Local staging of endometrial carcinoma: role of multidetector CT.

Abstract:

:The purpose was to evaluate the accuracy of multidetector CT (MDCT) on a 16-row CT scanner in local staging of endometrial carcinoma and more specifically in the assessment of the depth of myometrial invasion and presence of cervical infiltration. This prospective study includes 21 women with newly diagnosed endometrial carcinoma. All CT examinations were performed on a 16-row CT scanner, and the protocol included scanning of the abdomen after intravenous administration of iodinated contrast material, during the portal phase, using a detector collimation of 16 x 0.75 mm and a pitch of 1.2. Sagittal, parasagittal and oblique reformatted images were evaluated for the depth of myometrial invasion, whether superficial or deep, and the presence of cervical infiltration. Imaging findings were correlated with the histopathologic results. The sensitivity, specificity and accuracy of MDCT in evaluating myometrial invasion were 100%, 80% and 95%, respectively, and for assessing cervical infiltration were 78%, 83% and 81%, respectively. In conclusion, MDCT on a 16-row CT scanner proved accurate in local staging of endometrial carcinoma.

journal_name

Eur Radiol

journal_title

European radiology

authors

Tsili AC,Tsampoulas C,Dalkalitsis N,Stefanou D,Paraskevaidis E,Efremidis SC

doi

10.1007/s00330-007-0839-z

subject

Has Abstract

pub_date

2008-05-01 00:00:00

pages

1043-8

issue

5

eissn

0938-7994

issn

1432-1084

journal_volume

18

pub_type

杂志文章
  • Effect of TIPS placement on portal and splanchnic arterial blood flow in 4-dimensional flow MRI.

    abstract:OBJECTIVES:To assess changes in portal and splanchnic arterial haemodynamics in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) using four-dimensional (4D) flow MRI, a non-invasive, non-contrast imaging technique. METHODS:Eleven patients undergoing TIPS implantation were enrolled. K-t GRAPPA a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3663-x

    authors: Stankovic Z,Rössle M,Euringer W,Schultheiss M,Salem R,Barker A,Carr J,Langer M,Markl M,Collins JD

    更新日期:2015-09-01 00:00:00

  • Histogram analysis of diffusion kurtosis imaging derived maps may distinguish between low and high grade gliomas before surgery.

    abstract:OBJECTIVE:To investigate the value of histogram analysis of diffusion kurtosis imaging (DKI) maps in the evaluation of glioma grading. METHODS:A total of 39 glioma patients who underwent preoperative magnetic resonance imaging (MRI) were classified into low-grade (13 cases) and high-grade (26 cases) glioma groups. Par...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5108-1

    authors: Qi XX,Shi DF,Ren SX,Zhang SY,Li L,Li QC,Guan LM

    更新日期:2018-04-01 00:00:00

  • MRI of the breast in patients with DCIS to exclude the presence of invasive disease.

    abstract:OBJECTIVES:Core biopsy underestimates invasion in more than 20% of patients with preoperatively diagnosed ductal carcinoma in situ (DCIS) without evidence of invasion (pure DCIS). The aim of the current study was to evaluate the efficacy of preoperative magnetic resonance imaging (MRI) to discriminate between patients ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2394-5

    authors: Deurloo EE,Sriram JD,Teertstra HJ,Loo CE,Wesseling J,Rutgers EJ,Gilhuijs KG

    更新日期:2012-07-01 00:00:00

  • High-resolution 3D non-contrast-enhanced, ECG-gated, multi-step MR angiography of the lower extremities: comparison with contrast-enhanced MR angiography.

    abstract:OBJECTIVE:To determine the diagnostic value of non-contrast-enhanced, 3D-high-resolution, ECG-gated, multi-step MR angiography (non-ceMRA) of the lower extremities using a modified turbo-spin-echo technique in comparison to 1.0-molar contrast-enhanced MR angiography (ceMRA) in patients with suspected peripheral vascula...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1932-2

    authors: Mohrs OK,Petersen SE,Heidt MC,Schulze T,Schmitt P,Bergemann S,Kauczor HU

    更新日期:2011-02-01 00:00:00

  • Cardiac CT: coronary arteries and beyond.

