Quantitative CT texture and shape analysis: can it differentiate benign and malignant mediastinal lymph nodes in patients with primary lung cancer?

Abstract:

OBJECTIVE:To assess the accuracy of CT texture and shape analysis in the differentiation of benign and malignant mediastinal nodes in lung cancer. METHODS:Forty-three patients with biopsy-proven primary lung malignancy with pathological mediastinal nodal staging and unenhanced CT of the thorax were studied retrospectively. Grey-level co-occurrence and run-length matrix textural features, as well as morphological features, were extracted from 72 nodes. Differences between benign and malignant features were assessed using Mann-Whitney U tests. Receiver operating characteristic (ROC) curves for each were constructed and the area under the curve (AUC) calculated with histopathology diagnosis as outcome. Combinations of features were also entered as predictors in logistic regression models and optimal threshold criteria were used to estimate sensitivity and specificity. RESULTS:Using optimum-threshold criteria, the combined textural and shape features identified malignant mediastinal nodes with 81% sensitivity and 80% specificity (AUC = 0.87, P < 0.0001). Using this combination, 84% malignant and 71% benign nodes were correctly classified. CONCLUSIONS:Quantitative CT texture and shape analysis has the potential to accurately differentiate malignant and benign mediastinal nodes in lung cancer. KEY POINTS:• Mediastinal nodal staging is crucial in the management of lung cancer • Mediastinal nodal metastasis affects prognosis and suitability for surgical treatment • Computed tomography (CT) is limited for mediastinal nodal staging • Texture analysis measures tissue heterogeneity not perceptible to human vision • CT texture analysis may accurately differentiate malignant and benign mediastinal nodes.

journal_name

Eur Radiol

journal_title

European radiology

authors

Bayanati H,E Thornhill R,Souza CA,Sethi-Virmani V,Gupta A,Maziak D,Amjadi K,Dennie C

doi

10.1007/s00330-014-3420-6

subject

Has Abstract

pub_date

2015-02-01 00:00:00

pages

480-7

issue

2

eissn

0938-7994

issn

1432-1084

journal_volume

25

pub_type

杂志文章
  • Benign versus metastatic vertebral compression fractures: combined diffusion-weighted MRI and MR spectroscopy aids differentiation.

    abstract:OBJECTIVES:To determine the residual lipid fraction in fractured vertebrae by (1)H MR spectroscopy (MRS) and its confounding effect on differentiating benign from metastatic compression fractures of the spine using apparent diffusion coefficient (ADC) obtained by diffusion-weighted read-out-segmented echo-planar imagin...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2620-1

    authors: Rumpel H,Chong Y,Porter DA,Chan LL

    更新日期:2013-02-01 00:00:00

  • Low-dose triple-rule-out using 320-row-detector volume MDCT--less contrast medium and lower radiation exposure.

    abstract:OBJECTIVES:To investigate image quality of triple-rule-out (TRO) computed tomography (CT) using a 320-row-detector CT system with substantially reduced contrast medium volume at 100 kV. METHODS:Forty-six consecutive patients with noncritical, acute chest pain underwent 320-row-detector CT using a two-step TRO protocol...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2088-4

    authors: Durmus T,Rogalla P,Lembcke A,Mühler MR,Hamm B,Hein PA

    更新日期:2011-07-01 00:00:00

  • Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT.

    abstract:OBJECTIVES:To compare image quality and radiation dose of abdominal split-filter dual-energy CT (SF-DECT) combined with monoenergetic imaging to single-energy CT (SECT) with automatic tube voltage selection (ATVS). METHODS:Two-hundred single-source abdominal CT scans were performed as SECT with ATVS (n = 100) and SF-D...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5338-x

    authors: Euler A,Obmann MM,Szucs-Farkas Z,Mileto A,Zaehringer C,Falkowski AL,Winkel DJ,Marin D,Stieltjes B,Krauss B,Schindera ST

    更新日期:2018-08-01 00:00:00

  • Comparison of three cut-offs to diagnose clinically significant portal hypertension by liver stiffness in chronic viral liver diseases: a meta-analysis.

    abstract:BACKGROUND:Transient elastography-based liver stiffness value (TE-LSV) has been investigated for assessing clinically significant portal hypertension (CSPH). The aetiology of CSPH is an important factor determining TE-LSV. There is insufficient evidence for selecting cut-off values. AIMS:This study performed a meta-an...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析

    doi:10.1007/s00330-018-5478-z

    authors: Song J,Ma Z,Huang J,Liu S,Luo Y,Lu Q,Schwabl P,Zykus R,Kumar A,Kitson M

    更新日期:2018-12-01 00:00:00

  • Diffusion-weighted magnetic resonance imaging evaluation of intra-abdominal sites of implants to predict likelihood of suboptimal cytoreductive surgery in patients with ovarian carcinoma.

