Congenital absence of the internal carotid artery and the basilar artery with persistent trigeminal artery associated with coarctation of the aorta.

Abstract:

:We report a case of congenital absence of the cervical and petrous part of the left internal carotid artery, the middle and proximal part of the basilar artery, and the V4 segment of the left vertebral artery associated with a left persistent trigeminal artery and a coarctation of the aorta. The left cerebral vessels are supplied via the anterior communicating artery and the left persistent trigeminal artery. The coexisting coarctation of the aorta led to a subclavian steal phenomenon. The alteration of the cerebral hemodynamics has to be taken in consideration when performing cerebral angiography and surgical correction in such a case.

journal_name

Eur Radiol

journal_title

European radiology

authors

Jaeger HJ,Mehring UM,Gissler HM,Mathias KD

doi

10.1007/s003300000500

subject

Has Abstract

pub_date

2000-01-01 00:00:00

pages

1805-9

issue

11

eissn

0938-7994

issn

1432-1084

journal_volume

10

pub_type

杂志文章
  • Functional MRI for immediate monitoring stereotactic thalamotomy in a patient with essential tremor.

    abstract::The effect of stereotactic thalamotomy was assessed with pre- and postoperative functional magnetic resonance imaging (fMRI) under motor stimulation. A patient with unilateral essential tremor (ET) of the left arm underwent stereotactically guided thalamotomy of the right ventral intermediate thalamic nucleus (VIM). F...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0211-8

    authors: Hesselmann V,Maarouf M,Hunsche S,Lasek K,Schaaf M,Krug B,Lackner K,Sturm V,Wedekind C

    更新日期:2006-10-01 00:00:00

  • Comparison of semi-automated and manual methods to measure the volume of liver tumours on MDCT images.

    abstract:OBJECTIVE:To retrospectively compare semi-automated and manual volume measurements of malignant liver tumours and inter- and intra-observer variability using commercially available software. METHODS:This study was performed on 60 consecutive patients with untreated liver metastases (30) and HCCs (30), i.e. 92 lesions ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-2013-2

    authors: Dubus L,Gayet M,Zappa M,Abaleo L,De Cooman A,Orieux G,Vilgrain V

    更新日期:2011-05-01 00:00:00

  • Direct magnetic resonance arthrography.

    abstract::Magnetic resonance (MR) arthrography has gained increasing popularity as a diagnostic tool in the assessment of intra-articular derangements. Its role has been studied extensively in the shoulder, but it also has been explored in the hip, elbow, knee, wrist and ankle. This article reviews the current role of direct MR...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2449-3

    authors: Elentuck D,Palmer WE

    更新日期:2004-11-01 00:00:00

  • Assessment of relevant hepatic steatosis in obese adolescents by rapid fat-selective GRE imaging with spatial-spectral excitation: a quantitative comparison with spectroscopic findings.

    abstract:OBJECTIVE:To test the feasibility of fat-selective GRE imaging using a spectral-spatial excitation technique for determination of intrahepatic lipid content (IHL) in obese adolescents. METHODS:Fat-selective MR imaging (1.5 T) was applied to record a single axial slice through a representative liver region within a sin...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1975-4

    authors: Springer F,Ehehalt S,Sommer J,Ballweg V,Machann J,Binder G,Claussen CD,Schick F,DISKUS-Study Group.

    更新日期:2011-04-01 00:00:00

  • Prostate cancer detection among readers with different degree of experience using ultra-high b-value diffusion-weighted Imaging: Is a non-contrast protocol sufficient to detect significant cancer?

    abstract:AIM:To evaluate the accuracy of a T2-weighted (T2w) - and a parallel transmit zoomed b = 2000 s/mm2 (b2000) - diffusion-weighted imaging sequence among three readers with different degrees of experience for prostate cancer (Pca) detection. METHODS:Ninety-three patients with suspected Pca were enrolled. For b2000 a two...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5004-8

    authors: Hausmann D,Aksöz N,von Hardenberg J,Martini T,Westhoff N,Buettner S,Schoenberg SO,Riffel P