    abstract::Multi-detector-row computed tomography (MDCT) has emerged as a rapidly developing method for non-invasive imaging of the heart. An understanding of ECG synchronization, contrast material administration, patient preparation and image post-processing is needed to optimize image quality. The basic technical principles an...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-006-0433-9

    authors: Mahnken AH,Mühlenbruch G,Günther RW,Wildberger JE

    更新日期:2007-04-01 00:00:00

  • Visual stimulation, 1H MR spectroscopy and fMRI of the human visual pathways.

    abstract::The purpose was to assess changes in lactate content and other brain metabolites under visual stimulation in optical chiasm, optic radiations and occipital cortex using multiple voxel MR spectroscopy (MRS). 1H chemical shift imaging (CSI) examinations of transverse planes centered to include the above structures were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2494-y

    authors: Boucard CC,Mostert JP,Cornelissen FW,De Keyser J,Oudkerk M,Sijens PE

    更新日期:2005-01-01 00:00:00

  • Meta-analysis: adjusted indirect comparison of drug-eluting bead transarterial chemoembolization versus 90Y-radioembolization for hepatocellular carcinoma.

    abstract:OBJECTIVE:To investigate comparative effectiveness of drug-eluting bead transarterial chemoembolization (DEB-TACE) versus Yttrium-90 (90Y)-radioembolization for hepatocellular carcinoma (HCC). METHODS:Studies comparing conventional (c)TACE versus 90Y-radioembolization or DEB-TACE for HCC treatment were identified usin...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析

    doi:10.1007/s00330-016-4548-3

    authors: Ludwig JM,Zhang D,Xing M,Kim HS

    更新日期:2017-05-01 00:00:00

  • Nomogram including pretherapeutic parameters for prediction of survival after SIRT of hepatic metastases from colorectal cancer.

    abstract:OBJECTIVES:Pre-therapeutic prediction of outcome is important for clinicians and patients in determining whether selective internal radiation therapy (SIRT) is indicated for hepatic metastases of colorectal cancer (CRC). METHODS:Pre-therapeutic characteristics of 100 patients with colorectal liver metastases (CRLM) tr...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3658-7

    authors: Fendler WP,Ilhan H,Paprottka PM,Jakobs TF,Heinemann V,Bartenstein P,Khalaf F,Ezziddin S,Hacker M,Haug AR

    更新日期:2015-09-01 00:00:00

  • Coronavirus disease 2019 (COVID-19) imaging reporting and data system (COVID-RADS) and common lexicon: a proposal based on the imaging data of 37 studies.

    abstract:BACKGROUND:In the vast majority of the laboratory-confirmed coronavirus disease 2019 (COVID-19) patients, computed tomography (CT) examinations yield a typical pattern and the sensitivity of this modality has been reported to be 97% in a large-scale study. Structured reporting systems simplify the interpretation and re...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06863-0

    authors: Salehi S,Abedi A,Balakrishnan S,Gholamrezanezhad A

    更新日期:2020-09-01 00:00:00

  • Growing Region Segmentation Software (GRES) for quantitative magnetic resonance imaging of multiple sclerosis: intra- and inter-observer agreement variability: a comparison with manual contouring method.

    abstract::Lesion area measurement in multiple sclerosis (MS) is one of the key points in evaluating the natural history and in monitoring the efficacy of treatments. This study was performed to check the intra- and inter-observer agreement variability of a locally developed Growing Region Segmentation Software (GRES), comparing...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300100978

    authors: Parodi RC,Sardanelli F,Renzetti P,Rosso E,Losacco C,Ferrari A,Levrero F,Pilot A,Inglese M,Mancardi GL

    更新日期:2002-04-01 00:00:00

  • Dual energy computed tomography quantification of carotid plaques calcification: comparison between monochromatic and polychromatic energies with pathology correlation.

    abstract:PURPOSE:We compared carotid plaque calcification detection sensitivity and apparent cross-sectional area on CT as a function of CT beam energy using conventional CT techniques and virtual mono-energetic CT images generated from dual-energy acquisitions. METHODS & MATERIALS:Five ex-vivo carotid endarterectomy (CEA) spe...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3523-0

    authors: Mannelli L,MacDonald L,Mancini M,Ferguson M,Shuman WP,Ragucci M,Monti S,Xu D,Yuan C,Mitsumori LM

