Wave-CAIPI susceptibility-weighted imaging achieves diagnostic performance comparable to conventional susceptibility-weighted imaging in half the scan time.

Abstract:

OBJECTIVES:We aimed to evaluate the agreement in the detection of cerebral microbleeds (CMBs) between conventional susceptibility-weighted imaging (SWI) and fast SWI using wave-controlled aliasing in parallel imaging (CAIPI) acceleration. We also scrutinized the diagnostic agreement for intracranial lesions and compared the image quality between both sequences. METHODS:Institutional review board approval was obtained and informed consent was waived for this retrospective study. We included 181 consecutive patients who had undergone brain MRI with both conventional SWI (scan time, 251 s) and wave-CAIPI SWI (scan time, 113 s) from September 2017 to November 2017. All images were independently reviewed by two radiologists for the detection and counting of CMBs using the Microbleed Anatomical Rating Scale (MARS). One neuroradiologist diagnosed intracranial lesions and scored image quality using visual analysis. The agreement for detection of CMBs and intracranial lesions was calculated, and interobserver agreements were analyzed by using kappa and intraclass correlation. RESULTS:For detection of CMBs, both the conventional and wave-CAIPI SWI showed significantly high agreement of 100% for the presence of CMBs, and 94.5% using MARS. Wave-CAIPI SWI achieved more than 97% agreement of MARS when divided by anatomical locations, with excellent agreement. Interobserver agreements were also excellent. The diagnosis for intracranial lesions (33 lesions in 28 patients) demonstrated 100% agreement. The image quality of both sequences is not significantly different (p = 0.20). CONCLUSIONS:Wave-CAIPI SWI achieved high agreement for CMB detection and diagnosis of intracranial lesions compared to conventional SWI within half of the scan time. KEY POINTS:• Wave-CAIPI SWI achieves a diagnostic performance for the detection of cerebral microbleeds that is comparable to that of conventional SWI in half the scan time. • Interobserver agreement for the detection (presence vs. absence) and counting of cerebral microbleeds of wave-CAIPI SWI was excellent. • Wave-CAIPI SWI demonstrated a 100% agreement for the diagnosis of intracranial lesions and comparable image quality compared to conventional SWI.

journal_name

Eur Radiol

journal_title

European radiology

authors

Chung MS,Lee EJ,Kim S,Kim SO,Byun JS

doi

10.1007/s00330-019-06574-1

subject

Has Abstract

pub_date

2020-04-01 00:00:00

pages

2182-2190

issue

4

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-019-06574-1

journal_volume

30

pub_type

杂志文章
  • In vivo effects of bupivacaine and gadobutrol on the intervertebral disc following discoblock and discography: a histological analysis.

    abstract:OBJECTIVES:The aim of the present study was to histologically compare chondrotoxicity in surgically harvested intervertebral discs (IVDs) of patients following discoblock, discography, or no preoperative intervention. METHODS:Thirty patients (IVD degeneration Modic ≥ 2°, Pfirrmann 3° or 4°) at L4/5 or L5/S1 who were p...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-016-4358-7

    authors: Strube P,Pfitzner BM,Streitparth F,Hartwig T,Putzier M

    更新日期:2017-01-01 00:00:00

  • MR imaging of thymomas: a combined radiomics nomogram to predict histologic subtypes.

    abstract:OBJECTIVES:Accurately predicting the WHO classification of thymomas is urgently needed to optimize individualized therapeutic strategies. We aimed to develop and validate a combined radiomics nomogram for personalized prediction of histologic subtypes in patients with thymomas. METHODS:A total of 182 thymoma patients ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07074-3

    authors: Xiao G,Hu YC,Ren JL,Qin P,Han JC,Qu XY,Rong WC,Yan WQ,Tian Q,Han Y,Wang WP,Wang SM,Ma J,Wang W,Cui GB

    更新日期:2021-01-01 00:00:00

  • Comparison of synthetic and digital mammography with digital breast tomosynthesis or alone for the detection and classification of microcalcifications.

    abstract:OBJECTIVE:To compare the performance of synthetic mammography (SM) and digital mammography (DM) with digital breast tomosynthesis (DBT) or alone for the evaluation of microcalcifications. METHODS:This retrospective study includes 198 mammography cases, all with DM, SM, and DBT images, from January to October 2013. Thr...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5585-x

    authors: Choi JS,Han BK,Ko EY,Kim GR,Ko ES,Park KW

    更新日期:2019-01-01 00:00:00

  • Diagnosing adenomyosis with MRI: a prospective study revisiting the junctional zone thickness cutoff of 12 mm as a diagnostic marker.

