Intraventricular mass lesions of the brain.

Abstract:

:Intraventricular tumours represent a diverse group of lesions, some of them infrequent, with a wide variety of radiological features. Determination of their precise aetiology or origin can be difficult. Nevertheless, considering patient's age, location within the ventricles, and some specific radiological features, the radiologist should be able to narrow down the differential diagnosis. This paper reviews the characteristic radiological appearances of the diverse intraventricular lesions emphasising its differential diagnosis.

journal_name

Eur Radiol

journal_title

European radiology

authors

Majós C,Coll S,Aguilera C,Acebes JJ,Pons LC

doi

10.1007/s003300051044

subject

Has Abstract

pub_date

2000-01-01 00:00:00

pages

951-61

issue

6

eissn

0938-7994

issn

1432-1084

journal_volume

10

pub_type

杂志文章
  • Enhancement characteristics of liver metastases, hepatocellular carcinomas, and hemangiomas with Gd-EOB-DTPA: preliminary results with dynamic MR imaging.

    abstract::Our objective was to study Gd-EOB-DTPA for the characterization of focal liver lesions by means of dynamic MR imaging. A double-blind and randomized dose-ranging phase-2 clinical trial was performed in 31 patients (liver metastases n = 23, hepatocellular carcinoma n = 4, and hemangioma n = 4) at a field strength of 1....

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/s003300050150

    authors: Reimer P,Rummeny EJ,Daldrup HE,Hesse T,Balzer T,Tombach B,Peters PE

    更新日期:1997-01-01 00:00:00

  • The role of imaging in 2019 novel coronavirus pneumonia (COVID-19).

    abstract::Almost the entire world, not only China, is currently experiencing the outbreak of a novel coronavirus that causes respiratory disease, severe pneumonia, and even death. The outbreak began in Wuhan, China, in December of 2019 and is currently still ongoing. This novel coronavirus is highly contagious and has resulted ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-020-06827-4

    authors: Yang W,Sirajuddin A,Zhang X,Liu G,Teng Z,Zhao S,Lu M

    更新日期:2020-09-01 00:00:00

  • Intrauterine fetal MR versus postmortem MR imaging after therapeutic termination of pregnancy: evaluation of the concordance in the detection of brain abnormalities at early gestational stage.

    abstract:BACKGROUND AND PURPOSE:Fetal postmortem MR Imaging (pmMRI) has been recently used as an adjuvant tool to conventional brain autopsy after termination of pregnancy (TOP). Our purpose was to compare the diagnostic performance of intrauterine MRI (iuMRI) and pmMRI in the detection of brain anomalies in fetuses at early ge...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5878-0

    authors: Izzo G,Talenti G,Falanga G,Moscatelli M,Conte G,Scola E,Doneda C,Parazzini C,Rustico M,Triulzi F,Righini A

    更新日期:2019-06-01 00:00:00

  • Diagnostic value of time-resolved CT angiography for the lower leg.

    abstract:OBJECTIVE:The aim of this study was to test the feasibility of time-resolved computed tomography angiography (TR-CTA) for use in the lower leg. METHODS:Fifty-nine patients with suspected peripheral arterial occlusive disease were examined with a standard CTA (S-CTA) of the lower run-off and with an additional TR-CTA o...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1861-0

    authors: Sommer WH,Helck A,Bamberg F,Albrecht E,Becker CR,Weidenhagen R,Kramer H,Reiser MF,Nikolaou K

    更新日期:2010-12-01 00:00:00

  • Quantitative CT detects progression in COPD patients with severe emphysema in a 3-month interval.

    abstract:OBJECTIVES:Chronic obstructive pulmonary disease (COPD) is characterized by variable contributions of emphysema and airway disease on computed tomography (CT), and still little is known on their temporal evolution. We hypothesized that quantitative CT (QCT) is able to detect short-time changes in a cohort of patients w...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06577-y

    authors: Konietzke P,Wielpütz MO,Wagner WL,Wuennemann F,Kauczor HU,Heussel CP,Eichinger M,Eberhardt R,Gompelmann D,Weinheimer O

    更新日期:2020-05-01 00:00:00

  • An optimised patient-specific approach to administration of contrast agent for CT pulmonary angiography.

    abstract:OBJECTIVES:To investigate pulmonary vasculature opacification during CTPA using an optimised patient-specific protocol for administering contrast agent. METHODS:CTPA was performed on 200 patients with suspected PE. Patients were assigned to two protocol groups: protocol A, fixed 80 ml contrast agent; protocol B used a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2919-6

    authors: Saade C,Bourne R,El-Merhi F,Somanathan A,Chakraborty D,Brennan P

    更新日期:2013-11-01 00:00:00

  • Normal hepatic parenchyma visibility and ADC quantification on diffusion-weighted MRI at 3 T: influence of age, gender, and iron content.