    abstract:OBJECTIVES:To analyse the diagnostic accuracy and to establish a predictive score based on diffusion-weighted magnetic resonance imaging (DWMRI) compared to exploratory laparotomy (EL) for predicting suboptimal cytoreductive surgery for different intra-abdominal sites of implants in patients with ovarian cancer. METHO...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2837-7

    authors: Espada M,Garcia-Flores JR,Jimenez M,Alvarez-Moreno E,De Haro M,Gonzalez-Cortijo L,Hernandez-Cortes G,Martinez-Vega V,Sainz De La Cuesta R

    更新日期:2013-09-01 00:00:00

  • Clinically suspected pulmonary embolism: is it safe to withhold anticoagulation after a negative spiral CT?

    abstract::The goal of this study was 3-month clinical outcome in nonanticoagulated patients with clinically suspected acute pulmonary embolism (PE) following a negative spiral CT. During a 6-month period 305 patients underwent spiral CT, of whom only 8 also had a lung scintigraphy. In patients with a final CT report read as not...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000539

    authors: Gottsäter A,Berg A,Centergård J,Frennby B,Nirhov N,Nyman U

    更新日期:2001-01-01 00:00:00

  • Diagnostic performance of dual-energy contrast-enhanced subtracted mammography in dense breasts compared to mammography alone: interobserver blind-reading analysis.

    abstract:PURPOSE:To analyse the accuracy of dual-energy contrast-enhanced spectral mammography in dense breasts in comparison with contrast-enhanced subtracted mammography (CESM) and conventional mammography (Mx). MATERIALS AND METHODS:CESM cases of dense breasts with histological proof were evaluated in the present study. Fou...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3271-1

    authors: Cheung YC,Lin YC,Wan YL,Yeow KM,Huang PC,Lo YF,Tsai HP,Ueng SH,Chang CJ

    更新日期:2014-10-01 00:00:00

  • 1H MR spectroscopy of mesial temporal lobe epilepsies treated with Gamma knife.

    abstract::Proton MR spectroscopy was used to observe long-term post-irradiation metabolic changes in epileptogenic tissue and in the contralateral parts of the brain which are not available with conventional imaging methods. We studied these changes in the temporal lobe in six patients, following radiosurgery on the amygdala an...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1723-5

    authors: Hájek M,Dezortová M,Liscák R,Vymazal J,Vladyka V

    更新日期:2003-05-01 00:00:00

  • Direct digital mammography image acquisition.

    abstract::Mammography is a branch of radiology which could benefit greatly from the assimilation of digital imaging technologies. Computerized enhancement techniques could be used to ensure optimum presentation of all clinical images. Beyond this it will facilitate powerful new clinical resources such as computer-assisted diagn...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050228

    authors: Cowen AR,Parkin GJ,Hawkridge P

    更新日期:1997-01-01 00:00:00

  • Delayed enhancement imaging of myocardial viability: low-dose high-pitch CT versus MRI.

    abstract:OBJECTIVES:To evaluate the accuracy of high-pitch delayed enhancement (DE) CT for the assessment of myocardial viability with MRI as the reference standard. METHODS:Twenty-four patients (mean age 66.9 ± 9.2 years) with coronary artery disease underwent DE imaging with 128-slice dual-source CT (prospective electrocardi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2149-8

    authors: Goetti R,Feuchtner G,Stolzmann P,Donati OF,Wieser M,Plass A,Frauenfelder T,Leschka S,Alkadhi H

    更新日期:2011-10-01 00:00:00

  • Ultrasound features of malignancy in the preoperative diagnosis of parathyroid cancer: a retrospective analysis of parathyroid tumours larger than 15 mm.

    abstract:OBJECTIVE:Nearly all reported parathyroid cancers are >15 mm at presentation. The objective was to identify ultrasound criteria of malignancy in parathyroid lesions of >15 mm in size. MATERIALS AND METHODS:This study was approved by a local ethics committee. A retrospective review of patients identified from a databas...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2141-3

    authors: Sidhu PS,Talat N,Patel P,Mulholland NJ,Schulte KM

    更新日期:2011-09-01 00:00:00

  • Intravoxel water diffusion heterogeneity MR imaging of nasopharyngeal carcinoma using stretched exponential diffusion model.

    abstract:PURPOSE:To determine the utility of stretched exponential diffusion model in characterisation of the water diffusion heterogeneity in different tumour stages of nasopharyngeal carcinoma (NPC). MATERIALS AND METHODS:Fifty patients with newly diagnosed NPC were prospectively recruited. Diffusion-weighted MR imaging was ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3535-9

    authors: Lai V,Lee VH,Lam KO,Sze HC,Chan Q,Khong PL

    更新日期:2015-06-01 00:00:00

  • Is imaging the future of axillary staging in breast cancer?