    abstract:OBJECTIVES:To assess the diagnostic accuracy of a junctional zone (JZ) thickness of ≥ 12 mm and morphological features of the JZ in MRI in diagnosing adenomyosis in a premenopausal study population. METHODS:This single-center, prospective observational study consecutively enrolled 93 premenopausal women suffering from...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06308-3

    authors: Tellum T,Matic GV,Dormagen JB,Nygaard S,Viktil E,Qvigstad E,Lieng M

    更新日期:2019-12-01 00:00:00

  • Quantification of left ventricular function and mass in heart transplant recipients using dual-source CT and MRI: initial clinical experience.

    abstract::The purpose of this study was to compare LV function and mass quantification derived from cardiac dual-source CT (DSCT) exams with those obtained by MRI in heart transplant recipients. Twelve heart transplant recipients who underwent cardiac DSCT and MRI examination were included. Double-oblique short-axis 8-mm slice ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0949-2

    authors: Bastarrika G,Arraiza M,De Cecco CN,Mastrobuoni S,Ubilla M,Rábago G

    更新日期:2008-09-01 00:00:00

  • ESR/ERS statement paper on lung cancer screening.

    abstract::In Europe, lung cancer ranks third among the most common cancers, remaining the biggest killer. Since the publication of the first European Society of Radiology and European Respiratory Society joint white paper on lung cancer screening (LCS) in 2015, many new findings have been published and discussions have increase...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-020-06727-7

    authors: Kauczor HU,Baird AM,Blum TG,Bonomo L,Bostantzoglou C,Burghuber O,Čepická B,Comanescu A,Couraud S,Devaraj A,Jespersen V,Morozov S,Agmon IN,Peled N,Powell P,Prosch H,Ravara S,Rawlinson J,Revel MP,Silva M,Snoeckx A,

    更新日期:2020-06-01 00:00:00

  • Incidence, risk factors, and prognostic indicators of symptomatic air embolism after percutaneous transthoracic lung biopsy: a systematic review and pooled analysis.

    abstract:OBJECTIVES:To determine the incidence, risk factors, and prognostic indicators of symptomatic air embolism after percutaneous transthoracic lung biopsy (PTLB) by conducting a systematic review and pooled analysis. METHODS:We searched the EMBASE and OVID-MEDLINE databases to identify studies that dealt with air embolis...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07372-w

    authors: Lee JH,Yoon SH,Hong H,Rho JY,Goo JM

    更新日期:2020-10-13 00:00:00

  • Woven polydioxanone biodegradable stents: a new treatment option for benign and malignant oesophageal strictures.

    abstract:BACKGROUND:We present our initial experience with a new biodegradable (BD) esophageal stent in two patients, one for a therapy-resistant benign esophageal stricture, and the other as a temporary measure during curative radiotherapy for oesophageal carcinoma. METHODS:The BD stents need to be loaded into a conventional ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1662-5

    authors: Stivaros SM,Williams LR,Senger C,Wilbraham L,Laasch HU

    更新日期:2010-05-01 00:00:00

  • Diagnostic value of MRI-derived liver surface nodularity score for the non-invasive quantification of hepatic fibrosis in non-alcoholic fatty liver disease.

    abstract:OBJECTIVES:To assess the accuracy of MRI-derived liver surface nodularity (LSN) score for staging of hepatic fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). METHODS:Forty-seven patients with clinicopathological diagnosis of NAFLD who underwent 1.5-T liver MRI within 12 months of liver biopsy were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07114-y

    authors: Catania R,Furlan A,Smith AD,Behari J,Tublin ME,Borhani AA

    更新日期:2021-01-01 00:00:00

  • Diagnosis of peripheral bone and prosthetic joint infections: overview on the consensus documents by the EANM, EBJIS, and ESR (with ESCMID endorsement).

