Comparison of various methods for the enumeration of blood cells in urine.

Abstract:

:This study compared the use of conventional urine microscopy, the KOVA system, Neubauer hemacytometry, and the Yellow IRIS for the determination of white blood cell (WBC) and red blood cell (RBC) counts in urine samples. Both KOVA WBC and RBC counts correlated better with the IRIS counts than with conventional microscopy. KOVA WBC counts correlated with Neubauer hemacytometry to the same degree as they did with IRIS WBC counts. The RBC count correlation was fairly similar between KOVA, hemacytometry, and the conventional method. It was concluded that the KOVA system is a suitable replacement for conventional urine microscopy.

journal_name

J Clin Lab Anal

authors

McGinley M,Wong LL,McBride JH,Rodgerson DO

doi

10.1002/jcla.1860060604

subject

Has Abstract

pub_date

1992-01-01 00:00:00

pages

359-61

issue

6

eissn

0887-8013

issn

1098-2825

journal_volume

6

pub_type

杂志文章
  • Free circulating tumor DNA as a diagnostic marker for breast cancer.

    abstract:BACKGROUND:Cell-free DNA (cfDNA) in the plasma of patients with both malignant and benign breast lesions was analyzed to determine whether the findings may have diagnostic and prognostic implications and to analyze the association between the levels of cfDNA and prognostic parameters. METHODS:Plasma samples were obtai...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21548

    authors: Hashad D,Sorour A,Ghazal A,Talaat I

    更新日期:2012-11-01 00:00:00

  • Effect of temperature on lysosomal enzyme activity during preparation and storage of dried blood spots.

    abstract:BACKGROUND:The use of dried blood spots (DBS) for the assay of lysosomal enzymes has facilitated the implementation of pilot studies for newborn screening for lysosomal storage disorders in various developed countries. The aim of the study was to determine the influence of ambient temperature during DBS preparation and...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22220

    authors: Supriya M,De T,Christopher R

    更新日期:2018-01-01 00:00:00

  • Isolation of porcine pancreatic islets: low trypsin activity during the isolation procedure guarantees reproducible high islet yields.

    abstract::During the past few years, interest in xenotransplantation of porcine islets of Langerhans for the future therapy of type I diabetes has increased markedly. Therefore, we established a semiautomated digestion method for isolating islets from the porcine pancreas. However, although the isolation technique was standardi...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860080611

    authors: Heiser A,Ulrichs K,Müller-Ruchholtz W

    更新日期:1994-01-01 00:00:00

  • Long non-coding RNAE330013P06 promotes progression of breast cancer with type 2 diabetes.

    abstract:BACKGROUND:In previous research, we found diabetes rather than obesity was an independent risk factor of breast cancer. However, why diabetes could lead to increased risk of breast cancer patients remains elusive. Long non-coding RNAE330013P06 has been shown to be upregulated in diabetes, and long non-coding RNAs gener...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23172

    authors: Chen R,Shi P,Zhang Y,Wu H,Li X,Yang W,Luo F,JinmingXue,Yao L,Yang J,Wang W,Zhang B,Li P,Miao Y,Wang Q,Tian F

    更新日期:2020-05-01 00:00:00

  • Nontreponemal tests in the diagnosis of neurosyphilis: an evaluation of the Venereal Disease Research Laboratory (VDRL) and the Rapid Plasma Reagin (RPR) tests.

    abstract::The Venereal Disease Research Laboratory (VDRL) test has long been considered the best serological test for the diagnosis of neurosyphilis. The goal of this study was to find out if the Rapid Plasma Reagin (RPR) could be an alternative to the VDRL. Cerebrospinal fluid (CSF) and sera samples from patients in the follow...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20254

    authors: Castro R,Prieto ES,da Luz Martins Pereira F

    更新日期:2008-01-01 00:00:00

  • Variable-region subgroup distribution among lambda-type immunoglobulins in normal human serum.

    abstract::The distribution of the major VL subgroups (V lambda I, V lambda II, V lambda III, V lambda IV, V lambda VI, and V lambda VIII) among lambda-type immunoglobulins (Igs) in normal serum was determined by a sandwich enzyme-linked immunosorbent assay (ELISA) using a panel of murine anti-human V lambda-subgroup-specific mo...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860080103

    authors: Abe M,Ozaki S,Wolfenbarger D,deBram-Hart M,Weiss DT,Solomon A

    更新日期:1994-01-01 00:00:00

  • Performance evaluation of Mindray CAL 8000(BC-6800 and SC-120) hematology analyzer and slidemaker/stainer.

