Correction to: Cone-beam breast CT features associated with HER2/neu overexpression in patients with primary breast cancer.

Abstract:

:The original version of this article, published on 03 January 2020, unfortunately contained two mistakes.

journal_name

Eur Radiol

journal_title

European radiology

authors

Zhu Y,Zhang Y,Ma Y,Li H,Liu A,Han P,Yin L,Lv N,Li Z,Lu H,Liu P,Ye Z

doi

10.1007/s00330-020-06673-4

subject

Has Abstract

pub_date

2020-06-01 00:00:00

pages

3594-3595

issue

6

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-020-06673-4

journal_volume

30

pub_type

杂志文章,已发布勘误
  • Dynamic contrast-enhanced magnetic resonance imaging with Gd-EOB-DTPA for the evaluation of liver fibrosis in chronic hepatitis patients.

    abstract:OBJECTIVES:To develop a non-invasive MRI method for evaluation of liver fibrosis, with histological analysis as the reference standard. METHODS:The study protocol was approved by the Institutional Review Board for Human Studies of our hospital, and written informed consent was obtained from all subjects. Seventy-nine ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2249-5

    authors: Chen BB,Hsu CY,Yu CW,Wei SY,Kao JH,Lee HS,Shih TT

    更新日期:2012-01-01 00:00:00

  • MR urography of obstructive uropathy: diagnostic value of the method in selected clinical groups.

    abstract::The aim of the study was to evaluate the role of MR urography (MRU) in the diagnosis of obstructive uropathy in selected groups of patients. The groups involved following pathologies: calculi; strictures of ureteropelvic junction (UPJ); benign and malignancy-induced ureterostenosis. Sixty patients with clinical diagno...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1550-8

    authors: Zielonko J,Studniarek M,Markuszewski M

    更新日期:2003-04-01 00:00:00

  • Reproducibility over a 1-month period of 1H-MR spectroscopic imaging NAA/Cr ratios in clinically stable multiple sclerosis patients.

    abstract::N-acetylaspartate/creatine (NAA/Cr) ratios, assessed with proton magnetic resonance spectroscopy, are increasingly used as a surrogate marker for axonal dysfunction and degeneration in multiple sclerosis (MS). The purpose of this study was to test short-time reproducibility of NAA/Cr ratios in patients with clinically...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0925-x

    authors: Mostert JP,Blaauw Y,Koch MW,Kuiper AJ,Hoogduin JM,De Keyser J

    更新日期:2008-08-01 00:00:00

  • Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study.

    abstract::The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5....

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0668-0

    authors: Florie J,van Gelder RE,Schutter MP,van Randen A,Venema HW,de Jager S,van der Hulst VP,Prent A,Bipat S,Bossuyt PM,Baak LC,Stoker J

    更新日期:2007-12-01 00:00:00

  • Increased epicardial fat is independently associated with the presence and chronicity of atrial fibrillation and radiofrequency ablation outcome.

    abstract:OBJECTIVE:To determine whether intrathoracic fat volumes are associated with presence and chronicity of atrial fibrillation (AF) and radiofrequency ablation (RFA) treatment outcome. METHODS:IRB approval was obtained and patient consent was waived for this HIPAA-compliant retrospective study. 169 patients with AF (75 n...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3643-1

    authors: Stojanovska J,Kazerooni EA,Sinno M,Gross BH,Watcharotone K,Patel S,Jacobson JA,Oral H

    更新日期:2015-08-01 00:00:00

  • MRI-based radiomics signature for localized prostate cancer: a new clinical tool for cancer aggressiveness prediction? Sub-study of prospective phase II trial on ultra-hypofractionated radiotherapy (AIRC IG-13218).

    abstract:OBJECTIVES:Radiomic involves testing the associations of a large number of quantitative imaging features with clinical characteristics. Our aim was to extract a radiomic signature from axial T2-weighted (T2-W) magnetic resonance imaging (MRI) of the whole prostate able to predict oncological and radiological scores in ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07105-z

    authors: Gugliandolo SG,Pepa M,Isaksson LJ,Marvaso G,Raimondi S,Botta F,Gandini S,Ciardo D,Volpe S,Riva G,Rojas DP,Zerini D,Pricolo P,Alessi S,Petralia G,Summers PE,Mistretta FA,Luzzago S,Cattani F,De Cobelli O,Cassano E,

    更新日期:2021-02-01 00:00:00

  • Interstitial photodynamic laser therapy in interventional oncology.