    abstract:OBJECTIVES:Peripheral bone infection (PBI) and prosthetic joint infection (PJI) are two different infectious conditions of the musculoskeletal system. They have in common to be quite challenging to be diagnosed and no clear diagnostic flowchart has been established. Thus, a conjoined initiative on these two topics has ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-019-06326-1

    authors: Sconfienza LM,Signore A,Cassar-Pullicino V,Cataldo MA,Gheysens O,Borens O,Trampuz A,Wörtler K,Petrosillo N,Winkler H,Vanhoenacker FMHM,Jutte PC,Glaudemans AWJM

    更新日期:2019-12-01 00:00:00

  • Diagnostic utility of an echo-contrast agent in patients with synovitis using power Doppler ultrasound: a preliminary study with comparison to contrast-enhanced MRI.

    abstract::The purpose of this study was to first evaluate Levovist (Schering, Berlin, Germany), an echo-contrast agent, during power Doppler sonography (PDS) in patients with synovitis using asymptomatic joints as controls. Then we evaluated the accuracy of this technique against contrast-enhanced MRI. Forty patients (19 men an...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s003300000650

    authors: Magarelli N,Guglielmi G,Di Matteo L,Tartaro A,Mattei PA,Bonomo L

    更新日期:2001-01-01 00:00:00

  • Effect of radiation dose level on the detectability of pulmonary nodules in chest tomosynthesis.

    abstract:OBJECTIVE:To investigate the detectability of pulmonary nodules in chest tomosynthesis at reduced radiation dose levels. METHODS:Eighty-six patients were included in the study and were examined with tomosynthesis and computed tomography (CT). Artificial noise was added to simulate that the tomosynthesis images were ac...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3182-1

    authors: Asplund SA,Johnsson ÅA,Vikgren J,Svalkvist A,Flinck A,Boijsen M,Fisichella VA,Månsson LG,Båth M

    更新日期:2014-07-01 00:00:00

  • Bone marrow edema around the hip in non-traumatic pain: dual-energy CT vs MRI.

    abstract:OBJECTIVES:To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) in identifying bone marrow edema (BME) around the hip joint in non-traumatic patients. METHODS:This prospective IRB-approved study was conducted between January 2019 and October 2019 and included 59 consecutive patients (18 males,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06775-z

    authors: Foti G,Faccioli N,Silva R,Oliboni E,Zorzi C,Carbognin G

    更新日期:2020-07-01 00:00:00

  • The RETAIN project: DICOM teleradiology over an ATM-based network. Radiological Examinations Transfer on an ATM Integrated Network.

    abstract::The RETAIN project (Radiological Examinations Transfer on an ATM Integrated Network) has aimed at testing videoconferencing and DICOM image transfers to get advice about difficult radiological cases over an asynchronous transfer mode (ATM)-based network, which affords a more comfortable interface than narrow-band netw...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050029

    authors: Heautot JF,Eichelberg M,Gibaud B,Tréguier C,Lemoine D,Scarabin JM,Piqueras J,Carsin M,Gandon Y

    更新日期:2000-01-01 00:00:00

  • Impact of sublingual nitroglycerin dosage on FFRCT assessment and coronary luminal volume-to-myocardial mass ratio.

    abstract:OBJECTIVES:Fractional flow reserve computed tomography (FFRCT) depends upon nitroglycerin (NTG) inducing maximal hyperemia. However, the impact of NTG dosages on FFRCT analysis including coronary volume-to-mass ratio (V/M) is unknown. METHODS:Eighty patients with repeat coronary CT angiograms (CCTAs) with different su...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06293-7

    authors: Holmes KR,Fonte TA,Weir-McCall J,Anastasius M,Blanke P,Payne GW,Ellis J,Murphy DT,Taylor C,Leipsic JA,Sellers SL

    更新日期:2019-12-01 00:00:00

  • Contrast-induced nephropathy.

    abstract::How contrast medium-induced nephropathy (CIN) comes about is not fully understood, although CIN constitutes a leading cause of renal failure. Here, a short review of clinical trials and a more thorough outline of mechanisms thought to cause CIN are outlined. Osmolality is only one of several physicochemical properties...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s10406-005-0113-x

    authors: Persson PB

    更新日期:2005-11-01 00:00:00

  • Infrahyoid spread of deep neck abscess: anatomical consideration.

