MR liver imaging with Gd-EOB-DTPA: a delay time of 10 minutes is sufficient for lesion characterisation.

Abstract:

OBJECTIVES:To assess whether, in patients with normal liver function, a hepatobiliary delay time of 10 min after Gd-EOB-DTPA injection is sufficient for lesion characterisation. METHODS:In 42 consecutive patients with suspected focal liver lesions, dynamic MRI was performed after intravenous Gd-EOB-DTPA, followed by hepatobiliary phases at 5, 10 and 20 min. The following items were assessed at each hepatobiliary phase: parenchymal enhancement, contrast agent excretion in bile ducts, lesion enhancement characteristics (hypo-, iso-, or hyperintensity, rim enhancement, central non-enhancement), and contrast- and signal-to-noise ratios, separately for hypo- and hyperintense lesions. RESULTS:Following enhancement, parenchymal signal intensity increased significantly up to 10 min (86.3%, P < 0.001), and subsequently stabilised (86.5% after 20 min, P = 0.223). Biliary contrast agent excretion was first observed in 2, 32 and 5 patients after 5, 10 and 20 min respectively. Hepatobiliary lesion enhancement characteristics observed after 5 min persisted during later hepatobiliary phases. CNR and SNR ratios increased significantly (P < 0.05) up to 10 min after enhancement without further increase at 20 min, in hypo- and hyperintense lesions. CONCLUSIONS:If lesion characterisation is the primary reason for performing MRI, a hepatobiliary delay time of 10 min after Gd-EOB-DTPA injection is sufficient in patients with normal liver function. KEY POINTS :• Magnetic resonance imaging is now a first line of investigation of the liver. • Optimal CNR and SNR are achieved 10 min after Gd-EOB-DTPA injection. • Typical enhancement characteristics are observed early and do not change. • Ten-minute hepatobiliary delay is sufficient for characterisation of focal liver lesions.

journal_name

Eur Radiol

journal_title

European radiology

authors

van Kessel CS,Veldhuis WB,van den Bosch MA,van Leeuwen MS

doi

10.1007/s00330-012-2486-2

subject

Has Abstract

pub_date

2012-10-01 00:00:00

pages

2153-60

issue

10

eissn

0938-7994

issn

1432-1084

journal_volume

22

pub_type

杂志文章
  • Comprehensive morphologic and functional imaging of heart transplant patients: first experience with dynamic perfusion CT.

    abstract:OBJECTIVES:We aimed to assess the diagnostic performance of a combined protocol with coronary computed tomography angiography (CCTA) and stress CT perfusion imaging (CTP) in heart transplant patients for comprehensive morphological and functional imaging. METHODS:In this prospective study, 13 patients undergoing routi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5436-9

    authors: Oebel S,Hamada S,Higashigaito K,von Spiczak J,Klotz E,Enseleit F,Hinzpeter R,Ruschitzka F,Manka R,Alkadhi H

    更新日期:2018-10-01 00:00:00

  • Diagnostic value of commercially available shear-wave elastography for breast cancers: integration into BI-RADS classification with subcategories of category 4.

    abstract:OBJECTIVES:To evaluate the diagnostic performance of shear-wave elastography (SWE) for breast cancer and to determine whether the integration of SWE into BI-RADS with subcategories of category 4 improves the diagnostic performance. METHODS:A total of 389 breast masses (malignant 120, benign 269) in 324 women who under...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2873-3

    authors: Youk JH,Gweon HM,Son EJ,Han KH,Kim JA

    更新日期:2013-10-01 00:00:00

  • Impact of post-processing methods on apparent diffusion coefficient values.

    abstract:OBJECTIVE:The apparent diffusion coefficient (ADC) is increasingly used as a quantitative biomarker in oncological imaging. ADC calculation is based on raw diffusion-weighted imaging (DWI) data, and multiple post-processing methods (PPMs) have been proposed for this purpose. We investigated whether PPM has an impact on...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4403-6

    authors: Zeilinger MG,Lell M,Baltzer PA,Dörfler A,Uder M,Dietzel M

    更新日期:2017-03-01 00:00:00

  • CT-guided percutaneous radiofrequency denervation of the sacroiliac joint.

