Native T1 mapping compared to ultrasound elastography for staging and monitoring liver fibrosis: an animal study of repeatability, reproducibility, and accuracy.

Abstract:

OBJECTIVES:To investigate the repeatability, reproducibility, and staging and monitoring of the performance of native T1 mapping for noninvasively assessing liver fibrosis in comparison with acoustic radiation force impulse (ARFI) elastography. METHODS:The repeatability and reproducibility were explored in 8 male Sprague-Dawley rats with intraclass correlation coefficient (ICC). Different degrees of fibrosis were induced in 52 rats by carbon-tetrachloride (CCl4) insult. Another 16 rats were used to build fibrosis progression and regression models. The native T1 values and shear wave velocity (SWV) were quantified by using native T1 mapping and ARFI elastography, respectively. The METAVIR system (F0-F4) was used for the staging of fibrosis. The area under the receiver operating characteristic curve (AUC) was determined to assess the performance of quantitative parameters for staging and monitoring fibrosis. RESULTS:Native T1 values shared similar good repeatability (ICC = 0.93) and reproducibility (ICC = 0.87) with SWV (ICC = 0.84-0.93). The AUC of native T1 values were 0.84, 0.84, and 0.75 for diagnosing significant fibrosis (≥ F2) and liver cirrhosis (F4) and detecting fibrosis progression, and those of SWV were 0.81, 0.86, and 0.7, respectively. No significant difference in performance was found between the two quantitative parameters (p ≥ 0.496). For detecting fibrosis regression, native T1 values had a better accuracy (AUC = 0.99) than SWV (AUC = 0.56; p = 0.002). CONCLUSION:Native T1 mapping may be a reliable and accurate method for noninvasively assessing liver fibrosis. Compared with ARFI elastography, it provides similar good repeatability and reproducibility, a similar high accuracy for staging fibrosis, and a better accuracy for detecting fibrosis regression. KEY POINTS:• Native T1 mapping is a valuable tool for noninvasively assessing liver fibrosis and can be measured on virtually all clinical MRI machines without additional hardware or gadolinium chelate injection. • Compared with acoustic radiation force impulse elastography, native T1 mapping yields similar good repeatability and reproducibility and a similar high accuracy for staging fibrosis. • Native T1 mapping provides a significantly better performance for detecting fibrosis regression than acoustic radiation force impulse elastography.

journal_name

Eur Radiol

journal_title

European radiology

authors

Li J,Liu H,Zhang C,Yang S,Wang Y,Chen W,Li X,Wang D

doi

10.1007/s00330-019-06335-0

subject

Has Abstract

pub_date

2020-01-01 00:00:00

pages

337-345

issue

1

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-019-06335-0

journal_volume

30

pub_type

杂志文章
  • Effective dose in Albanian direct chest fluoroscopy.

    abstract::In the absence of reliable supplies of X-ray film, direct fluoroscopy is still extensively used in Albania, with chest radiology a particularly common application. This paper aims to quantify both patient skin dose and the risk-related quantity effective dose for direct fluoroscopy units based in seven different Alban...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000462

    authors: Marshall NW,Shehu G,Marsh D,Faulkner K,Malone J,Dewhurst K

    更新日期:2001-01-01 00:00:00

  • Protocol modifications for CT perfusion (CTp) examinations of abdomen-pelvic tumors: impact on radiation dose and data processing time.

    abstract:PURPOSE:To evaluate the effect of CT perfusion (CTp) protocol modifications on quantitative perfusion parameters, radiation dose and data processing time. MATERIALS & METHODS:CTp datasets of 30 patients (21M:9F) with rectal (n = 24) or retroperitoneal (n = 6) tumours were studied. Standard CTp protocol included 50 sec...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-2048-4

    authors: Kambadakone AR,Sharma A,Catalano OA,Hahn PF,Sahani DV

    更新日期:2011-06-01 00:00:00

  • Late gadolinium enhancement cardiac imaging on a 3T scanner with parallel RF transmission technique: prospective comparison of 3D-PSIR and 3D-IR.

