New method for calcium on the ADVIA analyzer is free from interference of gadolinium-type contrast agents.

Abstract:

:Recently, Siemens Diagnostics released a new calcium assay (CA_2) based on complex formation of calcium with Arsenazo III dye for use on the three automated, random access ADVIA Chemistry analyzers (1650, 2400, and 1200). We evaluated this method for analytical performance as well as potential interference from gadolinium-containing magnetic contrast agents. With Siemens Chemistry serum and urine controls, 2-levels each, the imprecision for the new method was (n=40 each): within-run and total CV of <2.2 and <3.8%, respectively, over all three platforms. The analytical range/linearity of the method (all three systems) was 1-16 mg/dl (serum or plasma) and 1-32 mg/dl (urine). The new method on all three platforms correlated well with a reference (Inductively Coupled Plasma Atomic Emission Spectroscopy) method (n=61, range 4.03-10.30 mg/dl). The ADVIA 1650 CA_2 method also correlated well with the Roche Modular system((R)) Calcium method. The new method showed <10% interference with unconjugated or conjugated bilirubin (50 mg/dl), hemoglobin (1,000 mg/dl), lipids (1,000 mg/dl), and two magnetic resonance contrast agents containing Gadolinium (OptiMARK((R)) 1 mmol/l and Omniscan 1.5 mmol/l). On the contrary, the Roche Calcium method showed significant negative interference with gadolinium-containing contrast agents. We conclude that the ADVIA Ca_2 method can measure serum, plasma, or urine calcium concentrations accurately and is also free from interferences of gadolinium-containing agents.

journal_name

J Clin Lab Anal

authors

Datta P,Dasgupta A

doi

10.1002/jcla.20353

subject

Has Abstract

pub_date

2009-01-01 00:00:00

pages

399-403

issue

6

eissn

0887-8013

issn

1098-2825

journal_volume

23

pub_type

杂志文章
  • Increased concentration of serum periostin is associated with poor outcome of patients with aneurysmal subarachnoid hemorrhage.

    abstract:OBJECTIVE:To explore the role of serum periostin in patients with aneurysmal subarachnoid hemorrhage (aSAH). METHOD:We conducted a retrospective study and 124 aSAH patients treated in Shenzhen People's hospital during March 1st 2015 to December 30th 2016 were included. Baseline information, neurological status and cli...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22389

    authors: Luo W,Wang H,Hu J

    更新日期:2018-06-01 00:00:00

  • Prevalence of IgG autoantibody against F-actin in patients suspected of having autoimmune or acute viral hepatitis.

    abstract::Our objectives in this study were to compare results obtained by an enzyme immunoassay (EIA) for F-actin antibody (FAA) immunoglobulin G (IgG) to those determined by an indirect fluorescent antibody (IFA) assay for smooth muscle antibody (SMA) IgG, and to determine the prevalence of FAA in patient sera having serologi...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20167

    authors: Jaskowski TD,Konnick EQ,Ashwood ER,Litwin CM,Hill HR

    更新日期:2007-01-01 00:00:00

  • Microparticle-enhanced nephelometric immunoassay for human C-reactive protein.

    abstract::Polyfunctional hydrophilic microspheres of 125-nm diameter can be produced by copolymerization of acrylic monomers. Purified c-reactive protein (CRP) was covalently bound to these new micropheres, and the conjugate obtained was used as reagent in a microparticle-enhanced nephelometric immunoassay for human CRP. This a...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860060106

    authors: Montagne P,Laroche P,Cuillière ML,Varcin P,Pau B,Duheille J

    更新日期:1992-01-01 00:00:00

  • Decorin transfection in human mesangial cells downregulates genes playing a role in the progression of fibrosis.

    abstract::The proteoglycan decorin inhibits TGF-beta; therefore, it could antagonize progression of fibrotic diseases associated with activation of TGF-beta(1). The effect of decorin transfection in human mesangial cells (HMCs) on the expression of genes related to kidney fibrosis was investigated. HMCs, isolated from glomeruli...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.10038

    authors: Costacurta A,Priante G,D'Angelo A,Chieco-Bianchi L,Cantaro S

    更新日期:2002-01-01 00:00:00

  • AKIP1 expression in tumor tissue as a new biomarker for disease monitoring and prognosis in non-small cell lung cancer: Results of a retrospective study.

    abstract:BACKGROUND:A-kinase-interacting protein 1 (AKIP1) has been reported as an oncogenetic factor in multiple cancers; however, no study has reported its role in non-small cell lung cancer (NSCLC) yet. This study aimed to evaluate the expression of AKIP1, and its correlation with tumor characteristics as well as prognosis i...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23128

    authors: Liu Y,Tian J,Qin D,Liu J,Xie Y

    更新日期:2020-04-01 00:00:00

  • The importance of serum biglycan levels as a fibrosis marker in patients with chronic hepatitis B.

