MR angiography: supra-aortic vessels.

Abstract:

:Magnetic resonance angiography (MRA) has become an imaging modality which comprises various techniques based on two concepts: methods relying on the natural flow effects, the time-of-flight and phase-contrast technique, either in two- or three-dimensional acquisition mode, and the more recently developed contrast-enhanced (CE) MRA methods. The main indications for evaluation of the supra-aortic vessels are, firstly, the grading of carotid artery stenoses caused by an atherosclerotic process, and secondly, the evaluation of dissections of the cervical arteries because this disease plays an important role as a cause for stroke especially in younger patients. The various MRA techniques in their application to the main pathologies encountered at the supra-aortic vessels are presented, and recent developments in the promising field of CE MRA are discussed.

journal_name

Eur Radiol

journal_title

European radiology

authors

Wetzel S,Bongartz G

doi

10.1007/s003300050834

subject

Has Abstract

pub_date

1999-01-01 00:00:00

pages

1277-84

issue

7

eissn

0938-7994

issn

1432-1084

pii

90091277.330

journal_volume

9

pub_type

杂志文章,评审
  • Integrative nomogram of CT imaging, clinical, and hematological features for survival prediction of patients with locally advanced non-small cell lung cancer.

    abstract:OBJECTIVES:To determine the integrative value of clinical, hematological, and computed tomography (CT) radiomic features in survival prediction for locally advanced non-small cell lung cancer (LA-NSCLC) patients. METHODS:Radiomic features and clinical and hematological features of 118 LA-NSCLC cases were firstly extra...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5949-2

    authors: Wang L,Dong T,Xin B,Xu C,Guo M,Zhang H,Feng D,Wang X,Yu J

    更新日期:2019-06-01 00:00:00

  • Semi-automated volumetric analysis of lymph node metastases during follow-up--initial results.

    abstract:OBJECTIVE:Quantification of tumour burden in oncology requires accurate and reproducible evaluation. The current standard is RECIST measurement with its inherent disadvantages. Volumetric analysis is an alternative for therapy monitoring. The aim of this study was to evaluate the feasibility of volumetric analysis of l...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1966-5

    authors: Fabel M,Bolte H,von Tengg-Kobligk H,Bornemann L,Dicken V,Delorme S,Kauczor HU,Heller M,Biederer J

    更新日期:2011-04-01 00:00:00

  • Reference ranges of left ventricular structure and function assessed by contrast-enhanced cardiac MR and changes related to ageing and hypertension in a population-based study.

    abstract:OBJECTIVES:Reference ranges of left ventricular (LV) parameters from cardiac magnetic resonance (CMR) were established to investigate the impact of ageing and hypertension as important determinants of cardiac structure and function. METHODS:One thousand five hundred twenty-five contrast-enhanced CMRs were conducted in...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5345-y

    authors: Bülow R,Ittermann T,Dörr M,Poesch A,Langner S,Völzke H,Hosten N,Dewey M

    更新日期:2018-09-01 00:00:00

  • Early post-operative magnetic resonance imaging in glioblastoma: correlation among radiological findings and overall survival in 60 patients.

    abstract:OBJECTIVES:To evaluate early post-operative magnetic resonance (EPMR) as a prognostic tool after resection of glioblastoma. METHODS:Sixty EPMR examinations were evaluated for perioperative infarct, tumour growth between diagnosis and EPMR, contrast enhancement pattern, and extent of resection (EOR). The EOR was approa...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3914-x

    authors: Majós C,Cos M,Castañer S,Gil M,Plans G,Lucas A,Bruna J,Aguilera C

    更新日期:2016-04-01 00:00:00

  • Efficacy of contrast-enhanced FDG PET/CT in patients awaiting liver transplantation with rising alpha-fetoprotein after bridge therapy of hepatocellular carcinoma.

    abstract:OBJECTIVE:To assess the diagnostic accuracy and illustrate positive findings of contrast-enhanced fluorine-18 fluoro-D-glucose positron emission tomography/computed tomography (18F-FDG PET/CT) image in patients awaiting liver transplantation (LT) with rising alpha-fetoprotein (AFP) after bridge therapy of hepatocellula...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-018-5425-z

    authors: Refaat R,Basha MAA,Hassan MS,Hussein RS,El Sammak AA,El Sammak DAEA,Radwan MHS,Awad NM,Saad El-Din SA,Elkholy E,Ibrahim DRD,Saleh SA,Montasser IF,Said H

    更新日期:2018-12-01 00:00:00

  • Quantification of bronchial dimensions at MDCT using dedicated software.

