US-guided diffused optical tomography: a promising functional imaging technique in breast lesions.

Abstract:

OBJECTIVE:To investigate the feasibility and clinical efficacy of ultrasound (US)-guided diffused optical tomography (DOT) in differentiating malignant breast lesions from benign lesions. MATERIAL AND METHODS:From October 2007 to August 2008, 198 women with 214 lesions scheduled for open biopsy were included in this study. Conventional US was used to locate the breast lesion, and DOT to measure the total haemoglobin concentration (THC) for each breast lesion. Sensitivity, specificity and overall accuracy were determined with surgical pathology as the gold standard. RESULTS:There were 96 benign lesions and 118 malignant lesions. The total haemoglobin concentration (THC) of all 214 lesions was calculated from DOT. The average THC in benign lesions was 125.5 +/- 83.4 micromol/L, and in malignant lesions 222.2 +/- 87.2 micromol/L. The THC of malignant lesions was significantly higher than that of benign lesions (p < 0.05). When a THC of 140 micromol/L was used as the cutoff value for differentiating breast cancer from benign lesions, the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of DOT were 83.9%, 66.7%, 76.2%, 75.6% and 77.1%, respectively. Our study demonstrated that THC was significantly higher in malignant lesions than in benign lesions. CONCLUSION:US-guided diffused optical tomography, a noninvasive functional imaging technique, has potential utility in differentiating breast cancer from benign lesions.

journal_name

Eur Radiol

journal_title

European radiology

authors

You SS,Jiang YX,Zhu QL,Liu JB,Zhang J,Dai Q,Liu H,Sun Q

doi

10.1007/s00330-009-1551-y

subject

Has Abstract

pub_date

2010-02-01 00:00:00

pages

309-17

issue

2

eissn

0938-7994

issn

1432-1084

journal_volume

20

pub_type

杂志文章
  • Radiomics from magnetic resonance imaging may be used to predict the progression of white matter hyperintensities and identify associated risk factors.

    abstract:OBJECTIVE:The progression of white matter hyperintensities (WMH) varies considerably in adults. In this study, we aimed to predict the progression and related risk factors of WMH based on the radiomics of whole-brain white matter (WBWM). METHODS:A retrospective analysis was conducted on 141 patients with WMH who under...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06676-1

    authors: Shu Z,Xu Y,Shao Y,Pang P,Gong X

    更新日期:2020-06-01 00:00:00

  • The clinical value of a negative multi-detector computed tomographic angiography in patients suspected of coronary artery disease: A meta-analysis.

    abstract::The aim of this meta-analysis was to calculate the sensitivity of contrast-enhanced multi-detector computed tomography (MDCT) compared with coronary angiography (CAG) in incident patients suspected of coronary artery disease (CAD). We searched PubMed, Embase, bibliographies of original papers and reviews to identify o...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析

    doi:10.1007/s00330-006-0312-4

    authors: van der Zaag-Loonen HJ,Dikkers R,de Bock GH,Oudkerk M

    更新日期:2006-12-01 00:00:00

  • High-risk lesions diagnosed at MRI-guided vacuum-assisted breast biopsy: can underestimation be predicted?

    abstract:OBJECTIVES:To evaluate the frequency of diagnosis of high-risk lesions at MRI-guided vacuum-assisted breast biopsy (MRgVABB) and to determine whether underestimation may be predicted. METHODS:Retrospective review of the medical records of 161 patients who underwent MRgVABB was performed. The underestimation rate was d...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1949-6

    authors: Crystal P,Sadaf A,Bukhanov K,McCready D,O'Malley F,Helbich TH

    更新日期:2011-03-01 00:00:00

  • Perianal complications of Crohn disease: MR imaging findings.

    abstract::The aim of this study was to revisit anal anatomy, to explain surgical terminology in perianal complications of Crohn disease, and to show the MR imaging findings of perianal fistulas and abscesses. To this end more than 200 patients were studied using surface coils (Helmholtz; phased array) at 1.0 and 1.5 T. Transver...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050248

    authors: Laniado M,Makowiec F,Dammann F,Jehle EC,Claussen CD,Starlinger M

    更新日期:1997-01-01 00:00:00

  • Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography.