    abstract::The aim of this study was to determine the pathway of infrahyoid extension of the oropharyngeal abscess considering the anatomy of the fascial spaces by cross-sectional imaging. CT scans and MR images were retrospectively reviewed in ten patients with known infrahyoid extension of oropharyngeal abscesses (eight with a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050495

    authors: Ojiri H,Tada S,Ujita M,Ariizumi M,Ishii C,Mizunuma K,Fukuda K

    更新日期:1998-01-01 00:00:00

  • Automated CT volumetry of pulmonary metastases: the effect of a reduced growth threshold and target lesion number on the reliability of therapy response assessment using RECIST criteria.

    abstract::The purpose of this study was to evaluate the reproducibility of CT-volumetric tumour response assessment of pulmonary metastasis using variable volume change thresholds (VCT) and target lesions with response evaluation criteria in solid tumours (RECIST). Fifty consecutive patients with pulmonary metastases undergoing...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0642-x

    authors: Marten K,Auer F,Schmidt S,Rummeny EJ,Engelke C

    更新日期:2007-10-01 00:00:00

  • Clinical impact of an adaptive statistical iterative reconstruction algorithm for detection of hypervascular liver tumours using a low tube voltage, high tube current MDCT technique.

    abstract:OBJECTIVES:To investigate the impact of an adaptive statistical iterative reconstruction (ASiR) algorithm on diagnostic accuracy and confidence for the diagnosis of hypervascular liver tumours, as well as the reader's perception of image quality, using a low tube voltage (80 kVp), high tube current computed tomography ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2964-1

    authors: Marin D,Choudhury KR,Gupta RT,Ho LM,Allen BC,Schindera ST,Colsher JG,Samei E,Nelson RC

    更新日期:2013-12-01 00:00:00

  • Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time.

    abstract::The influence of the frequency of computed tomography (CT) image acquisition on the diagnostic quality of dynamic perfusion CT (PCT) studies of the brain was investigated. Eight patients with clinically suspected acute ischemia of one hemisphere underwent PCT, performed on average 3.4 h after the onset of symptoms. Si...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1083-x

    authors: Wiesmann M,Berg S,Bohner G,Klingebiel R,Schöpf V,Stoeckelhuber BM,Yousry I,Linn J,Missler U

    更新日期:2008-12-01 00:00:00

  • Contrast-enhanced three-dimensional MR angiography in the assessment of subclavian artery diseases.

    abstract::The purpose of this prospective study was to determine the potential diagnostic value of 3D breath-hold contrast-enhanced MRA (CEMRA) in the evaluation of subclavian artery pathology, and to compare CEMRA and digital subtraction angiography (DSA) findings. The study group included 50 patients with suspicion of subclav...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000454

    authors: Cosottini M,Zampa V,Petruzzi P,Ortori S,Cioni R,Bartolozzi C

    更新日期:2000-01-01 00:00:00

  • Efficacy of contrast-enhanced FDG PET/CT in patients awaiting liver transplantation with rising alpha-fetoprotein after bridge therapy of hepatocellular carcinoma.

    abstract:OBJECTIVE:To assess the diagnostic accuracy and illustrate positive findings of contrast-enhanced fluorine-18 fluoro-D-glucose positron emission tomography/computed tomography (18F-FDG PET/CT) image in patients awaiting liver transplantation (LT) with rising alpha-fetoprotein (AFP) after bridge therapy of hepatocellula...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-018-5425-z

    authors: Refaat R,Basha MAA,Hassan MS,Hussein RS,El Sammak AA,El Sammak DAEA,Radwan MHS,Awad NM,Saad El-Din SA,Elkholy E,Ibrahim DRD,Saleh SA,Montasser IF,Said H

    更新日期:2018-12-01 00:00:00

  • High-resolution real-time compound ultrasound imaging of transient protein-losing gastropathy of childhood.

    abstract::We report the case of a 1.5-year-old girl with transient protein-losing gastropathy with hypertrophic gastric folds (PLGH). The diagnosis of PLGH was made by abdominal ultrasound (US) and not by an upper gastrointestinal (UGI) study as reported in many previous publications. Real-time compound ultrasound imaging showe...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-2071-9

    authors: Smet MH,Mussen E,Ectors N,Breysem L

    更新日期:2003-12-01 00:00:00

  • Inter-scan and inter-scanner variation of quantitative dual-energy CT: evaluation with three different scanner types.