    abstract:OBJECTIVE:To qualitatively and quantitatively compare different late gadolinium enhancement (LGE) sequences acquired at 3T with a parallel RF transmission technique. METHODS:One hundred and sixty participants prospectively enrolled underwent a 3T cardiac MRI with 3 different LGE sequences: 3D Phase-Sensitive Inversion...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4002-y

    authors: Schultz A,Caspar T,Schaeffer M,Labani A,Jeung MY,El Ghannudi S,Roy C,Ohana M

    更新日期:2016-06-01 00:00:00

  • Quantitative CT texture and shape analysis: can it differentiate benign and malignant mediastinal lymph nodes in patients with primary lung cancer?

    abstract:OBJECTIVE:To assess the accuracy of CT texture and shape analysis in the differentiation of benign and malignant mediastinal nodes in lung cancer. METHODS:Forty-three patients with biopsy-proven primary lung malignancy with pathological mediastinal nodal staging and unenhanced CT of the thorax were studied retrospecti...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3420-6

    authors: Bayanati H,E Thornhill R,Souza CA,Sethi-Virmani V,Gupta A,Maziak D,Amjadi K,Dennie C

    更新日期:2015-02-01 00:00:00

  • Assessment of acute kidney injury with T1 mapping MRI following solid organ transplantation.

    abstract:OBJECTIVES:To evaluate T1 mapping as a non-invasive, functional MRI biomarker in patients shortly after solid organ transplantation to detect acute postsurgical kidney damage and to correlate T1 times with renal function. METHODS:101 patients within 2 weeks after solid organ transplantation (49 kidney transplantation,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4943-4

    authors: Peperhove M,Vo Chieu VD,Jang MS,Gutberlet M,Hartung D,Tewes S,Warnecke G,Fegbeutel C,Haverich A,Gwinner W,Lehner F,Bräsen JH,Haller H,Wacker F,Gueler F,Hueper K

    更新日期:2018-01-01 00:00:00

  • Correction to: Anatomy of the retro-oesophageal major aortopulmonary collateral arteries in patients with pulmonary atresia with ventricular septal defect: results from preoperative CTA.

    abstract::The original version of this article, originally published online ahead of printing on January 05, 2018, unfortunately contained mistakes. ...

    journal_title:European radiology

    pub_type: 杂志文章,已发布勘误

    doi:10.1007/s00330-018-5471-6

    authors: Jia Q,Cen J,Li J,Zhuang J,Liu H,Zhang Q,Liu X,Huang M,Liang C

    更新日期:2018-10-01 00:00:00

  • Diagnostic values of 68Ga-labelled DOTANOC PET/CT imaging in pediatric patients presenting with paraneoplastic opsoclonus myoclonus ataxia syndrome.

    abstract:OBJECTIVES:Opsoclonus myoclonus ataxia (OMA) syndrome, also known as "Kinsbourne syndrome" or "dancing eye syndrome," is a rare, paraneoplastic entity which may be associated with pediatric neuroblastic tumors and carry a grave prognosis. We aimed to evaluate the role of 68Ga DOTANOC PET/CT for detecting neuroblastic t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07587-x

    authors: Kumar R,Vankadari K,Mittal BR,Bansal D,Trehan A,Sahu JK,Sankhyan N

    更新日期:2021-01-06 00:00:00

  • Non-traumatic abdominal emergencies: imaging and intervention in acute biliary conditions.

    abstract::Imaging is the standard method for the evaluation of emergency bile ducts and gallbladder diseases. Imaging may help to treat the patient also. In acute cholecystitis, association of clinical and sonographic data is accurate for the diagnosis, even when the patient is examined by a junior radiologist. Computed tomogra...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-002-1613-x

    authors: Menu Y,Vuillerme MP

    更新日期:2002-10-01 00:00:00

  • Practical applications of deep learning: classifying the most common categories of plain radiographs in a PACS using a neural network.

