Smart chest X-ray worklist prioritization using artificial intelligence: a clinical workflow simulation.

Abstract:

OBJECTIVE:The aim is to evaluate whether smart worklist prioritization by artificial intelligence (AI) can optimize the radiology workflow and reduce report turnaround times (RTATs) for critical findings in chest radiographs (CXRs). Furthermore, we investigate a method to counteract the effect of false negative predictions by AI-resulting in an extremely and dangerously long RTAT, as CXRs are sorted to the end of the worklist. METHODS:We developed a simulation framework that models the current workflow at a university hospital by incorporating hospital-specific CXR generation rates and reporting rates and pathology distribution. Using this, we simulated the standard worklist processing "first-in, first-out" (FIFO) and compared it with a worklist prioritization based on urgency. Examination prioritization was performed by the AI, classifying eight different pathological findings ranked in descending order of urgency: pneumothorax, pleural effusion, infiltrate, congestion, atelectasis, cardiomegaly, mass, and foreign object. Furthermore, we introduced an upper limit for the maximum waiting time, after which the highest urgency is assigned to the examination. RESULTS:The average RTAT for all critical findings was significantly reduced in all prioritization simulations compared to the FIFO simulation (e.g., pneumothorax: 35.6 min vs. 80.1 min; p < 0.0001), while the maximum RTAT for most findings increased at the same time (e.g., pneumothorax: 1293 min vs 890 min; p < 0.0001). Our "upper limit" substantially reduced the maximum RTAT in all classes (e.g., pneumothorax: 979 min vs. 1293 min/1178 min; p < 0.0001). CONCLUSION:Our simulations demonstrate that smart worklist prioritization by AI can reduce the average RTAT for critical findings in CXRs while maintaining a small maximum RTAT as FIFO. KEY POINTS:• Development of a realistic clinical workflow simulator based on empirical data from a hospital allowed precise assessment of smart worklist prioritization using artificial intelligence. • Employing a smart worklist prioritization without a threshold for maximum waiting time runs the risk of false negative predictions of the artificial intelligence greatly increasing the report turnaround time. • Use of a state-of-the-art convolution neural network can reduce the average report turnaround time almost to the upper limit of a perfect classification algorithm (e.g., pneumothorax: 35.6 min vs. 30.4 min).

journal_name

Eur Radiol

journal_title

European radiology

authors

Baltruschat I,Steinmeister L,Nickisch H,Saalbach A,Grass M,Adam G,Knopp T,Ittrich H

doi

10.1007/s00330-020-07480-7

subject

Has Abstract

pub_date

2020-11-21 00:00:00

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-020-07480-7

pub_type

杂志文章
  • Validation of the Ottawa knee rules in an emergency teaching centre.

    abstract::Our objective was to determine the value of the Ottawa knee rules when applied by users with different levels of clinical training. We used a prospective patient survey by the medical students and surgery residents of a European university trauma centre. The study group consisted of 261 eligible patients who presented...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1198-9

    authors: Ketelslegers E,Collard X,Vande Berg B,Danse E,El-Gariani A,Poilvache P,Maldague B

    更新日期:2002-05-01 00:00:00

  • Intrahepatic dynamic contrast MR lymphangiography: initial experience with a new technique for the assessment of liver lymphatics.

    abstract:OBJECTIVES:To describe the technique and report on our initial experience with the use of intrahepatic dynamic contrast magnetic resonance lymphangiography (IH-DCMRL) for evaluation of the lymphatics in patients with hepatic lymphatic flow disorders. METHODS:This is a retrospective review of the imaging and clinical f...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06112-z

    authors: Biko DM,Smith CL,Otero HJ,Saul D,White AM,DeWitt A,Glatz AC,Piccoli DA,Mamula P,Rome JJ,Dori Y

    更新日期:2019-10-01 00:00:00

  • Probability of malignancy for lesions detected on breast MRI: a predictive model incorporating BI-RADS imaging features and patient characteristics.