    abstract::We assessed the effect of intra-coronary attenuation on diagnostic accuracy using 64-slice computed tomography coronary angiography (CT-CA). We enrolled 170 patients with suspected coronary artery disease who underwent conventional coronary angiography (CA) and 64-slice CT-CA (100 ml of Iomeprol 400 mg I/ml at 4 ml/s)...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0773-0

    authors: Cademartiri F,Maffei E,Palumbo AA,Malagò R,La Grutta L,Meiijboom WB,Aldrovandi A,Fusaro M,Vignali L,Menozzi A,Brambilla V,Coruzzi P,Midiri M,Kirchin MA,Mollet NR,Krestin GP

    更新日期:2008-03-01 00:00:00

  • Late gadolinium enhancement cardiac imaging on a 3T scanner with parallel RF transmission technique: prospective comparison of 3D-PSIR and 3D-IR.

    abstract:OBJECTIVE:To qualitatively and quantitatively compare different late gadolinium enhancement (LGE) sequences acquired at 3T with a parallel RF transmission technique. METHODS:One hundred and sixty participants prospectively enrolled underwent a 3T cardiac MRI with 3 different LGE sequences: 3D Phase-Sensitive Inversion...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4002-y

    authors: Schultz A,Caspar T,Schaeffer M,Labani A,Jeung MY,El Ghannudi S,Roy C,Ohana M

    更新日期:2016-06-01 00:00:00

  • Adhesive capsulitis: role of MR imaging in differential diagnosis.

    abstract::The purpose of this study was to describe and characterize the MR imaging findings in a group of patients who underwent surgery for adhesive capsulitis. Twenty-four MR imaging studies in 24 consecutive patients with clinical evidence of adhesive capsulitis were performed prior to arthroscopic capsulotomy. There were 1...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1349-7

    authors: Connell D,Padmanabhan R,Buchbinder R

    更新日期:2002-08-01 00:00:00

  • Asbestosis and other pulmonary fibrosis in asbestos-exposed workers: high-resolution CT features with pathological correlations.

    abstract:OBJECTIVE:The purpose was to identify distinguishing CT features of pathologically diagnosed asbestosis, and correlate diagnostic confidence with asbestos body burden. METHODS:Thirty-three workers (mean age at CT: 73 years) with clinical diagnoses of asbestosis, who were autopsied (n = 30) or underwent lobectomy (n = ...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-015-3973-z

    authors: Arakawa H,Kishimoto T,Ashizawa K,Kato K,Okamoto K,Honma K,Hayashi S,Akira M

    更新日期:2016-05-01 00:00:00

  • Assessment of pulmonary venous stenosis after radiofrequency catheter ablation for atrial fibrillation by magnetic resonance angiography: A comparison of linear and cross-sectional area measurements.

    abstract::One of the recognised complications of catheter ablation is pulmonary venous stenosis. The aim of this study was to compare two methods of evaluation of pulmonary venous diameter for follow-up assessment of the above complication: (1) a linear approach evaluating two main diameters of the vein, (2) semiautomatically m...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0358-3

    authors: Tintera J,Porod V,Cihák R,Mlcochová H,Rolencová E,Fendrych P,Kautzner J

    更新日期:2006-12-01 00:00:00

  • Differentiation of predominant subtypes of lung adenocarcinoma using a quantitative radiomics approach on CT.

    abstract:OBJECTIVES:To develop a model for differentiating the predominant subtype-based prognostic groups of lung adenocarcinoma using CT radiomic features, and to validate its performance in comparison with radiologists' assessments. METHODS:A total of 993 patients presenting with invasive lung adenocarcinoma between March 2...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06805-w

    authors: Park S,Lee SM,Noh HN,Hwang HJ,Kim S,Do KH,Seo JB

    更新日期:2020-09-01 00:00:00

  • Iopentol (Imagopaque 300 and 350) compared with iohexol (Omnipaque 300 and 350) in cerebral and aortic arch angiography. A clinical trial assessing adverse events and diagnostic information.

