Abstract:
OBJECTIVE:The complexity of anatomical structure within the breast represents the ultimate limit to signal detection on a mammogram. To increase lesion conspicuity Digital Breast Tomosynthesis (DBT) has been recently proposed and several manufacturers are currently performing clinical trials. In this study we investigate the potential of DBT with variable dose distribution by using a phantom in which details of interest are within a heterogeneous background. METHODS:To compare the performance of a commercial digital mammography unit and a DBT prototype, 2D and 3D images of the breast phantom were obtained at similar dose levels. RESULTS:As expected, DBT showed superior performance over digital mammography. Although certain details of interest are not detectable with digital mammography, DBT can reveal their signal by reducing the complexity of tissue structures. Additionally, the potential of the central projection in variable dose DBT is similar to the standard projection obtained with digital mammography. Finally, the uniform and variable dose approaches provided almost identical reconstructed slices. CONCLUSION:This preliminary investigation demonstrates that breast tomosynthesis acquired with variable dose distribution exhibits inherent 3D reconstruction advantages for structure noise removal and provides a 2D projection with a physical image quality close to that of standard mammography.
journal_name
Eur Radioljournal_title
European radiologyauthors
Vecchio S,Albanese A,Vignoli P,Taibi Adoi
10.1007/s00330-010-2041-ysubject
Has Abstractpub_date
2011-06-01 00:00:00pages
1207-13issue
6eissn
0938-7994issn
1432-1084journal_volume
21pub_type
杂志文章abstract:OBJECTIVE:To estimate thyroid doses and cancer risk for paediatric patients undergoing neck computed tomography (CT). METHODS:We used average CTDI(vol) (mGy) values from 75 paediatric neck CT examinations to estimate thyroid dose in a mathematical anthropomorphic phantom (ImPACT Patient CT Dosimetry Calculator). Patie...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3590-x
更新日期:2015-07-01 00:00:00
abstract::To assess the practical feasibility and effectiveness of real-time magnetic resonance (MR) temperature monitoring for the radiofrequency (RF) ablation of liver tumours in a clinical setting, nine patients (aged 49-87 years, five men and four women) with one malignant tumour (14-50 mm, eight hepatocellular carcinomas a...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1532-1
更新日期:2010-01-01 00:00:00
abstract::Though long considered unlikely because of the resonance pattern of agents such as SonoVue, high frequency applications for small parts and intracavitary applications now seem very promising. Excellent non-linear signals can be obtained at 7 MHz and higher using recently developed CPS software, and preliminary results...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s10406-004-0084-3
更新日期:2004-10-01 00:00:00
abstract::Stress fractures are common injuries frequently overlooked on first radiographs, especially in the early course. The gold standard for accurate diagnosis is MRI and scintigraphy. We report six cases of stress fractures of the lower limb diagnosed with sonography and describe typical sonographic features. ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-004-2525-8
更新日期:2005-02-01 00:00:00
abstract::Meningeal hemangiopericytoma (MHP) is extremely rare in childhood. Mean age at diagnosis is between 38 and 43 years. We present an 8-year-old boy with MHP of the middle cranial fossa. Imaging findings were indistinguishable from an aggressive bone tumor such as Ewing's sarcoma. Imaging findings are presented and discu...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003309900222
更新日期:2000-01-01 00:00:00
abstract::Primary and metastatic tumors of the liver can be treated successfully with transcatheter chemoembolization (TACE) during selective arterial catheterism. Arteritis is a possible referred side effect which can lead to tortuosity of the arteries, stenosis and occlusion of vessels. In our hospitals 117 consecutive patien...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050159
更新日期:1997-01-01 00:00:00
abstract::The purpose of this study was to assess diaphragmatic length and shortening during the breathing cycle in healthy volunteers and patients with a lung tumor using dynamic MRI (dMRI). In 15 healthy volunteers and 28 patients with a solitary lung tumor, diaphragmatic motion and length were measured during the breathing c...
journal_title:European radiology
pub_type: 临床试验,杂志文章
doi:10.1007/s00330-004-2336-y
更新日期:2004-08-01 00:00:00
abstract::We present a case of swelling of the eyelid and supraorbital anesthesia caused by an intraorbital tumor. The differential diagnosis based on imaging consisted of aneurysmal bone cyst, schwannoma, neurofibroma, dermoid cyst, and cavernous hemangioma. The surgical and pathological diagnosis was an ancient schwannoma of ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1659-0
更新日期:2010-09-01 00:00:00
abstract:OBJECTIVES:Complications following colorectal cancer resection are common. The degree of aortic calcification (AC) on CT has been proposed as a predictor of complications, particularly anastomotic leak. This study assessed the relationship between AC and complications in patients undergoing colorectal cancer resection....
