Abstract:
:Developmental nasal midline masses in children are rare lesions. Neuroimaging is essential to characterise these lesions, to determine the exact location of the lesion and most importantly to exclude a possible intracranial extension or connection. Our objective was to evaluate CT and MRI in the diagnosis of developmental nasal midline masses. Eleven patients (mean age 4.5 years) with nasal midline masses were examined by CT and MRI. Neuroimaging was evaluated for (a) lesion location/size, (b) indirect (bifid or deformed crista galli, widened foramen caecum, defect of the cribriform plate) and direct (identification of intracranially located lesion components or signal alterations) imaging signs of intracranial extension, (c) secondary complications and (d) associated malformations. Surgical and histological findings served as gold standard. Nasal dermoid sinus cysts were diagnosed in 9 patients. One patient was diagnosed with an meningocele and another patient with a nasal glioma. Indirect CT and MRI signs correlated with the surgical results in 10 of 11 patients. Direct CT findings correlated with surgery in all patients, whereas the direct MRI signs correlated in 9 of 11 patients. In 2 patients MRI showed an intracranial signal alteration not seen on CT. Neuroimaging corrected the clinical diagnosis in 1 patient. One child presented with a meningitis. In none of the patients was an associated malformation diagnosed. Intracranial extension is equally well detected by CT and MRI using indirect imaging signs. Evaluating the direct imaging signs, MRI suspected intracranial components in 2 patients without a correlate on CT. This could represent an isolated intracranial component that got undetected on CT and surgery. In 9 patients CT and MRI matched the surgical findings. The MRI did not show any false-negative results. These results in combination with the multiplanar MRI capabilities, the different image contrasts that can be generated by MRI and the lack of radiation favour the use of MRI as primary imaging tool in these young patients in which the region of imaging is usually centred on the radiosensitive eye lenses.
journal_name
Eur Radioljournal_title
European radiologyauthors
Huisman TA,Schneider JF,Kellenberger CJ,Martin-Fiori E,Willi UV,Holzmann Ddoi
10.1007/s00330-003-2008-3subject
Has Abstractpub_date
2004-02-01 00:00:00pages
243-9issue
2eissn
0938-7994issn
1432-1084journal_volume
14pub_type
杂志文章abstract::Intraventricular tumours represent a diverse group of lesions, some of them infrequent, with a wide variety of radiological features. Determination of their precise aetiology or origin can be difficult. Nevertheless, considering patient's age, location within the ventricles, and some specific radiological features, th...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300051044
更新日期:2000-01-01 00:00:00
abstract:OBJECTIVES:To evaluate the added value of deep learning (DL) analysis of the left ventricular myocardium (LVM) in resting coronary CT angiography (CCTA) over determination of coronary degree of stenosis (DS), for identification of patients with functionally significant coronary artery stenosis. METHODS:Patients who un...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5822-3
更新日期:2019-05-01 00:00:00
abstract::The aim of our study was to determine the frequency of different hepatic arterial variants identified on abdominal CT angiography (CTA) with a 64-row CT system and a high resolution protocol. A total of 250 consecutive abdominal CTAs performed on a 64-row CT system were evaluated. Two radiologists in consensus analyze...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1458-7
更新日期:2009-11-01 00:00:00
abstract:OBJECTIVE:Nearly all reported parathyroid cancers are >15 mm at presentation. The objective was to identify ultrasound criteria of malignancy in parathyroid lesions of >15 mm in size. MATERIALS AND METHODS:This study was approved by a local ethics committee. A retrospective review of patients identified from a databas...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-011-2141-3
更新日期:2011-09-01 00:00:00
abstract:OBJECTIVES:To compare a multi-feature-based radiomic biomarker with volumetric analysis in discriminating lung adenocarcinomas with different disease-specific survival on computed tomography (CT) scans. METHODS:This retrospective study obtained institutional review board approval and was Health Insurance Portability a...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-4855-3
更新日期:2017-11-01 00:00:00
abstract:OBJECTIVES:To evaluate the performance of diffusion-weighted MRI (DWI) in addition to T2-weighted (T2W) MRI for nodal restaging after chemoradiation in rectal cancer. METHODS:Thirty patients underwent chemoradiation followed by MRI (1.5 T) and surgery. Imaging consisted of T2W-MRI and DWI (b0, 500, 1000). On T2W-MRI, ...
