The etiological role of concha bullosa in chronic sinusitis.

Abstract:

:The etiological role of concha bullosa in chronic sinusitis is controversial. Previous investigators have not studied the relationship between the location of concha bullosa and different chronic sinusitis patterns. We performed coronal paranasal sinuses CT in 100 Chinese patients with signs and symptoms of chronic sinusitis and recorded the presence and location of the concha bullosa and the pattern of sinonasal disease. The incidence of concha bullosa was 47%. The presence of concha bullosa showed no statistically significant association with different patterns of chronic sinusitis.

journal_name

Eur Radiol

journal_title

European radiology

authors

Lam WW,Liang EY,Woo JK,Van Hasselt A,Metreweli C

doi

10.1007/BF00182491

subject

Has Abstract

pub_date

1996-01-01 00:00:00

pages

550-2

issue

4

eissn

0938-7994

issn

1432-1084

journal_volume

6

pub_type

杂志文章
  • The peritoneum, mesenteries and omenta: normal anatomy and pathological processes.

    abstract::The peritoneum is the largest and most complexly arranged serous membrane in the body. The potential peritoneal spaces, the peritoneal reflections forming peritoneal ligaments, mesenteries, omenta and the natural flow of peritoneal fluid determine the route of spread of intraperitoneal fluid and, consequently, disease...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050485

    authors: Healy JC,Reznek RH

    更新日期:1998-01-01 00:00:00

  • A pregnant lady with intermittent vaginal bleeding (2007: 3b). Placenta percreta.

    abstract::Placenta percreta is a potentially life-threatening complication of pregnancy, which is increasing in incidence. Ante-natal diagnosis with ultrasound and magnetic resonance imaging aids the obstetric team in planning further management. We present a case of placenta percreta with imaging and a brief review of the lite...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0498-5

    authors: Koo BC,Sala E,Hackett GA,Shaw AS

    更新日期:2007-06-01 00:00:00

  • Combined transcatheter arterial chemoembolization and percutaneous ethanol injection for the treatment of large hepatocellular carcinoma: local therapeutic effect and long-term survival rate.

    abstract::The aim of our study was to investigate local therapeutic effects and long-term results of combined transcatheter arterial chemoembolization (TACE) and percutaneous ethanol injection (PEI) in the treatment of large hepatocellular carcinoma (HCC). Eight-six patients (67 males and 19 females, age range 48-75 years, mean...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050409

    authors: Lencioni R,Paolicchi A,Moretti M,Pinto F,Armillotta N,Di Giulio M,Cicorelli A,Donati F,Cioni D,Bartolozzi C

    更新日期:1998-01-01 00:00:00

  • In vivo dentate nucleus MRI relaxometry correlates with previous administration of Gadolinium-based contrast agents.

    abstract:OBJECTIVES:To evaluate changes in T1 and T2* relaxometry of dentate nuclei (DN) with respect to the number of previous administrations of Gadolinium-based contrast agents (GBCA). METHODS:In 74 relapsing-remitting multiple sclerosis (RR-MS) patients with variable disease duration (9.8±6.8 years) and severity (Expanded ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4245-2

    authors: Tedeschi E,Palma G,Canna A,Cocozza S,Russo C,Borrelli P,Lanzillo R,Angelini V,Postiglione E,Morra VB,Salvatore M,Brunetti A,Quarantelli M

    更新日期:2016-12-01 00:00:00

  • Diffuse metastatic infiltration of a carcinoma into skeletal muscle.

    abstract::Skeletal muscle is one of the most unusual sites of metastasis from any malignancy. We report a patient with rapidly progressive contractures due to metastatic infiltration of a carcinoma of unknown origin into the skeletal muscle. This 61-year-old man presented with a 1-month history of rapidly evolving, painful rest...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050657

    authors: Hundt W,Braunschweig R,Reiser M

    更新日期:1999-01-01 00:00:00

  • Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose).

    abstract::In a controlled patient study we investigated the potential of attenuation-based on-line modulation of the tube current to reduce milliampere values (mAs) in CT examinations of children without loss of image quality. mAs can be reduced for non-circular patient cross sections without an increase in noise if tube curren...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1255-4

    authors: Greess H,Nömayr A,Wolf H,Baum U,Lell M,Böwing B,Kalender W,Bautz WA

    更新日期:2002-06-01 00:00:00

  • Microwave ablation plus chemotherapy versus chemotherapy in advanced non-small cell lung cancer: a multicenter, randomized, controlled, phase III clinical trial.