    abstract::This study aimed to assess the feasibility of quantification of bronchial dimensions at MDCT using dedicated software (BronCare). We evaluated the reliability of the software to segment the airways and defined criteria ensuring accurate measurements. BronCare was applied on two successive examinations in 10 mild asthm...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0496-7

    authors: Brillet PY,Fetita CI,Beigelman-Aubry C,Saragaglia A,Perchet D,Preteux F,Grenier PA

    更新日期:2007-06-01 00:00:00

  • Evaluation of hepatocellular carcinoma using SonoVue, a second generation ultrasound contrast agent: correlation with cellular differentiation.

    abstract::The appearance of hepatocellular carcinoma (HCC) with contrast-enhanced ultrasound (CEUS) in the vascular phase is described and evaluated as to whether the enhancement pattern correlates with the degree of cellular differentiation. One hundred four HCCs were prospectively evaluated with CEUS using coherent-contrast i...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2298-0

    authors: Nicolau C,Catalá V,Vilana R,Gilabert R,Bianchi L,Solé M,Pagés M,Brú C

    更新日期:2004-06-01 00:00:00

  • 2D SPLASH: a new method to determine the fatty infiltration of the rotator cuff muscles.

    abstract::The objective of this paper is to quantify the fatty degeneration (infiltration) of rotator cuff muscles with a new spectroscopic FLASH (SPLASH) sequence. Before planned surgery (reconstruction or muscle transfer), 20 patients (13 men, 7 women; 35-75 years) with different stages of rotator cuff disease underwent an MR...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2410-5

    authors: Kenn W,Böhm D,Gohlke F,Hümmer C,Köstler H,Hahn D

    更新日期:2004-12-01 00:00:00

  • Metastatic disease of the spine.

    abstract::Metastases of the spine occur in the spinal cord, dura extramedullary, epidural space, and vertebral bodies. Imaging modalities can be used to evaluate patient symptoms, screen and detect lesions, assess localization and the compartments involved (extradural, epidural, subdural, and paraspinal), and suggest therapeuti...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2627-3

    authors: Andreula C,Murrone M

    更新日期:2005-03-01 00:00:00

  • 3D-black-blood 3T-MRI for the diagnosis of thoracic large vessel vasculitis: A feasibility study.

    abstract:OBJECTIVES:To evaluate the feasibility of T1w-3D black-blood turbo spin echo (TSE) sequence with variable flip angles for the diagnosis of thoracic large vessel vasculitis (LVV). METHODS:Thirty-five patients with LVV, diagnosed according to the current standard of reference, and 35 controls were imaged at 3.0T using 1...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4525-x

    authors: Treitl KM,Maurus S,Sommer NN,Kooijman-Kurfuerst H,Coppenrath E,Treitl M,Czihal M,Hoffmann U,Dechant C,Schulze-Koops H,Saam T

    更新日期:2017-05-01 00:00:00

  • Forensic age assessment of the knee: proposal of a new classification system using two-dimensional ultrasound volumes and comparison to MRI.

    abstract:OBJECTIVES:To assess epiphyseal growth plate closure of the knee for forensic age estimation using an ultrasound (US)-based method and to compare the findings with MRI. METHODS:Thirty-three healthy male individuals (age, 14.4-19.3 years) were prospectively evaluated for epiphyseal growth plate closure of the right kne...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07343-1

    authors: Herrmann J,Säring D,Auf der Mauer M,Groth M,Jopp-van Well E

    更新日期:2020-10-14 00:00:00

  • Acute mesenteric ischemia caused by spontaneous isolated dissection of the superior mesenteric artery: treatment by percutaneous stent placement.

    abstract::Spontaneous and isolated dissection of the superior mesenteric artery is a rare and often fatal event which has been successfully treated by surgery in several reported cases. We present a patient with acute mesenteric ischemia due to superior mesenteric artery dissection who was successfully treated by percutaneous e...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000520

    authors: Leung DA,Schneider E,Kubik-Huch R,Marincek B,Pfammatter T

    更新日期:2000-01-01 00:00:00

  • Protective effect against repeat adverse reactions to iodinated contrast medium: Premedication vs. changing the contrast medium.

    abstract:OBJECTIVES:The purpose of this study was to assess the protective effect of premedication and changing contrast media (CM) against repeat adverse reactions (ARs) to iodinated CM. METHODS:Between January 2006 and September 2014, 771 cases with previous ARs to CM were administered CM. The same CM that had caused ARs pre...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4028-1

    authors: Abe S,Fukuda H,Tobe K,Ibukuro K

    更新日期:2016-07-01 00:00:00

  • Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: technical background, basic image quality parameters, and review of the literature.