    abstract::Photodynamic therapy (PDT) is a well-investigated locoregional cancer treatment in which a systemically administered photosensitizer is activated locally by illuminating the diseased tissue with light of a suitable wavelength. PDT offers various treatment strategies in oncology, especially palliative ones. This articl...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2290-8

    authors: Vogl TJ,Eichler K,Mack MG,Zangos S,Herzog C,Thalhammer A,Engelmann K

    更新日期:2004-06-01 00:00:00

  • Perfusion CT in patients with advanced bronchial carcinomas: a novel chance for characterization and treatment monitoring?

    abstract::Advanced bronchial carcinomas by means of perfusion and peak enhancement using dynamic contrast-enhanced multislice CT are characterized. Twenty-four patients with advanced bronchial carcinoma were examined. During breathhold, after injection of a contrast-medium (CM), 25 scans were performed (1 scan/s) at a fixed tab...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2288-2

    authors: Kiessling F,Boese J,Corvinus C,Ederle JR,Zuna I,Schoenberg SO,Brix G,Schmähl A,Tuengerthal S,Herth F,Kauczor HU,Essig M

    更新日期:2004-07-01 00:00:00

  • Giant cavernoma of the brain stem: value of delayed MR imaging after contrast injection.

    abstract::Cavernous angiomas are vascular malformations composed of slowly perfused, sinusoidal vessels which can be located in any part of the central nervous system. Whereas diagnosis is mostly straightforward in typical cases, some lesions may present in unusual locations or with unusual imaging characteristics. Because of t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:

    authors: Thiex R,Krüger R,Friese S,Grönewäller E,Küker W

    更新日期:2003-12-01 00:00:00

  • Artificial intelligence for detecting small FDG-positive lung nodules in digital PET/CT: impact of image reconstructions on diagnostic performance.

    abstract:OBJECTIVES:To evaluate the diagnostic performance of a deep learning algorithm for automated detection of small 18F-FDG-avid pulmonary nodules in PET scans, and to assess whether novel block sequential regularized expectation maximization (BSREM) reconstruction affects detection accuracy as compared to ordered subset e...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06498-w

    authors: Schwyzer M,Martini K,Benz DC,Burger IA,Ferraro DA,Kudura K,Treyer V,von Schulthess GK,Kaufmann PA,Huellner MW,Messerli M

    更新日期:2020-04-01 00:00:00

  • Involvement patterns in myotilinopathy and desminopathy detected by a novel neuromuscular whole-body MRI protocol.

    abstract::Whole-body MRI (WB-MRI) has been successfully applied for oncologic and cardiovascular diagnostics, whereas imaging in myopathies usually employs dedicated protocols restricted to areas of specific interest. In this study, we propose a comprehensive neuromuscular WB-MRI protocol. Eighteen patients with degenerative an...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1071-1

    authors: Schramm N,Born C,Weckbach S,Reilich P,Walter MC,Reiser MF

    更新日期:2008-12-01 00:00:00

  • Influence of statin treatment on coronary atherosclerosis visualised using multidetector computed tomography.

    abstract:OBJECTIVE:Coronary angiography using multidetector computed tomography (MDCT) allows non-invasive assessment of non-calcified, calcified and mixed plaques. Progression of coronary plaques may be influenced by statins. METHODS:Sixty-three consecutive patients underwent MDCT as a follow-up to their original CT angiograp...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00330-010-1880-x

    authors: Hoffmann H,Frieler K,Schlattmann P,Hamm B,Dewey M

    更新日期:2010-12-01 00:00:00

  • High-resolution real-time compound ultrasound imaging of transient protein-losing gastropathy of childhood.

    abstract::We report the case of a 1.5-year-old girl with transient protein-losing gastropathy with hypertrophic gastric folds (PLGH). The diagnosis of PLGH was made by abdominal ultrasound (US) and not by an upper gastrointestinal (UGI) study as reported in many previous publications. Real-time compound ultrasound imaging showe...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-2071-9

    authors: Smet MH,Mussen E,Ectors N,Breysem L

    更新日期:2003-12-01 00:00:00

  • Significant differences when using MDRD for GFR estimation compared to radionuclide measured clearance.

    abstract:OBJECTIVES:To evaluate Estimated Glomerular Filtration Rate (eGFR), using the Modification of Diet in Renal Disease equation, and compare with radionuclide GFR (rGFR) in a Radiology setting to assess renal function prior to contrast administration. METHODS:Five hundred and sixteen retrospective rGFR studies from a mix...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2157-8

    authors: Craig AJ,Britten A,Heenan SD,Irwin AG

    更新日期:2011-10-01 00:00:00

  • Development and evaluation of a new gray-scale test pattern to adjust gradients of thoracic CT imaging.

