Abstract:
OBJECTIVE:To evaluate the feasibility of using magnetisation transfer (MT) MRI of the kidney at 3.0 T to assess renal function. METHODS:Forty-four patients who underwent abdominal MRI on a 3.0-T system including gradient-echo (GRE) sequences with and without MT pulse were included. In each patient, MT ratio (MTR) of the renal cortex and medulla was measured by using regions of interest (ROIs) placed on the MTR map image. RESULTS:Regression analysis showed good correlation between estimated glomerular filtration rate (eGFR) and MTR of the renal cortex (r = -0.645, P < 0.0001). Among 44 patients, 22 were categorised as the normal renal function group and 22 were classified as the decreased eGFR group. The mean MTR of the renal cortex in patients with decreased eGFR (mean MTR, 30.7 ± 3.2 %) was significantly higher (P < 0.0001) than that in patients with normal renal function (mean MTR, 25.3 ± 2.2 %), although the mean MTRs of the renal medulla in the two groups were not significantly different. CONCLUSION:There was good correlation between eGFR and MTR of the renal cortex derived from MT MRI at 3.0 T. This technique may have the potential to evaluate the degree of renal function non-invasively in patients with renal impairment. KEY POINTS:• Magnetisation transfer techniques can provide new information about renal disease. • MTR values of the renal cortex correlate well with estimated glomerular filtration. • Higher MTR of the renal cortex exists in patients with renal dysfunction. • MT MRI at 3.0 T may be useful for evaluating renal function.
journal_name
Eur Radioljournal_title
European radiologyauthors
Ito K,Hayashida M,Izumitani S,Fujimine T,Onishi T,Genba Kdoi
10.1007/s00330-013-2841-ysubject
Has Abstractpub_date
2013-08-01 00:00:00pages
2315-9issue
8eissn
0938-7994issn
1432-1084journal_volume
23pub_type
杂志文章abstract::Adenocarcinoma is the most common malignant pancreatic tumor, affecting the head of the pancreas in 60-70% of cases. By the time of diagnosis, at least 80% of tumors are unresectable. Helical computed tomography (CT) is very effective in detecting and staging adenocarcinoma, with a sensitivity of up to 90% for detecti...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-006-0435-7
更新日期:2007-03-01 00:00:00
abstract:OBJECTIVES:To investigate the survival benefit of transarterial chemoembolization (TACE) plus Iodine125 seed implantation (TACE-Iodine125) in hepatitis B-related HCC patients with portal vein tumour thrombus (PVTT) and the underlying prognostic factors. METHODS:A retrospective matched cohort study was performed on con...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-4198-x
更新日期:2016-10-01 00:00:00
abstract::Several skeletal variations of the upper extremity may cause painful conditions or precipitate early degenerative changes, either spontaneously or in response to overuse and trauma. Magnetic resonance imaging has proved particularly useful for accurate interpretation of many of these clinically significant skeletal va...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1660-3
更新日期:2003-07-01 00:00:00
abstract::Intussusception represents the most common abdominal emergency in infancy. The classical clinical triad, consisting of abdominal colics, red jelly stools and a palpable mass, is only present in approximately 50% of cases, 20% of patients are symptom free at clinical presentation. Primary imaging modality of choice is ...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-003-2033-2
更新日期:2004-03-01 00:00:00
abstract::Ankle impingement syndromes are categorised according to their anatomical site around the tibiotalar joint. Anterolateral, anterior and posterior ankle impingement has been extensively described in the orthopaedic and radiology literature with more recent studies describing posteromedial and anteromedial impingement. ...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-007-0675-1
更新日期:2007-12-01 00:00:00
abstract::The feasibility of large-core-needle magnetic resonance imaging (MRI)-guided breast biopsy at 3 T was assessed. Thirty-one suspicious breast lesions shown only by MRI were detected in 30 patients. Biopsy procedures were performed in a closed-bore 3-T clinical MR system on a dedicated phased-array breast coil with a co...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1310-0
更新日期:2009-07-01 00:00:00
abstract:OBJECTIVES:Intravoxel incoherent motion (IVIM) diffusion-weighted magnetic resonance imaging (MRI) provides information on both perfusion and diffusion and has been used to evaluate Crohn's disease (CD) activity and fibrosis in children; however, there are no reports on its use in adults. We aimed to determine its valu...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5848-6
更新日期:2019-06-01 00:00:00
abstract::This paper presents work on interactive 2D projection magnetic resonance angiography, based on fresh blood imaging (FBI), which integrates navigation and triggering optimisation into a continuous fluoroscopic procedure. The technique was developed on a clinical 1.5-T MRI system and performed in five healthy volunteers...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-008-1218-0