    abstract::Defining the origin of low back pain is a challenging task. Among a variety of factors the sacroiliac joint (SIJ) is a possible pain generator, although precise diagnosis is difficult. Joint blocks may reduce pain, but are, in cases, of only temporary effect. This study was conducted to evaluate CT-guided percutaneous...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1257-2

    authors: Gevargez A,Groenemeyer D,Schirp S,Braun M

    更新日期:2002-06-01 00:00:00

  • Percutaneous catheter and guidewire fragmentation with local administration of recombinant tissue plasminogen activator as a treatment for massive pulmonary embolism.

    abstract::The purpose of this article is to report four patients with massive pulmonary embolism treated with percutaneous catheter and guidewire fragmentation and local administration of recombinant tissue plasminogen activator (r-TPA). Four patients with massive pulmonary embolism initially underwent pulmonary angiography. Th...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050776

    authors: Murphy JM,Mulvihill N,Mulcahy D,Foley B,Smiddy P,Molloy MP

    更新日期:1999-01-01 00:00:00

  • Iodine-based contrast media, multiple myeloma and monoclonal gammopathies: literature review and ESUR Contrast Media Safety Committee guidelines.

    abstract:OBJECTIVES:Many radiologists and clinicians still consider multiple myeloma (MM) and monoclonal gammopathies (MG) a contraindication for using iodine-based contrast media. The ESUR Contrast Media Safety Committee performed a systematic review of the incidence of post-contrast acute kidney injury (PC-AKI) in these patie...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-017-5023-5

    authors: Stacul F,Bertolotto M,Thomsen HS,Pozzato G,Ugolini D,Bellin MF,Bongartz G,Clement O,Heinz-Peer G,van der Molen A,Reimer P,Webb JAW,ESUR Contrast Media Safety Committee.

    更新日期:2018-02-01 00:00:00

  • Ultrasound of the chest in children (mediastinum excluded).

    abstract::Ultrasound (US) of the paediatric chest has become an established imaging tool that may supplement plain film findings helping to reduce or tailor other ionizing (sectional) imaging in a variety of paediatric conditions such as sequestration or pneumonia. US has been shown to offer valuable imaging alternatives, both ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-007-0754-3

    authors: Riccabona M

    更新日期:2008-02-01 00:00:00

  • Diagnostics and characterisation of preocclusive stenoses and occlusions of the internal carotid artery with B-flow.

    abstract::The purpose was to evaluate whether B-flow can improve the ultrasonographic diagnosis of preocclusive stenosis and occlusion of the internal carotid artery (ICA) compared with colour-coded Doppler and power Doppler. Ninety patients with occlusions or preocclusive stenoses of the ICA suspected by Doppler sonography wer...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0285-3

    authors: Jung EM,Kubale R,Ritter G,Gallegos MT,Jungius KP,Rupp N,Clevert DA

    更新日期:2007-02-01 00:00:00

  • Computer-aided detection (CAD) for breast MRI: evaluation of efficacy at 3.0 T.

    abstract:OBJECTIVE:The purpose of the study was to evaluate the accuracy of 3.0-T breast MRI interpretation using manual and fully automated kinetic analyses. MATERIAL AND METHODS:Manual MRI interpretation was done on an Advantage Workstation. Retrospectively, all examinations were processed with a computer-aided detection (CA...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1573-5

    authors: Meeuwis C,van de Ven SM,Stapper G,Fernandez Gallardo AM,van den Bosch MA,Mali WP,Veldhuis WB

    更新日期:2010-03-01 00:00:00

  • Performance of ultralow-dose CT with iterative reconstruction in lung cancer screening: limiting radiation exposure to the equivalent of conventional chest X-ray imaging.

    abstract:OBJECTIVE:To investigate the detection rate of pulmonary nodules in ultralow-dose CT acquisitions. MATERIALS AND METHODS:In this lung phantom study, 232 nodules (115 solid, 117 ground-glass) of different sizes were randomly distributed in a lung phantom in 60 different arrangements. Every arrangement was acquired once...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4192-3

    authors: Huber A,Landau J,Ebner L,Bütikofer Y,Leidolt L,Brela B,May M,Heverhagen J,Christe A