    abstract:BACKGROUND:Liver biopsy is recommended in the majority of patients with chronic viral hepatitis for fibrosis evaluation. Because of the potential risks of liver biopsy, many studies related to non-invasive biomarkers of hepatic fibrosis have been performed. We aimed to assess the diagnostic value of serum biglycan as a...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22109

    authors: Ciftciler R,Ozenirler S,Yucel AA,Cengiz M,Erkan G,Buyukdemirci E,Sönmez C,Esendaglı GY

    更新日期:2017-09-01 00:00:00

  • Quantitative automated latex nephelometric immunoassay for determination of myoglobin in human serum.

    abstract::We have evaluated a new latex nephelometric test for the quantitation of myoglobin in human serum. The assay consists of incubating the diluted serum sample (20-fold) for 12 min at room temperature with latex particles covalently coated with anti-myoglobin antibodies and then quantifying the change of light-scatter pr...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860050305

    authors: Borque L,Rus A,Ruiz R

    更新日期:1991-01-01 00:00:00

  • Serum pepsinogen C: a useful marker of Helicobacter pylori eradication?

    abstract::Medical treatment for Helicobacter pylori (Hp) infection is now recommended in several types of gastroduodenal disease, and its success is usually monitored by hystology. The end-points of our work were to identify the most suitable serum index of Hp eradication among pepsinogen A (PGA), pepsinogen C (PGC), PGA/PGC ra...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/(SICI)1098-2825(1996)10:1<1::AID-JCLA1>3.0

    authors: Plebani M,Basso D,Scrigner M,Toma A,Di Mario F,Dal Bò N,Samloff IM

    更新日期:1996-01-01 00:00:00

  • Association of SOX11 Polymorphisms in distal 3'UTR with Susceptibility for Schizophrenia.

    abstract:BACKGROUND:Diverse and circumstantial evidence suggests that schizophrenia is a neurodevelopmental disorder. Genes contributing to neurodevelopment may be potential candidates for schizophrenia. The human SOX11 gene is a member of the developmentally essential SOX (Sry-related HMG box) transcription factor gene family ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23306

    authors: Sun CP,Sun D,Luan ZL,Dai X,Bie X,Ming WH,Sun XW,Huo XX,Lu TL,Zhang D

    更新日期:2020-08-01 00:00:00

  • Age-dependent decreases in serum soluble interleukin-1 receptor type I (sIL-1RI) in healthy individuals: a population study of serum sIL-1RI levels in Japanese subjects.

    abstract::The levels of several soluble cytokine receptors in body fluids of healthy individuals change with age. Clinical application of the measurement of the serum soluble interleukin-1 receptor type I (sIL-1RI) level depends critically on the samples used as the controls. At present, there is no information regarding the le...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20315

    authors: Okamoto Y,Tanaka M,Miyahara N,Tanabe M,Gotoh Y,Nagai T,Fujita N,Fukui T,Masuzawa T

    更新日期:2009-01-01 00:00:00

  • Establishment of monoclonal antibody against human Apo B-48 and measurement of Apo B-48 in serum by ELISA method.

    abstract::The elevation of chylomicrons and chylomicron remnants in plasma would lead to hyperlipidemia and other complications. Apo B-48, which is translated and produced in the adult intestine from the same gene as Apo B-100, is considered to be an essential component of chylomicrons and chylomicron remnants. Using a peptide ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/(sici)1098-2825(1998)12:5<289::aid-jcla7>3

    authors: Uchida Y,Kurano Y,Ito S

    更新日期:1998-01-01 00:00:00

  • Simple strategy for sensitive detection of dopamine using CdTe QDs modified glassy carbon electrode.

    abstract:BACKGROUND:Cellular and brain metabolism of dopamine can be correlated with a number of neurodegenerative disorders, our study was to explore a simple and efficient method to detect dopamine in real samples. METHODS:A new quantum dots (CdTe QDs) could be prepared using the hydrothermal method, the electrochemical bios...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22320

    authors: Yu HW,Zhang Z,Jiang JH,Pan HZ,Chang D

    更新日期:2018-03-01 00:00:00

  • Ischemia-modified albumin in acute aortic dissection.

    abstract:BACKGROUND:Acute aortic dissection (AOD) is associated with high mortality and early diagnosis and treatment are essential. Ischemia-modified albumin (IMA) is a marker of myocardial ischemia whereas cardiac enzymes are released when myocardial necrosis occurs. We investigated, for the first time, whether IMA increases ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20418

    authors: Sbarouni E,Georgiadou P,Marathias A,Panagiotakos D,Geroulanos S,Voudris V

    更新日期:2010-01-01 00:00:00

  • Bioassay vs. immunoassay for quantification of interleukin-6 in biological fluids.