journal_title:European radiology
pub_type: 临床试验,杂志文章
doi:10.1007/s00330-010-1937-x
更新日期:2011-02-01 00:00:00
abstract::To assess the optimal method for grading carotid artery stenosis with computed tomographic angiography (CTA), we compared visual estimation to caliper measurements, and determined inter-observer variability and agreement relative to digital subtraction angiography (DSA). We included 46 patients with symptomatic caroti...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1508-1
更新日期:2009-12-01 00:00:00
abstract::The purpose was to evaluate the accuracy of multidetector CT (MDCT) on a 16-row CT scanner in local staging of endometrial carcinoma and more specifically in the assessment of the depth of myometrial invasion and presence of cervical infiltration. This prospective study includes 21 women with newly diagnosed endometri...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-007-0839-z
更新日期:2008-05-01 00:00:00
abstract:OBJECTIVES:To compare the diagnostic accuracy of 3D versus 2D contrast-enhanced vessel-wall (CE-VW) MRI of extracranial and intracranial arteries in the diagnosis of GCA. METHODS:This prospective two-center study was approved by a national research ethics board and enrolled participants from December 2014 to October 2...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06536-7
更新日期:2020-04-01 00:00:00
abstract:OBJECTIVE:To evaluate the feasibility of dual-energy CT (DECT) ventilation imaging in combination with DE perfusion mapping for a comprehensive assessment of ventilation, perfusion, morphology and structure of the pulmonary parenchyma. METHODS:Two dual-energy CT acquisitions for xenon-enhanced ventilation and iodine-e...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-010-1866-8
更新日期:2010-12-01 00:00:00
abstract:OBJECTIVE:To investigate the value of pre-treatment amide proton transfer-weighted (APTw) imaging for predicting survival of patients with nasopharyngeal carcinoma (NPC). MATERIALS AND METHODS:Pre-treatment APTw imaging was performed in 77 NPC patients and the mean, 90th percentile, skewness, and kurtosis of APT asymm...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-06985-5
更新日期:2020-11-01 00:00:00
abstract::How contrast medium-induced nephropathy (CIN) comes about is not fully understood, although CIN constitutes a leading cause of renal failure. Here, a short review of clinical trials and a more thorough outline of mechanisms thought to cause CIN are outlined. Osmolality is only one of several physicochemical properties...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s10406-005-0113-x
更新日期:2005-11-01 00:00:00
abstract:OBJECTIVE:To investigate the detectability of pulmonary nodules in chest tomosynthesis at reduced radiation dose levels. METHODS:Eighty-six patients were included in the study and were examined with tomosynthesis and computed tomography (CT). Artificial noise was added to simulate that the tomosynthesis images were ac...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3182-1
更新日期:2014-07-01 00:00:00
abstract:OBJECTIVES:To evaluate post-ablation MRI for the detection of incompletely treated spinal osseous metastases (SOM) after cryoablation and to propose a post-ablation imaging classification. METHODS:After IRB consent, all patients treated with cryoablation of SOM between 2011 and 2017 having at least 1-year minimum foll...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06040-y
更新日期:2019-10-01 00:00:00
abstract:OBJECTIVES:To compare the value of functional future liver remnant (functFLR) to established clinical and imaging variables in prediction of post-hepatectomy liver failure (PHLF) after major liver resection. METHODS:This retrospective, cross-sectional study included 62 patients, who underwent gadoxetic acid enhanced M...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5487-y
更新日期:2018-11-01 00:00:00
abstract:OBJECTIVES:To assess whether contralateral parenchymal enhancement reproduces as an independent biomarker for patient survival in an independent patient cohort from a different cancer institution. METHODS:This is a HIPAA-compliant IRB approved retrospective study. Patients with ER-positive/HER2-negative operable invas...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5470-7
更新日期:2018-11-01 00:00:00
abstract:OBJECTIVE:The complexity of anatomical structure within the breast represents the ultimate limit to signal detection on a mammogram. To increase lesion conspicuity Digital Breast Tomosynthesis (DBT) has been recently proposed and several manufacturers are currently performing clinical trials. In this study we investiga...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-010-2041-y
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:Hypersensitivity pneumonitis (HP) has a variable clinical course. Modelling of quantitative CALIPER-derived CT data can identify distinct disease phenotypes. Mortality prediction using CALIPER analysis was compared to the interstitial lung disease gender, age, physiology (ILD-GAP) outcome model. METHODS:CAL...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4697-4
更新日期:2017-09-01 00:00:00
abstract::Nonvariceal upper gastrointestinal bleeding (NUGB) remains a major medical problem even after advances in medical therapy with gastric acid suppression and cyclooxygenase (COX-2) inhibitors. Although the incidence of upper gastrointestinal bleeding presenting to the emergency room has slightly decreased, similar decre...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-006-0477-x
更新日期:2007-07-01 00:00:00
abstract:OBJECTIVES:To determine whether there is a difference in frequency and clinical relevance of incidental findings detected by total-body computed tomography scanning (TBCT) compared to those by the standard work-up (STWU) with selective computed tomography (CT) scanning. METHODS:Trauma patients from five trauma centres...