    abstract:OBJECTIVES:To predict the probability of malignancy for MRI-detected breast lesions with a multivariate model incorporating patient and lesion characteristics. METHODS:Retrospective review of 2565 breast MR examinations from 1/03-11/06. BI-RADS 3, 4 and 5 lesions initially detected on MRI for new cancer or high-risk s...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2094-6

    authors: Demartini WB,Kurland BF,Gutierrez RL,Blackmore CC,Peacock S,Lehman CD

    更新日期:2011-08-01 00:00:00

  • Use of dual-energy CT for renal mass assessment.

    abstract::Although dual-energy CT (DECT) may prove useful in a variety of abdominal imaging tasks, renal mass evaluation represents the area where this technology can be most impactful in abdominal imaging compared to routinely performed contrast-enhanced-only single-energy CT exams. DECT post-processing techniques, such as cre...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-020-07426-z

    authors: Thiravit S,Brunnquell C,Cai LM,Flemon M,Mileto A

    更新日期:2020-11-18 00:00:00

  • Ultrasound-guided core-needle biopsy of the testis for focal indeterminate intratesticular lesions.

    abstract::The aim of this study was to evaluate ultrasound (US)-guided core-needle testicular biopsy. Twelve biopsies were performed in eleven patients, under US guidance using disposable 16- or 18-gauge needles, between April 2003 and October 2006. Details were entered on a database and records reviewed 9 months to 3 years aft...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1072-0

    authors: Soh E,Berman LH,Grant JW,Bullock N,Williams MV

    更新日期:2008-12-01 00:00:00

  • Cystic form of paraduodenal pancreatitis (cystic dystrophy in heterotopic pancreas (CDHP)): a potential link with minor papilla abnormalities? A study in a large series.

    abstract:OBJECTIVES:To analyze the association between cystic dystrophy in the heterotopic pancreas (CDHP) and minor papilla abnormalities. MATERIAL AND METHODS:Seventy-six patients with CDHP were retrospectively included over 14 years. Two radiologists searched for MDCT signs of CDHP (cysts and thickened intestinal wall, infl...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3799-8

    authors: Wagner M,Vullierme MP,Rebours V,Ronot M,Ruszniewski P,Vilgrain V

    更新日期:2016-01-01 00:00:00

  • Thoracic complications in uremic patients and in patients undergoing dialytic treatment: state of the art.

    abstract::No organ in the chest is spared the negative effects of uremia. The dialytic treatment itself is often associated with a large array of thoracic complications. We review the main thoracic manifestations of the terminal uremia from the radiological point of view, such as: uremic pleuritis and pericarditis, uremic pneum...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/BF02742931

    authors: Gavelli G,Zompatori M

    更新日期:1997-01-01 00:00:00

  • Early diffuse recurrence of hepatocellular carcinoma after percutaneous radiofrequency ablation: analysis of risk factors.

    abstract:OBJECTIVE:To evaluate the risk factors affecting early diffuse recurrence within 1 year of percutaneous ultrasound-guided radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC). METHODS:Out of 146 patients who received transcatheter arterial chemoembolisation (TACE) for treatment of recurrent HCC after percu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2561-8

    authors: Lee HY,Rhim H,Lee MW,Kim YS,Choi D,Park MJ,Kim YK,Kim SH,Lim HK

    更新日期:2013-01-01 00:00:00

  • Double-dose 1.0-M gadobutrol versus standard-dose 0.5-M gadopentetate dimeglumine in revealing small hypervascular hepatocellular carcinomas.

    abstract::The purpose of this study was to compare the diagnostic efficacy of double-dose 1.0-M gadobutrol with that of standard-dose 0.5-M gadopentetate dimeglumine for revealing small hypervascular hepatocellular carcinomas (HCCs). Twenty-three patients with 37 HCCs (mean size: 1.2 cm) that were diagnosed by histology (n = 13...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0630-1

    authors: Kim YK,Lee YH,Kim CS,Han YM,Hwang SB

    更新日期:2008-01-01 00:00:00

  • Radiological features of the visceral and skeletal involvement of hemochromatosis.