    abstract:OBJECTIVES:This prospective trial was performed to verify whether microwave ablation (MWA) in combination with chemotherapy could provide superior survival benefit compared with chemotherapy alone. MATERIALS AND METHODS:From March 1, 2015, to June 20, 2017, treatment-naïve patients with pathologically verified advance...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1007/s00330-019-06613-x

    authors: Wei Z,Yang X,Ye X,Feng Q,Xu Y,Zhang L,Sun W,Dong Y,Meng Q,Li T,Wang C,Li G,Zhang K,Li P,Bi J,Xue G,Sun Y,Sheng L,Liu B,Yu G,Ren H,Wang J,Sun L,Chen S,Geng D,Zhang B,Xu X,Zhang L,Sun D,Xu X,Diao

    更新日期:2020-05-01 00:00:00

  • Correction to: Patient dose reference levels in surgery: a multicenter study.

    abstract::The original version of this article, published on 01 August 2018, unfortunately contained two mistakes. ...

    journal_title:European radiology

    pub_type: 杂志文章,已发布勘误

    doi:10.1007/s00330-018-5713-7

    authors: Greffier J,Etard C,Mares O,Pereira F,Defez D,Duverger C,Branchereau P,Beregi JP,Coulomb R,Larbi A

    更新日期:2019-03-01 00:00:00

  • High rates of clinically relevant incidental findings by total-body CT scanning in trauma patients; results of the REACT-2 trial.

    abstract:OBJECTIVES:To determine whether there is a difference in frequency and clinical relevance of incidental findings detected by total-body computed tomography scanning (TBCT) compared to those by the standard work-up (STWU) with selective computed tomography (CT) scanning. METHODS:Trauma patients from five trauma centres...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1007/s00330-016-4598-6

    authors: Treskes K,Bos SA,Beenen LFM,Sierink JC,Edwards MJR,Beuker BJA,Muradin GSR,Hohmann J,Luitse JSK,Hollmann MW,Dijkgraaf MGW,Goslings JC,REACT-2 study group.

    更新日期:2017-06-01 00:00:00

  • Significance of hyperechoic marks observed during high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules.

    abstract:OBJECTIVE:To examine the association between the appearance of hyperechoic marks (HEMs) during high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules and nodule shrinkage at 6 months. METHODS:One hundred and thirty-six patients who underwent HIFU for benign thyroid nodule were analysed. An indepen...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5207-z

    authors: Lang BHH,Woo YC,Chiu KW

    更新日期:2018-06-01 00:00:00

  • Protocol modifications for CT perfusion (CTp) examinations of abdomen-pelvic tumors: impact on radiation dose and data processing time.

    abstract:PURPOSE:To evaluate the effect of CT perfusion (CTp) protocol modifications on quantitative perfusion parameters, radiation dose and data processing time. MATERIALS & METHODS:CTp datasets of 30 patients (21M:9F) with rectal (n = 24) or retroperitoneal (n = 6) tumours were studied. Standard CTp protocol included 50 sec...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-2048-4

    authors: Kambadakone AR,Sharma A,Catalano OA,Hahn PF,Sahani DV

    更新日期:2011-06-01 00:00:00

  • Comparison of complications between transjugular and axillosubclavian approach for placement of tunneled, central venous catheters in patients with hematological malignancy: a prospective study.

    abstract::This study was designed to compare the incidence of mechanical, thrombotic and infective complications in transjugular (IJV) and axillosubclavian (SCV) central venous catheters (CVC) in patients with hematological malignancy. In a prospective observational trial, 131 consecutive patients were classified into two group...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2641-0

    authors: Lee SH,Hahn ST

    更新日期:2005-06-01 00:00:00

  • Epidemiology of systematic reviews in imaging journals: evaluation of publication trends and sustainability?

    abstract:PURPOSE:To evaluate the epidemiology of systematic reviews (SRs) published in imaging journals. METHODS:A MEDLINE search identified SRs published in imaging journals from 1 January 2000-31 December 2016. Articles retrieved were screened against inclusion criteria. Demographic and methodological characteristics were ex...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5567-z

    authors: Alabousi M,Alabousi A,McGrath TA,Cobey KD,Budhram B,Frank RA,Nguyen F,Salameh JP,Dehmoobad Sharifabadi A,McInnes MDF

    更新日期:2019-02-01 00:00:00

  • Breath-hold MR imaging of focal liver lesions: comparison of fast and ultrasound techniques.

    abstract::The performance of breath-hold MR imaging using two T2-weighted hybrid sequences (TSE, TGSE), two T2-weighted single-shot sequences (HASTE, EPI-SE), and one T1-weighted gradient-echo sequence (FLASH) was compared with a standard conventional T2-weighted SE sequence in 20 patients with focal liver lesions. Liver signal...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00240685

    authors: Gaa J,Fischer H,Laub G,Georgi M

    更新日期:1996-01-01 00:00:00

  • Single-phase DECT with VNCT compared with three-phase CTU in patients with haematuria.