    abstract::The two most frequently performed diagnostic X-ray examinations are those of the extremities and of the chest. Thus, dose reduction in the field of conventional skeletal and chest radiography is an important issue and there is a need to reduce man-made ionizing radiation. The large-area flat-panel detector based on am...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2243-2

    authors: Völk M,Hamer OW,Feuerbach S,Strotzer M

    更新日期:2004-05-01 00:00:00

  • The delayed effects of irreversible electroporation ablation on nerves.

    abstract:OBJECTIVE:To evaluate the delayed effects of irreversible electroporation (IRE) ablation on nerves. METHODS:The study was approved by the institutional animal care and use committee. CT-guided IRE-ablation (electric field per distance, 1,500 V/cm; pulse length, 70 μs; number of pulses, 90) of 6 sciatic nerves was perf...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2610-3

    authors: Schoellnast H,Monette S,Ezell PC,Maybody M,Erinjeri JP,Stubblefield MD,Single G,Solomon SB

    更新日期:2013-02-01 00:00:00

  • Quantitating aortic regurgitation by cardiovascular magnetic resonance: significant variations due to slice location and breath holding.

    abstract:OBJECTIVES:Compare variability in flow measurements by phase contrast MRI, performed at different locations in the aorta and pulmonary artery (PA) using breath-held (BH) and free-breathing (FB) sequences. METHODS:Fifty-seven patients with valvular heart disease, confirmed by echocardiography, were scanned using BH tec...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4120-6

    authors: Chaturvedi A,Hamilton-Craig C,Cawley PJ,Mitsumori LM,Otto CM,Maki JH

    更新日期:2016-09-01 00:00:00

  • CT-guided core-needle biopsy in the diagnosis of mediastinal lymphoma.

    abstract::The advent of radiologic guidance techniques for percutaneous biopsy has changed the approach to the routine diagnosis of mediastinal lymphoma. The aim of the present study was to evaluate the diagnostic accuracy of CT-guided percutaneous core-needle biopsy (PCNB) in the clinical management of patients with mediastina...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050991

    authors: Sklair-Levy M,Polliack A,Shaham D,Applbaum YH,Gillis S,Ben-Yehuda D,Sherman Y,Libson E

    更新日期:2000-01-01 00:00:00

  • Dorsal defect on a multi-partite patella: imaging findings.

    abstract::Coincidence of dorsal defect on a multipartite patella constitutes a rare cause of anterior knee pain in the first decades of life. Imaging findings of this uncommon symptomatic skeletal variant are discussed, with emphasis on MR features. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000724

    authors: Mellado JM,Salvadó E,Ramos A,Camins A,Saurí A

    更新日期:2001-01-01 00:00:00

  • Imaging of hamstring injuries: therapeutic implications.

    abstract::Though recent research into the diagnosis and management of hamstring disorders has resulted in early and accurate recognition of injury, hamstring strain remains the most common form of muscle injury in the active population. With prompt recognition of hamstring strain, an appropriate rest and rehabilitation routine ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-005-0075-3

    authors: Koulouris G,Connell D

    更新日期:2006-07-01 00:00:00

  • Late gadolinium enhancement cardiac imaging on a 3T scanner with parallel RF transmission technique: prospective comparison of 3D-PSIR and 3D-IR.

    abstract:OBJECTIVE:To qualitatively and quantitatively compare different late gadolinium enhancement (LGE) sequences acquired at 3T with a parallel RF transmission technique. METHODS:One hundred and sixty participants prospectively enrolled underwent a 3T cardiac MRI with 3 different LGE sequences: 3D Phase-Sensitive Inversion...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4002-y

    authors: Schultz A,Caspar T,Schaeffer M,Labani A,Jeung MY,El Ghannudi S,Roy C,Ohana M

    更新日期:2016-06-01 00:00:00

  • Hemolytic effect of deformed intra-arterial stents and stent grafts in vitro.

    abstract::Our objective was to evaluate the hemolytic effect of stents and stent grafts in an in vitro flow model. The model consisted of silicone tubings. Pulsatile flow was delivered at 1170 ml/min. Diluted packed erythrocytes were used (hematocrit of 33%). The Palmaz, MegaLink stents or Passager, Hemobahn stent grafts were p...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1664-z

    authors: Grimm J,Brunn H,Heller M,Mueller-Huelsbeck S

    更新日期:2003-06-01 00:00:00

  • The use of ECG and respiratory triggering to improve the sensitivity of oxygen-enhanced proton MRI of lung ventilation.

    abstract::Changes in lung signal between normal breathing and breathing pure oxygen is the basis for oxygen-enhanced ventilation MRI. An optimal technique guarantees a significant response to pure oxygen in well-ventilated lung tissue. To improve the sensitivity, we investigated the effect of ECG and respiratory triggering. Cen...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1694-6

    authors: Vaninbroukx J,Bosmans H,Sunaert S,Demedts M,Delcroix M,Marchal G,Verschakelen J