    更新日期:2015-05-01 00:00:00

  • Assessment of the safety climate in outpatient diagnostic services: Development and psychometric evaluation of a questionnaire.

    abstract:INTRODUCTION:Safe practice and safety culture are important issues in outpatient diagnostic imaging services. As questionnaires assessing safety culture through the measurement of safety climate in this setting are not yet available, the present study aimed to develop and validate such an instrument. MATERIALS AND MET...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5646-1

    authors: Jossen M,Valeri F,Heilmaier C,Schwappach D

    更新日期:2019-03-01 00:00:00

  • Holmium-166 poly(L-lactic acid) microsphere radioembolisation of the liver: technical aspects studied in a large animal model.

    abstract:OBJECTIVE:To assess the accuracy of a scout dose of holmium-166 poly(L-lactic acid) microspheres ((166)Ho-PLLA-MS) in predicting the distribution of a treatment dose of (166)Ho-PLLA-MS, using single photon emission tomography (SPECT). METHODS:A scout dose (60 mg) was injected into the hepatic artery of five pigs and S...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1613-1

    authors: Vente MA,de Wit TC,van den Bosch MA,Bult W,Seevinck PR,Zonnenberg BA,de Jong HW,Krijger GC,Bakker CJ,van het Schip AD,Nijsen JF

    更新日期:2010-04-01 00:00:00

  • Dual-Phase Dual-Energy CT in Patients Treated with Erlotinib for Advanced Non-Small Cell Lung Cancer: Possible Benefits of Iodine Quantification in Response Assessment.

    abstract:OBJECTIVES:To investigate the relationship of dual-phase dual-energy CT (DE-CT) and tumour size in the evaluation of the response to anti-EGFR therapy in patients with advanced non-small cell lung cancer (NSCLC). METHODS:Dual-phase DE-CT was performed in 31 patients with NSCLC before the onset of anti-EGFR (erlotinib)...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4092-6

    authors: Baxa J,Matouskova T,Krakorova G,Schmidt B,Flohr T,Sedlmair M,Bejcek J,Ferda J

    更新日期:2016-08-01 00:00:00

  • ACCURATUM: improved calcium volume scoring using a mesh-based algorithm--a phantom study.

    abstract::To overcome the limitations of the classical volume scoring method for quantifying coronary calcifications, including accuracy, variability between examinations, and dependency on plaque density and acquisition parameters, a mesh-based volume measurement method has been developed. It was evaluated and compared with th...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1181-9

    authors: Saur SC,Alkadhi H,Desbiolles L,Székely G,Cattin PC

    更新日期:2009-03-01 00:00:00

  • MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking.

    abstract::The purpose of this study was to evaluate the technical feasibility of MR-guided percutaneous breast biopsy (LCNB) and breast hook wire marking in a low-field (0.23 T) MRI system with optical instrument tracking. MR-guided core biopsy and/or hook wire marking was performed on 13 lesions observable at MR imaging only. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0377-0

    authors: Sequeiros RB,Reinikainen H,Sequeiros AM,Vaara T,Ojala R,Pääkkö E,Tervonen O

    更新日期:2007-03-01 00:00:00

  • Radiomics on multi-modalities MR sequences can subtype patients with non-metastatic nasopharyngeal carcinoma (NPC) into distinct survival subgroups.

    abstract:OBJECTIVES:To explore and evaluate the feasibility of radiomics in stratifying nasopharyngeal carcinoma (NPC) into distinct survival subgroups through multi-modalities MRI. METHODS:A total of 658 patients (training cohort: 424; validation cohort: 234) with non-metastatic NPC were enrolled in the retrospective analysis...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06075-1

    authors: Zhuo EH,Zhang WJ,Li HJ,Zhang GY,Jing BZ,Zhou J,Cui CY,Chen MY,Sun Y,Liu LZ,Cai HM