    abstract:OBJECTIVES:The goal of the present study was to classify the most common types of plain radiographs using a neural network and to validate the network's performance on internal and external data. Such a network could help improve various radiological workflows. METHODS:All radiographs from the year 2017 (n = 71,274) a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07241-6

    authors: Dratsch T,Korenkov M,Zopfs D,Brodehl S,Baessler B,Giese D,Brinkmann S,Maintz D,Pinto Dos Santos D

    更新日期:2020-09-28 00:00:00

  • Carcinoid tumours: predicting the location of the primary neoplasm based on the sites of metastases.

    abstract:OBJECTIVES:To predict the primary neuroendocrine tumour of the gastrointestinal tract site based on observed metastatic sites. METHODS:We studied data from the radiology database of a single, large cancer centre on 250 patients with pathologically confirmed neuroendocrine tumours. Primary tumour sites and the location...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2615-y

    authors: Bhosale P,Shah A,Wei W,Varadhachary G,Johnson V,Shah V,Kundra V

    更新日期:2013-02-01 00:00:00

  • The value of apparent diffusion coefficient in the assessment of cervical cancer.

    abstract:OBJECTIVES:To evaluate the potential value of apparent diffusion coefficient (ADC) measurement in the assessment of cervical cancer. METHODS:One hundred twelve patients with cervical cancer and 67 control subjects underwent diffusion-weighted imaging (DWI) in addition to routine MR imaging at 3.0-T MRI before therapy....

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2681-1

    authors: Kuang F,Ren J,Zhong Q,Liyuan F,Huan Y,Chen Z

    更新日期:2013-04-01 00:00:00

  • Presinusoidal portal hypertension does not affect hepatic artery resistance index.

    abstract::We aimed to determine the mean hepatic artery resistance index (RI) in presinusoidal portal hypertension and to compare the values with those in sinusoidal portal hypertension. The hepatic artery RIs of 11 patients with presinusoidal portal hypertension, 12 patients with sinusoidal portal hypertension and 16 healthy s...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050806

    authors: Erden A,Altuntaş B,Olçer T,Cumhur T

    更新日期:1999-01-01 00:00:00

  • Prediction for steatosis in type-2 diabetes: clinico-biological markers versus 1H-MR spectroscopy.

    abstract:OBJECTIVES:The SteatoTest, fatty liver index (FLI) and hepatic steatosis index (HSI) are clinico-biological scores of steatosis validated in general or selected populations. Serum adiponectin (s-adiponectin) and retinol binding protein 4 (s-RBP4) are adipokines that could predict liver steatosis. We investigated whethe...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2326-9

    authors: Guiu B,Crevisy-Girod E,Binquet C,Duvillard L,Masson D,Lepage C,Hamza S,Krausé D,Verges B,Minello A,Cercueil JP,Hillon P,Petit JM

    更新日期:2012-04-01 00:00:00

  • Contrast-enhanced cone beam breast CT features of breast cancers: correlation with immunohistochemical receptors and molecular subtypes.

    abstract:OBJECTIVES:To investigate the association of contrast-enhanced cone beam breast CT (CE-CBBCT) features, immunohistochemical (IHC) receptors, and molecular subtypes in breast cancer. METHODS:In this retrospective study, patients who underwent preoperative CE-CBBCT and received complete IHC results were analyzed. CE-CBB...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07277-8

    authors: Ma Y,Liu A,O'Connell AM,Zhu Y,Li H,Han P,Yin L,Lu H,Ye Z

    更新日期:2020-10-02 00:00:00

  • Coronavirus disease 2019 (COVID-19) imaging reporting and data system (COVID-RADS) and common lexicon: a proposal based on the imaging data of 37 studies.

    abstract:BACKGROUND:In the vast majority of the laboratory-confirmed coronavirus disease 2019 (COVID-19) patients, computed tomography (CT) examinations yield a typical pattern and the sensitivity of this modality has been reported to be 97% in a large-scale study. Structured reporting systems simplify the interpretation and re...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06863-0

    authors: Salehi S,Abedi A,Balakrishnan S,Gholamrezanezhad A

    更新日期:2020-09-01 00:00:00

  • Hemolytic effect of deformed intra-arterial stents and stent grafts in vitro.

