract:PURPOSE:To evaluate the effectiveness, cost, and cost-effectiveness of using renal mass biopsy to guide treatment decisions for small incidentally detected renal tumors. MATERIALS AND METHODS:A decision-analytic Markov model was developed to estimate life expectancy and lifetime costs for patients with small (< or = 4...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10092013
更新日期:2010-09-01 00:00:00
abstract::Methyl glucamine sodium diatrizoate (Renografin 76) was directly infused into the isolated arteries to the sino-atrial and atrioventricular nodes of anesthetized dogs, causing a dose-related inhibition of sino-atrial nodal automaticity and atrioventricular nodal conductivity; these effects were not attenuated by auton...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/121.1.205
更新日期:1976-10-01 00:00:00
abstract::Pulmonary arteriography is an invasive but relatively safe diagnostic procedure. It is generally believed that the presence of pulmonary hypertension is one risk factor that increases the likelihood of a major complication. To assess the magnitude of risk, the reports on 1,434 patients who underwent pulmonary arteriog...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.162.1.3786760
更新日期:1987-01-01 00:00:00
abstract::The relationship of the brain angiographic mode circulation time (AVCT) to the mean transit time of the vascular indicator C15O-labeled hemoglobin (tc15o) and the regional cerebral blood flow (rCBF) as measured by the clearance of the diffusible tracer H2-15O was examined in 38 patients with selected cerebral diseases...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/115.1.107
更新日期:1975-04-01 00:00:00
abstract::Extracranial duplication of the vertebral artery was demonstrated angiographically on both sides in a patient with postmeningitis hydrocephalus and in another with hemangioblastoma. Forty-six cases of this anomaly are reviewed. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/131.2.408
更新日期:1979-05-01 00:00:00
abstract:PURPOSE:To prospectively evaluate the effectiveness and safety of selective embolization of the uterine arteries in the management of symptomatic uterine leiomyoma. MATERIALS AND METHODS:Eighty consecutive women (mean age, 44.7 years) with symptomatic uterine leiomyoma, none of whom desired future pregnancy, underwent...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.215.2.r00ma11428
更新日期:2000-05-01 00:00:00
abstract::A review of 210 chest computed tomographic (CT) examinations demonstrating upper chest masses revealed 16 cases of superior vena caval obstruction (SVCO); 11 of these were clinically occult. Two of the occult cases subsequently became clinically evident. Contrast-enhanced chest CT permits the diagnosis of clinically o...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.157.2.4048460
更新日期:1985-11-01 00:00:00
abstract::Transient sonographic abnormalities of the urinary bladder in children can be identified immediately after performance of voiding cystourethrography. Both cystic and solid masses may be mimicked by transient hematuria induced by minor, cystography-related trauma. After the bladder has been emptied and refilled, reexam...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.159.1.3513250
更新日期:1986-04-01 00:00:00
abstract::As computer networks become an integral part of the radiology practice, it is appropriate to raise concerns regarding their security. The purpose of this article is to present an overview of computer network security risks and preventive strategies as they pertain to the radiology enterprise. A number of technologies ...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiology.220.2.r01au32303
更新日期:2001-08-01 00:00:00
abstract::Renal failure induced by intravenous iodinated contrast media is a frequent medical problem. While such cases are generally reported first by the clinician, the phenomenon can be seen even earlier by the radiologist. An abnormally persistent nephrogram is a sign of abnormal clearance, which in turn should alert the ph...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/131.2.553
更新日期:1979-05-01 00:00:00
abstract::Purpose To examine the relation between the lung elimination rate of inhaled technetium 99m ((99m)Tc)-sestamibi and immunohistochemical expression of bronchopulmonary multidrug resistance protein 1 (MRP1) and permeability glycoprotein (P-gp) and assess the repeatability of the inhaled (99m)Tc-sestamibi clearance techn...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.16151389
更新日期:2016-09-01 00:00:00
abstract::Background Patients with wrist trauma and negative findings on radiographs often undergo additional MRI examinations to assess for radiographically occult fractures. Dual-energy CT may be more readily available than MRI in some settings. Purpose To evaluate the diagnostic test accuracy of dual-energy CT in helping det...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2020192701
更新日期:2020-09-01 00:00:00