    abstract::Hemochromatosis is a multisystem disorder produced by the excessive accumulation of iron in visceral organs and the musculoskeletal system. Clinically the disease may be silent, but characteristic radiological features may point to the diagnosis. The increased iron stores in the organs involved, especially in the live...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050274

    authors: Jäger HJ,Mehring U,Götz GF,Neise M,Erlemann R,Kapp HJ,Mathias KD

    更新日期:1997-01-01 00:00:00

  • Native T1 mapping compared to ultrasound elastography for staging and monitoring liver fibrosis: an animal study of repeatability, reproducibility, and accuracy.

    abstract:OBJECTIVES:To investigate the repeatability, reproducibility, and staging and monitoring of the performance of native T1 mapping for noninvasively assessing liver fibrosis in comparison with acoustic radiation force impulse (ARFI) elastography. METHODS:The repeatability and reproducibility were explored in 8 male Spra...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06335-0

    authors: Li J,Liu H,Zhang C,Yang S,Wang Y,Chen W,Li X,Wang D

    更新日期:2020-01-01 00:00:00

  • Non-traumatic thoracic emergencies: imaging and treatment of thoracic fluid collections (including pneumothorax).

    abstract::Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-002-1512-1

    authors: Ellis JR,Gleeson FV

    更新日期:2002-08-01 00:00:00

  • Contrast-enhanced ultrasonography and spiral computed tomography in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma.

    abstract::The aim was to compare the performances of contrast-enhanced (CE) ultrasonography (US) and spiral computed tomography (CT) in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma (HCC). We studied 50 patients with HCC who had biopsy-proven portal vein thrombi that had been...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0931-z

    authors: Rossi S,Ghittoni G,Ravetta V,Torello Viera F,Rosa L,Serassi M,Scabini M,Vercelli A,Tinelli C,Dal Bello B,Burns PN,Calliada F

    更新日期:2008-08-01 00:00:00

  • Imaging of tuberculous disease involving breast.

    abstract::The aim of our study was to evaluate radiologic findings of the tuberculosis involving breast. We evaluated the radiologic features of 17 patients (18 lesions) with tuberculous disease involving the breast. The radiologic examinations, including mammography (16 patients), ultrasonography (12 patients), and Gd-DTPA-enh...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050578

    authors: Oh KK,Kim JH,Kook SH

    更新日期:1998-01-01 00:00:00

  • Acquisition time, radiation dose, subjective and objective image quality of dual-source CT scanners in acute pulmonary embolism: a comparative study.

    abstract:OBJECTIVES:To compare the scan acquisition time, radiation dose, subjective and objective image quality of two dual-source CT scanners (DSCT) for detection of acute pulmonary embolism. METHODS:Two hundred twenty-one scans performed on the 2nd-generation DSCT and 354 scans on the 3rd-generation DSCT were included in th...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06650-6

    authors: Abdellatif W,Esslinger E,Kobes K,Wong A,Powell J,Ali IT,Andrews G,Nicolaou S

    更新日期:2020-05-01 00:00:00

  • Structural changes induced by antineoplastic therapies: keys to evaluate tumor response to treatment.

    abstract::The criteria to define therapeutic response in oncology are those proposed by Miller, characterized by four response categories (complete response, partial response, no change, progression of disease), and based upon both measurable and non-measurable (and otherwise assessable) morphological parameters in comparison w...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300101074

    authors: Ferrozzi F,Tognini G,Pavone P

    更新日期:2002-04-01 00:00:00

  • Dynamic MR imaging of osteoid osteomas: correlation of semiquantitative and quantitative perfusion parameters with patient symptoms and treatment outcome.