    abstract::The safety of the non-ionic contrast medium iopentol (Imagopaque, Nycomed Imaging AS, Oslo, Norway) when used in cerebral angiography and aortic arch angiography, was the focus of this investigation. Overall quality of visualization and changes in heart rate and blood pressure were, however, also assessed. In total, 3...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/pl00006884

    authors: Ericsson K,Bjartveit K

    更新日期:1997-01-01 00:00:00

  • Multiple pulmonary artery pseudoaneurysms: intrasaccular embolization.

    abstract::We report the case of a 32-year-old female presenting with two pulmonary artery false aneurysms of mycotic origin. Considering the natural history and potential complications, we treated the patient by intrasaccular embolization with steel coils. No complication occurred. ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050130

    authors: Ghaye B,Trotteur G,Dondelinger RF

    更新日期:1997-01-01 00:00:00

  • Angiomyolipoma (AML) without visible fat: Ultrasound, CT and MR imaging features with pathological correlation.

    abstract:OBJECTIVE:To compare imaging findings with histopathology in AML without visible fat (AMLwvf). MATERIAL AND METHODS:With IRB approval, we identified 18 AMLwvf that underwent CT between 2002-2014. A radiologist measured NECT-attenuation, corticomedullary (CM) and nephrographic (NG) enhancement, echogenicity relative to...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3851-8

    authors: Hakim SW,Schieda N,Hodgdon T,McInnes MD,Dilauro M,Flood TA

    更新日期:2016-02-01 00:00:00

  • A new technique for noise reduction at coronary CT angiography with multi-phase data-averaging and non-rigid image registration.

    abstract:OBJECTIVES:To investigate the feasibility of a newly developed noise reduction technique at coronary CT angiography (CTA) that uses multi-phase data-averaging and non-rigid image registration. METHODS:Sixty-five patients underwent coronary CTA with prospective ECG-triggering. The range of the phase window was set at 7...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3381-9

    authors: Tatsugami F,Higaki T,Nakamura Y,Yamagami T,Date S,Fujioka C,Kiguchi M,Kihara Y,Awai K

    更新日期:2015-01-01 00:00:00

  • Adrenal ganglioneuroblastoma in pregnant woman: diagnosis with three-dimensional ultrasound.

    abstract::The diagnostic approach for evaluation of adrenal tumour in pregnant women is a problem. This article presents the multifactorial diagnosis of rare, incidentally detected massive adrenal tumour with 2D and 3D US. Grey-scale 2D and 3D US with tissue harmonic imaging showed inhomogeneous, encapsulated, solid tumour of t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1457-4

    authors: Slapa RZ,Jakubowski W,Kasperlik-Zaluska AA,Szopiñski K,Debski R,Samsel M,Polañski J,Borowicz K

    更新日期:2002-12-01 00:00:00

  • Papillary vs clear cell renal cell carcinoma. Differentiation and grading by iodine concentration using DECT-correlation with microvascular density.

    abstract:OBJECTIVES:Various imaging methods have been evaluated regarding non-invasive differentiation of renal cell carcinoma (RCC) subtypes. Dual-energy computed tomography (DECT) allows iodine concentration (IC) analysis as a correlate of tissue perfusion. Microvascular density (MVD) in histopathology specimens is evaluated ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06298-2

    authors: Marcon J,Graser A,Horst D,Casuscelli J,Spek A,Stief CG,Reiser MF,Rübenthaler J,Buchner A,Staehler M

    更新日期:2020-01-01 00:00:00

  • Quantification of radiation dose savings in cardiac computed tomography using prospectively triggered mode and ECG pulsing: a phantom study.

    abstract:OBJECTIVE:To quantify radiation dose reduction in cardiac computed tomography (CT) using a prospectively triggered mode compared with a retrospective ECG-gated helical mode. METHODS:Absorbed organ doses in cardiac 64-row multidetector CT were quantified using an anthropomorphic male Alderson phantom with 74 thermolumi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1767-x

    authors: Lehmkuhl L,Gosch D,Nagel HD,Stumpp P,Kahn T,Gutberlet M

    更新日期:2010-09-01 00:00:00

  • Diagnostic accuracy of low-dose CT compared with abdominal radiography in non-traumatic acute abdominal pain: prospective study and systematic review.