    abstract:INTRODUCTION:The Mindray CAL 8000 is a cellular analysis line that consists of the BC-6800, an automated hematology analyzer, and the SC-120, an automated slidemaker/stainer. We evaluated the performances of the BC-6800 and the SC-120. METHODS:Four hundred and eight normal and abnormal samples were analyzed. The perfo...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22065

    authors: Lee HT,Park PW,Seo YH,Kim KH,Seo JY,Jeong JH,Kim MJ,Ahn JY

    更新日期:2017-07-01 00:00:00

  • Investigation of Rotavirus with Various Methods in Children with Acute Gastroenteritis and Determination of Its Molecular Epidemiology in Kayseri Province, Turkey.

    abstract:BACKGROUND:In this study, the fresh stool samples from 254 children under 5 years of age with acute gastroenteritis which were delivered between October 2012 and December 2013 were collected. METHODS:In the stool samples, rotavirus antigens were investigated using two different immunochromatographic methods which are ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22030

    authors: Artiran S,Atalay A,Gökahmetoglu S,Ozturk MA,Balci N,Cakir N,Kilic H,Durmaz R

    更新日期:2017-03-01 00:00:00

  • Diagnostic and prognostic role of serum glypican 3 in patients with hepatocellular carcinoma.

    abstract::α-Feto protein (AFP) is the widely used tumor marker in the diagnosis of hepatocellular carcinoma (HCC). The aim of this study was to assess the diagnostic and prognostic validity of a novel marker, serum Glypican-3 (GPC3) and to compare AFP in patients with HCC. One hundred and twenty-eight patients (75 patients with...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 临床试验,杂志文章

    doi:10.1002/jcla.20484

    authors: Ozkan H,Erdal H,Koçak E,Tutkak H,Karaeren Z,Yakut M,Köklü S

    更新日期:2011-01-01 00:00:00

  • Comparative study of total protein, and total and lipid-associated serum sialic acid levels in patients with type 2 diabetes mellitus.

    abstract::The aim of the present study was to investigate the serum total protein (TP), total sialic acid (TSA), lipid-associated sialic acid (LSA), LSA/TP, and LSA/TP values in type 2 diabetes mellitus (DM) patients. Two study groups (healthy controls and type 2 DM subjects) were examined. For the type 2 DM group, 120 patients...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.10078

    authors: Ekin S,Meral I,Gunduz H,Mert N

    更新日期:2003-01-01 00:00:00

  • Parameters of oxidative stress status in healthy subjects: their correlations and stability after sample collection.

    abstract::It has been proposed that sample storage may have some influence on the parameters of oxidative stress status (OSS) in biological fluids. We measured four important OSS parameters in plasma of 23 healthy subjects and repeated the measurements in the same samples kept at -70 degrees C after different time intervals. Hy...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20122

    authors: Firuzi O,Mladenka P,Riccieri V,Spadaro A,Petrucci R,Marrosu G,Saso L

    更新日期:2006-01-01 00:00:00

  • Rapid measurement of serum pancreatic amylase.

    abstract::A simple, rapid assay for the pancreatic isoenzyme of human serum amylase was developed. The assay utilized an immunoabsorbent prepared by coating latex beads with a monoclonal antibody specific for pancreatic amylase. Treatment of patient serum with immunoabsorbent removed pancreatic amylase, and measurement of resid...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860080104

    authors: Landt M,Hortin GL,Smith CH,Pashos G,Vaidya HC,Rosenblum JL

    更新日期:1994-01-01 00:00:00

  • Cost-Effective In-House Neutralization Assay for the Confirmation of HBeAg.

    abstract:BACKGROUND & AIM:Hepatitis B virus-e-antigen (HBeAg) is an affordable viral marker to assess viral replication kinetics and response to antiviral therapy. In the absence of confirmatory assays, discrepant or false-positive HBeAg results are resolved by screening for other HBV markers. We standardized an in-house HBeAg ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21995

    authors: Fletcher GJ,Anantharam R,Radhakrishnan K,Karunakaran A,Abraham P

    更新日期:2016-11-01 00:00:00

  • New method for calcium on the ADVIA analyzer is free from interference of gadolinium-type contrast agents.

    abstract::Recently, Siemens Diagnostics released a new calcium assay (CA_2) based on complex formation of calcium with Arsenazo III dye for use on the three automated, random access ADVIA Chemistry analyzers (1650, 2400, and 1200). We evaluated this method for analytical performance as well as potential interference from gadoli...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20353

    authors: Datta P,Dasgupta A

    更新日期:2009-01-01 00:00:00

  • An enzyme-linked immunosorbent assay for the detection of antitetanus toxoid antibody using aluminum-absorbed coating antigen.