    更新日期:2018-02-01 00:00:00

  • Large-volume multi-tined expandable RF ablation in pig livers: comparison of 2D and volumetric measurements of the ablation zone.

    abstract:OBJECTIVES:To compare two-dimensional (2D) and three-dimensional (3D) computed tomography (CT) measurements of ablation zones (AZs) related to the shaft of two different large-volume monopolar multi-tined expandable electrodes. METHODS:Percutaneous radiofrequency (RF) ablation was performed in 12 pigs (81.6 +/- 7.8 kg...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1639-4

    authors: Bangard C,Rösgen S,Wahba R,Wiemker R,Hellmich M,Reiter H,Fischer JH,Stippel DL,Lackner KJ

    更新日期:2010-05-01 00:00:00

  • MRI in patients with implanted active devices: how to combine safety and image quality using a limited transmission field?

    abstract:OBJECTIVES:Radio frequency (RF) pulses in magnetic resonance imaging (MRI) can interact with implanted devices and cause tissue damage. However, there are new devices that can safely perform measurements with liberal MRI conditions such as an RF transmission field B1+rms ≤ 2.0 μT. We investigated whether MRI in this ca...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06599-6

    authors: Lunden L,Wolff S,Peters S,Drews C,Gierloff C,Jensen-Kondering U,Langguth P,Madjidyar J,Piesch TC,Jansen O

    更新日期:2020-05-01 00:00:00

  • Everyman's prostate phantom: kiwi-fruit substitute for human prostates at magnetic resonance imaging, diffusion-weighted imaging and magnetic resonance spectroscopy.

    abstract:OBJECTIVES:To apply an easy-to-assemble phantom substitute for human prostates in T2-weighted magnetic resonance imaging (T2WI), diffusion-weighted imaging (DWI) and 3D magnetic resonance spectroscopy (MRS). METHODS:Kiwi fruit were fixed with gel hot and cold compress packs on two plastic nursery pots, separated by a ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4706-7

    authors: Mueller-Lisse UG,Murer S,Mueller-Lisse UL,Kuhn M,Scheidler J,Scherr M

    更新日期:2017-08-01 00:00:00

  • Toxic spongiform leucoencephalopathy after inhaling heroin vapour.

    abstract::This is a report of clinical, CT and MRI findings in a patient with toxic spongiform leucoencephalopathy after heroin ingestion. The disease is observed in drug addicts who inhale pre-heated heroin. The clinical onset, which usually occurs some days or even longer after the last heroin consumption, is characterized by...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050467

    authors: Weber W,Henkes H,Möller P,Bade K,Kühne D

    更新日期:1998-01-01 00:00:00

  • Transcatheter arterial chemoembolization in patients with hepatocellular carcinoma and coexisting hepatic cavernous hemangioma.

    abstract::We investigated the consequence of repeated transcatheter arterial chemoembolization (TACE) for coexisting small hepatic hemangioma in the treatment of patients with hepatocellular carcinomas and describe the imaging features of embolized hemangioma on the follow-up Lipiodol CT and MR. Six of 431 patients with biopsy-...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-0074-4

    authors: Chen RC,Lii JM,Chen WT,Tu HY,Chiang LC

    更新日期:2006-06-01 00:00:00

  • Dynamic MR imaging of osteoid osteomas: correlation of semiquantitative and quantitative perfusion parameters with patient symptoms and treatment outcome.

    abstract:OBJECTIVE:To evaluate the relationship between multiple MR perfusion parameters and symptoms of patients with osteoid osteomas after percutaneous laser therapy. METHODS:MR perfusion studies of 20 patients diagnosed with an osteoid osteoma, treated with CT-guided percutaneous laser therapy, were retrospectively evaluat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2867-1

    authors: Teixeira PA,Chanson A,Beaumont M,Lecocq S,Louis M,Marie B,Sirveaux F,Blum A