    abstract:OBJECTIVES:Abdominal radiography is frequently used in acute abdominal non-traumatic pain despite the availability of more advanced diagnostic modalities. This study evaluates the diagnostic accuracy of low-dose CT compared with abdominal radiography, at similar radiation dose levels. METHODS:Fifty-eight patients were...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-015-3984-9

    authors: Alshamari M,Norrman E,Geijer M,Jansson K,Geijer H

    更新日期:2016-06-01 00:00:00

  • TACE with degradable starch microspheres (DSM-TACE) as second-line treatment in HCC patients dismissing or ineligible for sorafenib.

    abstract:OBJECTIVES:To date, there is no approved second-line treatment for patients dismissing sorafenib or ineligible for this treatment, so it would be useful to find an effective alternative treatment option. The aim of our study was to evaluate safety, feasibility and effectiveness of transarterial chemoembolisation with d...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5692-8

    authors: Iezzi R,Pompili M,Rinninella E,Annicchiarico E,Garcovich M,Cerrito L,Ponziani F,De Gaetano A,Siciliano M,Basso M,Zocco MA,Rapaccini G,Posa A,Carchesio F,Biolato M,Giuliante F,Gasbarrini A,Manfredi R,HepatoCatt Study G

    更新日期:2019-03-01 00:00:00

  • Time-resolved computed tomography of the liver: retrospective, multi-phase image reconstruction derived from volumetric perfusion imaging.

    abstract:OBJECTIVE:To assess feasibility and image quality (IQ) of a new post-processing algorithm for retrospective extraction of an optimised multi-phase CT (time-resolved CT) of the liver from volumetric perfusion imaging. METHODS:Sixteen patients underwent clinically indicated perfusion CT using 4D spiral mode of dual-sour...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2992-x

    authors: Fischer MA,Leidner B,Kartalis N,Svensson A,Aspelin P,Albiin N,Brismar TB

    更新日期:2014-01-01 00:00:00

  • Bone marrow edema around the hip in non-traumatic pain: dual-energy CT vs MRI.

    abstract:OBJECTIVES:To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) in identifying bone marrow edema (BME) around the hip joint in non-traumatic patients. METHODS:This prospective IRB-approved study was conducted between January 2019 and October 2019 and included 59 consecutive patients (18 males,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06775-z

    authors: Foti G,Faccioli N,Silva R,Oliboni E,Zorzi C,Carbognin G

    更新日期:2020-07-01 00:00:00

  • Smart chest X-ray worklist prioritization using artificial intelligence: a clinical workflow simulation.

    abstract:OBJECTIVE:The aim is to evaluate whether smart worklist prioritization by artificial intelligence (AI) can optimize the radiology workflow and reduce report turnaround times (RTATs) for critical findings in chest radiographs (CXRs). Furthermore, we investigate a method to counteract the effect of false negative predict...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07480-7

    authors: Baltruschat I,Steinmeister L,Nickisch H,Saalbach A,Grass M,Adam G,Knopp T,Ittrich H

    更新日期:2020-11-21 00:00:00

  • Wave-CAIPI susceptibility-weighted imaging achieves diagnostic performance comparable to conventional susceptibility-weighted imaging in half the scan time.

    abstract:OBJECTIVES:We aimed to evaluate the agreement in the detection of cerebral microbleeds (CMBs) between conventional susceptibility-weighted imaging (SWI) and fast SWI using wave-controlled aliasing in parallel imaging (CAIPI) acceleration. We also scrutinized the diagnostic agreement for intracranial lesions and compare...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06574-1

    authors: Chung MS,Lee EJ,Kim S,Kim SO,Byun JS

    更新日期:2020-04-01 00:00:00

  • Systolic prospectively ECG-triggered dual-source CT angiography for evaluation of the coronary arteries in heart transplant recipients.