    abstract:OBJECTIVES:To investigate how normal liver parenchyma visibility on 3 T diffusion-weighted images (DWI) and apparent diffusion coefficient (ADC) quantification are influenced by age, gender, and iron content. METHODS:Between February 2011 and April 2013, 86 patients (52 women) with normal livers who underwent respirat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3353-0

    authors: Metens T,Ferraresi KF,Farchione A,Moreno C,Bali MA,Matos C

    更新日期:2014-12-01 00:00:00

  • Reproducibility of linear tumor measurements using PACS: comparison of caliper method with edge-tracing method.

    abstract::The aim of this study was to evaluate inter- and intra-observer reproducibility when making electronic caliper linear tumor measurements on picture archiving and communications systems (PACS) and compare them with linear measurements obtained from circumferential tracing of tumor perimeter. Three radiologists measured...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-2027-0

    authors: Monsky WL,Raptopoulos V,Keogan MT,Doty D,Kamel I,Yam CS,Ransil BJ

    更新日期:2004-03-01 00:00:00

  • Virtual endoscopy of the tracheo-bronchial system: sub-millimeter collimation with the 16-row multidetector scanner.

    abstract::The purpose of this study was to evaluate the scope of sub-millimeter collimation reconstruction parameters using 16-row computer tomography and ECG triggering on image quality in virtual bronchoscopy. Thirty-two patients (5 women, 27 men, mean age 66.6+/-1.4) who had been admitted for coronary artery bypass graft sur...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00330-004-2325-1

    authors: Khan MF,Herzog C,Ackermann H,Wagner TO,Maataoui A,Harth M,Abolmaali ND,Jacobi V,Vogl TJ

    更新日期:2004-08-01 00:00:00

  • High-resolution flat panel CT versus 3-T MR arthrography of the wrist: initial results in vivo.

    abstract:OBJECTIVES:The objective of this study was to compare the diagnostic performance of direct C-arm flat panel computed tomography arthrography (FPCT-A) with direct magnetic resonance arthrography (MR-A) of the wrist in patients with clinically suspected pathologies. METHODS:Forty-nine patients underwent tri-compartmenta...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5901-5

    authors: Sonnow L,Koennecker S,Luketina R,Werncke T,Hinrichs JB,Meyer BC,Wacker FK,von Falck C

    更新日期:2019-06-01 00:00:00

  • Protective effect against repeat adverse reactions to iodinated contrast medium: Premedication vs. changing the contrast medium.

    abstract:OBJECTIVES:The purpose of this study was to assess the protective effect of premedication and changing contrast media (CM) against repeat adverse reactions (ARs) to iodinated CM. METHODS:Between January 2006 and September 2014, 771 cases with previous ARs to CM were administered CM. The same CM that had caused ARs pre...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4028-1

    authors: Abe S,Fukuda H,Tobe K,Ibukuro K

    更新日期:2016-07-01 00:00:00

  • Neurilemoma of the renal capsule: MR imaging and pathologic correlation.

    abstract::We report a case of neurilemoma arising from the renal capsule. Renal neurilemoma is an especially rare tumor, with only 15 cases previously reported. We attempted to correlate MR findings with microscopic components of the tumor. On T2-weighted images the solid part of the tumor was heterogeneous hyperintense. The MR...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000767

    authors: Tsurusaki M,Mimura F,Yasui N,Minayoshi K,Sugimura K

    更新日期:2001-01-01 00:00:00

  • CT assessment-based direct surgical resection of part-solid nodules with solid component larger than 5 mm without preoperative biopsy: experience at a single tertiary hospital.

    abstract:OBJECTIVES:To retrospectively evaluate the feasibility of CT assessment-based direct surgical resection of part-solid nodules (PSNs) with solid components > 5 mm without preoperative percutaneous transthoracic needle biopsies (PTNBs). METHODS:From January 2009-December 2014, 85 PSNs with solid components > 5 mm on CT ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4917-6

    authors: Lee SM,Park CM,Song YS,Kim H,Kim YT,Park YS,Goo JM

    更新日期:2017-12-01 00:00:00

  • Non-mass lesions detected by breast US: stratification of cancer risk for clinical management.

    abstract:OBJECTIVE:To develop a classification system using imaging features to interpret breast non-mass lesions (NMLs) detected on US and to stratify their cancer risk. METHODS:This retrospective study included 715 patients with 715 breast NMLs detected on breast US from 2012 to 2016. Each patient underwent mammography at th...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07168-y

    authors: Park KW,Park S,Shon I,Kim MJ,Han BK,Ko EY,Ko ES,Shin JH,Kwon MR,Choi JS

    更新日期:2020-09-04 00:00:00

  • Magnetic resonance imaging of the fetal lung: a pictorial essay.