    abstract::As several possible prognostic and therapeutic applications of interleukin-6 are currently under trial, the available methods for its quantification in biological fluids should be evaluated. In this report, the 7TD1 hybridoma bioassay is compared to an enzyme immunoassay for the determination of interleukin-6 in serum...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860090404

    authors: Papadopoulos NG,Dedoussis GV,Baxevanis CN,Papamichail M

    更新日期:1995-01-01 00:00:00

  • Measurement of free and total hydroxyproline by automated flow injection of serum or urine samples from maintenance hemodialysis patients with renal osteodystrophy.

    abstract::An automated measurement of total and free hydroxyproline in serum or urine is presented that uses flow injection analysis. After exclusion of nonspecific substances, hydroxyproline was oxidized by chloramine-T and L-cysteine with Ehrlich's reagent. The linearity obtained was from 3.8 mumole/L to 1.22 mmole/L with goo...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860080504

    authors: Uji Y,Karmen A,Okabe H,Hata K,Miura M,Ozaki K,Minamizaki M,Shibata T,Inayama S

    更新日期:1994-01-01 00:00:00

  • Diagnostic and prognostic role of serum glypican 3 in patients with hepatocellular carcinoma.

    abstract::α-Feto protein (AFP) is the widely used tumor marker in the diagnosis of hepatocellular carcinoma (HCC). The aim of this study was to assess the diagnostic and prognostic validity of a novel marker, serum Glypican-3 (GPC3) and to compare AFP in patients with HCC. One hundred and twenty-eight patients (75 patients with...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 临床试验,杂志文章

    doi:10.1002/jcla.20484

    authors: Ozkan H,Erdal H,Koçak E,Tutkak H,Karaeren Z,Yakut M,Köklü S

    更新日期:2011-01-01 00:00:00

  • Continuous blood purification ameliorates clinical signs and corrects the plasma phospholipid levels of patients with multiple organ dysfunction syndromes.

    abstract:BACKGROUND:Multiple organ dysfunction syndromes (MODS) is reported as a leading cause of mortality in intensive care units. Recently, continuous blood purification (CBP) has been mostly applied for MODS treatment. Thus, the purpose of this study was to investigate the effects of CBP on plasma phospholipid level in pati...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22411

    authors: Wen W,Wang K,Jiang ZM,Zhang ZH,Zhou L

    更新日期:2018-07-01 00:00:00

  • Identical IgM antibodies recognizing a glycine-alanine epitope are induced during acute infection with Epstein-Barr virus and cytomegalovirus.

    abstract::We studied antibody production in serial serum samples from patients with acute Epstein-Barr virus (EBV) and cytomegalovirus (CMV) infections. Sera were analyzed both by enzyme-linked immunosorbent assay (ELISA) using a synthetic peptide (P62) derived from the glycine-alanine repeating region of the Epstein-Barr nucle...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860040613

    authors: Rhodes G,Smith RS,Rubin RE,Vaughan J,Horwitz CA

    更新日期:1990-01-01 00:00:00

  • Comparison of prostate acid phosphatase with acid phosphatase isoenzymes from the lung and spleen.

    abstract::Acid phosphatase was purified to electrophoretic homogeneity from human normal lung and spleen and was characterized biochemically and immunologically in comparison with prostate acid phosphatase (PAP). The apparent MW of lung acid phosphatase (LAP) and spleen acid phosphatase (SAP) was 110,000 and 100,000, respective...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860040606

    authors: Lin MF,Li SS,Chu TM,Lee CL

    更新日期:1990-01-01 00:00:00

  • Does cigarette smoking affect the diagnostic reliability of hemoglobin alpha 2 delta 2 (HbA2)?

    abstract::Quantitation of hemoglobin alpha 2 delta 2 (HbA2) is a basic and confirmatory test in diagnosing the carrier state of beta-thalassemia. The present study was designed to investigate the effect of cigarette smoking on the diagnostic reliability of HbA2. A total of 2,867 (654 smokers and 2,213 never smokers) male subjec...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20228

    authors: Tarazi IS,Sirdah MM,El Jeadi H,Al Haddad RM

    更新日期:2008-01-01 00:00:00

  • N-terminal pro-Brain natriuretic peptide as a useful biomarker for monitoring prognosis in patients with cardiac valve replacement.

    abstract:BACKGROUND:N-terminal pro-Brain natriuretic peptide (NT-proBNP) is an important biomarker to indicate cardiac function, but its significance in cardiac surgery is still unclear. OBJECTIVE:To explore clinical significance of serum NT-proBNP and their dynamic characteristics in patients with cardiac valve replacement (C...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20435

    authors: Cai B,Wang L,Liu J,Shi Y,Guo Y

    更新日期:2011-01-01 00:00:00

  • Hsa_circ_0001649 restrains gastric carcinoma growth and metastasis by downregulation of miR-20a.