    更新日期:2019-10-01 00:00:00

  • Computed diffusion-weighted imaging using 3-T magnetic resonance imaging for prostate cancer diagnosis.

    abstract:OBJECTIVE:To assess the efficacy of computed diffusion-weighted images (cDWIs) of b = 2000 s/mm(2) (cDWI2000) generated from DWIs of b = 0 and 1000 for prostate cancer (PCa) diagnosis in comparison with that of measured original DWIs of b = 1000 (mDWI1000) and b = 2000(mDWI2000) using 3-T MRI. METHODS:Eighty patients ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2958-z

    authors: Ueno Y,Takahashi S,Kitajima K,Kimura T,Aoki I,Kawakami F,Miyake H,Ohno Y,Sugimura K

    更新日期:2013-12-01 00:00:00

  • Late presentation of solitary contralateral adrenal metastasis of renal cell carcinoma.

    abstract::We report a case of renal cell carcinoma with solitary metachronous contralateral adrenal metastasis occurring 23 years after radical nephrectomy. The patient was treated with adrenalectomy. He is alive with no evidence of disease 1 year postoperatively. Solitary metachronous contralateral adrenal metastases from rena...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050204

    authors: Mesurolle B,Mignon F,Travagli JP,Meingan P,Vanel D

    更新日期:1997-01-01 00:00:00

  • Feasibility of MRI-guided large-core-needle biopsy of suspiscious breast lesions at 3 T.

    abstract::The feasibility of large-core-needle magnetic resonance imaging (MRI)-guided breast biopsy at 3 T was assessed. Thirty-one suspicious breast lesions shown only by MRI were detected in 30 patients. Biopsy procedures were performed in a closed-bore 3-T clinical MR system on a dedicated phased-array breast coil with a co...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1310-0

    authors: Peters NH,Meeuwis C,Bakker CJ,Mali WP,Fernandez-Gallardo AM,van Hillegersberg R,Schipper ME,van den Bosch MA

    更新日期:2009-07-01 00:00:00

  • Prostate cancer detection among readers with different degree of experience using ultra-high b-value diffusion-weighted Imaging: Is a non-contrast protocol sufficient to detect significant cancer?

    abstract:AIM:To evaluate the accuracy of a T2-weighted (T2w) - and a parallel transmit zoomed b = 2000 s/mm2 (b2000) - diffusion-weighted imaging sequence among three readers with different degrees of experience for prostate cancer (Pca) detection. METHODS:Ninety-three patients with suspected Pca were enrolled. For b2000 a two...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5004-8

    authors: Hausmann D,Aksöz N,von Hardenberg J,Martini T,Westhoff N,Buettner S,Schoenberg SO,Riffel P

    更新日期:2018-02-01 00:00:00

  • Research cardiac magnetic resonance imaging in end stage renal disease - incidence, significance and implications of unexpected incidental findings.

    abstract:OBJECTIVES:Left ventricular mass (LVM) at cardiac magnetic resonance imaging (CMR) is a frequent end point in clinical trials in nephrology. Trial participants with end stage renal disease (ESRD) may have a greater frequency of incidental findings (IF). We retrospectively investigated prevalence of IF in previous resea...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4288-4

    authors: Rutherford E,Weir-McCall JR,Patel RK,Houston JG,Roditi G,Struthers AD,Jardine AG,Mark PB

    更新日期:2017-01-01 00:00:00

  • Using coronary CT angiography for guiding invasive coronary angiography: potential role to reduce intraprocedural radiation exposure.

    abstract:OBJECTIVES:We investigated the potential reduction of patient exposure during invasive coronary angiography (ICA) if the procedure had only been directed to the vessel with at least one ≥ 50% stenosis as described in the CT report. METHODS:Dose reports of 61 patients referred to ICA because of at least one ≥ 50% steno...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5317-2

    authors: Arendt CT,Tischendorf P,Wichmann JL,Messerli M,Jörg L,Ehl N,Gohmann RF,Wildermuth S,Vogl TJ,Bauer RW

    更新日期:2018-07-01 00:00:00

  • Pre- and post-contrast versus post-contrast cone-beam breast CT: can we reduce radiation exposure while maintaining diagnostic accuracy?