    abstract::Ultrasound, which is now a widely available and generally accepted, low-cost technique with real-time properties, is the screening investigation of choice in fetal medicine. However, enthusiasm for fetal prenatal magnetic resonance imaging (MRI) is rising, because of the absence of known biological risks, the increasi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0877-1

    authors: Cannie M,Jani J,De Keyzer F,Van Kerkhove F,Meersschaert J,Lewi L,Deprest J,Dymarkowski S

    更新日期:2008-07-01 00:00:00

  • Opportunistic screening for osteoporosis on routine computed tomography? An external validation study.

    abstract:OBJECTIVES:Opportunistic screening for osteoporosis using computed tomography (CT) examinations that happen to visualise the spine can be used to identify patients with osteoporosis. We sought to verify the diagnostic performance of vertebral Hounsfield unit (HU) measurements on routine CT examinations for diagnosing o...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3584-0

    authors: Buckens CF,Dijkhuis G,de Keizer B,Verhaar HJ,de Jong PA

    更新日期:2015-07-01 00:00:00

  • The clinical value of a negative multi-detector computed tomographic angiography in patients suspected of coronary artery disease: A meta-analysis.

    abstract::The aim of this meta-analysis was to calculate the sensitivity of contrast-enhanced multi-detector computed tomography (MDCT) compared with coronary angiography (CAG) in incident patients suspected of coronary artery disease (CAD). We searched PubMed, Embase, bibliographies of original papers and reviews to identify o...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析

    doi:10.1007/s00330-006-0312-4

    authors: van der Zaag-Loonen HJ,Dikkers R,de Bock GH,Oudkerk M

    更新日期:2006-12-01 00:00:00

  • Gastric cancer and image-derived quantitative parameters: Part 2-a critical review of DCE-MRI and 18F-FDG PET/CT findings.

    abstract::There is yet no consensus on the application of functional imaging and qualitative image interpretation in the management of gastric cancer. In this second part, we will discuss the role of image-derived quantitative parameters from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and 18F-fluorodeoxygluc...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-019-06370-x

    authors: Tang L,Wang XJ,Baba H,Giganti F

    更新日期:2020-01-01 00:00:00

  • US-guided diffused optical tomography: a promising functional imaging technique in breast lesions.

    abstract:OBJECTIVE:To investigate the feasibility and clinical efficacy of ultrasound (US)-guided diffused optical tomography (DOT) in differentiating malignant breast lesions from benign lesions. MATERIAL AND METHODS:From October 2007 to August 2008, 198 women with 214 lesions scheduled for open biopsy were included in this s...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1551-y

    authors: You SS,Jiang YX,Zhu QL,Liu JB,Zhang J,Dai Q,Liu H,Sun Q

    更新日期:2010-02-01 00:00:00

  • Association of "initial CT" findings with mortality in older patients with coronavirus disease 2019 (COVID-19).

    abstract:OBJECTIVES:To investigate the association of chest CT findings with mortality in clinical management of older patients. METHODS:From January 21 to February 14, 2020, 98 older patients (≥ 60 years) who had undergone chest CT scans ("initial CT") on admission were enrolled. Manifestation and CT score were compared betwe...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06969-5

    authors: Li Y,Yang Z,Ai T,Wu S,Xia L

    更新日期:2020-11-01 00:00:00

  • Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation.

    abstract:OBJECTIVE:The aim of the study was to assess the performance and diagnostic value of a dual energy CT approach to reduce metal artefacts in subjects with metallic implants. METHODS:31 patients were examined in the area of their metallic implants using a dual energy CT protocol (filtered 140 kVp and 100 kVp spectrum, t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2062-1

    authors: Bamberg F,Dierks A,Nikolaou K,Reiser MF,Becker CR,Johnson TR

    更新日期:2011-07-01 00:00:00

  • MRI-CEST assessment of tumour perfusion using X-ray iodinated agents: comparison with a conventional Gd-based agent.

    abstract:OBJECTIVES:X-ray iodinated contrast media have been shown to generate contrast in MR images when used with the chemical exchange saturation transfer (CEST) approach. The aim of this study is to compare contrast enhancement (CE) capabilities and perfusion estimates between radiographic molecules and a Gd-based contrast ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4552-7

    authors: Anemone A,Consolino L,Longo DL

    更新日期:2017-05-01 00:00:00

  • Do quantitative and qualitative shear wave elastography have a role in evaluating musculoskeletal soft tissue masses?