    abstract::An enzyme-linked immunosorbent assay (ELISA) for the detection of antitetanus antibodies was developed using aluminum-absorbed tetanus toxoid as the coating antigen. The assay was tested by measuring antitetanus antibody levels in serum obtained from subjects before and after immunization with the aluminum-absorbed te...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860040210

    authors: Thiele GM,Rogers J,Collins M,Yasuda N,Smith D,McDonald TL

    更新日期:1990-01-01 00:00:00

  • Mass spectroscopic characteristics of low molecular weight proteins extracted from calcium oxalate stones: preliminary study.

    abstract::It is believed that boundary compositions of matrix proteins might play a role in stone formation; however, few proteomic studies concerning matrix proteins in urinary stones have been conducted. In this study, we extracted low molecular weight proteins from calcium oxalate stones and measured their characteristic pat...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20214

    authors: Chen WC,Lai CC,Tsai Y,Lin WY,Tsai FJ

    更新日期:2008-01-01 00:00:00

  • Comparison of three commonly used PCR-based techniques to analyze MSI status in sporadic colorectal cancer.

    abstract::Several retrospective studies have shown that a high level of microsatellite instability (MSI-H) is an important prognostic factor of a more favorable outcome in stage II and III colorectal cancer (CRC) patients. In this study, three commonly used polymerase chain reaction (PCR)-based MSI analysis techniques were comp...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20097

    authors: Deschoolmeester V,Baay M,Wuyts W,Van Marck E,Pelckmans P,Lardon F,Vermorken JB

    更新日期:2006-01-01 00:00:00

  • Novel rapid immunochromatographic test based on an enzyme immunoassay for detecting nucleocapsid antigen in SARS-associated coronavirus.

    abstract::A novel severe acute respiratory syndrome-associated coronavirus (SARS-CoV) has been discovered. The detection of both antigens and antibodies in SARS-CoV from human specimens with suspected SARS plays an important role in preventing infection. We developed a novel rapid immunochromatographic test (RICT) based on the ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20070

    authors: Kogaki H,Uchida Y,Fujii N,Kurano Y,Miyake K,Kido Y,Kariwa H,Takashima I,Tamashiro H,Ling AE,Okada M

    更新日期:2005-01-01 00:00:00

  • Diurnal variation of biopyrrin excretion in random urine specimens is not corrected by creatinine.

    abstract::Circulating bilirubin is thought to function as a physiological antioxidant. One of the decomposition products of this process is the biopyrrins, which include two regioisomers: biotripyrrin-a (1,14,15,17-tetrahydro-2,7,13-trimethyl-1,14-deoxy-3-vinyl-16H-tripyrrin-8,12-dipropionic acid) and biotripyrrin-b (1,14,15,17...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20157

    authors: Ihara H,Matsumoto T,Morita Y,Hirano A,Okada M,Hashizume N,Shioji I,Yoshimura H

    更新日期:2007-01-01 00:00:00

  • Microparticle-enhanced nephelometric immunoassay of human plasminogen.

    abstract::A microparticle-enhanced nephelometric immunoassay was developed for plasminogen quantitation in human plasma. It is based on the nephelometric measurement of the light scattered by microparticle clusters formed during a sandwich reaction between plasminogen, microparticle--anti-plasminogen conjugate, and the free ant...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/(SICI)1098-2825(1996)10:2<85::AID-JCLA5>3.

    authors: Marchal E,Montagne P,Cuillière ML,Béné MC,Faure G

    更新日期:1996-01-01 00:00:00

  • Comparison of the effect of gel used in two different serum separator tubes for thyroid function tests.

    abstract:BACKGROUND:Selection and verification of blood collection tubes is an important preanalytical issue in clinical laboratories. Today, gel tubes are commonly used with many advantages, although they are known to cause interference in immunoassay methods. In this study, we aimed to compare SSTs of two different suppliers ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22427

    authors: Ercan M,Fırat Oğuz E,Akbulut ED,Yilmaz M,Turhan T

    更新日期:2018-07-01 00:00:00

  • A comparison study between wide-range and high-sensitivity C-reactive protein assays (Roche Cobas c702) for low C-reactive protein concentration in patients with cardiovascular risk.

    abstract:BACKGROUND:Low concentration C-reactive protein (CRP) has favorable prognostic significance in patients with cardiovascular risks. METHODS:We compared the wr-CRP method with the hs-CRP method both on Roche Cobas c702 analyzer for the determination of low CRP concentration (<20 mg/L) including 200 patients treated in C...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22957

    authors: Li R,Xue Y,Wang T,Gong L,Peng P,Xiong P,Dai M,Shao T,Hu Y,Ye X

    更新日期:2019-10-01 00:00:00

  • Prostate-specific antigen and prostate gland volume: correlation and clinical application.