    abstract::Axillary management in patients with breast cancer has become much less invasive with the introduction of sentinel lymph node biopsy (SLNB). However, over 70 % of SLNBs are negative, questioning the generic use of this invasive procedure. Emerging evidence indicates that breast cancer patients with a low axillary burd...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-013-3009-5

    authors: Ahmed M,Usiskin SI,Hall-Craggs MA,Douek M

    更新日期:2014-02-01 00:00:00

  • IVIM with fractional perfusion as a novel biomarker for detecting and grading intestinal fibrosis in Crohn's disease.

    abstract:OBJECTIVES:Intravoxel incoherent motion (IVIM) diffusion-weighted magnetic resonance imaging (MRI) provides information on both perfusion and diffusion and has been used to evaluate Crohn's disease (CD) activity and fibrosis in children; however, there are no reports on its use in adults. We aimed to determine its valu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5848-6

    authors: Zhang MC,Li XH,Huang SY,Mao R,Fang ZN,Cao QH,Zhang ZW,Yan X,Chen MH,Li ZP,Sun CH,Feng ST

    更新日期:2019-06-01 00:00:00

  • Measuring tongue volumes and visualizing the chewing and swallowing process using real-time TrueFISP imaging--initial clinical experience in healthy volunteers and patients with acromegaly.

    abstract::This study assessed both two-dimensional (2D) TrueFISP imaging for quantifying tongue volume and real-time TrueFISP imaging for evaluating chewing and swallowing in healthy volunteers and patients with acromegaly. In 50 healthy volunteers, tongue volumes were measured using a 2D TrueFISP sequence. Chewing and swallowi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2596-6

    authors: Ajaj W,Goyen M,Herrmann B,Massing S,Goehde S,Lauenstein T,Ruehm SG

    更新日期:2005-05-01 00:00:00

  • Systolic prospectively ECG-triggered dual-source CT angiography for evaluation of the coronary arteries in heart transplant recipients.

    abstract:OBJECTIVES:To assess feasibility, image quality, and radiation dose of prospectively ECG-triggered coronary CT angiography (CTA) in orthotopic heart transplant (OHT) recipients. METHODS:47 consecutive OHT recipients (40 men, mean age 62.1 ± 10.9 years, mean heart rate 86.3 ± 14.4 bpm) underwent dual-source CTA to rule...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2126-2

    authors: Bastarrika G,Broncano J,Arraiza M,Azcárate PM,Simon-Yarza I,Levy Praschker BG,Pueyo JC,Zubieta JL,Rabago G

    更新日期:2011-09-01 00:00:00

  • MRI of the rectum: non-neoplastic disease.

    abstract::The rectum has become the most successful area of the gastrointestinal tract to be studied with MRI. Its anatomical location, fixed in the pelvic fat, and its lack of peristalsis, make it an ideal organ to be scanned with MRI. In addition, MRI allows a direct sagittal and coronal display, of key importance to colorect...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050328

    authors: Paley MR,Ros PR

    更新日期:1998-01-01 00:00:00

  • CT-guided radiofrequency ablation of spinal osteoid osteomas with concomitant perineural and epidural irrigation for neuroprotection.

    abstract::Here we report our experience of a neuroprotective adaptation of the technique of CT-guided radiofrequency (RF) ablation of spinal osteoid osteomas. Over 9 years seven patients underwent eight CT-guided RF treatments for osteoid osteoma. CT-guided RF ablation was performed with general anaesthesia. The lesion was heat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1404-8

    authors: Klass D,Marshall T,Toms A

    更新日期:2009-09-01 00:00:00

  • Correction to: Cone-beam breast CT features associated with HER2/neu overexpression in patients with primary breast cancer.

    abstract::The original version of this article, published on 03 January 2020, unfortunately contained two mistakes. ...

    journal_title:European radiology

    pub_type: 杂志文章,已发布勘误

    doi:10.1007/s00330-020-06673-4

    authors: Zhu Y,Zhang Y,Ma Y,Li H,Liu A,Han P,Yin L,Lv N,Li Z,Lu H,Liu P,Ye Z

    更新日期:2020-06-01 00:00:00

  • Cervical myositis ossificans traumatica: a rare location.

    abstract::An unusual case of myositis ossificans traumatica lesion located in the paraspinal region is reported. Despite the contiguity of the lesion with the cervical vertebrae and ominous appearance of the biopsy material, the history of antecedent trauma and computed tomography findings allowed preoperative accurate diagnosi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050728

    authors: Baysal T,Baysal O,Sarac K,Elmali N,Kutlu R,Ersoy Y

    更新日期:1999-01-01 00:00:00

  • Acute cerebral stroke imaging and brain perfusion with the use of high-concentration contrast media.