    更新日期:2013-09-01 00:00:00

  • Comparison of a new whole-body continuous-table-movement protocol versus a standard whole-body MR protocol for the assessment of multiple myeloma.

    abstract:OBJECTIVES:To evaluate a whole body (WB) continuous-table-movement (CTM) MR protocol for the assessment of multiple myeloma (MM) in comparison to a step-by-step WB protocol. METHODS:Eighteen patients with MM were examined at 1.5T using a WB CTM protocol (axial T2-w fs BLADE, T1-w GRE sequence) and a step-by-step WB pr...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1865-9

    authors: Weckbach S,Michaely HJ,Stemmer A,Schoenberg SO,Dinter DJ

    更新日期:2010-12-01 00:00:00

  • Correction to: Radiomics on multi-modalities MR sequences can subtype patients with non-metastatic nasopharyngeal carcinoma (NPC) into distinct survival subgroups.

    abstract::The original version of this article, published on 14 March 2019, unfortunately contained a mistake. ...

    journal_title:European radiology

    pub_type: 已发布勘误

    doi:10.1007/s00330-019-06184-x

    authors: Zhuo EH,Zhang WJ,Li HJ,Zhang GY,Jing BZ,Zhou J,Cui CY,Chen MY,Sun Y,Liu LZ,Cai HM

    更新日期:2019-07-01 00:00:00

  • Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique.

    abstract:OBJECTIVE:Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique. MATERIALS AND METHODS:One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, dist...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-014-3508-z

    authors: Anzidei M,Argirò R,Porfiri A,Boni F,Anile M,Zaccagna F,Vitolo D,Saba L,Napoli A,Leonardi A,Longo F,Venuta F,Bezzi M,Catalano C

    更新日期:2015-05-01 00:00:00

  • Upright, weight-bearing, dynamic-kinetic MRI of the spine: initial results.

    abstract::The potential relative beneficial aspects of upright, weight-bearing (pMRI), dynamic-kinetic (kMRI) spinal imaging over that of recumbent MRI (rMRI) include the revelation of occult spinal disease dependent on true axial loading, the unmasking of kinetic-dependent spinal disease and the ability to scan the patient in ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2666-4

    authors: Jinkins JR,Dworkin JS,Damadian RV

    更新日期:2005-09-01 00:00:00

  • MnDPDP-enhanced MRI vs dual-phase spiral CT in the detection of hepatocellular carcinoma in cirrhosis.

    abstract::The objectives of this study were twofold: (a) to assess safety and tolerability of the hepatobiliary MR contrast agent MnDPDP; and (b) to investigate the sensitivity of MnDPDP-enhanced MRI, in comparison with dual-phase spiral CT, in the detection of hepatocellular carcinoma (HCC) in cirrhosis. Fifty patients with li...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s003300000564

    authors: Bartolozzi C,Donati F,Cioni D,Crocetti L,Lencioni R

    更新日期:2000-01-01 00:00:00

  • Tracheal rupture caused by blunt chest trauma: radiological and clinical features.

    abstract::The aim of this study was to assess radiomorphologic and clinical features of tracheal rupture due to blunt chest trauma. From 1992 until 1998 the radiomorphologic and clinical key findings of all consecutive tracheal ruptures were retrospectively analyzed. The study included ten patients (7 men and 3 women; mean age ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050080

    authors: Kunisch-Hoppe M,Hoppe M,Rauber K,Popella C,Rau WS

    更新日期:2000-01-01 00:00:00

  • Aneurysmal bone cyst of the cervical spine (2008:7b).

    abstract::Aneurysmal bone cysts (ABC) are rare, benign, but locally destructive bone tumors. They occur in the spine in 14% of cases, but only 2% are found in the cervical spine. This case report presents a 16-year-old female with an expansive aneurysmatic bone cyst with extensive bone destruction and instability in the cervica...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0944-7

    authors: Pennekamp W,Peters S,Schinkel C,Kuhnen C,Nicolas V,Muhr G,Frangen TM

    更新日期:2008-10-01 00:00:00

  • Microwave ablation plus chemotherapy versus chemotherapy in advanced non-small cell lung cancer: a multicenter, randomized, controlled, phase III clinical trial.