    abstract::We studied 103 patients seen in our Prostate Cancer Detection Clinic to determine whether a correlation exists between serum prostate-specific antigen (PSA) values and ultrasound-calculated prostate gland volume. Seventy men (68%) had a PSA value less than or equal to 4 ng/ml (our upper limit of normal). The men were ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860040212

    authors: Babaian RJ,Fritsche HA,Evans RB

    更新日期:1990-01-01 00:00:00

  • Performance Evaluation of a Salivary Amylase Biosensor for Stress Assessment in Military Field Research.

    abstract:BACKGROUND:A convenient biosensor for real-time measurement of biomarkers for in-field psychophysiological stress research and military operations is desirable. We evaluated a hand-held device for measuring salivary amylase as a stress marker in medical technicians undergoing combat casualty care training using two dif...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21840

    authors: Peng HT,Savage E,Vartanian O,Smith S,Rhind SG,Tenn C,Bjamason S

    更新日期:2016-05-01 00:00:00

  • Increased concentration of serum periostin is associated with poor outcome of patients with aneurysmal subarachnoid hemorrhage.

    abstract:OBJECTIVE:To explore the role of serum periostin in patients with aneurysmal subarachnoid hemorrhage (aSAH). METHOD:We conducted a retrospective study and 124 aSAH patients treated in Shenzhen People's hospital during March 1st 2015 to December 30th 2016 were included. Baseline information, neurological status and cli...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22389

    authors: Luo W,Wang H,Hu J

    更新日期:2018-06-01 00:00:00

  • Factors interfering with the accuracy of five blood glucose meters used in Chinese hospitals.

    abstract:BACKGROUND:The prevalence of diabetes is increasing in China. Glucose control is very important in diabetic patients. The aim of this study was to compare the accuracy of five glucose meters used in Chinese hospitals with a reference method, in the absence and presence of various factors that may interfere with the met...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21611

    authors: Lv H,Zhang GJ,Kang XX,Yuan H,Lv YW,Wang WW,Randall R

    更新日期:2013-09-01 00:00:00

  • Separation of adult chains of abnormal haemoglobin: Identification by reversed-phase high-performance liquid chromatography.

    abstract::Rare abnormal haemoglobin (Hb) often poses a problem in the diagnosis of relative electrophoresis mobility. The rare neutral Hbs interact with the Hb S and thus can increase the severity of sickle cell anaemia. In the present study, we investigated the use of reversed-phase high-performance liquid chromatography (RP-H...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20007

    authors: Yapo PA,Datté JY,Yapo A,Wachman H

    更新日期:2004-01-01 00:00:00

  • Differentiation of myeloperoxidase and glandular peroxidase in biological fluids: application to human saliva.

    abstract::A modification of the assay system for peroxidase activity in human mixed saliva using 2,2'-azinobis-(-ethylbenzthiazoline-6-sulphonic acid) (ABTS) as the substrate is reported. The modifications permit differentiation between glandular peroxidase (SPX) and myeloperoxidase (MPX) activity. In addition, factors endogeno...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860050111

    authors: Venezie RD,Jenzano JW,Lundblad RL

    更新日期:1991-01-01 00:00:00

  • Contribution of adiponectin polymorphisms to the risk of coronary artery disease in a North-African Tunisian population.

    abstract:BACKGROUND:Adiponectin, an adipocyte-derived protein, is known to play a key role in the processes leading to atherosclerosis and coronary artery disease (CAD) through its anti-atherogenic, anti-inflammatory, antioxidative, and anti-apoptotic properties. In the current study, we have studied the association of two sing...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22446

    authors: Ghazouani L,Elmufti A,Baaziz I,Chaabane I,Ben Mansour H

    更新日期:2018-09-01 00:00:00

  • MicroRNA-146b correlates with decreased acute respiratory distress syndrome risk, reduced disease severity, and lower 28-day mortality in sepsis patients.

    abstract:OBJECTIVE:This study aimed to investigate the predictive value of microRNA-146b (miR-146b) on acute respiratory distress syndrome (ARDS) risk, and the correlation of miR-146b with disease severity and 28-day mortality in sepsis patients. METHODS:A total of 104 sepsis patients and 100 healthy controls (HCs) were consec...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23510

    authors: Chen W,Liu L,Yang J,Wang Y

    更新日期:2020-08-26 00:00:00