    abstract:OBJECTIVES:To evaluate whether post-contrast cone-beam breast CT (CBBCT) alone is comparable to the current standard of combined pre- and post-contrast CBBCT regarding diagnostic accuracy and superior regarding radiation exposure. MATERIAL AND METHODS:This study included 49 women (61 breasts) with median age 57.9 year...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5854-8

    authors: Uhlig J,Fischer U,Biggemann L,Lotz J,Wienbeck S

    更新日期:2019-06-01 00:00:00

  • Radial scars diagnosed at stereotactic core-needle biopsy: surgical biopsy findings.

    abstract::We retrospectively reviewed surgical biopsy findings of lesions diagnosed as radial scars (RS) at stereotactic core-needle biopsy (SCNB). RS was diagnosed in 52 of 1415 (3.7%) consecutive mammographically detected lesions that underwent 14-gauge automated SCNB. Subsequent surgical biopsy findings were available for 43...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0196-3

    authors: López-Medina A,Cintora E,Múgica B,Operé E,Vela AC,Ibañez T

    更新日期:2006-08-01 00:00:00

  • Intra-articular ganglion cysts of the cruciate ligaments.

    abstract::Intra-articular ganglion cysts of the cruciate ligaments are associated with non-specific clinical signs and symptoms. Familiarity with the MR appearances in particular is important to make an accurate diagnosis, exclude associated abnormalities, and avoid misdiagnosis. ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003309900290

    authors: Tyrrell PN,Cassar-Pullicino VN,McCall IW

    更新日期:2000-01-01 00:00:00

  • Diffusion-weighted MR imaging including bi-exponential fitting for the detection of recurrent or residual tumour after (chemo)radiotherapy for laryngeal and hypopharyngeal cancers.

    abstract:OBJECTIVES:To assess whether diffusion-weighted magnetic resonance imaging (DW-MRI) including bi-exponential fitting helps to detect residual/recurrent tumours after (chemo)radiotherapy of laryngeal and hypopharyngeal carcinoma. METHODS:Forty-six patients with newly-developed/worsening symptoms after (chemo)radiothera...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2596-x

    authors: Tshering Vogel DW,Zbaeren P,Geretschlaeger A,Vermathen P,De Keyzer F,Thoeny HC

    更新日期:2013-02-01 00:00:00

  • MR liver imaging with Gd-EOB-DTPA: a delay time of 10 minutes is sufficient for lesion characterisation.

    abstract:OBJECTIVES:To assess whether, in patients with normal liver function, a hepatobiliary delay time of 10 min after Gd-EOB-DTPA injection is sufficient for lesion characterisation. METHODS:In 42 consecutive patients with suspected focal liver lesions, dynamic MRI was performed after intravenous Gd-EOB-DTPA, followed by h...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2486-2

    authors: van Kessel CS,Veldhuis WB,van den Bosch MA,van Leeuwen MS

    更新日期:2012-10-01 00:00:00

  • Effect of inspiration on airway dimensions measured in maximal inspiration CT images of subjects without airflow limitation.

    abstract:OBJECTIVES:To study the effect of inspiration on airway dimensions measured in voluntary inspiration breath-hold examinations. METHODS:961 subjects with normal spirometry were selected from the Danish Lung Cancer Screening Trial. Subjects were examined annually for five years with low-dose CT. Automated software was u...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1007/s00330-014-3261-3

    authors: Petersen J,Wille MM,Rakêt LL,Feragen A,Pedersen JH,Nielsen M,Dirksen A,de Bruijne M

    更新日期:2014-09-01 00:00:00

  • Quantification of diffusion tensor imaging in normal white matter maturation of early childhood using an automated processing pipeline.

    abstract:OBJECTIVES:The degree and status of white matter myelination can be sensitively monitored using diffusion tensor imaging (DTI). This study looks at the measurement of fractional anistropy (FA) and mean diffusivity (MD) using an automated ROI with an existing DTI atlas. METHODS:Anatomical MRI and structural DTI were pe...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2396-3

    authors: Loh KB,Ramli N,Tan LK,Roziah M,Rahmat K,Ariffin H

    更新日期:2012-07-01 00:00:00