    abstract:OBJECTIVES:To investigate inter-scan and inter-scanner variation of iodine concentration (IC) and attenuation in virtual monoenergetic images at 65 keV (HU65keV) in patients with repeated abdominal examinations on dual-source (dsDECT), rapid kV switching (rsDECT), and dual-layer detector DECT (dlDECT). METHODS:We retr...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07611-0

    authors: Lennartz S,Parakh A,Cao J,Zopfs D,Große Hokamp N,Kambadakone A

    更新日期:2021-01-14 00:00:00

  • Baseline 3D-ADC outperforms 2D-ADC in predicting response to treatment in patients with colorectal liver metastases.

    abstract:OBJECTIVES:To examine the value of baseline 3D-ADC and to predict short-term response to treatment in patients with hepatic colorectal metastases (CLMs). METHODS:Liver MR images of 546 patients with CLMs (2008-2015) were reviewed retrospectively and 68 patients fulfilled inclusion criteria. Patients had received syste...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06289-3

    authors: Fouladi DF,Zarghampour M,Pandey P,Pandey A,Varzaneh FN,Ghasabeh MA,Khoshpouri P,Kamel IR

    更新日期:2020-01-01 00:00:00

  • High resolution MRI of the breast at 3 T: which BI-RADS® descriptors are most strongly associated with the diagnosis of breast cancer?

    abstract:OBJECTIVE:To identify which breast lesion descriptors in the ACR BI-RADS® MRI lexicon are most strongly associated with the diagnosis of breast cancer when performing breast MR imaging at 3 T. METHODS:150 patients underwent breast MR imaging at 3 T. Lesion size, morphology and enhancement kinetics were assessed accord...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2256-6

    authors: Pinker-Domenig K,Bogner W,Gruber S,Bickel H,Duffy S,Schernthaner M,Dubsky P,Pluschnig U,Rudas M,Trattnig S,Helbich TH

    更新日期:2012-02-01 00:00:00

  • Breast augmentation and reconstructive surgery: MR imaging of implant rupture and malignancy.

    abstract::The purpose of this study was to assess the diagnostic accuracy of MRI in detecting prosthesis integrity and malignancy after breast augmentation and reconstruction. Forty-one implants in 25 patients were analyzed by MRI before surgical removal. Imaging results were compared with ex vivo findings. Magnetic resonance i...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1362-x

    authors: Herborn CU,Marincek B,Erfmann D,Meuli-Simmen C,Wedler V,Bode-Lesniewska B,Kubik-Huch RA

    更新日期:2002-09-01 00:00:00

  • Automated computer-based CT stratification as a predictor of outcome in hypersensitivity pneumonitis.

    abstract:BACKGROUND:Hypersensitivity pneumonitis (HP) has a variable clinical course. Modelling of quantitative CALIPER-derived CT data can identify distinct disease phenotypes. Mortality prediction using CALIPER analysis was compared to the interstitial lung disease gender, age, physiology (ILD-GAP) outcome model. METHODS:CAL...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4697-4

    authors: Jacob J,Bartholmai BJ,Rajagopalan S,Karwoski R,Mak SM,Mok W,Della Casa G,Sugino K,Walsh SLF,Wells AU,Hansell DM

    更新日期:2017-09-01 00:00:00

  • The etiological role of concha bullosa in chronic sinusitis.

    abstract::The etiological role of concha bullosa in chronic sinusitis is controversial. Previous investigators have not studied the relationship between the location of concha bullosa and different chronic sinusitis patterns. We performed coronal paranasal sinuses CT in 100 Chinese patients with signs and symptoms of chronic si...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00182491

    authors: Lam WW,Liang EY,Woo JK,Van Hasselt A,Metreweli C

    更新日期:1996-01-01 00:00:00

  • Noninvasive stress testing of myocardial ischemia: comparison of GRE-MRI perfusion and wall motion analysis to 99 mTc-MIBI-SPECT, relation to coronary angiography.

    abstract::In the evaluation of ischemic heart disease only MR imaging seems to have the potential to assess myocardial perfusion, function, and coronary morphology on a single instrument. The aim of this study was to assess the feasibility of a stress test with dipyridamole (0. 56 mg/kg) to analyze myocardial perfusion by Gd fi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050238

    authors: Bremerich J,Buser P,Bongartz G,Müller-Brand J,Grädel C,Pfisterer M,Steinbrich W

    更新日期:1997-01-01 00:00:00