    abstract:OBJECTIVES:To assess feasibility, image quality, and radiation dose of prospectively ECG-triggered coronary CT angiography (CTA) in orthotopic heart transplant (OHT) recipients. METHODS:47 consecutive OHT recipients (40 men, mean age 62.1 ± 10.9 years, mean heart rate 86.3 ± 14.4 bpm) underwent dual-source CTA to rule...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2126-2

    authors: Bastarrika G,Broncano J,Arraiza M,Azcárate PM,Simon-Yarza I,Levy Praschker BG,Pueyo JC,Zubieta JL,Rabago G

    更新日期:2011-09-01 00:00:00

  • Heterotropic mesenteric ossification: a case report (2004:10b).

    abstract::Heterotropic mesenteric ossification is a rare entity. Only a few cases have been described in the literature. We report a case of heterotropic mesenteric ossification in a patient who underwent several laparotomies, after suffering from multiple gunshot wounds. We discuss the radiographic findings of this disease tha...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2464-4

    authors: Tonino BA,van der Meulen HG,Kuijpers KC,Mallens WM,van Gils AP

    更新日期:2005-01-01 00:00:00

  • Quantitative assessment of tumour associated neovascularisation in patients with liver cirrhosis and hepatocellular carcinoma: role of dynamic-CT perfusion imaging.

    abstract:OBJECTIVE:To determine the value of perfusion computed tomography (CT-p) in the quantitative assessment of tumour-related neoangiogenesis processes in patients with hepatocellular carcinoma (HCC). MATERIALS AND METHODS:Fifty-two biopsy proven HCC lesions were examined with dynamic CT investigations during injection of...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2307-z

    authors: Ippolito D,Capraro C,Casiraghi A,Cestari C,Sironi S

    更新日期:2012-04-01 00:00:00

  • The effect of tube voltage combination on image artefact and radiation dose in dual-source dual-energy CT: comparison between conventional 80/140 kV and 80/150 kV plus tin filter for gout protocol.

    abstract:OBJECTIVES:In dual-source CT, dual-energy (DE) performance is affected by various X-ray tube voltage combinations with and without tin filter (Sn). The purpose of this study was to assess the utility of the 80/150 Sn kV voltage combination in terms of image artefact and radiation dose for DECT gout protocol, compared w...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5622-9

    authors: Jeon JY,Lee SW,Jeong YM,Baek HJ

    更新日期:2019-03-01 00:00:00

  • Usefulness of colour Doppler flow imaging in the management of lacrimal gland lesions.

    abstract:OBJECTIVE:To assess the role of colour Doppler flow imaging (CDFI) in the diagnosis and management of lacrimal fossa lesions. METHODS:Institutional ethical committee approval was obtained. Fifty-one patients with 62 lacrimal fossa lesions were retrospectively included from 2003-2015. All patients underwent conventiona...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4438-8

    authors: Lecler A,Boucenna M,Lafitte F,Koskas P,Nau E,Jacomet PV,Galatoire O,Morax S,Putterman M,Mann F,Héran F,Sadik JC,Picard H,Bergès O

    更新日期:2017-02-01 00:00:00

  • Length and angle measurements of the lower extremity in digital composite overview images.

    abstract::We here introduce a digital scanning method for determining leg length and angles. The leg length and angle measurements, image quality and radiation dose were evaluated. A composite overview image was reconstructed from a series of individual images. In 45 overview images, the total leg length and the femoro-tibial a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2352-y

    authors: Boewer M,Arndt H,Ostermann PA,Petersein J,Mutze S

    更新日期:2005-01-01 00:00:00

  • Precise measurement of renal filtration and vascular parameters using a two-compartment model for dynamic contrast-enhanced MRI of the kidney gives realistic normal values.

    abstract:OBJECTIVE:To model the uptake phase of T(1)-weighted DCE-MRI data in normal kidneys and to demonstrate that the fitted physiological parameters correlate with published normal values. METHODS:The model incorporates delay and broadening of the arterial vascular peak as it appears in the capillary bed, two distinct comp...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2382-9

    authors: Tofts PS,Cutajar M,Mendichovszky IA,Peters AM,Gordon I

    更新日期:2012-06-01 00:00:00