    abstract:OBJECTIVE:To evaluate the relationship between multiple MR perfusion parameters and symptoms of patients with osteoid osteomas after percutaneous laser therapy. METHODS:MR perfusion studies of 20 patients diagnosed with an osteoid osteoma, treated with CT-guided percutaneous laser therapy, were retrospectively evaluat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2867-1

    authors: Teixeira PA,Chanson A,Beaumont M,Lecocq S,Louis M,Marie B,Sirveaux F,Blum A

    更新日期:2013-09-01 00:00:00

  • Distributed nuclear medicine applications using World Wide Web and Java technology.

    abstract::At present, medical applications applying World Wide Web (WWW) technology are mainly used to view static images and to retrieve some information. The Java platform is a relative new way of computing, especially designed for network computing and distributed applications which enables interactive connection between use...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000432

    authors: Knoll P,Höll K,Mirzaei S,Koriska K,Köhn H

    更新日期:2000-01-01 00:00:00

  • An analysis of factors associated with increased fluoroscopy time or the need for complex techniques at IVC filter retrieval.

    abstract:OBJECTIVES:To evaluate factors associated with increased fluoroscopy time or the need for complex techniques at IVC filter retrieval. METHODS:This is a single-institution retrospective cohort study of 187 consecutive patients who underwent IVC filter retrieval. An analysis was performed on associations of patient fact...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5766-7

    authors: Kleedehn M,Moore K,Longo K,Woo K,Laeseke P

    更新日期:2019-04-01 00:00:00

  • MR-guided liver tumor ablation employing open high-field 1.0T MRI for image-guided brachytherapy.

    abstract:OBJECTIVE:To determine the feasibility and safety of image-guided brachytherapy employing a modified open high-field MR system. METHODS:This is a follow-up study of a development project enabling technologies for interventional use of 1.0T open MRI. Modifications included coils and in-bore visualization, fluoroscopic ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1751-5

    authors: Ricke J,Thormann M,Ludewig M,Jungnickel K,Grosser O,Wybranski C,Peters N,Hass P,Bunke J,Fischbach F

    更新日期:2010-08-01 00:00:00

  • Macroscopic heterogeneity of liver fat: an MR-based study in type-2 diabetic patients.

    abstract:OBJECTIVE:To assess the heterogeneity of liver fat deposition with MR of the liver in type-2 diabetic (T2D) patients. METHODS:We enrolled 121 consecutive T2D patients. The reference standard was 3.0-T (1)H-MR spectroscopy. Hepatic steatosis was defined as liver fat content (LFC) ≥5.56 %. A triple-echo gradient-echo se...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2468-4

    authors: Capitan V,Petit JM,Aho S,Lefevre PH,Favelier S,Loffroy R,Hillon P,Krausé D,Cercueil JP,Guiu B

    更新日期:2012-10-01 00:00:00

  • Meniscal body extrusion and cartilage coverage in middle-aged and elderly without radiographic knee osteoarthritis.

    abstract:OBJECTIVES:To determine meniscal extrusion and cartilage coverage on magnetic resonance (MR) images and factors associated with these parameters in knees of middle-aged and elderly persons free from radiographic tibiofemoral osteoarthritis (OA). METHODS:Seven hundred eighteen persons, free of radiographic tibiofemoral...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5741-3

    authors: Svensson F,Felson DT,Zhang F,Guermazi A,Roemer FW,Niu J,Aliabadi P,Neogi T,Englund M

    更新日期:2019-04-01 00:00:00

  • Three-dimensional true FISP for high-resolution imaging of the whole brain.

    abstract::While high-resolution T1-weighted sequences, such as three-dimensional magnetization-prepared rapid gradient-echo imaging, are widely available, there is a lack of an equivalent fast high-resolution sequence providing T2 contrast. Using fast high-performance gradient systems we show the feasibility of three-dimensiona...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-1846-3

    authors: Schmitz B,Hagen T,Reith W

    更新日期:2003-07-01 00:00:00

  • Impact of high resolution 3 tesla MR neurography (MRN) on diagnostic thinking and therapeutic patient management.