    abstract:OBJECTIVES:This prospective trial was performed to verify whether microwave ablation (MWA) in combination with chemotherapy could provide superior survival benefit compared with chemotherapy alone. MATERIALS AND METHODS:From March 1, 2015, to June 20, 2017, treatment-naïve patients with pathologically verified advance...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1007/s00330-019-06613-x

    authors: Wei Z,Yang X,Ye X,Feng Q,Xu Y,Zhang L,Sun W,Dong Y,Meng Q,Li T,Wang C,Li G,Zhang K,Li P,Bi J,Xue G,Sun Y,Sheng L,Liu B,Yu G,Ren H,Wang J,Sun L,Chen S,Geng D,Zhang B,Xu X,Zhang L,Sun D,Xu X,Diao

    更新日期:2020-05-01 00:00:00

  • Impact of sublingual nitroglycerin dosage on FFRCT assessment and coronary luminal volume-to-myocardial mass ratio.

    abstract:OBJECTIVES:Fractional flow reserve computed tomography (FFRCT) depends upon nitroglycerin (NTG) inducing maximal hyperemia. However, the impact of NTG dosages on FFRCT analysis including coronary volume-to-mass ratio (V/M) is unknown. METHODS:Eighty patients with repeat coronary CT angiograms (CCTAs) with different su...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06293-7

    authors: Holmes KR,Fonte TA,Weir-McCall J,Anastasius M,Blanke P,Payne GW,Ellis J,Murphy DT,Taylor C,Leipsic JA,Sellers SL

    更新日期:2019-12-01 00:00:00

  • Ultrasound appearances of the testicular appendages: pictorial review.

    abstract::Five testicular appendages are formed during development of the male genito-urinary tract, which are the remnants of the degenerating mesonephric and paramesonephric ducts. The testicular and epididymal appendages, found at the upper pole of the testis and at the head of the epididymis respectively, are the most commo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1387-1

    authors: Sellars ME,Sidhu PS

    更新日期:2003-01-01 00:00:00

  • Acquisition time, radiation dose, subjective and objective image quality of dual-source CT scanners in acute pulmonary embolism: a comparative study.

    abstract:OBJECTIVES:To compare the scan acquisition time, radiation dose, subjective and objective image quality of two dual-source CT scanners (DSCT) for detection of acute pulmonary embolism. METHODS:Two hundred twenty-one scans performed on the 2nd-generation DSCT and 354 scans on the 3rd-generation DSCT were included in th...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06650-6

    authors: Abdellatif W,Esslinger E,Kobes K,Wong A,Powell J,Ali IT,Andrews G,Nicolaou S

    更新日期:2020-05-01 00:00:00

  • Pulmonary ventilation and perfusion imaging with dual-energy CT.

    abstract:OBJECTIVE:To evaluate the feasibility of dual-energy CT (DECT) ventilation imaging in combination with DE perfusion mapping for a comprehensive assessment of ventilation, perfusion, morphology and structure of the pulmonary parenchyma. METHODS:Two dual-energy CT acquisitions for xenon-enhanced ventilation and iodine-e...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1866-8

    authors: Thieme SF,Hoegl S,Nikolaou K,Fisahn J,Irlbeck M,Maxien D,Reiser MF,Becker CR,Johnson TR

    更新日期:2010-12-01 00:00:00

  • Subtraction CT angiography improves evaluation of significant coronary artery disease in patients with severe calcifications or stents-the C-Sub 320 multicenter trial.