    更新日期:2016-10-01 00:00:00

  • Magnetic resonance angiography in the resectability assessment of suspected pancreatic tumours.

    abstract::The aim of this prospective study was to evaluate MRI, including MR angiography (MRA), in the preoperative assessment of the resectability of suspected malignancy of the pancreas. A total of 17 patients with suspected pancreatic carcinoma and planned surgery were investigated with conventional angiography, ultrasonogr...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF02742919

    authors: Smedby O,Riesenfeld V,Karlson B,Jacobson G,Löfberg A,Lindgren PG,Ahlström H

    更新日期:1997-01-01 00:00:00

  • Virtual endoscopy of the tracheo-bronchial system: sub-millimeter collimation with the 16-row multidetector scanner.

    abstract::The purpose of this study was to evaluate the scope of sub-millimeter collimation reconstruction parameters using 16-row computer tomography and ECG triggering on image quality in virtual bronchoscopy. Thirty-two patients (5 women, 27 men, mean age 66.6+/-1.4) who had been admitted for coronary artery bypass graft sur...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00330-004-2325-1

    authors: Khan MF,Herzog C,Ackermann H,Wagner TO,Maataoui A,Harth M,Abolmaali ND,Jacobi V,Vogl TJ

    更新日期:2004-08-01 00:00:00

  • Reduced GABA levels correlate with cognitive impairment in patients with relapsing-remitting multiple sclerosis.

    abstract:OBJECTIVES:To investigate if brain gamma-aminobutyric acid (GABA) levels in patients with relapsing-remitting multiple sclerosis (RRMS) are abnormal compared with healthy controls, and their relationship to cognitive function in RRMS. METHODS:Twenty-eight RRMS patients and twenty-six healthy controls underwent magneti...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5064-9

    authors: Cao G,Edden RAE,Gao F,Li H,Gong T,Chen W,Liu X,Wang G,Zhao B

    更新日期:2018-03-01 00:00:00

  • The impact of injector-based contrast agent administration in time-resolved MRA.

    abstract:OBJECTIVES:Time-resolved contrast-enhanced MR angiography (4D-MRA), which allows the simultaneous visualization of the vasculature and blood-flow dynamics, is widely used in clinical routine. In this study, the impact of two different contrast agent injection methods on 4D-MRA was examined in a controlled, standardized...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5178-0

    authors: Budjan J,Attenberger UI,Schoenberg SO,Pietsch H,Jost G

    更新日期:2018-05-01 00:00:00

  • Prediction of infarction development after endovascular stroke therapy with dual-energy computed tomography.

    abstract:OBJECTIVES:After intraarterial recanalisation (IAR), the haemorrhage and the blood-brain barrier (BBB) disruption can be distinguished using dual-energy computed tomography (DECT). The aim of the present study was to investigate whether future infarction development can be predicted from DECT. METHODS:DECT scans of 20...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4412-5

    authors: Djurdjevic T,Rehwald R,Knoflach M,Matosevic B,Kiechl S,Gizewski ER,Glodny B,Grams AE

    更新日期:2017-03-01 00:00:00

  • Automatic opportunistic osteoporosis screening using low-dose chest computed tomography scans obtained for lung cancer screening.

    abstract:OBJECTIVE:Osteoporosis is a prevalent and treatable condition, but it remains underdiagnosed. In this study, a deep learning-based system was developed to automatically measure bone mineral density (BMD) for opportunistic osteoporosis screening using low-dose chest computed tomography (LDCT) scans obtained for lung can...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06679-y

    authors: Pan Y,Shi D,Wang H,Chen T,Cui D,Cheng X,Lu Y

    更新日期:2020-07-01 00:00:00

  • 2D SPLASH: a new method to determine the fatty infiltration of the rotator cuff muscles.