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07189-7
更新日期:2020-11-17 00:00:00
abstract::We aimed to determine the mean hepatic artery resistance index (RI) in presinusoidal portal hypertension and to compare the values with those in sinusoidal portal hypertension. The hepatic artery RIs of 11 patients with presinusoidal portal hypertension, 12 patients with sinusoidal portal hypertension and 16 healthy s...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050806
更新日期:1999-01-01 00:00:00
abstract::Mammography is a branch of radiology which could benefit greatly from the assimilation of digital imaging technologies. Computerized enhancement techniques could be used to ensure optimum presentation of all clinical images. Beyond this it will facilitate powerful new clinical resources such as computer-assisted diagn...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300050228
更新日期:1997-01-01 00:00:00
abstract::There is yet no consensus on the application of functional imaging and qualitative image interpretation in the management of gastric cancer. In this second part, we will discuss the role of image-derived quantitative parameters from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and 18F-fluorodeoxygluc...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-019-06370-x
更新日期:2020-01-01 00:00:00
abstract:OBJECTIVES:Time-resolved contrast-enhanced MR angiography (4D-MRA), which allows the simultaneous visualization of the vasculature and blood-flow dynamics, is widely used in clinical routine. In this study, the impact of two different contrast agent injection methods on 4D-MRA was examined in a controlled, standardized...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-5178-0
更新日期:2018-05-01 00:00:00
abstract::Acute liver failure (ALF)-related encephalopathy was previously characterized by MR spectroscopy of single voxels containing both grey and white matter brain tissue. Quantitative multivoxel MRS was used here to compare grey and white matter brain tissue concentrations of glutamate/glutamine (Glx) and lactate in ALF an...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-008-1049-z
更新日期:2008-11-01 00:00:00
abstract::Lesion area measurement in multiple sclerosis (MS) is one of the key points in evaluating the natural history and in monitoring the efficacy of treatments. This study was performed to check the intra- and inter-observer agreement variability of a locally developed Growing Region Segmentation Software (GRES), comparing...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300100978
更新日期:2002-04-01 00:00:00
abstract::In the evaluation of ischemic heart disease only MR imaging seems to have the potential to assess myocardial perfusion, function, and coronary morphology on a single instrument. The aim of this study was to assess the feasibility of a stress test with dipyridamole (0. 56 mg/kg) to analyze myocardial perfusion by Gd fi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050238
更新日期:1997-01-01 00:00:00
abstract::The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were the...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-003-2206-z
更新日期:2004-05-01 00:00:00
abstract:OBJECTIVE:This study aims to establish and validate a radiomics nomogram based on contrast-enhanced spectral mammography (CESM) for prediction of axillary lymph node (ALN) metastasis in breast cancer. METHODS:This retrospective study included 394 patients with breast cancer who underwent CESM examination in two hospit...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07016-z
更新日期:2020-12-01 00:00:00
abstract::Almost 15 years after its introduction, endosonography or endoscopic ultrasonography is an important technique in a wide range of gastrointestinal diseases. Other imaging techniques are CT, MRI and barium examination. There is a general consensus that the most important prognostic factor in gastric and colorectal carc...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/BF00181129
更新日期:1996-01-01 00:00:00
abstract::Magnetic resonance angiography (MRA) has become an imaging modality which comprises various techniques based on two concepts: methods relying on the natural flow effects, the time-of-flight and phase-contrast technique, either in two- or three-dimensional acquisition mode, and the more recently developed contrast-enha...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300050834
更新日期:1999-01-01 00:00:00
abstract::The original version of this article, published on 19 August 2016, unfortunately contained a mistake. ...
journal_title:European radiology
pub_type: 已发布勘误
doi:10.1007/s00330-020-06947-x
更新日期:2020-11-01 00:00:00
abstract:OBJECTIVE:To compare the performance of synthetic mammography (SM) and digital mammography (DM) with digital breast tomosynthesis (DBT) or alone for the evaluation of microcalcifications. METHODS:This retrospective study includes 198 mammography cases, all with DM, SM, and DBT images, from January to October 2013. Thr...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5585-x
更新日期:2019-01-01 00:00:00
abstract::Management of trauma patients relies on a simple but obvious concept: Time is life! This is a challenge to the emergency radiologist in his evaluation of the radiological admission survey of severe trauma patients, since the latter need a quick and thorough survey of craniocerebral, cervical, thoracic, abdominal, and ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1385-3
更新日期:2002-05-01 00:00:00
abstract::The CT and MR appearance of giant cavernous hemangiomas can be confusing, and some atypical radiographic findings have been described. We report the CT and MR features of a giant cavernous hemangioma of the liver with atypical presentation. CT showed a large hypodense geographical lesion involving the majority of the ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/BF00182465
更新日期:1996-01-01 00:00:00
abstract::The original version of this article, published on 07 January 2019, unfortunately contained a mistake. ...
journal_title:European radiology
pub_type: 已发布勘误
doi:10.1007/s00330-019-06044-8
更新日期:2019-06-01 00:00:00
abstract::The aim of this study was to evaluate ultrasound (US)-guided core-needle testicular biopsy. Twelve biopsies were performed in eleven patients, under US guidance using disposable 16- or 18-gauge needles, between April 2003 and October 2006. Details were entered on a database and records reviewed 9 months to 3 years aft...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-008-1072-0
更新日期:2008-12-01 00:00:00
abstract::The RETAIN project (Radiological Examinations Transfer on an ATM Integrated Network) has aimed at testing videoconferencing and DICOM image transfers to get advice about difficult radiological cases over an asynchronous transfer mode (ATM)-based network, which affords a more comfortable interface than narrow-band netw...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050029
更新日期:2000-01-01 00:00:00
abstract:OBJECTIVES:To evaluate the feasibility of myocardial blood flow (MBF) by computed tomography from dynamic CT perfusion (CTP) for detecting myocardial ischemia and infarction assessed by cardiac magnetic resonance (CMR) or single-photon emission computed tomography (SPECT). METHODS:Fifty-three patients who underwent st...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4238-1
更新日期:2016-11-01 00:00:00
abstract::Lymphoma is a spectrum of malignant neoplasms of the lymphoid system. The appearances radiologically are diverse with almost all organs susceptible to involvement. The condition is challenging as it can mimic the appearance of almost all other neoplasms. This review highlights in a general way the diversity of the rad...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-002-1632-7
更新日期:2003-05-01 00:00:00
abstract:OBJECTIVES:To evaluate the accuracy of diagnoses of COVID-19 based on chest CT as well as inter-observer agreement between teleradiologists during on-call duty and senior radiologists in suspected COVID-19 patients. MATERIALS AND METHODS:From March 13, 2020, to April 14, 2020, consecutive suspected COVID-19 adult pati...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07345-z
更新日期:2020-10-29 00:00:00