    更新日期:2003-06-01 00:00:00

  • Practical applications of deep learning: classifying the most common categories of plain radiographs in a PACS using a neural network.

    abstract:OBJECTIVES:The goal of the present study was to classify the most common types of plain radiographs using a neural network and to validate the network's performance on internal and external data. Such a network could help improve various radiological workflows. METHODS:All radiographs from the year 2017 (n = 71,274) a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07241-6

    authors: Dratsch T,Korenkov M,Zopfs D,Brodehl S,Baessler B,Giese D,Brinkmann S,Maintz D,Pinto Dos Santos D

    更新日期:2020-09-28 00:00:00

  • Radiological research in Europe: a bibliometric study.

    abstract::We performed a bibliometric search to evaluate number and scientific "weight" of papers written by European radiologists, as compared with colleagues from other countries, to measure the contribution of European researchers to radiology journals, and to correlate bibliometric parameters with some socio-economic factor...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1640-7

    authors: Mela GS,Martinoli C,Poggi E,Derchi LE

    更新日期:2003-04-01 00:00:00

  • Cell tracking using (19)F magnetic resonance imaging: technical aspects and challenges towards clinical applications.

    abstract::(19)F MRI is emerging as a new imaging technique for cell tracking. It is particularly attractive because of its potential for direct and precise cell quantification. The most important challenge towards in vivo applications is the sensitivity of the technique, i.e. the detection limit in a reasonable imaging time. Op...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3474-5

    authors: Amiri H,Srinivas M,Veltien A,van Uden MJ,de Vries IJ,Heerschap A

    更新日期:2015-03-01 00:00:00

  • Breast MR biopsy: Pathological and radiological correlation.

    abstract:PURPOSE:To identify pathological features for sample analysis of magnetic resonance imaging-guided vaccum-assisted breast biopsy (MRIgVaBB) to optimize radio pathological correlation and identify discordant benign result. MATERIAL AND METHODS:Databases of two centres were queried to identify MRIgVaBB performed between...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-015-4071-y

    authors: Dratwa C,Jalaguier-Coudray A,Thomassin-Piana J,Gonin J,Chopier J,Antoine M,Trop I,Darai E,Thomassin-Naggara I

    更新日期:2016-08-01 00:00:00

  • Dose and image quality in the comparison of analogue and digital techniques in paediatric urology examinations.

    abstract::In paediatric radiology it has been recognised that children have a higher risk of developing cancer from the irradiation than adults (two to three times); therefore, increased attention has been directed towards the dose to the patient. In this study the effect on patient dose and image quality in replacing the expos...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-003-2144-9

    authors: Persliden J,Helmrot E,Hjort P,Resjö M

    更新日期:2004-04-01 00:00:00

  • Congenital absence of the internal carotid artery and the basilar artery with persistent trigeminal artery associated with coarctation of the aorta.

    abstract::We report a case of congenital absence of the cervical and petrous part of the left internal carotid artery, the middle and proximal part of the basilar artery, and the V4 segment of the left vertebral artery associated with a left persistent trigeminal artery and a coarctation of the aorta. The left cerebral vessels ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000500

    authors: Jaeger HJ,Mehring UM,Gissler HM,Mathias KD

    更新日期:2000-01-01 00:00:00

  • Intravoxel water diffusion heterogeneity MR imaging of nasopharyngeal carcinoma using stretched exponential diffusion model.

    abstract:PURPOSE:To determine the utility of stretched exponential diffusion model in characterisation of the water diffusion heterogeneity in different tumour stages of nasopharyngeal carcinoma (NPC). MATERIALS AND METHODS:Fifty patients with newly diagnosed NPC were prospectively recruited. Diffusion-weighted MR imaging was ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3535-9

    authors: Lai V,Lee VH,Lam KO,Sze HC,Chan Q,Khong PL

    更新日期:2015-06-01 00:00:00

  • Breath-hold MR imaging of focal liver lesions: comparison of fast and ultrasound techniques.

    abstract::The performance of breath-hold MR imaging using two T2-weighted hybrid sequences (TSE, TGSE), two T2-weighted single-shot sequences (HASTE, EPI-SE), and one T1-weighted gradient-echo sequence (FLASH) was compared with a standard conventional T2-weighted SE sequence in 20 patients with focal liver lesions. Liver signal...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00240685

    authors: Gaa J,Fischer H,Laub G,Georgi M

    更新日期:1996-01-01 00:00:00