更新日期:2009-04-01 00:00:00
abstract::The purpose was to provide a diffusion-weighted whole-body magnetic resonance (MR) imaging sequence with background body signal suppression (DWIBS) at 3.0 Tesla. A diffusion-weighted spin-echo echo-planar imaging sequence was combined with the following methods of fat suppression: short TI inversion recovery (STIR), s...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-007-0717-8
更新日期:2007-12-01 00:00:00
abstract:OBJECTIVES:To compare fused gadoxetate-enhanced Ga-68-DOTANOC PET/MRI and Ga-68-DOTANOC PET/DWI (diffusion-weighted imaging) for the assessment of abdominal neuroendocrine tumours (NETs). METHODS:Eighteen patients with suspected or histologically proven NETs of the abdomen were enrolled in this retrospective study. Al...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-013-2785-2
更新日期:2013-07-01 00:00:00
abstract:OBJECTIVES:To apply an easy-to-assemble phantom substitute for human prostates in T2-weighted magnetic resonance imaging (T2WI), diffusion-weighted imaging (DWI) and 3D magnetic resonance spectroscopy (MRS). METHODS:Kiwi fruit were fixed with gel hot and cold compress packs on two plastic nursery pots, separated by a ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4706-7
更新日期:2017-08-01 00:00:00
abstract::We report a case of renal cell carcinoma with solitary metachronous contralateral adrenal metastasis occurring 23 years after radical nephrectomy. The patient was treated with adrenalectomy. He is alive with no evidence of disease 1 year postoperatively. Solitary metachronous contralateral adrenal metastases from rena...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050204
更新日期:1997-01-01 00:00:00
abstract:OBJECTIVES:To evaluate the association between tumour FDG uptake on preoperative PET/CT and axillary lymph node metastasis (ALNM) according to breast cancer subtype. METHODS:The records of 671 patients with invasive breast cancer who underwent (18) F-FDG PET/CT and surgery were reviewed. Using immunohistochemistry, tu...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3452-y
更新日期:2015-04-01 00:00:00
abstract::This technical note describes a novel CT scan protocol that includes a non-enhanced CT, dynamic CTA, and perfusion of the whole brain and CTA of the carotid arteries using a 320-row area detector CT scanner, with a unique contrast injection and acceptable radiation exposure dose in patients presenting with acute ische...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06041-x
更新日期:2019-09-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to investigate the association of relaxation-compensated chemical exchange saturation transfer (CEST) MRI with overall survival (OS) and progression-free survival (PFS) in newly diagnosed high-grade glioma (HGG) patients. METHODS:Twenty-six patients with newly diagnosed high-gr...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06066-2
更新日期:2019-09-01 00:00:00
abstract::Endovascular treatment options for visceral artery pseudoaneurysms depend on lesion location and size. Exclusion methods fall into two categories, embolization and stent placement, and these procedures aim to exclude the pseudoaneurysm from the circulation and if possible to maintain distal blood flow. Embolization of...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-008-1053-3
更新日期:2008-11-01 00:00:00
abstract:PURPOSE:To evaluate magnetic resonance imaging (MRI) for diaphragmatic endometriosis diagnosis. MATERIALS AND METHODS:Over a 2-year period, all diaphragmatic MRI performed in the context of diaphragmatic endometriosis were reviewed. Axial and coronal fat-suppressed T1- and T2-weighted sequences were analyzed by two in...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4226-5
更新日期:2016-11-01 00:00:00
abstract:OBJECTIVES:Cardiovascular magnetic resonance (CMR) provides information on myocardial ischemia through stress perfusion studies. In clinical practice, the grading of induced perfusion defects is performed by visual estimation of their extension. The aim of our study is to devise a score of the degree of ischemia and to...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5774-7
更新日期:2019-05-01 00:00:00
abstract:OBJECTIVE:To evaluate the delayed effects of irreversible electroporation (IRE) ablation on nerves. METHODS:The study was approved by the institutional animal care and use committee. CT-guided IRE-ablation (electric field per distance, 1,500 V/cm; pulse length, 70 μs; number of pulses, 90) of 6 sciatic nerves was perf...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-012-2610-3
更新日期:2013-02-01 00:00:00
abstract:KEY POINTS:• Abbreviated MRI (AMRI) protocols consist of acquiring only a minimal number of MRI sequences for HCC surveillance with acceptable diagnostic performance compared to complete MRI.• AMRI protocol options include non-contrast AMRI, dynamic AMRI or hepatobiliary phase AMRI post gadoxetate injection.• The best ...