    abstract:OBJECTIVE:To retrospectively evaluate the diagnostic performance of single-phase dual-energy CT (DECT) with virtual non-contrast CT (VNCT) compared with three-phase CT urography (CTU) in patients with haematuria. METHODS:A total of 296 patients underwent three-phase CTU (NCT at 120 kVp; nephrographic phase and excreto...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4206-9

    authors: Park JJ,Park BK,Kim CK

    更新日期:2016-10-01 00:00:00

  • Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography.

    abstract::We assessed the effect of intra-coronary attenuation on diagnostic accuracy using 64-slice computed tomography coronary angiography (CT-CA). We enrolled 170 patients with suspected coronary artery disease who underwent conventional coronary angiography (CA) and 64-slice CT-CA (100 ml of Iomeprol 400 mg I/ml at 4 ml/s)...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0773-0

    authors: Cademartiri F,Maffei E,Palumbo AA,Malagò R,La Grutta L,Meiijboom WB,Aldrovandi A,Fusaro M,Vignali L,Menozzi A,Brambilla V,Coruzzi P,Midiri M,Kirchin MA,Mollet NR,Krestin GP

    更新日期:2008-03-01 00:00:00

  • Combined hepatocellular-cholangiocarcinoma: can we use contrast-enhanced ultrasound Liver Imaging Reporting and Data System (LI-RADS) to predict the patient's survival?

    abstract:OBJECTIVES:To evaluate the relationship between contrast-enhanced (CE) ultrasound Liver Reporting and Data System (LI-RADS) classification of combined hepatocellular-cholangiocarcinoma (cHCC-CCA) and their histopathological component predominance, and to determine if the CEUS LI-RADS category can be used to predict the...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07656-1

    authors: Yang J,Huang JY,Chen X,Ling WW,Luo Y,Shi YJ,Liu JB,Lu Q,Lyshchik A

    更新日期:2021-01-25 00:00:00

  • Ultrasound features of malignancy in the preoperative diagnosis of parathyroid cancer: a retrospective analysis of parathyroid tumours larger than 15 mm.

    abstract:OBJECTIVE:Nearly all reported parathyroid cancers are >15 mm at presentation. The objective was to identify ultrasound criteria of malignancy in parathyroid lesions of >15 mm in size. MATERIALS AND METHODS:This study was approved by a local ethics committee. A retrospective review of patients identified from a databas...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2141-3

    authors: Sidhu PS,Talat N,Patel P,Mulholland NJ,Schulte KM

    更新日期:2011-09-01 00:00:00

  • Coronary artery lumen volume index as a marker of flow-limiting atherosclerosis-validation against 13N-ammonia positron emission tomography.

    abstract:OBJECTIVES:Coronary artery volume indexed to left myocardial mass (CAVi), derived from coronary computed tomography angiography (CCTA), has been proposed as an indicator of diffuse atherosclerosis. We investigated the association of CAVi with quantitative flow parameters and its ability to predict ischemia as derived f...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07586-y

    authors: Benetos G,Benz DC,Rampidis GP,Giannopoulos AA,von Felten E,Bakula A,Sustar A,Fuchs TA,Pazhenkottil AP,Gebhard C,Kaufmann PA,Gräni C,Buechel RR

    更新日期:2021-01-16 00:00:00

  • Value of negative spiral CT angiography in patients with suspected acute PE: analysis of PE occurrence and outcome.

    abstract::The aim of this study was to analyze pulmonary embolism (PE) occurrence and retrospective clinical outcome in patients with clinically suspected acute PE and a negative spiral CT angiography (SCTA) of the pulmonary arteries. Within a 35-month period, 485 consecutive patients with clinical symptoms of acute PE underwen...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-2016-3

    authors: Krestan CR,Klein N,Fleischmann D,Kaneider A,Novotny C,Kreuzer S,Riedl C,Minar E,Janata K,Herold CJ

    更新日期:2004-01-01 00:00:00

  • Practical applications of deep learning: classifying the most common categories of plain radiographs in a PACS using a neural network.

    abstract:OBJECTIVES:The goal of the present study was to classify the most common types of plain radiographs using a neural network and to validate the network's performance on internal and external data. Such a network could help improve various radiological workflows. METHODS:All radiographs from the year 2017 (n = 71,274) a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07241-6

    authors: Dratsch T,Korenkov M,Zopfs D,Brodehl S,Baessler B,Giese D,Brinkmann S,Maintz D,Pinto Dos Santos D

    更新日期:2020-09-28 00:00:00

  • Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results.

    abstract::An electromagnetic-based tracking and navigation system was evaluated for interventional radiology. The electromagnetic tracking system (CAPPA IRAD EMT, CASinnovations, Erlangen, Germany) was used for real-time monitoring of punctures of the lumbar facet joints and intervertebral disks in a spine phantom, three pig ca...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1227-z

    authors: Bruners P,Penzkofer T,Nagel M,Elfring R,Gronloh N,Schmitz-Rode T,Günther RW,Mahnken AH