    abstract:BACKGROUND:Gastric carcinoma (GC) is a familiar carcinoma and serious threat to human health. We investigated the efficacy and mechanism of circular RNA hsa_circ_0001649 on the growth, migration, and invasion of GC cells. METHODS:microRNA (miR)-20a and hsa_circ_0001649 expression was investigated by RT-qPCR and was ch...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23235

    authors: Sun H,Wang Q,Yuan G,Quan J,Dong D,Lun Y,Sun B

    更新日期:2020-06-01 00:00:00

  • A Mutagenic Primer Assay for Genotyping of the CRHR1 Gene Rare Variant rs1876828 (A/G) in Asians: A Cost-Effective SNP Typing.

    abstract:BACKGROUND:Today, the genetic and genomic research entered in a new era of high-throughput genotyping technology. However, mutagenic polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) is still a choice of genotyping method in molecular epidemiological research. It has been extensively used fo...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21832

    authors: Sharma N,Awasthi S,Phadke SR

    更新日期:2016-03-01 00:00:00

  • Evaluation of conductivity-based osmolality measurement in urine using the Sysmex UF5000.

    abstract:BACKGROUND:Automated flow cytometry-based urine analyzer is increasingly being used to identify and enumerate cells and particles in urine specimens. It measures electrical conductivity which could be transformed to osmolality. Using this machine, all urine specimens could be screened for osmolality without requiring a...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23586

    authors: Yoo DW,Lee SM,Moon SY,Kim IS,Chang CL

    更新日期:2020-09-24 00:00:00

  • High level of D-dimer predicts ischemic stroke in patients with infective endocarditis.

    abstract:BACKGROUND:Ischemic stroke is one of the most prominent and serious neurological complications of infective endocarditis (IE). Our study was designed to evaluate the predictive value of higher level of plasma D-dimer on admission for the development of ischemic stroke in patients with IE. METHODS:In this prospective s...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23206

    authors: Xu N,Fu Y,Wang S,Li S,Cai D

    更新日期:2020-05-01 00:00:00

  • An enzyme-linked immunosorbent assay for the detection of antitetanus toxoid antibody using aluminum-absorbed coating antigen.

    abstract::An enzyme-linked immunosorbent assay (ELISA) for the detection of antitetanus antibodies was developed using aluminum-absorbed tetanus toxoid as the coating antigen. The assay was tested by measuring antitetanus antibody levels in serum obtained from subjects before and after immunization with the aluminum-absorbed te...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860040210

    authors: Thiele GM,Rogers J,Collins M,Yasuda N,Smith D,McDonald TL

    更新日期:1990-01-01 00:00:00

  • Useful information provided by graphic displays of automated cell counter in hematological malignancies.

    abstract:BACKGROUND:Automated cell counters have become more and more sophisticated with passing years. The numerical and graphic data both provide useful clues for suspecting a diagnosis especially when the workload is very high. AIM:We present our experience of useful information provided by graphic displays of an automated ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22392

    authors: Gupta M,Chauhan K,Singhvi T,Kumari M,Grover RK

    更新日期:2018-06-01 00:00:00

  • Effect of temperature on lysosomal enzyme activity during preparation and storage of dried blood spots.

    abstract:BACKGROUND:The use of dried blood spots (DBS) for the assay of lysosomal enzymes has facilitated the implementation of pilot studies for newborn screening for lysosomal storage disorders in various developed countries. The aim of the study was to determine the influence of ambient temperature during DBS preparation and...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22220

    authors: Supriya M,De T,Christopher R

    更新日期:2018-01-01 00:00:00

  • A new blood collection device minimizes cellular DNA release during sample storage and shipping when compared to a standard device.

    abstract:BACKGROUND:Cell-free DNA (cfDNA) circulating in blood is currently used for noninvasive diagnostic and prognostic tests. Minimizing background DNA is vital for detection of low abundance cfDNA. We investigated whether a new blood collection device could reduce background levels of genomic DNA (gDNA) in plasma compared ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21603

    authors: Norton SE,Luna KK,Lechner JM,Qin J,Fernando MR

    更新日期:2013-07-01 00:00:00

  • A retrospective study on Escherichia coli bacteremia in immunocompromised patients: Microbiological features, clinical characteristics, and risk factors for shock and death.

    abstract:BACKGROUND:To evaluate clinical features, bacterial characteristics, and risk factors for shock and mortality of immunocompromised patients with Escherichia coli bacteremia. METHODS:A nearly 6-year retrospective study of E coli bacteremia in 188 immunocompromised patients at Xiangya Hospital was conducted. Demographic...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23319

    authors: Tao X,Wang H,Min C,Yu T,Luo Y,Li J,Hu Y,Yan Q,Liu WE,Zou M

    更新日期:2020-08-01 00:00:00