    abstract:OBJECTIVES:To determine if quantitative and qualitative shear wave elastography have roles in evaluating musculoskeletal masses. METHODS:105 consecutive patients, prospectively referred for biopsy within a specialist sarcoma centre, underwent B-mode, quantitative (m/s) and qualitative (colour map) shear wave elastogra...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4427-y

    authors: Pass B,Jafari M,Rowbotham E,Hensor EM,Gupta H,Robinson P

    更新日期:2017-02-01 00:00:00

  • Comprehensive evaluation of macroscopic and microscopic myocardial fibrosis by cardiac MR: intra-individual comparison of gadobutrol versus gadoterate meglumine.

    abstract:PURPOSE:Late gadolinium enhancement cardiac MR (LGE-CMR) and extracellular volume fraction (ECV-CMR) are widely used to evaluate macroscopic and microscopic myocardial fibrosis. Macrocyclic contrast media are increasingly used off-label for myocardial scar assessment, given the superior safety profile of these agents. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5956-3

    authors: Rahsepar AA,Ghasemiesfe A,Suwa K,Dolan RS,Shehata ML,Korell MJ,Naresh NK,Markl M,Collins JD,Carr JC

    更新日期:2019-08-01 00:00:00

  • Early survival prediction after intra-arterial therapies: a 3D quantitative MRI assessment of tumour response after TACE or radioembolization of colorectal cancer metastases to the liver.

    abstract:OBJECTIVES:This study evaluated the predictive role of 1D, 2D and 3D quantitative, enhancement-based MRI regarding overall survival (OS) in patients with colorectal liver metastases (CLM) following intra-arterial therapies (IAT). METHODS:This retrospective analysis included 29 patients who underwent transarterial chem...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3595-5

    authors: Chapiro J,Duran R,Lin M,Schernthaner R,Lesage D,Wang Z,Savic LJ,Geschwind JF

    更新日期:2015-07-01 00:00:00

  • Functional diagnosis of placenta accreta by intravoxel incoherent motion model diffusion-weighted imaging.

    abstract:OBJECTIVES:To investigate the diagnostic value of intravoxel incoherent motion (IVIM) DWI for placenta accreta by comparing diffusion and perfusion characteristics of placentas with accreta lesions (APs) with those of normal placentas (NPs). METHODS:Twenty-five pregnant women with AP and 24 with NP underwent 3-T magne...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07200-1

    authors: Bao Y,Pang Y,Sun Z,Li Q,Tang D,Xia L

    更新日期:2021-02-01 00:00:00

  • Dual energy computed tomography quantification of carotid plaques calcification: comparison between monochromatic and polychromatic energies with pathology correlation.

    abstract:PURPOSE:We compared carotid plaque calcification detection sensitivity and apparent cross-sectional area on CT as a function of CT beam energy using conventional CT techniques and virtual mono-energetic CT images generated from dual-energy acquisitions. METHODS & MATERIALS:Five ex-vivo carotid endarterectomy (CEA) spe...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3523-0

    authors: Mannelli L,MacDonald L,Mancini M,Ferguson M,Shuman WP,Ragucci M,Monti S,Xu D,Yuan C,Mitsumori LM

    更新日期:2015-05-01 00:00:00

  • Prognostic value of anthropometric measures extracted from whole-body CT using deep learning in patients with non-small-cell lung cancer.

    abstract:INTRODUCTION:The aim of the study was to extract anthropometric measures from CT by deep learning and to evaluate their prognostic value in patients with non-small-cell lung cancer (NSCLC). METHODS:A convolutional neural network was trained to perform automatic segmentation of subcutaneous adipose tissue (SAT), viscer...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06630-w

    authors: Blanc-Durand P,Campedel L,Mule S,Jegou S,Luciani A,Pigneur F,Itti E

    更新日期:2020-06-01 00:00:00

  • Dysplasia epiphysealis hemimelica of the scaphoid bone.

    abstract::We report a rare case of dysplasia epiphysealis hemimelica (DEH) in the wrist of a 7-year-old boy. Clinical, radiological and histopathological manifestations are discussed. The correct diagnosis of DEH, however, was made by the confrontation of the radiological and pathological data. The radiologist should inform the...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050766

    authors: Vanhoenacker F,Morlion J,De Schepper AM,Callewaert E

    更新日期:1999-01-01 00:00:00

  • Hepatic artery pseudoaneurysm treated using stent-graft implantation and retrograde gastroduodenal artery coil embolization.

    abstract::Endovascular treatment options for visceral artery pseudoaneurysms depend on lesion location and size. Exclusion methods fall into two categories, embolization and stent placement, and these procedures aim to exclude the pseudoaneurysm from the circulation and if possible to maintain distal blood flow. Embolization of...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1053-3

    authors: Basile A,Ragazzi S,Piazza D,Tsetis D,Lupattelli T,Patti MT

    更新日期:2008-11-01 00:00:00