    更新日期:2009-04-01 00:00:00

  • Agenesis of the horizontal segment of the left portal vein demonstrated by magnetic resonance imaging including phase-contrast magnetic resonance venography.

    abstract::Two cases of agenesis of the horizontal segment of the left portal vein are reported. This very rare vascular anomaly probably corresponds to an embryological variation rather than to an obstruction of the left portal vein. In almost all cases liver ultrasonography is sufficient for identifying such vascular abnormali...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050057

    authors: Chevallier P,Oddo F,Baldini E,Peten EP,Diaine B,Padovani B

    更新日期:2000-01-01 00:00:00

  • Intra-articular ganglion cysts of the cruciate ligaments.

    abstract::Intra-articular ganglion cysts of the cruciate ligaments are associated with non-specific clinical signs and symptoms. Familiarity with the MR appearances in particular is important to make an accurate diagnosis, exclude associated abnormalities, and avoid misdiagnosis. ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003309900290

    authors: Tyrrell PN,Cassar-Pullicino VN,McCall IW

    更新日期:2000-01-01 00:00:00

  • Secondary aortoenteric fistula: active bleeding detected with multi-detector-row CT.

    abstract::We report a case of active bleeding of a secondary aortoenteric fistula (SAEF), in which CT angiography with multi-detector-row CT (MDCT) was finally diagnostic after negative catheter angiography and unsatisfactory endoscopy. The MDCT angiography clearly demonstrated the fistulous tract between the abdominal aortic g...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1534-8

    authors: Roos JE,Willmann JK,Hilfiker PR

    更新日期:2002-12-01 00:00:00

  • New sonographic imaging observations in focal pancreatitis.

    abstract::The imaging findings that ultrasonographically differentiate focal acute pancreatitis (FAP) from a malignant lesion of the pancreas are described. Focal acute pancreatitis is ultrasonographically (US) characterized as a hypoechoic, homogeneous, localized, subsegmental, non-expansive and diffusely demarcated lesion loc...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050756

    authors: Lorén I,Lasson A,Fork T,Genell S,Nilsson A,Nilsson P,Nirhov N

    更新日期:1999-01-01 00:00:00

  • Seminal vesicle invasion in prostate cancer: prediction with combined T2-weighted and diffusion-weighted MR imaging.

    abstract::The aim of this study was to evaluate the usefulness of diffusion-weighted imaging (DWI) in detecting seminal vesicle invasion (SVI). A total of 283 patients underwent conventional MRI and DWI before prostate cancer surgery. The apparent diffusion coefficient (ADC) values of all PCa foci, SVI and seminal vesicle were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1428-0

    authors: Ren J,Huan Y,Wang H,Ge Y,Chang Y,Yin H,Sun L

    更新日期:2009-10-01 00:00:00

  • A deep learning approach to characterize 2019 coronavirus disease (COVID-19) pneumonia in chest CT images.

    abstract:OBJECTIVES:To utilize a deep learning model for automatic detection of abnormalities in chest CT images from COVID-19 patients and compare its quantitative determination performance with radiological residents. METHODS:A deep learning algorithm consisted of lesion detection, segmentation, and location was trained and ...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-020-07044-9

    authors: Ni Q,Sun ZY,Qi L,Chen W,Yang Y,Wang L,Zhang X,Yang L,Fang Y,Xing Z,Zhou Z,Yu Y,Lu GM,Zhang LJ

    更新日期:2020-12-01 00:00:00

  • Interventional radiology in the management of complications after liver transplantation.

    abstract::The arrival of new surgical transplantation techniques, such as split living donor or auxiliary liver transplantation, have increased the incidence of vascular and biliary complications. The causes, symptoms, and diagnostic modalities of arterial, portal caval, and biliary complications are detailed. Interventional te...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-003-2196-x

    authors: Denys A,Chevallier P,Doenz F,Qanadli SD,Sommacale D,Gillet M,Schnyder P,Bessoud B

    更新日期:2004-03-01 00:00:00

  • Automatic determination of minimal cardiac motion phases for computed tomography imaging: initial experience.

    abstract::Low motion phases for cardiac computed tomography reconstructions are currently detected manually in a user-dependent selection process which is often time consuming and suboptimal. The concept of motion maps was recently introduced to achieve automatic phase selection. This pilot study compared the accuracy of motion...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2849-z

    authors: Hoffmann MH,Lessick J,Manzke R,Schmid FT,Gershin E,Boll DT,Rispler S,Aschoff AJ,Grass M

    更新日期:2006-02-01 00:00:00