    abstract::Our objective was to evaluate the hemolytic effect of stents and stent grafts in an in vitro flow model. The model consisted of silicone tubings. Pulsatile flow was delivered at 1170 ml/min. Diluted packed erythrocytes were used (hematocrit of 33%). The Palmaz, MegaLink stents or Passager, Hemobahn stent grafts were p...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1664-z

    authors: Grimm J,Brunn H,Heller M,Mueller-Huelsbeck S

    更新日期:2003-06-01 00:00:00

  • Gastric cancer and image-derived quantitative parameters: Part 2-a critical review of DCE-MRI and 18F-FDG PET/CT findings.

    abstract::There is yet no consensus on the application of functional imaging and qualitative image interpretation in the management of gastric cancer. In this second part, we will discuss the role of image-derived quantitative parameters from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and 18F-fluorodeoxygluc...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-019-06370-x

    authors: Tang L,Wang XJ,Baba H,Giganti F

    更新日期:2020-01-01 00:00:00

  • Increased susceptibility of asymmetrically prominent cortical veins correlates with misery perfusion in patients with occlusion of the middle cerebral artery.

    abstract:OBJECTIVES:To evaluate tissue perfusion and venous susceptibility in ischaemic stroke patients as a means to predict clinical status and early prognosis. METHODS:A retrospective study of 51 ischaemic stroke patients were enrolled in this study. Susceptibility, perfusion and National Institute of Health stroke scale (N...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4593-y

    authors: Luo Y,Gong Z,Zhou Y,Chang B,Chai C,Liu T,Han Y,Wang M,Qian T,Haacke EM,Xia S

    更新日期:2017-06-01 00:00:00

  • Magnetisation transfer MR imaging of the kidney: evaluation at 3.0 T in association with renal function.

    abstract:OBJECTIVE:To evaluate the feasibility of using magnetisation transfer (MT) MRI of the kidney at 3.0 T to assess renal function. METHODS:Forty-four patients who underwent abdominal MRI on a 3.0-T system including gradient-echo (GRE) sequences with and without MT pulse were included. In each patient, MT ratio (MTR) of t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2841-y

    authors: Ito K,Hayashida M,Izumitani S,Fujimine T,Onishi T,Genba K

    更新日期:2013-08-01 00:00:00

  • Thoracic complications in uremic patients and in patients undergoing dialytic treatment: state of the art.

    abstract::No organ in the chest is spared the negative effects of uremia. The dialytic treatment itself is often associated with a large array of thoracic complications. We review the main thoracic manifestations of the terminal uremia from the radiological point of view, such as: uremic pleuritis and pericarditis, uremic pneum...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/BF02742931

    authors: Gavelli G,Zompatori M

    更新日期:1997-01-01 00:00:00

  • Magnetic resonance imaging of extrahepatic bile duct disruption.

    abstract::Blunt injury of the extrahepatic bile duct is rare and hence a large series of scientific study of its MRI is difficult to perform. We present the MRI and MR cholangiography of a case of blunt extrahepatic bile duct injury proven at surgery. The diagnosis could be established based on MRI findings of an abrupt taperin...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1296-8

    authors: Wong YC,Wang LJ,Chen RJ,Chen CJ

    更新日期:2002-10-01 00:00:00

  • Thyroid doses and risk to paediatric patients undergoing neck CT examinations.

    abstract:OBJECTIVE:To estimate thyroid doses and cancer risk for paediatric patients undergoing neck computed tomography (CT). METHODS:We used average CTDI(vol) (mGy) values from 75 paediatric neck CT examinations to estimate thyroid dose in a mathematical anthropomorphic phantom (ImPACT Patient CT Dosimetry Calculator). Patie...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3590-x

    authors: Spampinato MV,Tipnis S,Tavernier J,Huda W

    更新日期:2015-07-01 00:00:00

  • Differences in perfusion parameters between upper and lower lumbar vertebral segments with dynamic contrast-enhanced MRI (DCE MRI).