    abstract::Acute cerebral stroke remains a major cause of death among adults and the emergence of new therapies has created a need for early and rapid imaging at a time when conventional CT is either normal or demonstrates subtle abnormalities that are easy to misinterpret. Perfusion CT uses the temporal changes in cerebral and ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-003-2104-4

    authors: Miles KA

    更新日期:2003-12-01 00:00:00

  • Significant differences when using MDRD for GFR estimation compared to radionuclide measured clearance.

    abstract:OBJECTIVES:To evaluate Estimated Glomerular Filtration Rate (eGFR), using the Modification of Diet in Renal Disease equation, and compare with radionuclide GFR (rGFR) in a Radiology setting to assess renal function prior to contrast administration. METHODS:Five hundred and sixteen retrospective rGFR studies from a mix...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2157-8

    authors: Craig AJ,Britten A,Heenan SD,Irwin AG

    更新日期:2011-10-01 00:00:00

  • Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience.

    abstract:OBJECTIVE:To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. METHODS:One hundred and sixty patients were randomly divided into two sc...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4349-8

    authors: Lv P,Liu J,Chai Y,Yan X,Gao J,Dong J

    更新日期:2017-01-01 00:00:00

  • Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time.

    abstract::The influence of the frequency of computed tomography (CT) image acquisition on the diagnostic quality of dynamic perfusion CT (PCT) studies of the brain was investigated. Eight patients with clinically suspected acute ischemia of one hemisphere underwent PCT, performed on average 3.4 h after the onset of symptoms. Si...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1083-x

    authors: Wiesmann M,Berg S,Bohner G,Klingebiel R,Schöpf V,Stoeckelhuber BM,Yousry I,Linn J,Missler U

    更新日期:2008-12-01 00:00:00

  • Effective dose in Albanian direct chest fluoroscopy.

    abstract::In the absence of reliable supplies of X-ray film, direct fluoroscopy is still extensively used in Albania, with chest radiology a particularly common application. This paper aims to quantify both patient skin dose and the risk-related quantity effective dose for direct fluoroscopy units based in seven different Alban...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000462

    authors: Marshall NW,Shehu G,Marsh D,Faulkner K,Malone J,Dewhurst K

    更新日期:2001-01-01 00:00:00

  • Intra-abdominal desmoplastic small round-cell tumor: a rare cause of peritoneal malignancy in young people.

    abstract::We report the CT and pathological findings of an intra-abdominal desmoplastic small round-cell tumor in a young man. Computed tomography showed an extensive peritoneal and mesenteric disease with gross bulky masses, direct liver invasion, and lymph node involvement. This entity should be considered in the differential...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300051011

    authors: Sabaté JM,Torrubia S,Roson N,Matias-Guiu X,Gómez A

    更新日期:2000-01-01 00:00:00

  • Cystic lymphangioma of the upper extremity: US and MRI correlation (2004:11b).

    abstract::The authors described a very rare case of the cystic lymphangioma (CL) of the left upper extremity in a 12-year-old patient. The diagnosis was made by US and MRI and confirmed by histological examination of the resected specimen. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2347-8

    authors: Rossi G,Iannicelli E,Almberger M,Innocenzi D,David V

    更新日期:2005-02-01 00:00:00

  • Testicular microlithiasis: is there a need for surveillance in the absence of other risk factors?

    abstract:OBJECTIVE:Ultrasound surveillance of patients with testicular microlithiasis (TM) has been advocated following the reported association with testicular cancer. The aim of this study was to assess the evidence base supporting such surveillance. METHODS:Formal literature review identified cohort studies comprising at le...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析

    doi:10.1007/s00330-012-2520-4

    authors: Richenberg J,Brejt N

    更新日期:2012-11-01 00:00:00

  • Reproducibility of linear tumor measurements using PACS: comparison of caliper method with edge-tracing method.

    abstract::The aim of this study was to evaluate inter- and intra-observer reproducibility when making electronic caliper linear tumor measurements on picture archiving and communications systems (PACS) and compare them with linear measurements obtained from circumferential tracing of tumor perimeter. Three radiologists measured...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-2027-0

    authors: Monsky WL,Raptopoulos V,Keogan MT,Doty D,Kamel I,Yam CS,Ransil BJ

    更新日期:2004-03-01 00:00:00

  • Transarterial embolization as a therapeutic option for focal nodular hyperplasia in four patients.

    abstract::The purpose of this study was to evaluate the potential of transarterial embolization (TAE) for the treatment of focal nodular hyperplasia (FNH). Four women with the diagnosis of FNH underwent superselective transarterial embolization with contour particles between 2001 and 2004. The indications were progressive incre...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2885-8

    authors: Vogl TJ,Own A,Hammerstingl R,Reichel P,Balzer JO

    更新日期:2006-03-01 00:00:00