    abstract::The objective of this paper is to quantify the fatty degeneration (infiltration) of rotator cuff muscles with a new spectroscopic FLASH (SPLASH) sequence. Before planned surgery (reconstruction or muscle transfer), 20 patients (13 men, 7 women; 35-75 years) with different stages of rotator cuff disease underwent an MR...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2410-5

    authors: Kenn W,Böhm D,Gohlke F,Hümmer C,Köstler H,Hahn D

    更新日期:2004-12-01 00:00:00

  • Endorectal magnetic resonance imaging of prostatic cancer: comparison between fat-suppressed T2-weighted fast spin echo and three-dimensional dual-echo, steady-state sequences.

    abstract::The aim of this study was to develop an endorectal MRI strategy for prostatic cancer. We evaluated the MR images from 44 consecutive prostatic cancer patients treated by radical prostatectomy. Each sequence from every examination was assessed separately with a specific tumor map drawn. Tumor localization, capsular pen...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000598

    authors: Ikonen S,Kärkkäinen P,Kivisaari L,Salo JO,Taari K,Vehmas T,Tervahartiala P,Rannikko S

    更新日期:2001-01-01 00:00:00

  • Automated computer-aided stenosis detection at coronary CT angiography: initial experience.

    abstract:OBJECTIVE:To evaluate the performance of a computer-aided algorithm for automated stenosis detection at coronary CT angiography (cCTA). METHODS:We investigated 59 patients (38 men, mean age 58 +/- 12 years) who underwent cCTA and quantitative coronary angiography (QCA). All cCTA data sets were analyzed using a softwar...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1644-7

    authors: Arnoldi E,Gebregziabher M,Schoepf UJ,Goldenberg R,Ramos-Duran L,Zwerner PL,Nikolaou K,Reiser MF,Costello P,Thilo C

    更新日期:2010-05-01 00:00:00

  • Multislice computed tomography perfusion imaging for visualization of acute pulmonary embolism: animal experience.

    abstract::The purpose of our animal study was to evaluate a new computed tomography (CT) subtraction technique for visualization of perfusion defects within the lung parenchyma in subsegmental pulmonary embolism (PE). Seven healthy pigs were entered into a prospective trial. Acute PE was artificially induced by fresh clot mater...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2718-9

    authors: Wildberger JE,Klotz E,Ditt H,Spüntrup E,Mahnken AH,Günther RW

    更新日期:2005-07-01 00:00:00

  • Effect of radiation dose level on the detectability of pulmonary nodules in chest tomosynthesis.

    abstract:OBJECTIVE:To investigate the detectability of pulmonary nodules in chest tomosynthesis at reduced radiation dose levels. METHODS:Eighty-six patients were included in the study and were examined with tomosynthesis and computed tomography (CT). Artificial noise was added to simulate that the tomosynthesis images were ac...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3182-1

    authors: Asplund SA,Johnsson ÅA,Vikgren J,Svalkvist A,Flinck A,Boijsen M,Fisichella VA,Månsson LG,Båth M

    更新日期:2014-07-01 00:00:00

  • Diagnosing adenomyosis with MRI: a prospective study revisiting the junctional zone thickness cutoff of 12 mm as a diagnostic marker.

    abstract:OBJECTIVES:To assess the diagnostic accuracy of a junctional zone (JZ) thickness of ≥ 12 mm and morphological features of the JZ in MRI in diagnosing adenomyosis in a premenopausal study population. METHODS:This single-center, prospective observational study consecutively enrolled 93 premenopausal women suffering from...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06308-3

    authors: Tellum T,Matic GV,Dormagen JB,Nygaard S,Viktil E,Qvigstad E,Lieng M

    更新日期:2019-12-01 00:00:00

  • Influence of statin treatment on coronary atherosclerosis visualised using multidetector computed tomography.

    abstract:OBJECTIVE:Coronary angiography using multidetector computed tomography (MDCT) allows non-invasive assessment of non-calcified, calcified and mixed plaques. Progression of coronary plaques may be influenced by statins. METHODS:Sixty-three consecutive patients underwent MDCT as a follow-up to their original CT angiograp...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00330-010-1880-x

    authors: Hoffmann H,Frieler K,Schlattmann P,Hamm B,Dewey M

    更新日期:2010-12-01 00:00:00

  • Isoattenuating insulinomas at biphasic contrast-enhanced CT: frequency, clinicopathologic features and perfusion characteristics.