    abstract::The purpose of the present study was to evaluate the usefulness of a new gray-scale test pattern (NGTP) that was developed to easily adjust the gradients of thoracic CT imaging and enable visual consistency. The Society of Motion Picture and Television Engineers (SMPTE) pattern and the NGTP were used for comparison. T...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2315-3

    authors: Yamaguchi M,Fujita H,Uemura M,Asai Y,Wakae H,Ishifuro M

    更新日期:2004-12-01 00:00:00

  • Correlation between the availability of dopamine transporter and olfactory function in healthy subjects.

    abstract:OBJECTIVES:Olfactory dysfunction in Parkinson's disease is usually prodromal to other symptoms. In this study, we aimed to explore the association of olfactory function with the availabilities of striatal dopamine transporter (DAT) in healthy subjects. METHODS:Data used in the preparation of this article were obtained...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5147-7

    authors: Pak K,Kim K,Lee MJ,Lee JM,Kim BS,Kim SJ,Kim IJ

    更新日期:2018-04-01 00:00:00

  • Radiation dose management systems-requirements and recommendations for users from the ESR EuroSafe Imaging initiative.

    abstract::The European Directive 2013/59/Euratom requires member states of the European Union to ensure justification and optimisation of radiological procedures and store information on patient exposure for analysis and quality assurance. The EuroSafe Imaging campaign of the European Society of Radiology created a working grou...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07290-x

    authors: Loose RW,Vano E,Mildenberger P,Tsapaki V,Caramella D,Sjöberg J,Paulo G,Torresin A,Schindera S,Frija G,Damilakis J,European Society of Radiology (ESR).

    更新日期:2020-09-21 00:00:00

  • Congenital midline cleft of the posterior arch of atlas: a rare cause of symptomatic cervical canal stenosis.

    abstract::Developmental symptomatic C1 canal stenosis is very rare. We describe the computed tomography (CT) and magnetic resonance imaging (MRI) appearances in a 8-year-old child who presented with progressive upper and lower limb neurological symptoms and in whom imaging revealed the medial posterior hemiarches of a bifid C1 ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000755

    authors: Connor SE,Chandler C,Robinson S,Jarosz JM

    更新日期:2001-01-01 00:00:00

  • Intra-articular ganglion cysts of the cruciate ligaments.

    abstract::Intra-articular ganglion cysts of the cruciate ligaments are associated with non-specific clinical signs and symptoms. Familiarity with the MR appearances in particular is important to make an accurate diagnosis, exclude associated abnormalities, and avoid misdiagnosis. ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003309900290

    authors: Tyrrell PN,Cassar-Pullicino VN,McCall IW

    更新日期:2000-01-01 00:00:00

  • Plunging ranulas: high-resolution ultrasound for diagnosis and surgical management.

    abstract:OBJECTIVES:We see a high incidence of plunging ranulas, particularly in Maori and Polynesian populations. We have investigated the usefulness of ultrasound in the diagnosis and management of plunging ranulas and present our findings. METHODS:Thirty-three new cases were examined over 4 years (June 2004 to October 2008)...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1666-1

    authors: Jain P,Jain R,Morton RP,Ahmad Z

    更新日期:2010-06-01 00:00:00

  • Quantitative MRI using STrategically Acquired Gradient Echo (STAGE): optimization for 1.5 T scanners and T1 relaxation map validation.

    abstract:OBJECTIVES:The strategically acquired gradient echo (STAGE) protocol, developed for 3T scanners, allows one to derive quantitative maps such as T1, T2*, proton density, and quantitative susceptibility mapping in about 5 min. Our aim was to adapt the STAGE sequences for 1.5T scanners which are still commonly used in cli...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07515-z

    authors: Pirastru A,Chen Y,Pelizzari L,Baglio F,Clerici M,Haacke EM,Laganà MM

    更新日期:2021-01-06 00:00:00

  • Diagnosis of pulmonary embolism with spiral CT as a second procedure following scintigraphy.

    abstract::Our objective was to evaluate, in a routine clinical setting, the role of spiral CT as a second procedure in patients with clinically suspected pulmonary embolism (PE) and abnormal perfusion scan. We prospectively studied the role of spiral CT in 279 patients suspected of PE. All patients started their diagnostic algo...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-002-1709-3

    authors: van Strijen MJ,de Monyé W,Kieft GJ,Pattynama PM,Huisman MV,Smith SJ,Bloem JL

    更新日期:2003-07-01 00:00:00

  • Feasibility of in vivo diffusion tensor imaging of articular cartilage with coverage of all cartilage regions.

    abstract:OBJECTIVES:To investigate the value of diffusion tensor imaging (DTI) of articular cartilage to differentiate healthy from osteoarthritis (OA) subjects in all cartilage regions. METHODS:DTI was acquired sagittally at 7 T in ten healthy and five OA (Kellgren-Lawrence grade 2) subjects with a line scan diffusion tensor ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3155-4

    authors: Raya JG,Dettmann E,Notohamiprodjo M,Krasnokutsky S,Abramson S,Glaser C

    更新日期:2014-07-01 00:00:00

  • The impact of preoperative axillary ultrasonography in T1 breast tumours.