    abstract::To investigate the influence of age, sex and spinal level on perfusion parameters of normal lumbar bone marrow with dynamic contrast-enhanced MRI (DCE MRI). Sixty-seven subjects referred for evaluation of low back pain or sciatica underwent DCE MRI of the lumbar spine. After subtraction of dynamic images, a region of ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0943-8

    authors: Savvopoulou V,Maris TG,Vlahos L,Moulopoulos LA

    更新日期:2008-09-01 00:00:00

  • Effect of computer-aided detection as a second reader in multidetector-row CT colonography.

    abstract::Our purpose was to assess the effect of computer-aided detection (CAD) on lesion detection as a second reader in computed tomographic colonography, and to compare the influence of CAD on the performance of readers with different levels of expertise. Fifty-two CT colonography patient data-sets (37 patients: 55 endoscop...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0608-z

    authors: Mang T,Peloschek P,Plank C,Maier A,Graser A,Weber M,Herold C,Bogoni L,Schima W

    更新日期:2007-10-01 00:00:00

  • Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT.

    abstract::To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetect...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-008-0958-1

    authors: Berther R,Patak MA,Eckhardt B,Erturk SM,Zollikofer CL

    更新日期:2008-09-01 00:00:00

  • A pregnant lady with intermittent vaginal bleeding (2007: 3b). Placenta percreta.

    abstract::Placenta percreta is a potentially life-threatening complication of pregnancy, which is increasing in incidence. Ante-natal diagnosis with ultrasound and magnetic resonance imaging aids the obstetric team in planning further management. We present a case of placenta percreta with imaging and a brief review of the lite...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0498-5

    authors: Koo BC,Sala E,Hackett GA,Shaw AS

    更新日期:2007-06-01 00:00:00

  • The inhibitory effect of gadoxetate disodium on hepatic transporters: a study using indocyanine green.

    abstract:OBJECTIVES:To assess the inhibitory effect of gadoxetate disodium on the transporter system using indocyanine green (ICG). MATERIALS AND METHODS:Groups of six female B6 Albino mice were injected with the test agent (0.62 mmol/kg gadoxetate disodium) or phosphate-buffered saline (control) 10 min before injection of ICG...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5403-5

    authors: Akai H,Yasaka K,Kunimatsu A,Nojima M,Inoue Y,Abe O,Ohtomo K,Kiryu S

    更新日期:2018-10-01 00:00:00

  • Conspicuity of breast cancer according to histopathological type and breast density when imaged by full-field digital mammography compared with screen-film mammography.

    abstract:OBJECTIVES:To compare the conspicuity of different histopathological types of breast cancer according to breast density and mammographic imaging in patients with screen-detected breast cancers undergoing both full-field digital mammography (FFDM) and screen-film mammography (SFM) in the United Kingdom National Health S...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1906-4

    authors: Pinker K,Perry N,Vinnicombe S,Shiel S,Weber M

    更新日期:2011-01-01 00:00:00

  • The spectrum of brainstem malformations associated to mutations of the tubulin genes family: MRI and DTI analysis.

    abstract:OBJECTIVES:To describe the spectrum of brainstem malformations associated to mutations in the tubulin genes taking advantage of magnetic resonance imaging (MRI) and diffusion tensor imaging (DTI). METHODS:Fifteen patients (six males; median age, 1.25 years; range, 1 month to 31 years) with mutations in the tubulin gen...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5610-0

    authors: Arrigoni F,Romaniello R,Peruzzo D,Poretti A,Bassi MT,Pierpaoli C,Valente EM,Nuovo S,Boltshauser E,Huisman TAGM,Triulzi F,Borgatti R

    更新日期:2019-02-01 00:00:00

  • Acute cerebral stroke imaging and brain perfusion with the use of high-concentration contrast media.

    abstract::Acute cerebral stroke remains a major cause of death among adults and the emergence of new therapies has created a need for early and rapid imaging at a time when conventional CT is either normal or demonstrates subtle abnormalities that are easy to misinterpret. Perfusion CT uses the temporal changes in cerebral and ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-003-2104-4

    authors: Miles KA

    更新日期:2003-12-01 00:00:00