journal_title:European radiology
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1007/s00330-016-4598-6
更新日期:2017-06-01 00:00:00
abstract::The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, ple...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-006-0562-1
更新日期:2007-08-01 00:00:00
abstract:OBJECTIVES:To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition. METHODS:78 patients (58% male, 61.5±9.1 years) were prospectively enrolled. Subjects underwent clinical 120kVp high-pitc...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-5249-2
更新日期:2018-07-01 00:00:00
abstract:AIM:To evaluate the accuracy of a T2-weighted (T2w) - and a parallel transmit zoomed b = 2000 s/mm2 (b2000) - diffusion-weighted imaging sequence among three readers with different degrees of experience for prostate cancer (Pca) detection. METHODS:Ninety-three patients with suspected Pca were enrolled. For b2000 a two...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-5004-8
更新日期:2018-02-01 00:00:00
abstract::Metastases of the spine occur in the spinal cord, dura extramedullary, epidural space, and vertebral bodies. Imaging modalities can be used to evaluate patient symptoms, screen and detect lesions, assess localization and the compartments involved (extradural, epidural, subdural, and paraspinal), and suggest therapeuti...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-004-2627-3
更新日期:2005-03-01 00:00:00
abstract:OBJECTIVE:To compare the diagnostic performance of models based on a combination of contrast-enhanced (CE) magnetic resonance imaging (MRI) with diffusion-weighted imaging (DWI) or time-intensity curves (TIC) in diagnosing malignancies of breast lesions. METHODS:A double-blind retrospective study was conducted in 328 ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-06883-w
更新日期:2020-09-01 00:00:00
abstract:OBJECTIVES:This study was conducted in order to establish the joint Society of Abdominal Radiology (SAR) and European Society of Urogenital Radiology (ESUR) guidelines on placenta accreta spectrum (PAS) disorders and propose strategies to standardize image acquisition, interpretation, and reporting for this condition w...
journal_title:European radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00330-019-06617-7
更新日期:2020-05-01 00:00:00
abstract::The original version of this article, published on 07 January 2019, unfortunately contained a mistake. ...
journal_title:European radiology
pub_type: 已发布勘误
doi:10.1007/s00330-019-06044-8
更新日期:2019-06-01 00:00:00
abstract::Iodinated X-ray contrast media are among the most frequently used pharmaceuticals for intravascular administration. Although the newer low osmolality, nonionic contrast media, are generally well tolerated, it is well known that they, like the ionic contrast media, give rise to immediate or delayed adverse reactions in...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300000543
更新日期:2000-01-01 00:00:00
abstract:OBJECTIVES:Recurrent peripheral vestibulopathy (RPV) is a public health problem, yet the aetiology remains unclear. Recent developments in MRI of endolymphatic hydrops (EH) allow for a better understanding of inner ear disorders. We intended to study the prevalence of EH in patients with RPV, in comparison to those wit...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3712-5
更新日期:2015-10-01 00:00:00
abstract:OBJECTIVES:To describe a randomized controlled trial (RCT) of digital breast tomosynthesis including synthesized two-dimensional mammograms (DBT) versus digital mammography (DM) in a population-based screening program for breast cancer and to compare selected secondary screening outcomes for the two techniques. METHOD...
journal_title:European radiology
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1007/s00330-018-5690-x
更新日期:2019-03-01 00:00:00