    abstract:OBJECTIVES:To (a) determine the diagnostic validity of axillary ultrasound (AUS) in pT1 tumours and whether fine-needle aspiration (FNA) improves its diagnostic performance, and (b) determine the negative predictive value (NPV) of AUS in a simulation environment (cutoff: two lymph nodes with macrometastases) in patient...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-015-3901-2

    authors: del Riego J,Diaz-Ruiz MJ,Teixidó M,Ribé J,Vilagran M,Canales L,Sentís M,Grup de Mama Vallès-Osona-Bages (GMVOB; Cooperative Breast Workgroup Vallés-Osona-Bagés).

    更新日期:2016-04-01 00:00:00

  • Three-dimensional cholangio-spiral CT demonstration of a post-traumatic bile leak in a child.

    abstract::Bilioma is a rare complication of traumatic liver injury, and the precise site of bile leak is often difficult to demonstrate with a non-invasive technique. We report a case of post-traumatic bile leak in a 15-year-old girl in whom spiral CT after intravenous cholangiography allowed excellent preoperative demonstratio...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050637

    authors: Wicky S,Gudinchet F,Barghouth G,Schnyder P

    更新日期:1999-01-01 00:00:00

  • Two-dimensional and three-dimensional oxygen mapping by 3He-MRI validation in a lung phantom.

    abstract::The aim of this study was to validate oxygen-sensitive 3He-MRI in noninvasive determination of the regional, two- and three-dimensional distribution of oxygen partial pressure. In a gas-filled elastic silicon ventilation bag used as a lung phantom, oxygen sensitive two- and three-dimensional 3He-MRI measurements were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2778-x

    authors: Gast KK,Schreiber WG,Herweling A,Lehmann F,Erdös G,Schmiedeskamp J,Kauczor HU,Eberle B

    更新日期:2005-09-01 00:00:00

  • Increased diagnostic accuracy of giant cell arteritis using three-dimensional fat-saturated contrast-enhanced vessel-wall magnetic resonance imaging at 3 T.

    abstract:OBJECTIVES:To compare the diagnostic accuracy of 3D versus 2D contrast-enhanced vessel-wall (CE-VW) MRI of extracranial and intracranial arteries in the diagnosis of GCA. METHODS:This prospective two-center study was approved by a national research ethics board and enrolled participants from December 2014 to October 2...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06536-7

    authors: Poillon G,Collin A,Benhamou Y,Clavel G,Savatovsky J,Pinson C,Zuber K,Charbonneau F,Vignal C,Picard H,Leturcq T,Miranda S,Sené T,Gerardin E,Lecler A

    更新日期:2020-04-01 00:00:00

  • Clinical role of early dynamic FDG-PET/CT for the evaluation of renal cell carcinoma.

    abstract:OBJECTIVES:We studied the usefulness of early dynamic (ED) and whole-body (WB) FDG-PET/CT for the evaluation of renal cell carcinoma (RCC). METHODS:One hundred patients with 107 tumours underwent kidney ED and WB FDG-PET/CT. We visually and semiquantitatively evaluated the FDG accumulation in RCCs in the ED and WB pha...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4026-3

    authors: Nakajima R,Abe K,Kondo T,Tanabe K,Sakai S

    更新日期:2016-06-01 00:00:00

  • Post-hepatectomy liver failure after major hepatic surgery: not only size matters.

    abstract:OBJECTIVES:To compare the value of functional future liver remnant (functFLR) to established clinical and imaging variables in prediction of post-hepatectomy liver failure (PHLF) after major liver resection. METHODS:This retrospective, cross-sectional study included 62 patients, who underwent gadoxetic acid enhanced M...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5487-y

    authors: Asenbaum U,Kaczirek K,Ba-Ssalamah A,Ringl H,Schwarz C,Waneck F,Fitschek F,Loewe C,Nolz R

    更新日期:2018-11-01 00:00:00

  • Influence of patient axial malpositioning on the trueness and precision of pelvic parameters obtained from 3D reconstructions based on biplanar radiographs.

    abstract:OBJECTIVES:Radiographs are often performed to assess pelvic and hip parameters, but results depend upon correct pelvis positioning. Three-dimensional (3D) reconstruction from biplanar-radiographs should provide parameters that are less sensitive to pelvic orientation, but this remained to be evaluated. METHODS:Compute...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4452-x

    authors: Ghostine B,Sauret C,Assi A,Bakouny Z,Khalil N,Skalli W,Ghanem I

    更新日期:2017-03-01 00:00:00