journal_title:European radiology
pub_type: 社论
doi:10.1007/s00330-020-06904-8
更新日期:2020-08-01 00:00:00
abstract:OBJECTIVES:We studied the usefulness of early dynamic (ED) and whole-body (WB) FDG-PET/CT for the evaluation of renal cell carcinoma (RCC). METHODS:One hundred patients with 107 tumours underwent kidney ED and WB FDG-PET/CT. We visually and semiquantitatively evaluated the FDG accumulation in RCCs in the ED and WB pha...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-4026-3
更新日期:2016-06-01 00:00:00
abstract::All currently available iodinated contrast media (CM) produce some form of haemodynamic or rheological change when injected. These effects are thought to be due primarily to the osmolality and viscosity of the CM. The new hexa-iodinated contrast agent Visipaque has the advantage of being iso-osmotic with blood at all ...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/BF02342566
更新日期:1996-01-01 00:00:00
abstract:OBJECTIVES:To evaluate the feasibility, image quality and radiation dose of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) with 30 mL contrast agent at 70 kVp. METHODS:Fifty-eight patients with suspected coronary artery disease, a body mass index (BMI) of less than 25 kg/m(2), sinus rhythm and a...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3157-2
更新日期:2014-07-01 00:00:00
abstract::The primitive hypoglossal artery (PHA) is a rare persistent carotid-basilar anastomosis. Usually it is found incidentally on angiography, but detection may be of importance for patient management. In the presented case MR- and CT angiography, which to our knowledge have not yet been reported in PHA, provided important...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050322
更新日期:1997-01-01 00:00:00
abstract::Several studies have shown that the thickness of tongue carcinoma is related to prognosis and to the likelihood of cervical node metastases. We investigated whether preoperative estimates of tumor thickness and volume, as determined from magnetic resonance imaging (MRI), correlated with histologic thickness and might ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-006-0263-9
更新日期:2006-10-01 00:00:00
abstract::The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, ple...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-006-0562-1
更新日期:2007-08-01 00:00:00
abstract::The aim of this study was to assess the upper airway status of sleep apnea syndrome (SAS) patients with low-field MR fluoroscopy. Twenty patients with clinically diagnosed SAS underwent upper airway monitoring using MR fluoroscopy for 5 min while awake and for 30 min while asleep. A 0.064-T permanent-magnet MR imaging...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050816
更新日期:1999-01-01 00:00:00
abstract::This report describes a malpractice case involving a delayed diagnosis of a malignant bone tumour in the proximal tibia in a 10-year-old child. This was caused by a combination of factors. The final report on the first examination failed to reach the patient files, and two subsequent X-ray exams failed to diagnose the...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300051021
更新日期:2000-01-01 00:00:00
abstract::Magnetization transfer (MT) provides post-gadolinium contrast improvement through decreasing the tissue signal. Our study had two aims: to analyse the effect of MT qualitatively and quantitatively in 13 patients, and to analyse in vitro the competition between two relaxation phenomena, dipole-dipole which is character...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/pl00006889
更新日期:1997-01-01 00:00:00
abstract::The original version of this article, published on 14 March 2019, unfortunately contained a mistake. ...
journal_title:European radiology
pub_type: 已发布勘误
doi:10.1007/s00330-019-06184-x
更新日期:2019-07-01 00:00:00