    abstract:OBJECTIVES:We aimed to determine the frequency of isoattenuating insulinomas, to investigate their clinicopathological features and to assess their regional pancreatic perfusion characteristics. METHODS:Institutional review board approval was obtained, and patient informed consent was waived. From July 2010 to June 20...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4216-7

    authors: Zhu L,Xue HD,Sun H,Wang X,He YL,Jin ZY,Zhao YP

    更新日期:2016-10-01 00:00:00

  • Integrated diagnostic imaging of primary thoracic rhabdomyosarcoma.

    abstract::We report a rare case of primary thoracic rhabdomyosarcoma in a girl who was referred with acute chest pain, hacking cough, and wheezing. A chest X-ray revealed a complete opacity of the right hemithorax. Ultrasound revealed a right-sided pleural effusion and a solid mass above the liver dome, suggesting a neoplastic ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000507

    authors: Almberger M,Iannicelli E,Matrunola M,Schiavetti A,Capocaccia P

    更新日期:2001-01-01 00:00:00

  • MDCT Linear and Volumetric Analysis of Adrenal Glands: Normative Data and Multiparametric Assessment.

    abstract:OBJECTIVES:To study linear and volumetric adrenal measurements, their reproducibility, and correlations between total adrenal volume (TAV) and adrenal micronodularity, age, gender, body mass index (BMI), visceral (VAAT) and subcutaneous adipose tissue volume (SAAT), presence of diabetes, chronic alcoholic abuse and chr...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4063-y

    authors: Carsin-Vu A,Oubaya N,Mulé S,Janvier A,Delemer B,Soyer P,Hoeffel C

    更新日期:2016-08-01 00:00:00

  • Preservation of the endometrial enhancement after magnetic resonance imaging-guided high-intensity focused ultrasound ablation of submucosal uterine fibroids.

    abstract:OBJECTIVE:To evaluate the integrity of endometrial enhancement after magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) ablation of submucosal uterine fibroids based on contrast-enhanced MRI findings, and to identify the risk factors for endometrial impairment. METHODS:In total, 117 submucos...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4765-4

    authors: Kim YS,Kim TJ,Lim HK,Rhim H,Jung SH,Ahn JH,Lee JW,Kim BG

    更新日期:2017-09-01 00:00:00

  • Extracellular volume fraction determined by equilibrium contrast-enhanced multidetector computed tomography as a prognostic factor in unresectable pancreatic adenocarcinoma treated with chemotherapy.

    abstract:OBJECTIVES:To assess whether extracellular volume (ECV) fraction with equilibrium contrast-enhanced multidetector computed tomography (MDCT) predicts outcomes for unresectable pancreatic adenocarcinoma patients treated with chemotherapy METHODS: Sixty-seven patients (42 men, 25 women; mean age, 67.5 years; range, 45-83...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5570-4

    authors: Fukukura Y,Kumagae Y,Higashi R,Hakamada H,Takumi K,Maemura K,Higashi M,Kamimura K,Nakajo M,Yoshiura T

    更新日期:2019-01-01 00:00:00

  • Cardiac pathologies in female carriers of Duchenne muscular dystrophy assessed by cardiovascular magnetic resonance imaging.

    abstract:OBJECTIVES:Duchenne muscular dystrophy (DMD) is the most common and severe dystrophinopathy. DMD carriers rarely present with clinical symptoms, but may suffer from cardiac involvement. Because echocardiographic findings are inconsistent and cardiac magnetic resonance imaging (CMRI) data are limited, this study sought ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3694-3

    authors: Schelhorn J,Schoenecker A,Neudorf U,Schemuth H,Nensa F,Nassenstein K,Forsting M,Schara U,Schlosser T

    更新日期:2015-10-01 00:00:00

  • Cardiac CT: coronary arteries and beyond.

    abstract::Multi-detector-row computed tomography (MDCT) has emerged as a rapidly developing method for non-invasive imaging of the heart. An understanding of ECG synchronization, contrast material administration, patient preparation and image post-processing is needed to optimize image quality. The basic technical principles an...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-006-0433-9

    authors: Mahnken AH,Mühlenbruch G,Günther RW,Wildberger JE

    更新日期:2007-04-01 00:00:00