    abstract:OBJECTIVES:Diagnostic accuracy of conventional coronary CT angiography (CCTAconv) may be compromised by blooming artifacts from calcifications or stents. Blooming artifacts may be reduced by subtraction coronary CT angiography (CCTAsub) in which non-contrast and contrast CT data sets are subtracted digitally. We tested...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-018-5418-y

    authors: Fuchs A,Kühl JT,Chen MY,Viladés Medel D,Alomar X,Shanbhag SM,Helqvist S,Kofoed KF

    更新日期:2018-10-01 00:00:00

  • Triple-TWIST MRA: high spatial and temporal resolution MR angiography of the entire peripheral vascular system using a time-resolved 4D MRA technique.

    abstract:OBJECTIVES:Multi-station contrast-enhanced magnetic resonance angiography (MRA) is considered as the imaging investigation of first choice in patients suffering from peripheral arterial occlusive disease. In order to overcome venous overlay and to gain dynamic flow information as provided by digital subtraction angiogr...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2574-3

    authors: Kinner S,Quick HH,Maderwald S,Hunold P,Barkhausen J,Vogt FM

    更新日期:2013-01-01 00:00:00

  • Pitfalls in sonography of the Gamekeeper's thumb.

    abstract::The gamekeeper's or skier's thumb is a very common injury. Nondisplaced tears of the ulnar collateral ligament of the thumb (UCL) may be treated conservatively. For that reason an accurate diagnosis is mandatory for choosing the correct therapy. Ultrasound is able to depict the position of the torn UCL correctly in ap...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050111

    authors: Hergan K,Mittler C,Oser W

    更新日期:1997-01-01 00:00:00

  • Advances in ultrasound.

    abstract::Significant advances have been recently introduced into various fields of technology, taking advantage of the use of new piezoelectric materials and the large diffusion of broadband transducers. Various types of modulation may be applied to the pulse characteristics, using single pulse, multipulse or multiline techniq...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-001-1185-1

    authors: Claudon M,Tranquart F,Evans DH,Lefèvre F,Correas M

    更新日期:2002-01-01 00:00:00

  • Dynamic contrast-enhanced MR imaging of endometrial cancer: optimizing the imaging delay for tumour-myometrium contrast.

    abstract:PURPOSE:To investigate the optimal imaging delay time of dynamic contrast-enhanced magnetic resonance (MR) imaging in women with endometrial cancer. MATERIALS AND METHODS:This prospective single-institution study was approved by the institutional review board, and informed consent was obtained from the participants. T...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3327-2

    authors: Park SB,Moon MH,Sung CK,Oh S,Lee YH

    更新日期:2014-11-01 00:00:00

  • Assessment of acute kidney injury with T1 mapping MRI following solid organ transplantation.

    abstract:OBJECTIVES:To evaluate T1 mapping as a non-invasive, functional MRI biomarker in patients shortly after solid organ transplantation to detect acute postsurgical kidney damage and to correlate T1 times with renal function. METHODS:101 patients within 2 weeks after solid organ transplantation (49 kidney transplantation,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4943-4

    authors: Peperhove M,Vo Chieu VD,Jang MS,Gutberlet M,Hartung D,Tewes S,Warnecke G,Fegbeutel C,Haverich A,Gwinner W,Lehner F,Bräsen JH,Haller H,Wacker F,Gueler F,Hueper K

    更新日期:2018-01-01 00:00:00

  • Repeatability of derived parameters from histograms following non-Gaussian diffusion modelling of diffusion-weighted imaging in a paediatric oncological cohort.

    abstract:OBJECTIVES:To examine repeatability of parameters derived from non-Gaussian diffusion models in data acquired in children with solid tumours. METHODS:Paediatric patients (<16 years, n = 17) were scanned twice, 24 h apart, using DWI (6 b-values, 0-1000 mm-2 s) at 1.5 T in a prospective study. Tumour ROIs were drawn (3 ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4318-2

    authors: Jerome NP,Miyazaki K,Collins DJ,Orton MR,d'Arcy JA,Wallace T,Moreno L,Pearson AD,Marshall LV,Carceller F,Leach MO,Zacharoulis S,Koh DM

    更新日期:2017-01-01 00:00:00