    abstract:OBJECTIVE:To evaluate the impact of magnetic resonance neurography (MRN) on diagnostic thinking and therapeutic choices in patients with suspected peripheral neuropathy. METHODS:IRB approval was obtained for this HIPAA-compliant study. Questionnaires were administered to six surgeons regarding the diagnosis and treatm...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3958-y

    authors: Chhabra A,Belzberg AJ,Rosson GD,Thawait GK,Chalian M,Farahani SJ,Shores JT,Deune G,Hashemi S,Thawait SK,Subhawong TK,Carrino JA

    更新日期:2016-05-01 00:00:00

  • Dose and image quality in the comparison of analogue and digital techniques in paediatric urology examinations.

    abstract::In paediatric radiology it has been recognised that children have a higher risk of developing cancer from the irradiation than adults (two to three times); therefore, increased attention has been directed towards the dose to the patient. In this study the effect on patient dose and image quality in replacing the expos...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-003-2144-9

    authors: Persliden J,Helmrot E,Hjort P,Resjö M

    更新日期:2004-04-01 00:00:00

  • Repositioning of malpositioned or flipped central venous catheters.

    abstract::Primary misplaced or secondary flipped implanted catheters are located mostly in the right jugular vein. We demonstrate an effective method to replace fix implanted catheters such as Ports, Grochomg or Hickman catheters. Using a femoral venous approach, replacement into the superior vena cava can easily be done with a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1151-y

    authors: Thalhammer A,Jacobi V,Balzer J,Vogl TJ

    更新日期:2002-03-01 00:00:00

  • Local staging of rectal cancer: the current role of MRI.

    abstract::With the advent of powerful gradient coil systems and high-resolution surface coils, magnetic resonance imaging (MRI) has recently extended its role in the staging of rectal cancer. MRI is superior to endorectal ultrasound, the most widely used staging modality in patients with rectal tumors, in that it visualizes not...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-006-0388-x

    authors: Klessen C,Rogalla P,Taupitz M

    更新日期:2007-02-01 00:00:00

  • Zone-specific logistic regression models improve classification of prostate cancer on multi-parametric MRI.

    abstract:OBJECTIVES:To assess the interchangeability of zone-specific (peripheral-zone (PZ) and transition-zone (TZ)) multiparametric-MRI (mp-MRI) logistic-regression (LR) models for classification of prostate cancer. METHODS:Two hundred and thirty-one patients (70 TZ training-cohort; 76 PZ training-cohort; 85 TZ temporal vali...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3636-0

    authors: Dikaios N,Alkalbani J,Abd-Alazeez M,Sidhu HS,Kirkham A,Ahmed HU,Emberton M,Freeman A,Halligan S,Taylor S,Atkinson D,Punwani S

    更新日期:2015-09-01 00:00:00

  • Development and prospective validation of a novel weighted quantitative scoring system aimed at predicting the pathological features of cystic renal masses.

    abstract:OBJECTIVES:To develop and prospectively validate a novel weighted quantitative scoring system based on CT findings, namely, the renal cyst index (RCI), aimed at preoperatively predicting the pathological features of cystic renal masses (CRMs). METHODS:The RCI was based on four critical features of CRMs: the cyst wall,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5722-6

    authors: Li Y,Dai C,Bian T,Zhou J,Xiang Z,He M,Huang J,Zhu Y,Hu X,Jiang S,Guo J,Wang H

    更新日期:2019-04-01 00:00:00

  • The effect of tube voltage combination on image artefact and radiation dose in dual-source dual-energy CT: comparison between conventional 80/140 kV and 80/150 kV plus tin filter for gout protocol.

    abstract:OBJECTIVES:In dual-source CT, dual-energy (DE) performance is affected by various X-ray tube voltage combinations with and without tin filter (Sn). The purpose of this study was to assess the utility of the 80/150 Sn kV voltage combination in terms of image artefact and radiation dose for DECT gout protocol, compared w...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5622-9

    authors: Jeon JY,Lee SW,Jeong YM,Baek HJ

    更新日期:2019-03-01 00:00:00